MEAN WELL GE40I05-P1J is a Class II AC/DC power adapter providing 5 VDC at 4 A, with a 20 W maximum rated output and a center-positive P1J DC plug. Its interchangeable AC plug is ordered separately. Apply the input-voltage and ambient-temperature derating for the installation.
Product Datasheet
Download MEAN WELL GE40 Datasheet (PDF)
The GE40 section is on PDF pages 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation.
Model and Configuration
| Complete order model |
GE40I05-P1J. |
| Output-voltage code |
05 identifies 5 VDC. Select this exact voltage/current model. |
| Construction |
Interchangeable-plug AC/DC adapter; Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. |
| Standard DC plug |
P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. |
| Mains plug |
The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. |
Output Ratings
| DC output voltage |
5 VDC. |
| Rated current / load range |
4 A rated; 0–4 A operating range. |
| Rated power, maximum |
20 W; observe both the current limit and the rated power, together with applicable derating. |
| Ripple and noise, maximum |
100 mVp-p under the measurement conditions below. |
| Voltage tolerance |
±3%. |
| Line regulation |
±1%. |
| Load regulation |
±3%. |
| Efficiency, typical |
81% under the general test conditions below. |
Input and Timing
| Input range |
90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. |
| AC input current |
1 A at 100 VAC; 0.5 A at 230 VAC. |
| Cold-start inrush, maximum |
35 A at 100 VAC; 70 A at 230 VAC. |
| Leakage current, maximum |
0.25 mA at 240 VAC. |
| Set-up / rise / hold-up time |
3000 ms / 40 ms / 12 ms at 115 VAC and 230 VAC, full load. |
| No-load power |
Less than 0.075 W. |
| Energy efficiency |
Level VI; EISA 2007 / US DoE, EU ErP and CoC Version 5 compliance. |
Protection and Indication
| Short circuit / overload |
Overload protection at 110–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. |
| Overvoltage |
115–135% of rated output voltage; Zener-diode clamp. |
| Limited power source |
LPS compliance is listed for this series. |
| Power indication |
LED indicator for power on. |
Operating Conditions and Derating
| Operating temperature |
−30 to +70°C; apply the ambient-temperature derating curve. |
| Temperature curve |
100% load from −30 to +40°C, decreasing to 50% at +70°C. |
| Input-voltage curve |
At 60 Hz: 80% load at 90 VAC, increasing to 100% at 95 VAC; 100% load from 95 to 264 VAC. |
| Operating humidity |
20–90% RH, non-condensing. |
| Storage temperature / humidity |
−20 to +85°C; 10–95% RH. |
| Temperature coefficient |
±0.03%/°C over 0–40°C. |
| Vibration |
10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. |
Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output.
Mechanical Details and Cable
| Main-body dimensions |
94 × 48.4 × 40 mm (L × W × H). Allow additional clearance for the selected AC plug and DC cable. |
| DC cable |
AWM2468 16 AWG; 1000 ±50 mm for this output-voltage version. |
| Catalogue unit weight |
200 g, catalogue packing reference per unit; not a measured net or shipping weight. |
Use the mechanical drawing on PDF page 23 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection.
Separately Ordered AC Plugs
| Australian plug |
AC PLUG-AU3, for GE40I only. |
| UK plug |
AC PLUG-UK, compatible with GE12I / GE18I / GE24I / GE30I / GE40I. |
| European plug |
AC PLUG-EU, compatible with GE12I / GE18I / GE24I / GE30I / GE40I. |
| US plug |
AC PLUG-US, compatible with GE12I / GE18I / GE24I / GE30I / GE40I. |
| Four-region set |
AC PLUG-MIX3, for GE40I: Australian AU3, UK, European and US plug types. |
Use AC PLUG-AU3 for the GE40I Australian configuration and AC PLUG-MIX3 for its four-region set. AC PLUG-MIX is for the GE12I / GE18I / GE24I / GE30I group. The GE40I Australian plug must not be used on that lower-power group.
Plug shape does not change the adapter Class II construction or create a functional-ground connection. The interchangeable AC plug and DC output connector are different parts.
Optional DC Connector Configurations
| Tuning-fork plugs |
P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. |
| Barrel plugs |
P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. |
| Locking plugs |
P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. |
| Minimum-pin plugs |
P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. |
| R6B, locking 3-pin male |
KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. |
| R7B, locking 4-pin male |
KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. |
| Stripped and tinned leads |
Lead 1, ribbed = +Vo; lead 2, lettered = −Vo. Standard illustrated lengths: L = 25 mm, L1 = 10 mm; lengths can be requested. |
These are customer-requested DC connector configurations. The listed order model has the standard P1J plug; alternative connectors are not included automatically. Confirm the exact assembly, mating dimensions, polarity and permissible current before ordering.
A different connector does not increase the adapter output rating. Select the connection for the required load and verify the cable and connector current ratings.
Safety and EMC
| Listed safety approvals |
UL62368-1, CSA C22.2, TUV EN62368-1, AS/NZS60950.1, CCC GB4943.1 and EAC TP TC 004. |
| Dielectric withstand |
Input to output: 4242 VDC. |
| Insulation resistance |
Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. |
| Conducted / radiated emissions |
EN55032 (CISPR32), Class B. |
| Harmonics / flicker |
EN61000-3-2, Class A; EN61000-3-3. |
| ESD immunity |
EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. |
| RF field / conducted RF |
EN61000-4-3: Level 2, 3 V/m; EN61000-4-6: Level 2, 3 V. |
| EFT / surge |
EN61000-4-4: Level 2, 1 kV; EN61000-4-5: Level 3, 1 kV line-to-neutral. |
| Magnetic-field immunity |
EN61000-4-8: Level 1, 1 A/m. |
| Voltage dips / interruptions |
EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. |
Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment.
Measurement Conditions and Reliability
| General test conditions |
Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. |
| DC voltage set point |
Measured at the output plug at 50% load. |
| Ripple/noise measurement |
20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. |
| MTBF, minimum |
100 thousand hours, MIL-HDBK-217F at 25°C. |
| Catalogue life condition |
2 years at 100% load, 40°C and 8 hours/day. |
| Manufacturer warranty |
2 years, subject to manufacturer warranty terms. |
| Catalogue revision |
2019-08-06; combined PDF pages 21–25. |
Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load.
Applications and Selection
Suitable application examples include consumer electronics, telecommunications equipment, office equipment and industrial equipment. Select the correct output voltage, current capacity, polarity and AC plug for the equipment and installation.