MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits.

Product Datasheet

Download MEAN WELL GP25B Datasheet (PDF)

The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation.

Model and Three-Output Rating

Complete model GP25B14E-R1B.
Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet.
Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 14E the output-voltage set; R1B the standard five-pin male DIN connector.
Catalogue-rated total output power 29 W, subject to input-voltage and ambient-temperature derating.
Efficiency, typical 80.5%.

Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances.

CH1 Output

DC output voltage +5 VDC.
Rated current 2.5 A.
Operating current range 0.5–2.5 A.
Ripple and noise, maximum 100 mVp-p.
Voltage tolerance ±5.0%.
Line regulation ±1.0%.
Load regulation ±5.0%.

CH2 Output

DC output voltage +15 VDC.
Rated current 0.8 A.
Operating current range 0.1–0.8 A.
Ripple and noise, maximum 150 mVp-p.
Voltage tolerance -5.0% to +15%.
Line regulation ±1.0%.
Load regulation ±5.0%.

CH3 Output

DC output voltage −15 VDC.
Rated current 0.3 A.
Operating current range 0.1–0.3 A.
Ripple and noise, maximum 50 mVp-p.
Voltage tolerance ±3.0%.
Line regulation ±1.0%.
Load regulation ±3.0%.

Input, Start-Up and Energy

Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz.
AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection.
Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC.
Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC.
Leakage current, maximum 0.75 mA at 240 VAC.
Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC.
No-load consumption <0.3 W.
Energy efficiency Level VI; EISA2007/DoE.

Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order.

Protection

Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed.
Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output.

Temperature, Input Derating and Environment

Working ambient −20 to +70°C, subject to the derating curve.
Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C.
Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC.
Operating humidity 20–90% RH, non-condensing.
Storage −20 to +85°C; 10–95% RH, non-condensing.
Temperature coefficient ±0.03%/°C over −20 to +40°C.
Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis.

Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure.

Mechanical Details and Installation

Dimensions, L × W × H 107.5 × 67 × 36 mm.
Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet.
Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm.
Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions.
Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight.
Packing 54 pieces / 20 kg.

Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions.

Output Connection and Optional Leads

R1B pins 1 / 2 COM / COM.
R1B pin 3 CH1, +5 VDC.
R1B pin 4 CH3, −15 VDC.
R1B pin 5 CH2, +15 VDC.
Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request.
Optional lead colour code Black and blue: COM; red: +5 V; white: −15 V; yellow: +15 V.

Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return.

Configuration Options

The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model.

The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents.

Safety and EMC

Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model.
Input-to-output withstand 4242 VDC.
Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH.
Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B.
Harmonic current BS EN/EN61000-3-2, Class A.
Voltage fluctuations and flicker BS EN/EN61000-3-3.
ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact.
Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m.
Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV.
Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral.
Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V.
Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods.

The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation.

Reliability and Measurement Conditions

MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C.
Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day.
Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms.

Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load.

Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.

Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B14E-R1B

Product form

MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class... Read more

$105.96 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits.

    Product Datasheet

    Download MEAN WELL GP25B Datasheet (PDF)

    The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation.

    Model and Three-Output Rating

    Complete model GP25B14E-R1B.
    Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet.
    Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 14E the output-voltage set; R1B the standard five-pin male DIN connector.
    Catalogue-rated total output power 29 W, subject to input-voltage and ambient-temperature derating.
    Efficiency, typical 80.5%.

    Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances.

    CH1 Output

    DC output voltage +5 VDC.
    Rated current 2.5 A.
    Operating current range 0.5–2.5 A.
    Ripple and noise, maximum 100 mVp-p.
    Voltage tolerance ±5.0%.
    Line regulation ±1.0%.
    Load regulation ±5.0%.

    CH2 Output

    DC output voltage +15 VDC.
    Rated current 0.8 A.
    Operating current range 0.1–0.8 A.
    Ripple and noise, maximum 150 mVp-p.
    Voltage tolerance -5.0% to +15%.
    Line regulation ±1.0%.
    Load regulation ±5.0%.

    CH3 Output

    DC output voltage −15 VDC.
    Rated current 0.3 A.
    Operating current range 0.1–0.3 A.
    Ripple and noise, maximum 50 mVp-p.
    Voltage tolerance ±3.0%.
    Line regulation ±1.0%.
    Load regulation ±3.0%.

    Input, Start-Up and Energy

    Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz.
    AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection.
    Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC.
    Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC.
    Leakage current, maximum 0.75 mA at 240 VAC.
    Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC.
    No-load consumption <0.3 W.
    Energy efficiency Level VI; EISA2007/DoE.

    Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order.

    Protection

    Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed.
    Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output.

    Temperature, Input Derating and Environment

    Working ambient −20 to +70°C, subject to the derating curve.
    Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C.
    Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC.
    Operating humidity 20–90% RH, non-condensing.
    Storage −20 to +85°C; 10–95% RH, non-condensing.
    Temperature coefficient ±0.03%/°C over −20 to +40°C.
    Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis.

    Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure.

    Mechanical Details and Installation

    Dimensions, L × W × H 107.5 × 67 × 36 mm.
    Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet.
    Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm.
    Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions.
    Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight.
    Packing 54 pieces / 20 kg.

    Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions.

    Output Connection and Optional Leads

    R1B pins 1 / 2 COM / COM.
    R1B pin 3 CH1, +5 VDC.
    R1B pin 4 CH3, −15 VDC.
    R1B pin 5 CH2, +15 VDC.
    Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request.
    Optional lead colour code Black and blue: COM; red: +5 V; white: −15 V; yellow: +15 V.

    Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return.

    Configuration Options

    The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model.

    The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents.

    Safety and EMC

    Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model.
    Input-to-output withstand 4242 VDC.
    Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH.
    Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B.
    Harmonic current BS EN/EN61000-3-2, Class A.
    Voltage fluctuations and flicker BS EN/EN61000-3-3.
    ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact.
    Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m.
    Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV.
    Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral.
    Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V.
    Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods.

    The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation.

    Reliability and Measurement Conditions

    MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C.
    Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day.
    Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms.

    Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load.

    Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.

    Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    Recently viewed products

      Footer image

      © 2026 MEAN WELL, ,

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • AliPay
      • Amazon
      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • USDC
      • Visa