MEAN WELL HRPG-200-7.5 is an enclosed single-output AC/DC power supply rated at 7.5 V, 26.7 A and 200.3 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together.
Product Datasheet
Download MEAN WELL HRPG-200 Datasheet (PDF)
The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation.
Model and Rated Output
| Complete model |
HRPG-200-7.5 |
| Rated DC output |
7.5 V / 26.7 A / 200.3 W |
| Output current range |
0 to 26.7 A |
| Local voltage adjustment |
6.8 to 9 V |
| Ripple and noise, maximum |
100 mVp-p |
| Voltage tolerance |
±2.0% |
| Line regulation |
±0.5% |
| Load regulation |
±1.0% |
| Efficiency, typical |
86% at 230 VAC, rated load and 25°C |
HRPG-200 is the series designation; the final 7.5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.3 W.
Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel.
Input and Timing
| Input voltage |
85 to 264 VAC / 120 to 370 VDC |
| AC frequency |
47 to 63 Hz |
| Power factor, typical |
>0.95 at 230 VAC; >0.99 at 115 VAC, at full load |
| AC current, typical |
2.1 A at 115 VAC; 1.1 A at 230 VAC |
| Inrush current, typical |
35 A at 115 VAC; 70 A at 230 VAC |
| Leakage current |
<1.2 mA at 240 VAC |
| Setup / rise time |
1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load |
| Hold-up time, typical |
16 ms at both 230 VAC and 115 VAC, at full load |
The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency.
The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well.
Protection
| Protection functions |
Short circuit, overload, overvoltage and overtemperature |
| Overload |
105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed |
| Overvoltage threshold |
9.4 to 10.9 V |
| Overvoltage response |
Output shuts down; re-power to recover |
| Overtemperature response |
Output shuts down; automatic recovery after the temperature goes down |
The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating.
Cooling and Operating Conditions
| Cooling |
Free-air convection; fanless |
| Working ambient temperature |
-40 to +70°C with load derating |
| Working humidity |
20 to 90% RH, non-condensing |
| Storage temperature / humidity |
-40 to +85°C / 10 to 95% RH |
| Temperature coefficient |
±0.03%/°C from 0 to 50°C |
| Vibration |
10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z |
The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition.
For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating.
Remote Sense, ON/OFF and Standby
| Remote-sense connection |
CN100 pin 5: +S; pin 6: -S |
| Line-drop compensation |
Up to 0.5 V |
| Remote-control connection |
CN100 pin 1: RC+; pin 2: RC- |
| Main output ON |
RC+ to RC-: 4 to 10 V, or open contact |
| Main output OFF |
RC+ to RC-: 0 to 0.8 V, or shorted contact |
| Standby output |
CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A |
| Standby accuracy / ripple |
4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple |
| No-load power consumption |
<0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit |
Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path.
The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON.
Terminals and Connector Selection
| Power terminals |
1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V |
| CN100 signal assignment |
pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S |
| CN100 header reference |
HRS DF11-6DP-2DS or equivalent |
| Mating-housing reference |
HRS DF11-6DS or equivalent |
| Contact reference |
HRS DF11-**SC or equivalent |
Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix.
The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected.
Dimensions and Installation
| Body dimensions, L × W × H |
199 × 98 × 38 mm |
| Case / drawing tolerance |
902E / ±1 mm |
| Terminal projection |
13 mm maximum, as dimensioned |
| Mounting callouts |
4-M3 L=5 and 3-M3 L=5 at the indicated groups |
| Selected hole-centre dimensions |
Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm |
| Power-terminal drawing dimensions |
The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. |
Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws.
The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct.
Safety, EMC and Integration
| Approved standards listed for this model |
UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 |
| Withstand voltage |
Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC |
| Insulation resistance |
100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG |
EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020.
EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020.
This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly.
Weight, Reliability and Catalogue Reference
| Catalogue packing reference per unit |
0.77 kg / 770 g |
| Catalogue carton data |
18 pieces / 14.9 kg / 0.87 CUFT |
| MTBF, minimum prediction |
1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C |
| Manufacturer warranty statement |
5 years, as listed for this series |
| Printed datasheet revision |
2026-04-03 |
The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.