MEAN WELL LAD series: UPS function economical safety control fire power supply - LAD-360BU

Description

Output channel: CH1 Output voltage: 27.6V Rated output current: 11.5A Output current range: 0 ~ 13A Output power rating: 358.8W Input voltage: 90 ~ 132VAC/180 ~ 264VAC adjustable by switch, 240 ~ 370VDC (default setting 230VAC) Size (mm):215X115X30 UART signal only

Product Features

1. International universal full range input (120W:90 ~ 264VAC,240~600W:115/230 switch switching).

2. Single-group output with battery charging control, UPS function can be formed by external battery, and TTL signal of detection state is built in:

3. AC OK, battery not connected, battery reverse connected, battery undervoltage, battery full and standby.

4. UART communication (LAD-360/600 U-type version only), with built-in main and standby power circuit switches to enhance maintenance safety.

5. The output voltage of CH1 (-20+5%) can be adjusted by VR, and the built-in peak sound warning (only LAD-360/600 U-type version).

6. Forced start UPS mode is used for battery maintenance. Protection types: short circuit/overload/overvoltage/overtemperature/battery undervoltage/battery reverse connection (will not be damaged).

7, -20 ~ +60 ℃ working temperature, the design conforms to the GB17945 of fire regulations.

8. 1U ultra-thin height (30mm),3-year warranty.

MEAN WELL LAD series: UPS function economical safety control fire power supply - LAD-360BU

Product form

Output channel: CH1 Output voltage: 27.6V Rated output current: 11.5A Output current range: 0 ~ 13A Output power rating: 358.8W... Read more

$121.29 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    Output channel: CH1 Output voltage: 27.6V Rated output current: 11.5A Output current range: 0 ~ 13A Output power rating: 358.8W Input voltage: 90 ~ 132VAC/180 ~ 264VAC adjustable by switch, 240 ~ 370VDC (default setting 230VAC) Size (mm):215X115X30 UART signal only

    Product Features

    1. International universal full range input (120W:90 ~ 264VAC,240~600W:115/230 switch switching).

    2. Single-group output with battery charging control, UPS function can be formed by external battery, and TTL signal of detection state is built in:

    3. AC OK, battery not connected, battery reverse connected, battery undervoltage, battery full and standby.

    4. UART communication (LAD-360/600 U-type version only), with built-in main and standby power circuit switches to enhance maintenance safety.

    5. The output voltage of CH1 (-20+5%) can be adjusted by VR, and the built-in peak sound warning (only LAD-360/600 U-type version).

    6. Forced start UPS mode is used for battery maintenance. Protection types: short circuit/overload/overvoltage/overtemperature/battery undervoltage/battery reverse connection (will not be damaged).

    7, -20 ~ +60 ℃ working temperature, the design conforms to the GB17945 of fire regulations.

    8. 1U ultra-thin height (30mm),3-year warranty.