| Safety standards |
UL 8750 Type HL; CSA C22.2 No. 250.13-12; BS EN/EN 61347-1, 61347-2-13 independent and 62384; EAC TP TC 004; GB 19510.1 and 19510.14; IP67, as listed in the catalog. CCC approval is an optional request, not a guarantee of a physical mark on every unit. |
| Type HL installation condition |
For this AB option, use a built-in installation or fill the Io adjustment hole with potting compound to meet the catalog Type HL application condition for Class I, Division 2. Final luminaire suitability must be assessed. |
| Output safety designation |
SELV is marked for the H/M output ranges only; this designation is not stated for the L range. |
| Withstand voltage |
Input–output: 3.75 kVAC; input–earth: 2 kVAC; output–earth: 1.5 kVAC. |
| Isolation resistance |
100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–earth and output–earth. |
| EMC emission |
BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB 17743; GB 17625.1; EAC TP TC 020. |
| EMC immunity |
BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; EAC TP TC 020. Surge test: 4 kV line–line and 6 kV line–earth. |
| Final equipment EMC |
This driver is a component of final equipment; the complete luminaire installation must be requalified for EMC because wiring and installation affect compliance. |
| MTBF |
1772.9 thousand hours minimum, Telcordia SR-332 (Bellcore); 175.4 thousand hours minimum, MIL-HDBK-217F at 25°C. |
| Service life and warranty |
The specification lists 50,000 hours minimum; its typical-life note states more than 50,000 hours with the tc point at about 75°C or below. The catalog states a 5-year warranty, subject to the manufacturer’s warranty terms. |
| Lifetime reference curve |
Approximately 100,000 hours at Tcase ≤65°C, 70,000 at 70°C, 50,000 at 75°C and 35,000 at 80°C. These are readings of the reference curve, not an extension of the warranty or a guarantee at every operating point. |
| Measurement conditions |
Unless otherwise specified: 230 VAC input, rated output current and 25°C ambient. Typical values and example curves retain their stated test conditions. |
| Circuit operating frequencies |
Block diagram: PFC oscillator 45–50 kHz; PWM oscillator 60–130 kHz. |