MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000

Description

DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 10 ~ 60VDC AC output power rating (Typ.):2600 ~ 4320VA (for input 10 ~ 12VDC),4320 ~ 4400VA (for input 12 ~ 60VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):504X211X83.5 DC Input Connector: NEWSOK

Product Features

1. DC/AC AC grid-connected energy recovery inverter.

2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model).

3. Modular design, flexible configuration of aging test can be grouped or partitioned.

4. CC/CV operation mode can be flexibly selected.

5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management.

6. Up to 64 ERG-5000 communications can be connected.

7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure.

8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.

MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000

Product form

DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 10 ~... Read more

$13,524.43 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 10 ~ 60VDC AC output power rating (Typ.):2600 ~ 4320VA (for input 10 ~ 12VDC),4320 ~ 4400VA (for input 12 ~ 60VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):504X211X83.5 DC Input Connector: NEWSOK

    Product Features

    1. DC/AC AC grid-connected energy recovery inverter.

    2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model).

    3. Modular design, flexible configuration of aging test can be grouped or partitioned.

    4. CC/CV operation mode can be flexibly selected.

    5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management.

    6. Up to 64 ERG-5000 communications can be connected.

    7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure.

    8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.

    Recently viewed products