MEAN WELL HVGC-650 series: Constant Power LED Driver - HVGC-650A-U-DA

Description

HVGC-650A-U-DA LED Driver

MEAN WELL HVGC-650A-U-DA is a 649.6 W constant-power LED driver with 11200 mA rated current and a 24–58 V constant-current operating region. This IP67 Class I metal-case version provides dali control and output-current potentiometer and a 12 V / 200 mA auxiliary output. Select the LED operating point within the model-specific I–V envelope; current and voltage limits cannot be combined arbitrarily.

Catalog: HVGC-650, PDF pages 57–66, revision 2026-02-09.

Model selection

Full model and series HVGC-650A-U-DA; HVGC-650
Suffix and configuration DALI control and output-current potentiometer. By-request catalog execution; confirm the exact supplied build.
Construction and IP rating IP67; metal housing; Class I protective-earth design; active PFC; fanless free-air convection cooling.
Auxiliary-output identity The A immediately after 650 identifies the auxiliary-output version. Nominal 12 V ±10%, 200 mA; ripple and noise 150 mVp-p. Keep this circuit separate from the LED output and control interface.
Applications Harbor, LED high-bay, parking-lot, fishing-lamp, horticulture and stadium lighting. Subject to the final luminaire design.

Output specifications

Rated output current 11200 mA
Rated output power 649.6 W
Constant-current voltage region 24–58 V
Full-power current range 11200–14000 mA
Maximum open-circuit voltage 70 V
Catalog current-adjustment range 5600–14000 mA. Use only the adjustment/control method specified for this suffix.
Recommended operating envelope Match the LED forward-voltage sum and selected current to the shaded I–V region in the catalog, within the rated power limit. Key plotted current / voltage points: 5600 mA / 58 V; 11200 mA / 58 V; 14000 mA / 46.4 V; 11200 mA / 29 V.
Current tolerance and ripple Current tolerance ±5%; current ripple 5.0% maximum at rated current.
Efficiency (typical) 95.5%
Temperature coefficient ±0.03%/°C over 0–55°C
Lower-voltage source qualification The specification table gives 24–58 V. The I–V illustration labels one corner 23.2 V; these differ. Keep the specified 24 V lower limit unless MEAN WELL confirms a different approved operating point.

Input and performance

Input voltage and frequency 180–528 VAC or 254–747 VDC; 47–63 Hz AC.
Input current (typical) 2.1 A at 347 VAC; 1.5 A at 480 VAC
Power factor (typical) ≥0.98 / ≥0.98 / ≥0.97 / ≥0.96 / ≥0.95 at 230 / 277 / 347 / 400 / 480 VAC respectively, full load.
Total harmonic distortion THD <20% at load ≥50% on 230 / 277 / 347 / 400 / 480 VAC.
Setup time 500 ms at 230, 347 and 480 VAC. Measured at the first cold start; turning power on/off may increase setup time.
Inrush current (typical) Cold start: 40 A, pulse width 1250 µs measured at 50% Ipeak at 480 VAC, per NEMA 410.
Circuit-breaker reference 2 units on a 16 A type B breaker; 4 units on a 16 A type C breaker at 480 VAC. These are catalog reference limits; verify the actual breaker and installation conditions.
Leakage current <0.75 mA at 480 VAC
Input/load characteristic At 60 Hz, 80% load at 180 VAC, increasing to 100% at 200 VAC; 100% through 528 VAC. Apply thermal limits separately.

Protection

Short-circuit protection Constant-current limiting; automatically recovers after the fault is removed.
Over-voltage protection 62–78 V; output voltage shuts down; cycle input power to recover.
Over-temperature protection Output voltage shuts down; cycle input power to recover.

Adjustment and control

Digital dimming interface DALI technology controlled on the primary side; 16 groups and 64 addresses.
Dimming first step 6% fixed at the first step when the controller sends a command.
Local current adjustment The constant-current level is adjustable through the built-in Io ADJ potentiometer within the catalog range.
Digital control wiring Connect the compatible bus to DA+ purple and DA− pink as shown in the dedicated mechanical drawing. These are digital-control conductors, not the analog DIM or timer PROG interface.

Thermal and environmental conditions

Case operating temperature Tcase −40 to +85°C; maximum case temperature +85°C. This is not the ambient-temperature limit.
Cooling and ambient derating Horizontal mounting and free-air convection. At 200 VAC, 100% load through +45°C, then 60% at +50°C; at 230 VAC, 100% through +50°C, then 60% at +55°C; above 277 VAC, 100% through +55°C, then 60% at +60°C. The curves stop at these endpoints. At rated current in the constant-power region, maximum workable ambient temperature is +50°C typical at 230 VAC.
Case-temperature load curve The horizontal-mounting case-temperature curve shows 100% load through +85°C and stops there. Observe both case and ambient limits.
Altitude derating Above 2000 m (6500 ft), reduce allowable ambient temperature by 3.5°C per additional 1000 m for this fanless driver.
Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C and 10–95% RH, non-condensing.
Vibration 10–500 Hz, 5G; 12 minutes per cycle; 72 minutes along each X, Y and Z axis.
Typical lifetime >50,000 hours when Tcase, particularly the tc / TMP point, is about +80°C or less. Lifetime varies with temperature; use the dedicated curve, not an unconditional service-life guarantee.
MTBF 728.1K h minimum, Telcordia SR-332 (Bellcore); 60.2K h minimum, MIL-HDBK-217F at 25°C
Warranty Manufacturer catalog: 5-year warranty, subject to MEAN WELL’s warranty statement.

Safety and EMC

Safety standards UL8750 (Type HL); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-2-13; EAC TP TC 004.
Type HL application For use in Class I, Division 2 hazardous-location lighting equipment under the applicable final-system requirements. Type HL is not a standalone explosion-proof classification.
Dielectric withstand Input/output: 4.2 kVAC; input/FG: 2.1 kVAC; output/FG: 1.5 kVAC.
Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH.
Safety source qualification The safety row additionally prints “BS EN/EN60384”. Verify the applicable certificate with MEAN WELL; this text is not silently changed to a different standard.
SELV scope The HVGC-650 series cover identifies SELV only for H and U output ranges; this U model is within that stated range.
EMC emission BS EN/EN55015; BS EN/EN61000-3-2 Class C at load ≥50%; BS EN/EN61000-3-3; FCC Part 15 Class B; EAC TP TC 020.
EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN61547, light-industry level; EAC TP TC 020. Surge: 8 kV line-to-earth / 4 kV line-to-line.

Mechanical and wiring

Dimensions and enclosure 280 × 144 × 48.5 mm (L × W × H); case no. 228; drawing tolerance ±1 mm.
Mounting four Ø4.5 mm mounting features; main case body length excluding end flanges 253.2 mm. Use the exact drawing for fixing geometry.
Case-temperature measuring point the tc point is 126.6 mm from the right inner end line and 47 mm from the lower edge.
Input cable SOOW 17 AWG × 3 conductors / H07RN-F 3 × 1.0 mm²; brown AC/L, blue AC/N, green/yellow FG protective earth. the drawing gives 300 ±20 mm.
Output cable SJOW 17 AWG × 4 conductors / H05RN-F; red Vo+, black Vo−. the output lead drawing gives 300 ±20 mm.
Unit mass and packing Catalog packing reference: 3.9 kg per unit; 4 pcs / 16.6 kg / 0.98 CUFT per carton. This is the stated per-unit reference, not a carton-weight average.
Four-conductor output The U output uses two red positive and two black negative conductors for the same LED output; these are not independent channels.
Control cable SJOW 17 AWG × 2 conductors / H05RN-F; DA+ purple, DA− pink. Use the supplied drawing for lead length; no separate control-lead dimension is assigned here.
Auxiliary cable SJOW 17 AWG × 2 conductors / H05RN-F; AUX+ gray, AUX− black; 300 ±20 mm in the auxiliary-output drawing.

Installation

Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself.
Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements.
System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system.
Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person.
Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications.
Protective-earth installation Connect the fitted FG/PE conductor to PE according to this Class I model’s wiring diagram.
Weather protection This model is IP67 with an adjustment function and must be installed indoors or in a location sheltered from rain outdoors, as required by the installation manual. The IP rating does not permit immersion.
Digital-controller installation This DA option uses DALI, with the control cable identified as DA+ and DA−. Verify the supplied wiring and compatible controller/network; do not treat these terminals as the analog DIM or timer PROG interface. If standalone dimming conductors smaller than 18 AWG are used, use only SELV controllers or networks and contact MEAN WELL before using FELV control.
Auxiliary-output identity The A suffix immediately after 650 identifies the auxiliary-output version. Its auxiliary output is 12 V at 200 mA, with AUX+ gray and AUX− black. Keep the auxiliary circuit separate from the LED power and control interfaces and within its stated rating.
Input switching For the catalog ErP condition, use this driver behind a switch; do not connect it permanently to the mains.

Specification conditions

Measurement conditions Unless otherwise stated: 347 VAC input, rated current and +25°C ambient.
Performance plots Power-factor curves are shown at Tcase +80°C. THD and efficiency plots illustrate the L output range at Tcase +80°C; use this exact model’s table values and stated load/input limits.
Accessories and supplied configuration The applicable catalog pages do not identify a separately orderable dedicated connector or programmer code. Confirm any required programming equipment or custom build with MEAN WELL; accessories are not implied by the model description.

MEAN WELL HVGC-650 series: Constant Power LED Driver - HVGC-650A-U-DA

Product form

HVGC-650A-U-DA LED Driver MEAN WELL HVGC-650A-U-DA is a 649.6 W constant-power LED driver with 11200 mA rated current and a... Read more

$557.42 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    HVGC-650A-U-DA LED Driver

    MEAN WELL HVGC-650A-U-DA is a 649.6 W constant-power LED driver with 11200 mA rated current and a 24–58 V constant-current operating region. This IP67 Class I metal-case version provides dali control and output-current potentiometer and a 12 V / 200 mA auxiliary output. Select the LED operating point within the model-specific I–V envelope; current and voltage limits cannot be combined arbitrarily.

    Catalog: HVGC-650, PDF pages 57–66, revision 2026-02-09.

    Model selection

    Full model and series HVGC-650A-U-DA; HVGC-650
    Suffix and configuration DALI control and output-current potentiometer. By-request catalog execution; confirm the exact supplied build.
    Construction and IP rating IP67; metal housing; Class I protective-earth design; active PFC; fanless free-air convection cooling.
    Auxiliary-output identity The A immediately after 650 identifies the auxiliary-output version. Nominal 12 V ±10%, 200 mA; ripple and noise 150 mVp-p. Keep this circuit separate from the LED output and control interface.
    Applications Harbor, LED high-bay, parking-lot, fishing-lamp, horticulture and stadium lighting. Subject to the final luminaire design.

    Output specifications

    Rated output current 11200 mA
    Rated output power 649.6 W
    Constant-current voltage region 24–58 V
    Full-power current range 11200–14000 mA
    Maximum open-circuit voltage 70 V
    Catalog current-adjustment range 5600–14000 mA. Use only the adjustment/control method specified for this suffix.
    Recommended operating envelope Match the LED forward-voltage sum and selected current to the shaded I–V region in the catalog, within the rated power limit. Key plotted current / voltage points: 5600 mA / 58 V; 11200 mA / 58 V; 14000 mA / 46.4 V; 11200 mA / 29 V.
    Current tolerance and ripple Current tolerance ±5%; current ripple 5.0% maximum at rated current.
    Efficiency (typical) 95.5%
    Temperature coefficient ±0.03%/°C over 0–55°C
    Lower-voltage source qualification The specification table gives 24–58 V. The I–V illustration labels one corner 23.2 V; these differ. Keep the specified 24 V lower limit unless MEAN WELL confirms a different approved operating point.

    Input and performance

    Input voltage and frequency 180–528 VAC or 254–747 VDC; 47–63 Hz AC.
    Input current (typical) 2.1 A at 347 VAC; 1.5 A at 480 VAC
    Power factor (typical) ≥0.98 / ≥0.98 / ≥0.97 / ≥0.96 / ≥0.95 at 230 / 277 / 347 / 400 / 480 VAC respectively, full load.
    Total harmonic distortion THD <20% at load ≥50% on 230 / 277 / 347 / 400 / 480 VAC.
    Setup time 500 ms at 230, 347 and 480 VAC. Measured at the first cold start; turning power on/off may increase setup time.
    Inrush current (typical) Cold start: 40 A, pulse width 1250 µs measured at 50% Ipeak at 480 VAC, per NEMA 410.
    Circuit-breaker reference 2 units on a 16 A type B breaker; 4 units on a 16 A type C breaker at 480 VAC. These are catalog reference limits; verify the actual breaker and installation conditions.
    Leakage current <0.75 mA at 480 VAC
    Input/load characteristic At 60 Hz, 80% load at 180 VAC, increasing to 100% at 200 VAC; 100% through 528 VAC. Apply thermal limits separately.

    Protection

    Short-circuit protection Constant-current limiting; automatically recovers after the fault is removed.
    Over-voltage protection 62–78 V; output voltage shuts down; cycle input power to recover.
    Over-temperature protection Output voltage shuts down; cycle input power to recover.

    Adjustment and control

    Digital dimming interface DALI technology controlled on the primary side; 16 groups and 64 addresses.
    Dimming first step 6% fixed at the first step when the controller sends a command.
    Local current adjustment The constant-current level is adjustable through the built-in Io ADJ potentiometer within the catalog range.
    Digital control wiring Connect the compatible bus to DA+ purple and DA− pink as shown in the dedicated mechanical drawing. These are digital-control conductors, not the analog DIM or timer PROG interface.

    Thermal and environmental conditions

    Case operating temperature Tcase −40 to +85°C; maximum case temperature +85°C. This is not the ambient-temperature limit.
    Cooling and ambient derating Horizontal mounting and free-air convection. At 200 VAC, 100% load through +45°C, then 60% at +50°C; at 230 VAC, 100% through +50°C, then 60% at +55°C; above 277 VAC, 100% through +55°C, then 60% at +60°C. The curves stop at these endpoints. At rated current in the constant-power region, maximum workable ambient temperature is +50°C typical at 230 VAC.
    Case-temperature load curve The horizontal-mounting case-temperature curve shows 100% load through +85°C and stops there. Observe both case and ambient limits.
    Altitude derating Above 2000 m (6500 ft), reduce allowable ambient temperature by 3.5°C per additional 1000 m for this fanless driver.
    Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C and 10–95% RH, non-condensing.
    Vibration 10–500 Hz, 5G; 12 minutes per cycle; 72 minutes along each X, Y and Z axis.
    Typical lifetime >50,000 hours when Tcase, particularly the tc / TMP point, is about +80°C or less. Lifetime varies with temperature; use the dedicated curve, not an unconditional service-life guarantee.
    MTBF 728.1K h minimum, Telcordia SR-332 (Bellcore); 60.2K h minimum, MIL-HDBK-217F at 25°C
    Warranty Manufacturer catalog: 5-year warranty, subject to MEAN WELL’s warranty statement.

    Safety and EMC

    Safety standards UL8750 (Type HL); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-2-13; EAC TP TC 004.
    Type HL application For use in Class I, Division 2 hazardous-location lighting equipment under the applicable final-system requirements. Type HL is not a standalone explosion-proof classification.
    Dielectric withstand Input/output: 4.2 kVAC; input/FG: 2.1 kVAC; output/FG: 1.5 kVAC.
    Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH.
    Safety source qualification The safety row additionally prints “BS EN/EN60384”. Verify the applicable certificate with MEAN WELL; this text is not silently changed to a different standard.
    SELV scope The HVGC-650 series cover identifies SELV only for H and U output ranges; this U model is within that stated range.
    EMC emission BS EN/EN55015; BS EN/EN61000-3-2 Class C at load ≥50%; BS EN/EN61000-3-3; FCC Part 15 Class B; EAC TP TC 020.
    EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN61547, light-industry level; EAC TP TC 020. Surge: 8 kV line-to-earth / 4 kV line-to-line.

    Mechanical and wiring

    Dimensions and enclosure 280 × 144 × 48.5 mm (L × W × H); case no. 228; drawing tolerance ±1 mm.
    Mounting four Ø4.5 mm mounting features; main case body length excluding end flanges 253.2 mm. Use the exact drawing for fixing geometry.
    Case-temperature measuring point the tc point is 126.6 mm from the right inner end line and 47 mm from the lower edge.
    Input cable SOOW 17 AWG × 3 conductors / H07RN-F 3 × 1.0 mm²; brown AC/L, blue AC/N, green/yellow FG protective earth. the drawing gives 300 ±20 mm.
    Output cable SJOW 17 AWG × 4 conductors / H05RN-F; red Vo+, black Vo−. the output lead drawing gives 300 ±20 mm.
    Unit mass and packing Catalog packing reference: 3.9 kg per unit; 4 pcs / 16.6 kg / 0.98 CUFT per carton. This is the stated per-unit reference, not a carton-weight average.
    Four-conductor output The U output uses two red positive and two black negative conductors for the same LED output; these are not independent channels.
    Control cable SJOW 17 AWG × 2 conductors / H05RN-F; DA+ purple, DA− pink. Use the supplied drawing for lead length; no separate control-lead dimension is assigned here.
    Auxiliary cable SJOW 17 AWG × 2 conductors / H05RN-F; AUX+ gray, AUX− black; 300 ±20 mm in the auxiliary-output drawing.

    Installation

    Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself.
    Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements.
    System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system.
    Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person.
    Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications.
    Protective-earth installation Connect the fitted FG/PE conductor to PE according to this Class I model’s wiring diagram.
    Weather protection This model is IP67 with an adjustment function and must be installed indoors or in a location sheltered from rain outdoors, as required by the installation manual. The IP rating does not permit immersion.
    Digital-controller installation This DA option uses DALI, with the control cable identified as DA+ and DA−. Verify the supplied wiring and compatible controller/network; do not treat these terminals as the analog DIM or timer PROG interface. If standalone dimming conductors smaller than 18 AWG are used, use only SELV controllers or networks and contact MEAN WELL before using FELV control.
    Auxiliary-output identity The A suffix immediately after 650 identifies the auxiliary-output version. Its auxiliary output is 12 V at 200 mA, with AUX+ gray and AUX− black. Keep the auxiliary circuit separate from the LED power and control interfaces and within its stated rating.
    Input switching For the catalog ErP condition, use this driver behind a switch; do not connect it permanently to the mains.

    Specification conditions

    Measurement conditions Unless otherwise stated: 347 VAC input, rated current and +25°C ambient.
    Performance plots Power-factor curves are shown at Tcase +80°C. THD and efficiency plots illustrate the L output range at Tcase +80°C; use this exact model’s table values and stated load/input limits.
    Accessories and supplied configuration The applicable catalog pages do not identify a separately orderable dedicated connector or programmer code. Confirm any required programming equipment or custom build with MEAN WELL; accessories are not implied by the model description.