MEAN WELL HRP-150-12 is a 156 W enclosed AC/DC power supply with a 12 V, 13 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover.
Product Datasheet
Download MEAN WELL HRP-150 Datasheet (PDF)
The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation.
Model Code and Configuration
| Complete model |
HRP-150-12 |
| Series |
HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. |
| Output-voltage code |
12: nominal 12 V main output. |
| Model-specific rating |
156 W at 12 V and 13 A; use the individual rating rather than the series number. |
| Configuration boundary |
No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. |
Main Output
| Nominal DC voltage |
12 V |
| Rated current |
13 A |
| Current range |
0 to 13 A |
| Rated output power |
156 W |
| Output voltage adjustment |
10.2 to 13.8 V |
| Ripple and noise, maximum |
120 mVp-p |
| Voltage tolerance |
±1.5% |
| Line regulation |
±0.3% |
| Load regulation |
±0.5% |
| Efficiency, typical |
88% |
| Setup / rise time |
3000 ms / 50 ms at both 230 VAC and 115 VAC, full load |
| Hold-up time, typical |
16 ms at 230 VAC; 16 ms at 115 VAC, full load |
Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel.
Input and Power Conversion
| Input range |
85 to 264 VAC, universal full range; 120 to 370 VDC |
| AC frequency |
47 to 63 Hz |
| Power factor, typical |
>0.95 at 230 VAC; >0.99 at 115 VAC, full load |
| Input current, typical |
1.7 A at 115 VAC; 0.9 A at 230 VAC |
| Inrush current, typical |
35 A at 115 VAC; 70 A at 230 VAC |
| Leakage current |
<1 mA at 240 VAC |
| Short-duration input withstand |
300 VAC for 5 seconds; this is not the continuous input range |
| PFC and inrush limiting |
Built-in active PFC and active inrush-current limiting (block diagram) |
| PWM switching frequency |
70 kHz for this output-voltage branch |
Protection
| Short circuit / overload |
105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. |
| Over-voltage trip range |
14.4 to 16.8 V |
| Over-voltage recovery |
Output shuts down; remove and restore input power to recover. |
| Over-temperature protection |
Output shuts down and recovers automatically after temperature falls. |
Power Connections
| Terminal 1 |
AC/L |
| Terminal 2 |
AC/N |
| Terminal 3 |
FG / protective earth |
| Terminals 4 and 5 |
DC output -V |
| Terminals 6 and 7 |
DC output +V |
Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals.
Signal Connector and Mating Parts
| CN100 pin 1 |
-S: negative remote sense |
| CN100 pin 2 |
+S: positive remote sense |
| CN100 pins 3 to 6 |
NC; leave unconnected |
| CN100 connector |
HRS DF11-6DP-2DSA or equivalent |
| Mating housing |
HRS DF11-6DS or equivalent |
| Mating contact family, as printed |
HRS DF11-**SC or equivalent |
The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity.
Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions.
Functional Scope
This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models.
Environment and Derating
| Cooling |
Free-air convection; fanless, 1U low-profile construction |
| Working ambient temperature |
-40 to 70 °C; use the derating conditions below |
| Working humidity |
20% to 90% RH, non-condensing |
| Storage temperature / humidity |
-50 to 85 °C; 10% to 95% RH |
| Temperature coefficient |
±0.04%/°C over 0°C to 50°C |
| Vibration test |
10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z |
| Thermal derating |
Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. |
| Low-input derating |
At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. |
| Above 2000 m altitude |
Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. |
Dimensions and Installation
| Body dimensions, L x W x H |
159 x 97 x 38 mm |
| Drawing case and tolerance |
Case 901I; dimensions in mm, tolerance ±1 mm |
| Voltage adjustment |
SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. |
| Base-view threaded holes |
2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge |
| Side-view threaded holes |
6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing |
| Other mounting references |
3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm |
| Terminal-side projection |
10 mm maximum, separately dimensioned from the 159 mm body length |
The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout.
Safety, EMC and Reliability
| Safety standards |
UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. |
| Dielectric withstand |
Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC |
| Isolation resistance |
100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH |
| EMC emission |
BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 |
| EMC immunity |
BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 |
| MTBF, minimum |
1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C |
This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise.
Weight Reference and Manufacturer Notes
| Per-unit catalog packing reference |
0.61 kg (610 g); not a separately measured net weight |
| Full packing entry |
0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT |
| Manufacturer warranty statement |
The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. |
| Catalog revision / pages |
2026-04-03; PDF pages 5, 6 |
Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient.
Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.
The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-12; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.