MEAN WELL GP25B58F-R1B provides +16 V, +48 V, −16 V outputs with a catalogue-rated total of 37.77 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits.
Product Datasheet
Download MEAN WELL GP25B Datasheet (PDF)
The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation.
Model and Three-Output Rating
| Complete model |
GP25B58F-R1B. |
| Series and format |
GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. |
| Model code |
GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 58F the output-voltage set; R1B the standard five-pin male DIN connector. |
| Catalogue-rated total output power |
37.77 W, subject to input-voltage and ambient-temperature derating. |
| Efficiency, typical |
85%. |
Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances.
CH1 Output
| DC output voltage |
+16 VDC. |
| Rated current |
1.05 A. |
| Operating current range |
0.2–1.05 A. |
| Ripple and noise, maximum |
200 mVp-p. |
| Voltage tolerance |
±5.0%. |
| Line regulation |
±1.0%. |
| Load regulation |
±5.0%. |
CH2 Output
| DC output voltage |
+48 VDC. |
| Rated current |
0.087 A. |
| Operating current range |
0.017–0.087 A. Equivalent to 17–87 mA. |
| Ripple and noise, maximum |
200 mVp-p. |
| Voltage tolerance |
±5.0%. |
| Line regulation |
±1.0%. |
| Load regulation |
±5.0%. |
CH3 Output
| DC output voltage |
−16 VDC. |
| Rated current |
1.05 A. |
| Operating current range |
0.2–1.05 A. |
| Ripple and noise, maximum |
200 mVp-p. |
| Voltage tolerance |
-5.0% to +10%. |
| Line regulation |
±1.0%. |
| Load regulation |
±5.0%. |
Input, Start-Up and Energy
| Input range |
90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. |
| AC connection |
IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. |
| Input current |
0.8 A at 100 VAC; 0.4 A at 230 VAC. |
| Cold-start inrush, maximum |
30 A at 115 VAC; 60 A at 230 VAC. |
| Leakage current, maximum |
0.75 mA at 240 VAC. |
| Set-up / rise / hold-up times |
At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. |
| No-load consumption |
<0.3 W. |
| Energy efficiency |
Level VI; EISA2007/DoE. |
Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order.
Protection
| Short circuit / overload |
110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. |
Provide the load protection required for the +16 V, +48 V and −16 V outputs.
Temperature, Input Derating and Environment
| Working ambient |
−20 to +70°C, subject to the derating curve. |
| Horizontal temperature curve |
100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. |
| Input-voltage curve, 60 Hz |
90% load at 90 VAC; 100% from 100 through 264 VAC. |
| Operating humidity |
20–90% RH, non-condensing. |
| Storage |
−20 to +85°C; 10–95% RH, non-condensing. |
| Temperature coefficient |
±0.03%/°C over −20 to +40°C. |
| Vibration |
10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. |
Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure.
Mechanical Details and Installation
| Dimensions, L × W × H |
107.5 × 67 × 36 mm. |
| Enclosure and indicator |
Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. |
| Output cable |
UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. |
| Standard output plug |
R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. |
| Catalogue single-unit weight |
300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. |
| Packing |
54 pieces / 20 kg. |
Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions.
Output Connection and Optional Leads
| R1B wiring for this output set |
Confirm the supplied-unit pin assignment for +16 V, +48 V, −16 V and common before connecting the load. |
| Optional stripped and tinned output |
Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. |
Match the mating connector and harness to the supplied ±16 V / +48 V configuration. Obtain its specific wiring assignment with the order.
Configuration Options
The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model.
The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents.
Safety and EMC
| Safety standards |
IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. GP25B58F-R1B is excepted from the BS EN/EN62368-1 entry. |
| Input-to-output withstand |
4242 VDC. |
| Input-to-output insulation |
100 MΩ at 500 VDC, 25°C and 70% RH. |
| Conducted and radiated emissions |
BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. |
| Harmonic current |
BS EN/EN61000-3-2, Class A. |
| Voltage fluctuations and flicker |
BS EN/EN61000-3-3. |
| ESD immunity |
BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. |
| Radiated RF immunity |
BS EN/EN61000-4-3: Level 2, 3 V/m. |
| Electrical fast transient / burst |
BS EN/EN61000-4-4: Level 2, 1 kV. |
| Surge immunity |
BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. |
| Conducted RF immunity |
BS EN/EN61000-4-6: Level 2, 3 V. |
| Voltage dips and interruptions |
BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. |
The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation.
Reliability and Measurement Conditions
| MTBF |
620,000 hours minimum, MIL-HDBK-217F at 25°C. |
| Design-life condition |
3 years at 100% load, 40°C and 8 operating hours per day. |
| Manufacturer warranty |
The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. |
Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load.
Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.
Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.