MEAN WELL ERP-200 series: enclosed constant-voltage power supply - ERP-200-24

Description

ERP-200-24 enclosed power supply

MEAN WELL ERP-200-24 is a single-output enclosed AC/DC constant-voltage switching power supply for LED signage, channel letters and commercial displays. It provides 24 V DC with a catalog current range of 0–8.33 A and rated output power of 199.92 W. Use the specified 180–264 VAC input range and the model-specific temperature and input derating curves.

Download MEAN WELL ERP-200 Datasheet (PDF)

Catalog pages 1–5; series revision 2025-12-12.

Download MEAN WELL Enclosed-Type Installation Manual

Output and model selection

Parameter Model-specific information
Model and output type ERP-200-24; ERP-200 series; single-output constant-voltage AC/DC power supply. The final 24 code identifies the nominal output voltage.
Nominal DC output 24 V
Rated output current 8.33 A; operating current range 0–8.33 A.
Rated output power 199.92 W; voltage, current, power and derating limits must all be observed.
Output-voltage adjustment 21.6–26.4 V DC, via the +V ADJ control; keep output current and power within the model limits.
Ripple and noise 150 mVp-p maximum. Measured at 20 MHz bandwidth with a 12-inch twisted pair terminated in parallel 0.1 µF and 47 µF capacitors.
Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation.
Line / load regulation Line: ±0.5%; load: ±0.5%.
Setup / rise time 1500 ms / 200 ms at 230 VAC.
Hold-up time 20 ms typical at 230 VAC.

Input and loading

Parameter Model-specific information
Input voltage 180–264 VAC; 254–370 VDC.
AC frequency 47–63 Hz.
Short-duration input withstand 300 VAC for 5 seconds, as stated in the catalog; this does not extend the continuous input-voltage range.
Typical efficiency 89% under the catalog measurement conditions.
Typical AC current 4 A at 230 VAC.
Typical inrush current 90 A at 230 VAC.
Leakage current Less than 1 mA at 240 VAC.
Input/load derating At 60 Hz: 80% load at 180 VAC, rising along the plotted line to 100% at 200 VAC; 100% through 264 VAC. Also apply temperature derating.

Protection behavior

Parameter Model-specific information
Short circuit Hiccup mode; recovers automatically after the fault is removed.
Overload 110–140% of rated output power. Constant-current limiting; recovers automatically after the fault is removed.
Overvoltage 27.6–32.4 V. Hiccup mode; recovers automatically after the fault is removed.
Overtemperature Shuts down the output; recovers automatically after the temperature falls.

Operating environment

Parameter Model-specific information
Cooling and ambient temperature Free-air convection; operating ambient −30 to +60°C, subject to derating.
Temperature/load derating For the catalog VERTICAL installation: 100% load from −30 to +40°C, then follow the declining curve to 50% at +60°C. Do not treat the +60°C operating limit as a full-load rating.
Working humidity 20–90% RH, non-condensing.
Storage −30 to +85°C; 10–95% RH.
Temperature coefficient ±0.05%/°C over 0–50°C.
Vibration 10–500 Hz, 3G; 10 minutes per cycle, 60 minutes each along X, Y and Z axes.

Dimensions, wiring and installation

Parameter Model-specific information
Enclosure Aluminum case with a semi-potted interior designed to protect internal components against rain splash and dust. The catalog does not assign a numeric IP rating.
Outdoor location For outdoor applications, install in a place with shelter as required by the model-specific installation page.
Dimensions 200 × 120 × 40 mm (L × W × H); mechanical drawing tolerance ±1 mm.
Mounting drawing Case No. 273. The main case body length is 179.6 mm; the complete length above includes the mounting extension. The end mounting slot has a Ø8 mm circular entry and a 20.4 mm extension. Use the actual model drawing to lay out mounting points.
Terminal assignment 1 = AC/L; 2 = AC/N; 3 = FG (earth); 4–5 = DC output −V; 6–7 = DC output +V.
Controls and indicator +V ADJ output-voltage adjustment and a power-on LED indicator are located beside the terminal block; terminal pitch is 9.5 mm.
Installation orientation Install upright in the catalog vertical position. Do not lean the unit forward or backward, and do not lay it flat.
Ventilation clearance Keep at least 10 cm above, below, to the left and to the right, and retain the illustrated 5 cm clearance at the ventilation-hole side. Keep the ventilation openings unobstructed.
Unit mass 860 g: catalog PACKING reference per unit (0.86 kg × 1000). This is not a measured shipment weight.

Installation manual requirements

Parameter Model-specific information
Installation isolation Disconnect the utility supply and prevent inadvertent reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself.
Mounting screws Maintain adequate insulation between mounting screws and internal components. Confirm the permitted screw length and supplied mounting hardware with MEAN WELL before installation.
Ventilation and nearby heat sources Keep ventilation openings unobstructed. Maintain 10–15 cm clearance when the adjacent device is a heat source, in addition to this model’s specified installation clearances.
Conductor and terminal installation Select conductors for the actual current and temperature conditions. The installation manual requires each wire to carry no more than 80% of its suggested wire-table current when five or more wires are connected to the unit. Keep every strand inside its terminal and secure all terminal connections.
Protective earth and system verification Connect AC/L to live, AC/N to neutral and FG to protective earth according to the model’s terminal diagram. Verify EMC again in the completed equipment.
Environment and load limits Do not install the unit in high-moisture locations or near water, fire, or temperatures above its specified ambient limit. Keep output current and power within this model’s rated and derated limits.
Specified installation position Install upright; forward tilt, backward tilt and flat mounting are not permitted. Keep at least 10 cm clearance above, below, left and right, and 5 cm at the ventilation-hole side. Outdoor installation requires a sheltered location.

Standards and catalog conditions

Parameter Model-specific information
Safety standards IEC/BS EN/EN 62368-1, GB 4943.1, EAC TP TC 004 and IS 13252 (Part 1) approved, as listed in the catalog.
Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC.
Isolation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG.
EMC emission Catalog reference basis: BS EN/EN 55022 (CISPR 22), Class A; EAC TP TC 020.
EMC immunity Catalog reference basis: BS EN/EN 55035 and BS EN/EN 61000-4-5, light-industry level; EAC TP TC 020.
MTBF 2233.7 thousand hours minimum, Telcordia SR-332 (Bellcore); 262.9 thousand hours minimum, MIL-HDBK-217F at 25°C.
Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Typical figures describe the stated conditions, not every operating point.
Factory and warranty statement The manufacturer catalog states 100% full-load burn-in testing and a 3-year warranty. Warranty coverage is subject to the manufacturer’s applicable terms.

MEAN WELL ERP-200 series: enclosed constant-voltage power supply - ERP-200-24

Product form

ERP-200-24 enclosed power supply MEAN WELL ERP-200-24 is a single-output enclosed AC/DC constant-voltage switching power supply for LED signage, channel... Read more

$64.56 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    ERP-200-24 enclosed power supply

    MEAN WELL ERP-200-24 is a single-output enclosed AC/DC constant-voltage switching power supply for LED signage, channel letters and commercial displays. It provides 24 V DC with a catalog current range of 0–8.33 A and rated output power of 199.92 W. Use the specified 180–264 VAC input range and the model-specific temperature and input derating curves.

    Download MEAN WELL ERP-200 Datasheet (PDF)

    Catalog pages 1–5; series revision 2025-12-12.

    Download MEAN WELL Enclosed-Type Installation Manual

    Output and model selection

    Parameter Model-specific information
    Model and output type ERP-200-24; ERP-200 series; single-output constant-voltage AC/DC power supply. The final 24 code identifies the nominal output voltage.
    Nominal DC output 24 V
    Rated output current 8.33 A; operating current range 0–8.33 A.
    Rated output power 199.92 W; voltage, current, power and derating limits must all be observed.
    Output-voltage adjustment 21.6–26.4 V DC, via the +V ADJ control; keep output current and power within the model limits.
    Ripple and noise 150 mVp-p maximum. Measured at 20 MHz bandwidth with a 12-inch twisted pair terminated in parallel 0.1 µF and 47 µF capacitors.
    Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation.
    Line / load regulation Line: ±0.5%; load: ±0.5%.
    Setup / rise time 1500 ms / 200 ms at 230 VAC.
    Hold-up time 20 ms typical at 230 VAC.

    Input and loading

    Parameter Model-specific information
    Input voltage 180–264 VAC; 254–370 VDC.
    AC frequency 47–63 Hz.
    Short-duration input withstand 300 VAC for 5 seconds, as stated in the catalog; this does not extend the continuous input-voltage range.
    Typical efficiency 89% under the catalog measurement conditions.
    Typical AC current 4 A at 230 VAC.
    Typical inrush current 90 A at 230 VAC.
    Leakage current Less than 1 mA at 240 VAC.
    Input/load derating At 60 Hz: 80% load at 180 VAC, rising along the plotted line to 100% at 200 VAC; 100% through 264 VAC. Also apply temperature derating.

    Protection behavior

    Parameter Model-specific information
    Short circuit Hiccup mode; recovers automatically after the fault is removed.
    Overload 110–140% of rated output power. Constant-current limiting; recovers automatically after the fault is removed.
    Overvoltage 27.6–32.4 V. Hiccup mode; recovers automatically after the fault is removed.
    Overtemperature Shuts down the output; recovers automatically after the temperature falls.

    Operating environment

    Parameter Model-specific information
    Cooling and ambient temperature Free-air convection; operating ambient −30 to +60°C, subject to derating.
    Temperature/load derating For the catalog VERTICAL installation: 100% load from −30 to +40°C, then follow the declining curve to 50% at +60°C. Do not treat the +60°C operating limit as a full-load rating.
    Working humidity 20–90% RH, non-condensing.
    Storage −30 to +85°C; 10–95% RH.
    Temperature coefficient ±0.05%/°C over 0–50°C.
    Vibration 10–500 Hz, 3G; 10 minutes per cycle, 60 minutes each along X, Y and Z axes.

    Dimensions, wiring and installation

    Parameter Model-specific information
    Enclosure Aluminum case with a semi-potted interior designed to protect internal components against rain splash and dust. The catalog does not assign a numeric IP rating.
    Outdoor location For outdoor applications, install in a place with shelter as required by the model-specific installation page.
    Dimensions 200 × 120 × 40 mm (L × W × H); mechanical drawing tolerance ±1 mm.
    Mounting drawing Case No. 273. The main case body length is 179.6 mm; the complete length above includes the mounting extension. The end mounting slot has a Ø8 mm circular entry and a 20.4 mm extension. Use the actual model drawing to lay out mounting points.
    Terminal assignment 1 = AC/L; 2 = AC/N; 3 = FG (earth); 4–5 = DC output −V; 6–7 = DC output +V.
    Controls and indicator +V ADJ output-voltage adjustment and a power-on LED indicator are located beside the terminal block; terminal pitch is 9.5 mm.
    Installation orientation Install upright in the catalog vertical position. Do not lean the unit forward or backward, and do not lay it flat.
    Ventilation clearance Keep at least 10 cm above, below, to the left and to the right, and retain the illustrated 5 cm clearance at the ventilation-hole side. Keep the ventilation openings unobstructed.
    Unit mass 860 g: catalog PACKING reference per unit (0.86 kg × 1000). This is not a measured shipment weight.

    Installation manual requirements

    Parameter Model-specific information
    Installation isolation Disconnect the utility supply and prevent inadvertent reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself.
    Mounting screws Maintain adequate insulation between mounting screws and internal components. Confirm the permitted screw length and supplied mounting hardware with MEAN WELL before installation.
    Ventilation and nearby heat sources Keep ventilation openings unobstructed. Maintain 10–15 cm clearance when the adjacent device is a heat source, in addition to this model’s specified installation clearances.
    Conductor and terminal installation Select conductors for the actual current and temperature conditions. The installation manual requires each wire to carry no more than 80% of its suggested wire-table current when five or more wires are connected to the unit. Keep every strand inside its terminal and secure all terminal connections.
    Protective earth and system verification Connect AC/L to live, AC/N to neutral and FG to protective earth according to the model’s terminal diagram. Verify EMC again in the completed equipment.
    Environment and load limits Do not install the unit in high-moisture locations or near water, fire, or temperatures above its specified ambient limit. Keep output current and power within this model’s rated and derated limits.
    Specified installation position Install upright; forward tilt, backward tilt and flat mounting are not permitted. Keep at least 10 cm clearance above, below, left and right, and 5 cm at the ventilation-hole side. Outdoor installation requires a sheltered location.

    Standards and catalog conditions

    Parameter Model-specific information
    Safety standards IEC/BS EN/EN 62368-1, GB 4943.1, EAC TP TC 004 and IS 13252 (Part 1) approved, as listed in the catalog.
    Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC.
    Isolation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG.
    EMC emission Catalog reference basis: BS EN/EN 55022 (CISPR 22), Class A; EAC TP TC 020.
    EMC immunity Catalog reference basis: BS EN/EN 55035 and BS EN/EN 61000-4-5, light-industry level; EAC TP TC 020.
    MTBF 2233.7 thousand hours minimum, Telcordia SR-332 (Bellcore); 262.9 thousand hours minimum, MIL-HDBK-217F at 25°C.
    Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Typical figures describe the stated conditions, not every operating point.
    Factory and warranty statement The manufacturer catalog states 100% full-load burn-in testing and a 3-year warranty. Warranty coverage is subject to the manufacturer’s applicable terms.