MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-12

Description

MEAN WELL HRP-200-12 is an enclosed single-output AC/DC power supply rated at 12 V, 16.7 A and 200.4 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together.

Product Datasheet

Download MEAN WELL HRP-200 Datasheet (PDF)

The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation.

Model and Rated Output

Complete model HRP-200-12
Rated DC output 12 V / 16.7 A / 200.4 W
Output current range 0 to 16.7 A
Local voltage adjustment 10.2 to 13.8 V
Ripple and noise, maximum 120 mVp-p
Voltage tolerance ±1.0%
Line regulation ±0.3%
Load regulation ±0.5%
Efficiency, typical 88% at 230 VAC, rated load and 25°C

HRP-200 is the series designation; the final 12 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.4 W.

Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel.

Input and Timing

Input voltage 85 to 264 VAC / 120 to 370 VDC
AC frequency 47 to 63 Hz
Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load
AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC
Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC
Leakage current <1.2 mA at 240 VAC
Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load
Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load

The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency.

The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well.

Protection

Protection functions Short circuit, overload, overvoltage and overtemperature
Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed
Overvoltage threshold 14.4 to 16.8 V
Overvoltage response Output shuts down; re-power to recover
Overtemperature response Output shuts down; automatic recovery after the temperature goes down

The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating.

Cooling and Operating Conditions

Cooling Free-air convection; fanless
Working ambient temperature -40 to +70°C with load derating
Working humidity 20 to 90% RH, non-condensing
Storage temperature / humidity -40 to +85°C / 10 to 95% RH
Temperature coefficient ±0.03%/°C from 0 to 50°C
Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z

The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition.

For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating.

Remote Sense

CN100 pin 5 / pin 6 +S / -S

Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring.

Terminals and Connector Selection

Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V
CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S
CN100 header reference HRS DF11-6DP-2DS or equivalent
Mating-housing reference HRS DF11-6DS or equivalent
Contact reference HRS DF11-**SC or equivalent

Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix.

The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected.

Dimensions and Installation

Body dimensions, L × W × H 199 × 98 × 38 mm
Case / drawing tolerance 902E / ±1 mm
Terminal projection 13 mm maximum, as dimensioned
Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups
Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm
Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations.

Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws.

The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct.

Safety, EMC and Integration

Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1
Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC
Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG

EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020.

EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020.

This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly.

Weight, Reliability and Catalogue Reference

Catalogue packing reference per unit 0.77 kg / 770 g
Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT
MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C
Manufacturer warranty statement 5 years, as listed for this series
Printed datasheet revision 2026-04-03

The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-12

Product form

MEAN WELL HRP-200-12 is an enclosed single-output AC/DC power supply rated at 12 V, 16.7 A and 200.4 W, with... Read more

$161.66 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL HRP-200-12 is an enclosed single-output AC/DC power supply rated at 12 V, 16.7 A and 200.4 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together.

    Product Datasheet

    Download MEAN WELL HRP-200 Datasheet (PDF)

    The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation.

    Model and Rated Output

    Complete model HRP-200-12
    Rated DC output 12 V / 16.7 A / 200.4 W
    Output current range 0 to 16.7 A
    Local voltage adjustment 10.2 to 13.8 V
    Ripple and noise, maximum 120 mVp-p
    Voltage tolerance ±1.0%
    Line regulation ±0.3%
    Load regulation ±0.5%
    Efficiency, typical 88% at 230 VAC, rated load and 25°C

    HRP-200 is the series designation; the final 12 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.4 W.

    Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel.

    Input and Timing

    Input voltage 85 to 264 VAC / 120 to 370 VDC
    AC frequency 47 to 63 Hz
    Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load
    AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC
    Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC
    Leakage current <1.2 mA at 240 VAC
    Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load
    Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load

    The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency.

    The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well.

    Protection

    Protection functions Short circuit, overload, overvoltage and overtemperature
    Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed
    Overvoltage threshold 14.4 to 16.8 V
    Overvoltage response Output shuts down; re-power to recover
    Overtemperature response Output shuts down; automatic recovery after the temperature goes down

    The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating.

    Cooling and Operating Conditions

    Cooling Free-air convection; fanless
    Working ambient temperature -40 to +70°C with load derating
    Working humidity 20 to 90% RH, non-condensing
    Storage temperature / humidity -40 to +85°C / 10 to 95% RH
    Temperature coefficient ±0.03%/°C from 0 to 50°C
    Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z

    The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition.

    For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating.

    Remote Sense

    CN100 pin 5 / pin 6 +S / -S

    Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring.

    Terminals and Connector Selection

    Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V
    CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S
    CN100 header reference HRS DF11-6DP-2DS or equivalent
    Mating-housing reference HRS DF11-6DS or equivalent
    Contact reference HRS DF11-**SC or equivalent

    Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix.

    The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected.

    Dimensions and Installation

    Body dimensions, L × W × H 199 × 98 × 38 mm
    Case / drawing tolerance 902E / ±1 mm
    Terminal projection 13 mm maximum, as dimensioned
    Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups
    Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm
    Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations.

    Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws.

    The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct.

    Safety, EMC and Integration

    Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1
    Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC
    Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG

    EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020.

    EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020.

    This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly.

    Weight, Reliability and Catalogue Reference

    Catalogue packing reference per unit 0.77 kg / 770 g
    Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT
    MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C
    Manufacturer warranty statement 5 years, as listed for this series
    Printed datasheet revision 2026-04-03

    The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.