MEAN WELL GS06E-5P1J is a GS06E single-output AC/DC wall-plug power adapter rated at 18 VDC, 0.33 A and 6 W. Its Class II construction uses an integral two-pin European mains plug without protective earth. The standard P1J output plug is center positive. Apply the stated output-current, power and ambient-temperature limits together.
Product Datasheet
Download MEAN WELL GS06E Datasheet (PDF)
The GS06E section is on PDF pages 10, 11, 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation.
Model and Configuration
| Complete order number |
GS06E-5P1J. |
| Safety model identifier |
GS06E-5. |
| Product category |
Single-Output Industrial AC/DC Wall-Plug Power Adapter. |
| AC plug / electrical class |
Two-pin European plug; Class II, no protective-earth pin. |
| No-load power |
<0.1 W. |
| Energy efficiency |
Level VI; EU ErP and Code of Conduct (CoC) Version 5. |
| Limited-power classification |
LPS (Limited Power Source), as listed in the catalogue. |
| Case |
Fully enclosed 94V-0 flame-retardant plastic case. |
Suitable applications listed for this series include consumer electronics, telecommunications, office equipment and industrial equipment.
Model-Specific DC Output
| Nominal output |
18 VDC. |
| Rated output current |
0.33 A. |
| Current range |
0.01–0.33 A. |
| Catalogue-rated output power, maximum |
6 W. |
| Ripple and noise, maximum |
150 mVp-p. |
| Voltage tolerance |
±5.0%. |
| Line regulation |
±0.5%. |
| Load regulation |
±5.0%. |
| Efficiency, typical |
81%. |
Observe the current and power limits together. The voltage set point is measured at the output connector terminals at 50% load.
Input and Timing
| AC input |
90–264 VAC; 47–63 Hz. |
| DC input |
127–370 VDC. |
| AC input current |
0.2 A at 100 VAC. |
| Inrush current, maximum |
Cold start: 30 A at 115 VAC; 50 A at 230 VAC. |
| Leakage current, maximum |
0.25 mA at 240 VAC. |
| Set-up / rise at full load |
1500 / 50 ms; standard measurement input 230 VAC. |
Protection
| Short circuit / overload |
>110% of rated output power; hiccup operation, automatically recovering when the abnormal load is removed. |
| Overvoltage |
>120% of rated output voltage; diode clamping. |
Cooling and Environmental Limits
| Working ambient |
0 to +50°C; apply derating. |
| Temperature/load curve |
100% load from 0°C to 40°C, decreasing to 70% at 50°C. |
| Input/load curve |
100% load across the specified 90–264 VAC range, subject to the temperature limits. |
| Working humidity |
20–90% RH, non-condensing. |
| Storage |
−20 to +85°C; 10–95% RH, non-condensing. |
| Temperature coefficient |
±0.03%/°C over 0–40°C. |
| Vibration |
10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. |
The maximum ambient temperature does not imply full rated load. Keep the unit within both its electrical and temperature limits.
Safety and Isolation
| Catalogue-listed safety standards |
TUV BS EN/EN62368-1 and EAC TP TC 004 approved, as listed in the specification table. |
| Input/output withstand |
4242 VDC. |
| Insulation resistance |
Input/output: 100 MΩ at 500 VDC, 25°C and 70% RH. |
Evaluate the finished equipment for its applicable safety and EMC requirements with the adapter connected in the intended configuration.
EMC
| Conducted / radiated emissions |
BS EN/EN55032 (CISPR32), Class B. |
| Harmonic current |
BS EN/EN61000-3-2, Class A. |
| Voltage flicker |
BS EN/EN61000-3-3. |
| ESD |
BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. |
| RF field susceptibility |
BS EN/EN61000-4-3: Level 2, 3 V/m. |
| EFT bursts |
BS EN/EN61000-4-4: Level 2, 1 kV. |
| Surge susceptibility |
BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. |
| Conducted susceptibility |
BS EN/EN61000-4-6: Level 2, 3 V. |
| Magnetic field immunity |
BS EN/EN61000-4-8: Level 1, 1 A/m. |
| Voltage dips / interruptions |
BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. |
Dimensions and Connections
| Dimensions, catalogue L × W × H |
32 × 66 × 42.5 mm. |
| Body outline |
66 ±1 mm long × 32 ±1 mm wide; body height 42.5 ±1 mm. The catalogue dimension field lists 32 × 66 × 42.5 mm. |
| Stepped outline / mains plug |
Stepped body height 62.5 ±1 mm; round-pin projection 19 ±0.5 mm. |
| Fixed DC cable |
UL2468, 24 AWG; 1800 mm, +150/−0 mm. |
| Standard output connector |
P1J tuning-fork plug: 5.5 mm outside diameter × 2.1 mm inside diameter × 11 ±0.5 mm length. |
| Polarity |
C+: center/inside positive, outside negative. |
Optional DC Plugs and Accessories
| Dimension order |
Outside diameter / inside diameter / insertion length, in mm. |
| Tuning-fork alternatives |
P1I: 5.5 / 2.1 / 9.5 mm; P1L: 5.5 / 2.5 / 9.5 mm; P1M: 5.5 / 2.5 / 11.0 mm; P1IR: 5.5 / 2.1 / 9.5 mm; P1JR: 5.5 / 2.1 / 11.0 mm; P1LR: 5.5 / 2.5 / 9.5 mm; P1MR: 5.5 / 2.5 / 11.0 mm. |
| Barrel alternatives |
P2I: 5.5 / 2.1 / 9.5 mm; P2J: 5.5 / 2.1 / 11.0 mm; P2L: 5.5 / 2.5 / 9.5 mm; P2M: 5.5 / 2.5 / 11.0 mm; P2IR: 5.5 / 2.1 / 9.5 mm; P2JR: 5.5 / 2.1 / 11.0 mm; P2LR: 5.5 / 2.5 / 9.5 mm; P2MR: 5.5 / 2.5 / 11.0 mm. |
| Locking alternatives |
P2S (S761K): 5.53 / 2.03 / 12.06 mm; P2K (761K): 5.53 / 2.54 / 12.06 mm; P2C (S760K): 5.53 / 2.03 / 9.52 mm; P2D (760K): 5.53 / 2.54 / 9.52 mm. SWITCHCRAFT original or equivalent. |
| Minimum-pin alternatives |
P3A: 2.35 / 0.7 / 11.0 mm; P3B: 4.0 / 1.7 / 11.0 mm; P3C: 4.75 / 1.7 / 11.0 mm. EIAJ equivalent. |
| Center-pin alternatives |
P4A: 5.5 / 3.4 / 11.0 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11.0 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11.0 mm, center pin 0.6 mm. EIAJ equivalent. |
| R6B |
Locking three-pin male mini-DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo; pin 2 −Vo. |
| R7B |
Locking four-pin male mini-DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo; pins 2 and 3 −Vo. |
| R7BF |
Locking four-pin female mini-DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo; pins 2 and 3 −Vo. |
| Stripped and tinned leads |
Custom termination: ribbed lead 1 = +Vo; letter-marked lead 2 = −Vo. Standard drawing lengths L = 25 mm and L1 = 10 mm; L1 may be customized. |
P1J is the standard termination of this order number. Factory changes to the listed plug styles are available by request with a minimum order quantity. Quick adapters are sold separately without a minimum order quantity; they are not supplied merely because a style is listed here.
The quick-adapter table lists tuning-fork, center-pin, R6B and R7B types at 7.5 A maximum, and minimum-pin P3 types at 5 A maximum. The barrel, locking, R7BF and stripped/tinned entries have no quick-adapter availability listed. A connector rating does not increase the power adapter output rating.
Choose the mating dimensions and polarity required by the equipment. Keep the load within both the power-adapter limits and the selected connector limits.
Reliability and Packing
| Minimum MTBF |
≥500 thousand hours, MIL-HDBK-217F at 25°C. |
| Catalogue single-unit weight |
100 g; explicit per-unit catalogue packing reference, not a measured shipping-package weight. |
| Carton packing |
90 pieces / 10 kg / carton. |
| Manufacturer warranty |
2 years, as stated in this catalogue. |
Measurement Conditions and Datasheet
| General measurement conditions |
Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. |
| Ripple/noise method |
20 MHz bandwidth; a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. |
| Voltage-tolerance scope |
Includes set-point error, line regulation and load regulation. |
| Regulation measurements |
Line regulation: low to high input at rated load. Load regulation: 0–100% rated load. |
| Catalogue revision |
2022-04-15; combined PDF pages 10–14. |