MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-5

Description

MEAN WELL HRPG-150-5 is a 130 W enclosed AC/DC power supply with a 5 V, 26 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below.

Product Datasheet

Download MEAN WELL HRPG-150 Datasheet (PDF)

The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation.

Model Code and Configuration

Complete model HRPG-150-5
Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage.
Output-voltage code 5: nominal 5 V main output.
Model-specific rating 130 W at 5 V and 26 A; use the individual rating rather than the series number.
HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments.

Main Output

Nominal DC voltage 5 V
Rated current 26 A
Current range 0 to 26 A
Rated output power 130 W
Output voltage adjustment 4.3 to 5.8 V
Ripple and noise, maximum 80 mVp-p
Voltage tolerance ±2.5%
Line regulation ±0.5%
Load regulation ±1.0%
Efficiency, typical 84%
Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load
Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load

Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel.

Input and Power Conversion

Input range 85 to 264 VAC, universal full range; 120 to 370 VDC
AC frequency 47 to 63 Hz
Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load
Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC
Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC
Leakage current <1 mA at 240 VAC
Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range
PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram)
PWM switching frequency 100 kHz for this output-voltage branch

Protection

Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed.
Over-voltage trip range 6 to 7 V
Over-voltage recovery Output shuts down; remove and restore input power to recover.
Over-temperature protection Output shuts down and recovers automatically after temperature falls.

Power Connections

Terminal 1 AC/L
Terminal 2 AC/N
Terminal 3 FG / protective earth
Terminals 4 and 5 DC output -V
Terminals 6 and 7 DC output +V

Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals.

Signal Connector and Mating Parts

CN100 pin 1 -S: negative remote sense
CN100 pin 2 +S: positive remote sense
CN100 pin 3 AUXG: isolated auxiliary-output return
CN100 pin 4 AUX: 5 V standby output, referenced to pin 3
CN100 pin 5 RC-: remote-control ground
CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5
CN100 connector HRS DF11-6DP-2DSA or equivalent
Mating housing HRS DF11-6DS or equivalent
Mating contact family, as printed HRS DF11-**SC or equivalent

The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity.

Remote Sense, Standby and ON/OFF

Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair.
Maximum sense compensation 0.5 V line drop
Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum
Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3)
Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF.
Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5
Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5
No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted

The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages.

Environment and Derating

Cooling Free-air convection; fanless, 1U low-profile construction
Working ambient temperature -40 to 70 °C; use the derating conditions below
Working humidity 20% to 90% RH, non-condensing
Storage temperature / humidity -40 to 85 °C; 10% to 95% RH
Temperature coefficient ±0.04%/°C over 0°C to 50°C
Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z
Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit.
Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits.
Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages.
Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A.

Dimensions and Installation

Body dimensions, L x W x H 159 x 97 x 38 mm
Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm
Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range.
Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge
Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing
Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm
Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length

The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout.

Safety, EMC and Reliability

Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series.
Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC
Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH
EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020
EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020
MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C

This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise.

Weight Reference and Manufacturer Notes

Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight
Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT
Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment.
Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9

Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient.

Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-5

Product form

MEAN WELL HRPG-150-5 is a 130 W enclosed AC/DC power supply with a 5 V, 26 A main output, active... Read more

$147.36 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL HRPG-150-5 is a 130 W enclosed AC/DC power supply with a 5 V, 26 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below.

    Product Datasheet

    Download MEAN WELL HRPG-150 Datasheet (PDF)

    The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation.

    Model Code and Configuration

    Complete model HRPG-150-5
    Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage.
    Output-voltage code 5: nominal 5 V main output.
    Model-specific rating 130 W at 5 V and 26 A; use the individual rating rather than the series number.
    HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments.

    Main Output

    Nominal DC voltage 5 V
    Rated current 26 A
    Current range 0 to 26 A
    Rated output power 130 W
    Output voltage adjustment 4.3 to 5.8 V
    Ripple and noise, maximum 80 mVp-p
    Voltage tolerance ±2.5%
    Line regulation ±0.5%
    Load regulation ±1.0%
    Efficiency, typical 84%
    Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load
    Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load

    Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel.

    Input and Power Conversion

    Input range 85 to 264 VAC, universal full range; 120 to 370 VDC
    AC frequency 47 to 63 Hz
    Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load
    Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC
    Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC
    Leakage current <1 mA at 240 VAC
    Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range
    PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram)
    PWM switching frequency 100 kHz for this output-voltage branch

    Protection

    Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed.
    Over-voltage trip range 6 to 7 V
    Over-voltage recovery Output shuts down; remove and restore input power to recover.
    Over-temperature protection Output shuts down and recovers automatically after temperature falls.

    Power Connections

    Terminal 1 AC/L
    Terminal 2 AC/N
    Terminal 3 FG / protective earth
    Terminals 4 and 5 DC output -V
    Terminals 6 and 7 DC output +V

    Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals.

    Signal Connector and Mating Parts

    CN100 pin 1 -S: negative remote sense
    CN100 pin 2 +S: positive remote sense
    CN100 pin 3 AUXG: isolated auxiliary-output return
    CN100 pin 4 AUX: 5 V standby output, referenced to pin 3
    CN100 pin 5 RC-: remote-control ground
    CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5
    CN100 connector HRS DF11-6DP-2DSA or equivalent
    Mating housing HRS DF11-6DS or equivalent
    Mating contact family, as printed HRS DF11-**SC or equivalent

    The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity.

    Remote Sense, Standby and ON/OFF

    Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair.
    Maximum sense compensation 0.5 V line drop
    Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum
    Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3)
    Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF.
    Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5
    Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5
    No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted

    The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages.

    Environment and Derating

    Cooling Free-air convection; fanless, 1U low-profile construction
    Working ambient temperature -40 to 70 °C; use the derating conditions below
    Working humidity 20% to 90% RH, non-condensing
    Storage temperature / humidity -40 to 85 °C; 10% to 95% RH
    Temperature coefficient ±0.04%/°C over 0°C to 50°C
    Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z
    Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit.
    Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits.
    Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages.
    Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A.

    Dimensions and Installation

    Body dimensions, L x W x H 159 x 97 x 38 mm
    Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm
    Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range.
    Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge
    Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing
    Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm
    Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length

    The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout.

    Safety, EMC and Reliability

    Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series.
    Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC
    Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH
    EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020
    EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020
    MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C

    This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise.

    Weight Reference and Manufacturer Notes

    Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight
    Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT
    Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment.
    Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9

    Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient.

    Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.