MEAN WELL BIC-2200 series: Bidirectional AC/DC Power Supply - BIC-2200-96

Description

MEAN WELL BIC-2200-96 is a bidirectional AC/DC power supply with a 96 V, 22.5 A, 2160 W AC-to-DC rating and grid-connected DC-to-AC energy recovery. Its digital 1U design combines automatic direction selection, fan cooling and active current sharing. This standard model has no communication protocol.

Product Datasheet

Download MEAN WELL BIC-2200 Datasheet (PDF)

The BIC-2200 section is on PDF pages 5, 6, 7, 8, 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation.

Model and Operating Modes

Series: BIC-2200; Complete ordering model: BIC-2200-96.

Communication: None; no communication suffix; Factory operating mode: Bidirectional automatic detection.

Typical direction-switching time: 1 ms.

AC-to-DC operation takes energy from the AC grid to supply a DC load or charge a battery. DC-to-AC operation returns energy from the DC side to the connected grid. Reverse operation synchronizes to the AC mains and is not a standalone AC source.

Automatic mode selects AC-to-DC when the set voltage exceeds the load voltage, and DC-to-AC when the set voltage is below the load voltage. The default target voltage is the model’s rated DC voltage. Use the operating characteristic and adjustment instructions for the actual load or battery.

This ordering code has no communication protocol and does not provide the CANBus-only battery mode or DIRECTION_CTRL commands.

Applications include battery formation and grading, V2G systems, electric-vehicle and scooter charging stations, marine charger modules, kinetic-energy recovery, battery testing, electrolysis and wastewater-treatment equipment. Match the complete system to its application and grid connection requirements.

AC-to-DC Output

DC output voltage 96 V
Rated output current 22.5 A
Rated output power 2160 W
Output current range 0–22.5 A
Full-power DC voltage range 96–112 V
DC voltage adjustment range 76–112 V
Ripple and noise, maximum 480 mVp-p
Voltage tolerance ±1.0%
Line / load regulation ±0.5% / ±0.5%
Setup / rise time 1800 ms / 60 ms at 230 VAC, full load

Observe voltage, current, rated power and derating limits together. Voltage and current maxima are not simultaneously available at every adjustment setting. Use SVR and the applicable operating instructions for voltage adjustment.

Voltage tolerance includes setup, line and load regulation. Ripple/noise is measured at 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

AC-to-DC Input

AC input range 180–264 VAC
Input frequency 47–63 Hz
Typical AC input current 11 A at 230 VAC
Typical power factor 0.98 at 230 VAC, full load
Typical conversion efficiency 93%
Efficiency test load 75%
Typical cold-start inrush 35 A at 230 VAC
Leakage current <2 mA at 230 VAC
Input current distortion THDi <3% at 230 VAC, 100% load

Unless separately stated, specification measurements use 230 VAC, rated load and 25°C ambient. The efficiency value uses 75% load. The digital power stage includes active inrush limiting; the block diagram identifies PFC switching at 70 kHz and PWM at 60 kHz.

DC-to-AC Energy Recovery

DC-to-AC rated input power 1800 W
Maximum DC input current 18.75 A
DC input voltage range 76–112 V
Full-power DC input range 96–112 V
Typical AC output power 1685 W
AC output power test voltage 240 V
Grid synchronization voltage 180–264 VAC
Grid synchronization frequency 47–63 Hz
Typical AC output current 7.5 A at 230 VAC
Typical reverse power factor 0.99 at 230 VAC, full load
Typical reverse efficiency 93%
Reverse efficiency test load 75%
Output current distortion THDi <3% at 230 VAC, 100% load

The 1800 W figure is the rated DC input power in energy-recovery operation; the AC output has its own typical rating and conversion losses. Above 96 V on the DC side, current is automatically reduced to respect the constant-power limit. Below 96 V, the maximum DC input current limits available power. Apply the input-voltage and temperature limits as well.

The AC output voltage and frequency are set by the connected mains. Anti-islanding protection shuts down the AC output when an islanding condition is detected; re-power to recover.

Protection and Recovery

Forward overload threshold 105–115% of rated output power
Overvoltage shutdown range 134–157 V
Short-circuit protection Output-current shutdown; re-power to recover
Overtemperature protection Output-voltage shutdown; automatic recovery after cooling
Anti-islanding protection AC-output shutdown; re-power to recover

In AC-to-DC overload, constant-current limiting is followed by output shutdown 5 seconds after the DC output voltage goes low; re-power to recover. DC-to-AC operation uses a constant-power design, so the forward overload sequence is not a reverse-mode operating allowance.

Overvoltage shuts down the output voltage and requires re-powering to recover. The Fault signal also reports the specified AC failure, overload, short-circuit, temperature, overvoltage, fan-lock and islanding conditions.

Cooling, Environment and Derating

Horizontal thermal curve: 100% load from −30 to +45°C, then declining to 50% at +70°C; AC-input load curve: 100% from 180 to 264 VAC, at 60 Hz.

Working temperature: −30 to +70°C, subject to derating; Working humidity: 20–90% RH, non-condensing.

Storage: −40 to +85°C; 10–95% RH, non-condensing; Temperature coefficient: ±0.03%/°C from 0 to 45°C.

Vibration: 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each on X, Y and Z.

Keep both built-in fans and the illustrated airflow path unobstructed. Apply thermal and input limits together. For fan-cooled operation above 2000 m, reduce permissible ambient temperature by 5°C per additional 1000 m; this note does not state a maximum operating altitude.

CN46 Remote Control and Alarm Signals

CN46 connector HRS DF11-10DP-2DS or equivalent
CN46 pin 1 +12V-AUX: 11.4–12.6 V, 0.5 A maximum
CN46 pins 2, 4 GND-AUX; isolated from main +V and −V
CN46 pin 3 +5V-AUX: 4.5–5.5 V, for remote ON-OFF use only
CN46 pin 5 Remote ON-OFF, connected relative to pin 3 (+5V-AUX)
CN46 pin 6 CANBus-model function; not available on this no-protocol model
CN46 pin 7 DC-OK output
CN46 pin 8 Fault output
CN46 pin 9 T-ALARM output
CN46 pin 10 NC
12 V auxiliary rating 12 V, 0.5 A; ±5% tolerance; 150 mVp-p ripple

Short the remote ON-OFF connection between pin 5 and pin 3 to turn the output ON; open it to turn the output OFF. The connection supports the specified electrical signal or dry contact. The auxiliary outputs are not switched by this remote control; use GND-AUX on pins 2 or 4 as their return.

DC-OK, Fault and T-ALARM are isolated, output-only TTL signals referenced to GND-AUX. High is 4.5–5.5 V, low is −0.5 to +0.5 V, and maximum sourcing current is 4 mA.

DC-OK is high when output voltage is at or below the catalogue 80% ±5% threshold and low when it is at or above that threshold. Fault is high at AC input ≤165 Vrms or for OLP, SCP, OTP, OVP, AC failure, fan lock or islanding protection; it is low at AC input ≥175 Vrms with normal operation.

T-ALARM is high when internal temperature exceeds the alarm limit or any fan fails; it is low when temperature and fans are normal. Alarm outputs must not be driven as control inputs.

CN47 Parallel and Communication Connections

CN47 connector HRS DF11-10DP-2DS or equivalent
CN47 pins 1, 2 DA differential parallel-control signal
CN47 pins 3, 4 DB differential parallel-control signal
CN47 pins 5, 6 GND: negative-output signal reference; not a load connection
CN47 pin 7 CANH is reserved for the CANBus model
CN47 pin 8 CANL is reserved for the CANBus model
CN47 pins 9, 10 GND-AUX; isolated from main output

DA and DB are non-isolated parallel-control signals referenced to CN47 GND. This negative-output signal return must not connect directly to the load. CANBus, where fitted, uses isolated GND-AUX instead; do not interchange the two reference grounds.

Follow the connector orientation shown in the mechanical drawing. Join DA to DA, DB to DB and the parallel GND references between units. Twist long CN47 signal lines in pairs to reduce noise.

Parallel Operation and Three-Phase Distribution

Maximum parallel units: 9; Maximum parallel output current: Rated current per unit × number of units × 0.95.

Single-unit SW50 setting: ON; CN47 parallel connection not fitted; Multi-unit SW50 settings: First and last units ON; all intermediate units OFF.

Use short, large-gauge output wiring. In a parallel system, the unit with the highest output-voltage setting is the master and determines the common DC-bus voltage. Observe each unit’s voltage, current and power limits as well as the 0.95 total-current factor. Below 5% of the total rated current, current sharing may be unbalanced.

In a three-phase, four-wire system, distribute the individual BIC units evenly across the phases and neutral; the nine-unit example uses three units per phase. Each unit still receives single-phase L-to-N voltage within 180–264 VAC, with FG correctly connected. The drawing shows 220 VAC phase-to-neutral and 380 VAC phase-to-phase; it does not permit 380 VAC across one unit’s AC terminals.

Mechanical Installation and Mating Parts

Dimensions 330 × 140 × 41 mm
Profile / case drawing 1U; case 277C; general dimensional tolerance ±0.5 mm
Catalogue unit weight 2900 g
Weight basis Catalogue packing reference per unit; not a measured net or shipping weight
AC terminal TB1 1 = AC/L; 2 = AC/N; 3 = FG
Installed AC terminal marking DECA T35-EO32-03
AC-terminal maximum torque 18 kgf·cm
DC terminals +V and −V; drawing marks two M5 positions
DC-terminal maximum torque 10 kgf·cm
Mounting screws M4; maximum penetration 4.5 mm; recommended torque 7–10 kgf·cm
CN46 / CN47 mating housing HRS DF11-10DS or equivalent
CN46 / CN47 contact family HRS DF11-**SC or equivalent

The side drawings show two M4 mounting positions on each side, 289 mm apart. The bottom drawing shows four M4 positions on a 225 × 78 mm pattern with the depicted 71.55 mm and 33.5 mm edge references. Allow for the input-terminal projection marked 13 mm maximum, terminal wiring and unobstructed fan airflow.

DF11-10DS is the listed mating housing. DF11-**SC is a contact-family designation with an incomplete suffix; choose the complete contact reference for the wire and housing. The catalogue does not specify a separately numbered MEAN WELL cable kit or promise these mating parts are included.

The LED is steady green in AC-to-DC supply operation, flashing green in DC-to-AC grid-inverter operation, and red for an abnormal condition such as overtemperature, overload or fan failure. SVR is the marked voltage adjustment.

For the specified dielectric-withstand and insulation-resistance tests, temporarily remove the marked screw A, then restore it after testing. Follow the manufacturer’s test and installation procedure.

Safety, EMC and Reliability

Dielectric withstand: Input/output: 3 kVAC; input/FG: 2 kVAC; output/FG: 500 VAC; Insulation resistance: 100 MΩ at 500 VDC, 25°C, 70% RH; input/output, input/FG and output/FG.

Conducted / radiated emissions: BS EN/EN 55032 (CISPR32), Class A / Class A; Harmonics / flicker: BS EN/EN 61000-3-2, Class A / BS EN/EN 61000-3-3.

Minimum calculated MTBF: 462.9 thousand hours, Telcordia SR-332; 46 thousand hours, MIL-HDBK-217F at 25°C; Manufacturer warranty: 5 years.

The catalogue lists UL 62368-1, IEC 62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN 62368-1, EAC TP TC 004, IEC 62477-1 and TUV BS EN/EN 62477-1 approvals. These product qualifications do not certify the completed installation.

Immunity references BS EN/EN 55035 and BS EN/EN 61000-6-2. The listed tests include ESD 8 kV air (Level 3) and 4 kV contact (Level 2); radiated RF, EFT/burst and conducted RF Level 3; surge 2 kV line-to-line and 4 kV line-to-earth; and magnetic field Level 4. Voltage dips are >95% for 0.5 period and 30% for 25 periods; interruptions are >95% for 250 periods.

MEAN WELL BIC-2200 series: Bidirectional AC/DC Power Supply - BIC-2200-96

Product form

MEAN WELL BIC-2200-96 is a bidirectional AC/DC power supply with a 96 V, 22.5 A, 2160 W AC-to-DC rating and... Read more

$1,867.93 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL BIC-2200-96 is a bidirectional AC/DC power supply with a 96 V, 22.5 A, 2160 W AC-to-DC rating and grid-connected DC-to-AC energy recovery. Its digital 1U design combines automatic direction selection, fan cooling and active current sharing. This standard model has no communication protocol.

    Product Datasheet

    Download MEAN WELL BIC-2200 Datasheet (PDF)

    The BIC-2200 section is on PDF pages 5, 6, 7, 8, 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation.

    Model and Operating Modes

    Series: BIC-2200; Complete ordering model: BIC-2200-96.

    Communication: None; no communication suffix; Factory operating mode: Bidirectional automatic detection.

    Typical direction-switching time: 1 ms.

    AC-to-DC operation takes energy from the AC grid to supply a DC load or charge a battery. DC-to-AC operation returns energy from the DC side to the connected grid. Reverse operation synchronizes to the AC mains and is not a standalone AC source.

    Automatic mode selects AC-to-DC when the set voltage exceeds the load voltage, and DC-to-AC when the set voltage is below the load voltage. The default target voltage is the model’s rated DC voltage. Use the operating characteristic and adjustment instructions for the actual load or battery.

    This ordering code has no communication protocol and does not provide the CANBus-only battery mode or DIRECTION_CTRL commands.

    Applications include battery formation and grading, V2G systems, electric-vehicle and scooter charging stations, marine charger modules, kinetic-energy recovery, battery testing, electrolysis and wastewater-treatment equipment. Match the complete system to its application and grid connection requirements.

    AC-to-DC Output

    DC output voltage 96 V
    Rated output current 22.5 A
    Rated output power 2160 W
    Output current range 0–22.5 A
    Full-power DC voltage range 96–112 V
    DC voltage adjustment range 76–112 V
    Ripple and noise, maximum 480 mVp-p
    Voltage tolerance ±1.0%
    Line / load regulation ±0.5% / ±0.5%
    Setup / rise time 1800 ms / 60 ms at 230 VAC, full load

    Observe voltage, current, rated power and derating limits together. Voltage and current maxima are not simultaneously available at every adjustment setting. Use SVR and the applicable operating instructions for voltage adjustment.

    Voltage tolerance includes setup, line and load regulation. Ripple/noise is measured at 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    AC-to-DC Input

    AC input range 180–264 VAC
    Input frequency 47–63 Hz
    Typical AC input current 11 A at 230 VAC
    Typical power factor 0.98 at 230 VAC, full load
    Typical conversion efficiency 93%
    Efficiency test load 75%
    Typical cold-start inrush 35 A at 230 VAC
    Leakage current <2 mA at 230 VAC
    Input current distortion THDi <3% at 230 VAC, 100% load

    Unless separately stated, specification measurements use 230 VAC, rated load and 25°C ambient. The efficiency value uses 75% load. The digital power stage includes active inrush limiting; the block diagram identifies PFC switching at 70 kHz and PWM at 60 kHz.

    DC-to-AC Energy Recovery

    DC-to-AC rated input power 1800 W
    Maximum DC input current 18.75 A
    DC input voltage range 76–112 V
    Full-power DC input range 96–112 V
    Typical AC output power 1685 W
    AC output power test voltage 240 V
    Grid synchronization voltage 180–264 VAC
    Grid synchronization frequency 47–63 Hz
    Typical AC output current 7.5 A at 230 VAC
    Typical reverse power factor 0.99 at 230 VAC, full load
    Typical reverse efficiency 93%
    Reverse efficiency test load 75%
    Output current distortion THDi <3% at 230 VAC, 100% load

    The 1800 W figure is the rated DC input power in energy-recovery operation; the AC output has its own typical rating and conversion losses. Above 96 V on the DC side, current is automatically reduced to respect the constant-power limit. Below 96 V, the maximum DC input current limits available power. Apply the input-voltage and temperature limits as well.

    The AC output voltage and frequency are set by the connected mains. Anti-islanding protection shuts down the AC output when an islanding condition is detected; re-power to recover.

    Protection and Recovery

    Forward overload threshold 105–115% of rated output power
    Overvoltage shutdown range 134–157 V
    Short-circuit protection Output-current shutdown; re-power to recover
    Overtemperature protection Output-voltage shutdown; automatic recovery after cooling
    Anti-islanding protection AC-output shutdown; re-power to recover

    In AC-to-DC overload, constant-current limiting is followed by output shutdown 5 seconds after the DC output voltage goes low; re-power to recover. DC-to-AC operation uses a constant-power design, so the forward overload sequence is not a reverse-mode operating allowance.

    Overvoltage shuts down the output voltage and requires re-powering to recover. The Fault signal also reports the specified AC failure, overload, short-circuit, temperature, overvoltage, fan-lock and islanding conditions.

    Cooling, Environment and Derating

    Horizontal thermal curve: 100% load from −30 to +45°C, then declining to 50% at +70°C; AC-input load curve: 100% from 180 to 264 VAC, at 60 Hz.

    Working temperature: −30 to +70°C, subject to derating; Working humidity: 20–90% RH, non-condensing.

    Storage: −40 to +85°C; 10–95% RH, non-condensing; Temperature coefficient: ±0.03%/°C from 0 to 45°C.

    Vibration: 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each on X, Y and Z.

    Keep both built-in fans and the illustrated airflow path unobstructed. Apply thermal and input limits together. For fan-cooled operation above 2000 m, reduce permissible ambient temperature by 5°C per additional 1000 m; this note does not state a maximum operating altitude.

    CN46 Remote Control and Alarm Signals

    CN46 connector HRS DF11-10DP-2DS or equivalent
    CN46 pin 1 +12V-AUX: 11.4–12.6 V, 0.5 A maximum
    CN46 pins 2, 4 GND-AUX; isolated from main +V and −V
    CN46 pin 3 +5V-AUX: 4.5–5.5 V, for remote ON-OFF use only
    CN46 pin 5 Remote ON-OFF, connected relative to pin 3 (+5V-AUX)
    CN46 pin 6 CANBus-model function; not available on this no-protocol model
    CN46 pin 7 DC-OK output
    CN46 pin 8 Fault output
    CN46 pin 9 T-ALARM output
    CN46 pin 10 NC
    12 V auxiliary rating 12 V, 0.5 A; ±5% tolerance; 150 mVp-p ripple

    Short the remote ON-OFF connection between pin 5 and pin 3 to turn the output ON; open it to turn the output OFF. The connection supports the specified electrical signal or dry contact. The auxiliary outputs are not switched by this remote control; use GND-AUX on pins 2 or 4 as their return.

    DC-OK, Fault and T-ALARM are isolated, output-only TTL signals referenced to GND-AUX. High is 4.5–5.5 V, low is −0.5 to +0.5 V, and maximum sourcing current is 4 mA.

    DC-OK is high when output voltage is at or below the catalogue 80% ±5% threshold and low when it is at or above that threshold. Fault is high at AC input ≤165 Vrms or for OLP, SCP, OTP, OVP, AC failure, fan lock or islanding protection; it is low at AC input ≥175 Vrms with normal operation.

    T-ALARM is high when internal temperature exceeds the alarm limit or any fan fails; it is low when temperature and fans are normal. Alarm outputs must not be driven as control inputs.

    CN47 Parallel and Communication Connections

    CN47 connector HRS DF11-10DP-2DS or equivalent
    CN47 pins 1, 2 DA differential parallel-control signal
    CN47 pins 3, 4 DB differential parallel-control signal
    CN47 pins 5, 6 GND: negative-output signal reference; not a load connection
    CN47 pin 7 CANH is reserved for the CANBus model
    CN47 pin 8 CANL is reserved for the CANBus model
    CN47 pins 9, 10 GND-AUX; isolated from main output

    DA and DB are non-isolated parallel-control signals referenced to CN47 GND. This negative-output signal return must not connect directly to the load. CANBus, where fitted, uses isolated GND-AUX instead; do not interchange the two reference grounds.

    Follow the connector orientation shown in the mechanical drawing. Join DA to DA, DB to DB and the parallel GND references between units. Twist long CN47 signal lines in pairs to reduce noise.

    Parallel Operation and Three-Phase Distribution

    Maximum parallel units: 9; Maximum parallel output current: Rated current per unit × number of units × 0.95.

    Single-unit SW50 setting: ON; CN47 parallel connection not fitted; Multi-unit SW50 settings: First and last units ON; all intermediate units OFF.

    Use short, large-gauge output wiring. In a parallel system, the unit with the highest output-voltage setting is the master and determines the common DC-bus voltage. Observe each unit’s voltage, current and power limits as well as the 0.95 total-current factor. Below 5% of the total rated current, current sharing may be unbalanced.

    In a three-phase, four-wire system, distribute the individual BIC units evenly across the phases and neutral; the nine-unit example uses three units per phase. Each unit still receives single-phase L-to-N voltage within 180–264 VAC, with FG correctly connected. The drawing shows 220 VAC phase-to-neutral and 380 VAC phase-to-phase; it does not permit 380 VAC across one unit’s AC terminals.

    Mechanical Installation and Mating Parts

    Dimensions 330 × 140 × 41 mm
    Profile / case drawing 1U; case 277C; general dimensional tolerance ±0.5 mm
    Catalogue unit weight 2900 g
    Weight basis Catalogue packing reference per unit; not a measured net or shipping weight
    AC terminal TB1 1 = AC/L; 2 = AC/N; 3 = FG
    Installed AC terminal marking DECA T35-EO32-03
    AC-terminal maximum torque 18 kgf·cm
    DC terminals +V and −V; drawing marks two M5 positions
    DC-terminal maximum torque 10 kgf·cm
    Mounting screws M4; maximum penetration 4.5 mm; recommended torque 7–10 kgf·cm
    CN46 / CN47 mating housing HRS DF11-10DS or equivalent
    CN46 / CN47 contact family HRS DF11-**SC or equivalent

    The side drawings show two M4 mounting positions on each side, 289 mm apart. The bottom drawing shows four M4 positions on a 225 × 78 mm pattern with the depicted 71.55 mm and 33.5 mm edge references. Allow for the input-terminal projection marked 13 mm maximum, terminal wiring and unobstructed fan airflow.

    DF11-10DS is the listed mating housing. DF11-**SC is a contact-family designation with an incomplete suffix; choose the complete contact reference for the wire and housing. The catalogue does not specify a separately numbered MEAN WELL cable kit or promise these mating parts are included.

    The LED is steady green in AC-to-DC supply operation, flashing green in DC-to-AC grid-inverter operation, and red for an abnormal condition such as overtemperature, overload or fan failure. SVR is the marked voltage adjustment.

    For the specified dielectric-withstand and insulation-resistance tests, temporarily remove the marked screw A, then restore it after testing. Follow the manufacturer’s test and installation procedure.

    Safety, EMC and Reliability

    Dielectric withstand: Input/output: 3 kVAC; input/FG: 2 kVAC; output/FG: 500 VAC; Insulation resistance: 100 MΩ at 500 VDC, 25°C, 70% RH; input/output, input/FG and output/FG.

    Conducted / radiated emissions: BS EN/EN 55032 (CISPR32), Class A / Class A; Harmonics / flicker: BS EN/EN 61000-3-2, Class A / BS EN/EN 61000-3-3.

    Minimum calculated MTBF: 462.9 thousand hours, Telcordia SR-332; 46 thousand hours, MIL-HDBK-217F at 25°C; Manufacturer warranty: 5 years.

    The catalogue lists UL 62368-1, IEC 62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN 62368-1, EAC TP TC 004, IEC 62477-1 and TUV BS EN/EN 62477-1 approvals. These product qualifications do not certify the completed installation.

    Immunity references BS EN/EN 55035 and BS EN/EN 61000-6-2. The listed tests include ESD 8 kV air (Level 3) and 4 kV contact (Level 2); radiated RF, EFT/burst and conducted RF Level 3; surge 2 kV line-to-line and 4 kV line-to-earth; and magnetic field Level 4. Voltage dips are >95% for 0.5 period and 30% for 25 periods; interruptions are >95% for 250 periods.

    Recently viewed products

      Footer image

      © 2026 MEAN WELL, ,

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • AliPay
      • Amazon
      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • USDC
      • Visa