MEAN WELL LDH-45A-500DA is a fully encapsulated DC/DC step-up constant-current LED driver with 500 mA rated output, a 24–86 VDC LED operating window and 43 W rated power. This pin-style version uses 9–18 VDC input and provides DALI dimming. Select the LED string so its voltage stays within the stated window and is at least 12 V above the actual input voltage.
Combined catalog pages 7–11; LDH-45 revision 2024-10-16.
| DC input / reference voltage |
9–18 VDC operating range; 12 VDC rated/reference input. Observe input polarity and the load limits below. |
| Typical input current |
4.1 A at the catalog reference conditions. |
| Efficiency specification / plots |
The specification table lists 90% in its “EFFICIENCY (max.)” row. Page 10 separately plots the LDH-45A-500 example at 12 VDC input and LED Vf = 3.33 V; those illustrative curves vary with LED count and can show higher local values. Use the table entry as the stated specification; the example peaks are not a guaranteed efficiency for every load or suffix. |
| Input-voltage loading |
A-input curve: 75% load at 9 VDC, rising to 100% at 12 VDC; 100% from 12 to 18 VDC. |
| Polarity / wiring voltage drop |
Connect positive and negative input terminals correctly. Do not apply negative input voltage. Account for the voltage drop of the supply wiring at the operating input current. |
| Reference measurement conditions |
Unless otherwise stated: normal 12 VDC input, rated load, +25°C and 70% RH ambient. |
| Short-circuit protection |
The catalog specifies “Power OFF and fuse open.” No automatic short-circuit recovery is specified. |
| Maximum overvoltage protection |
100 V. Protection holds a constant output voltage and shuts off output current; it recovers automatically after the fault is removed. |
| Undervoltage protection |
Undervoltage protection is listed among the series features. No separate trip threshold or recovery value is specified in this catalog; operate within the stated input range. |
| Cooling / ambient limits |
Free-air convection. The shared specification gives −40 to +70°C, subject to the derating graph. For this A-input branch, the 100% load curve extends from −40 to +60°C and ends there. The A curve does not authorize operation from +60 to +70°C. |
| Humidity / storage |
Working humidity: 20–90% RH, non-condensing. Storage: −40 to +85°C and 10–95% RH. |
| Temperature coefficient |
±0.03%/°C over 0–50°C. |
| Vibration |
10–500 Hz, 2G; 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. |
| Dimensions / construction |
75 × 53 × 22.7 mm (L × W × H); fully encapsulated. Mechanical drawing tolerance: ±1 mm. |
| Input / output connections |
Bottom-view pins: 1 Vin+; 2 Vin−; 6 Vout−; 7 Vout+. Follow the numbered bottom-view drawing when designing the mating board. Do not connect Vin− to Vout−; connect the LED string to Vout+ and Vout−. |
| Control connections |
Pins: 3 DA−; 4 DA+; no pin 5. |
| Wire / pin dimensions |
Pin diameter: 1.0 mm ±0.05 mm; the side view shows 3.5 mm pin projection. Use the bottom-view drawing for exact pin coordinates. |
| Soldering limits |
Catalog maximums: wave soldering 265°C for 5 seconds; manual soldering 390°C for 3 seconds. |
| DC input polarity and wiring drop |
Connect the positive and negative DC input terminals correctly. Do not apply a negative input voltage. Account for voltage drop in the input wiring because the input current can be high. |
| Input and output separation |
Do not connect Vin- to Vout-. Follow the pin or lead-wire diagram for this exact model; identical wire colors do not make the input and output negative connections interchangeable. |
| Dim-off output voltage |
When dimmed off, the output voltage falls to approximately the input voltage. Complete darkness requires an LED string that remains off at that input voltage; dim-off is not a zero-output-voltage isolation state. |
| Battery and DC-bus EMC |
The catalogue states battery-source compliance with BS EN/EN 55015 without additional input filters or capacitors. A DC-bus source requires the model-specific additional EMC filter circuit shown in the catalogue. |
| Installation reference scope |
The catalogue links the general LED installation manual, whose family list does not explicitly name LDH. Use this DC model's specific pinout and application limits; the general manual does not establish AC wiring or circuit-breaker ratings for this unit. |
| Short-circuit limitation |
The specified short-circuit response is power off with the fuse open. Automatic short-circuit recovery is not specified. |
| DALI connection boundary |
Use the DA- and DA+ connections for this DALI version; pin 5 is absent. The catalogue lists 16 groups and 64 addresses, with a minimum dimming level of about 8%. The analogue and PWM input specifications belong to the non-DA version. |
| Output headroom |
The output must be at least 12 V above the DC input for this DALI version, within the model-specific output-voltage range. |
| Safety approvals |
LVD BS EN/EN 61347-1, BS EN/EN 61347-2-13, and EAC TP TC 004 approved. The DALI marking on the cover is specifically for DA types. |
| EMC emission / immunity |
Emission: BS EN/EN 55015 and EAC TP TC 020. Immunity: BS EN/EN 61547; BS EN/EN 61000-4-2, -3, -4, -6 and -8, light-industry level; EAC TP TC 020. |
| Battery / DC-bus EMC conditions |
For battery supply, the catalog states compliance with BS EN/EN 55015 without additional input filter and capacitors. For DC-bus supply, additional EMC filter components are required; follow the page 11 circuit and validate the complete installation. |
| Recommended EMC circuit |
Page 11 shows C1 = 47 µF across the DC-source lines, LF1 = 47 mH in the supply/input path, and LF2 = 10.4 mH between the controller and dimming connection. |
| MTBF |
12195.2 thousand hours minimum: Telcordia SR-332 (Bellcore); 1179.3 thousand hours minimum: MIL-HDBK-217F at 25°C. |
| Unit mass / warranty |
138 g, the catalog PACKING reference per unit; not a measured shipping-package weight. The catalog states a 3-year manufacturer warranty, subject to the manufacturer’s terms. |