MEAN WELL GST360A12-C8P is a single-output desktop AC/DC power adapter rated at 12 VDC, 27.5 A and 330 W. It has a C8P DC output plug and a 3-pole IEC320-C14 inlet with Class I protective earthing. Apply the input-voltage and temperature derating limits below.
Product Datasheet
Download MEAN WELL GST360A Datasheet (PDF)
The GST360A section is on PDF pages 90, 91, 92, 93. Refer to the complete mechanical drawings and notes when planning installation.
Model and Selection
| Complete model |
GST360A12-C8P. |
| Series |
GST360A industrial desktop adapter. |
| Input construction |
Class I; 3-pole IEC320-C14, with FG. |
| DC termination |
Pins 1–4 +Vo; pins 5–8 −Vo. MOLEX 39-01-2080 equivalent. |
| Power conversion |
Universal input with built-in active PFC. |
| Enclosure and indication |
Fully enclosed 94V-0 flame-retardant plastic case; LED power-on indicator. |
| No-load consumption |
<0.5 W. |
| Energy efficiency |
Level VI. |
Select the complete model, output voltage, current capacity, connector and polarity for the load. A matching connector shape alone does not establish electrical compatibility.
Output Ratings
| Nominal output |
12 VDC. |
| Rated current |
27.5 A. |
| Output current range |
0–27.5 A. |
| Rated output power, maximum |
330 W. |
| Ripple and noise, maximum |
120 mVp-p. |
| Voltage tolerance |
±5.0%. |
| Line regulation |
±1.0%. |
| Load regulation |
±5.0%. |
| Efficiency, typical |
91% for this C8P version. |
| Peak power |
415 W for 3 seconds. This is a short-duration peak, not a continuous-output rating. |
Observe the stated current and power limits together. Unless otherwise specified, measurements use 230 VAC, rated load, 25°C and 70% RH. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input at rated load.
Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors.
The output-voltage set point is measured at the DC plug terminals with 50% load.
Input and Timing
| AC input |
85–264 VAC; 47–63 Hz. |
| DC input |
120–370 VDC. |
| Power factor, typical |
PF >0.95 at 230 VAC and PF >0.98 at 115 VAC, at full load. |
| AC current, typical |
3.8 A at 115 VAC; 2 A at 230 VAC. |
| Cold-start inrush, maximum |
95 A at 115 VAC; 120 A at 230 VAC. |
| Set-up / rise time |
2000 ms / 50 ms at 230 VAC; 2000 ms / 50 ms at 115 VAC, at full load. |
| Hold-up time, typical |
8 ms at both 230 VAC and 115 VAC, at full load. |
| Leakage current, maximum |
1.5 mA at 240 VAC. |
Set-up time is measured at the first cold start. Repeated power switching may increase the set-up time. Apply the low-input derating curve.
Protection
| Short circuit / overload |
135–155% of rated output power. Hiccup mode; automatic recovery after fault removal. |
| Overvoltage |
105–135% of rated output voltage. Output shutdown; reapply input power to recover. |
| Overtemperature |
Output shutdown; reapply input power to recover. |
Cooling and Environment
| Working ambient |
−30 to +70°C, subject to the model-specific derating curves. |
| Temperature derating |
Horizontal installation: full load from −30 to 40°C, then 80% at 50°C, 65% at 60°C and 50% at 70°C. |
| Input-voltage derating |
At 60 Hz, 70% load at 85 VAC, rising to 85% at 100 VAC; the graph holds 85% up to the 120 VAC transition, with 100% from 120 to 264 VAC. |
| Working humidity |
20–90% RH, non-condensing. |
| Storage |
−40 to +85°C; 10–95% RH, non-condensing. |
| Temperature coefficient |
±0.03%/°C over 0–40°C. |
| Vibration |
10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. |
| Altitude derating |
Above 2000 m, reduce permissible ambient temperature by 3.5°C per 1000 m for fanless operation. |
| Operating altitude |
Up to 5000 m, with altitude and temperature derating. |
| Overvoltage category |
OVC II under UL62368-1 and BS EN/EN62368-1, up to 5000 m. |
Keep the adapter unobstructed and apply both input and temperature limits. The plotted operating-temperature range is not a full-power guarantee at every input voltage.
Dimensions and Connections
| Enclosure dimensions, L × W × H |
220 × 95 × 46 mm; drawing tolerance ±1 mm. |
| Attached DC cable |
UL2464 16AWG × 6C; 1000 ±50 mm. |
| Default DC plug |
C8P: Pins 1–4 +Vo; pins 5–8 −Vo. MOLEX 39-01-2080 equivalent. |
| Grounding |
Class I, with protective earth through the 3-pole AC inlet; standard DC −V is connected to AC FG. A DC −V-to-FG isolated option is available by request; it is not the standard configuration. |
| AC cord |
The catalogue specifies the AC inlet but does not state that a detachable mains cord is included. Select a suitable region-approved cord for this inlet and load. |
Use the numbered connector drawing for orientation; do not infer pin numbers from a photograph. Match the mating connector, contacts and wire rating to the actual current. The alternative plug references below identify options, not extra items included with this adapter.
DC Connection Selection
The default C8P termination is specified for this voltage. The catalogue restricts MIC4 and C4P alternatives to 36–55 V models; select the original C8P arrangement for this 12 V model. Other terminations require a separately confirmed configuration.
Safety and EMC
| Catalogue safety approvals |
UL62368-1, CSA C22.2 No.62368-1, Dekra BS EN/EN62368-1, BSMI CNS15598-1, CCC GB4943, AS/NZS 62368.1, PSE J62368-1, BIS IS13252, KC 62368-1 and EAC TP TC 004. |
| Energy-saving compliance |
USA EISA 2007/DoE and Canada NRCan. |
| Withstand voltage |
Input/output: 3 kVAC; input/FG: 2 kVAC; output/FG: shorted. |
| Insulation resistance |
Input/output: 100 MΩ at 500 VDC, 25°C and 70% RH. |
| Conducted and radiated emissions |
Class B under BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B)/NMB-3(B); EAC TP TC 020. Also listed: CNS15936, GB17625.1 and MSIP KN32. |
| Harmonic current / flicker |
BS EN/EN61000-3-2 Class A and GB9254; BS EN/EN61000-3-3. |
| ESD immunity |
BS EN/EN61000-4-2: 15 kV air and 8 kV contact, Level 4. |
| RF field / EFT immunity |
BS EN/EN61000-4-3: 3 V/m, Level 2; -4-4: 1 kV, Level 2. |
| Surge immunity |
BS EN/EN61000-4-5: 1 kV line-to-line and 2 kV line-to-FG, Level 3. |
| Conducted / magnetic immunity |
BS EN/EN61000-4-6: 3 V, Level 2; -4-8: 3 A/m, Level 2. |
| Voltage dips and interruptions |
BS EN/EN61000-4-11: >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. |
The adapter is considered an independent unit, but the complete equipment must still be checked for compliance with applicable EMC directives in its actual installation. Use approvals applicable to the exact model and market.
Weight and Reliability
| Catalogue weight reference |
1400 g: catalogue packing reference per unit; not a measured net or shipping weight. |
| Packing |
1.4 kg per unit; 8 pieces / 12 kg / 0.82 CUFT. |
| MTBF, minimum estimates |
2068.5 thousand hours, Telcordia SR-332 (Bellcore); 269 thousand hours, MIL-HDBK-217F at 25°C. |
| Manufacturer warranty |
3-year manufacturer warranty, subject to applicable terms. |
| Catalogue revision |
2026-04-03. |
For connector orientation and complete dimensions, refer to PDF pages 90–93.