MEAN WELL LRS-200N2-12 is a single-output enclosed switching power supply with a 12 V DC output, 17 A rated current and 204 W rated output power. This N2 version supports short-duration peak loads within the input-voltage, duty-cycle and average-power limits below. 115/230 VAC selector switch. Free-air convection; no fan.

Download MEAN WELL LRS-200N2 Datasheet (PDF)

The combined LRS catalog includes this series on PDF pages 34–38. Specifications: page 35; mechanical drawing: page 38.

Model and Output Specifications

Complete model LRS-200N2-12
Series LRS-200N2
Output-voltage code 12 = 12 V DC nominal output
N2 version High-peak-power version; see the peak-load limits for this series.
Rated output voltage 12 V DC
Rated output current 17 A
Output current range 0 to 17 A
Rated output power 204 W
Output voltage adjustment 10.2 to 13.8 V
Ripple and noise, maximum 150 mVp-p
Voltage tolerance ±1.5%
Line regulation ±0.5%
Load regulation ±1.0%
Efficiency, typical 87.5% at the stated test conditions

230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

Input and Timing

AC input range 90 to 132 VAC / 180 to 264 VAC
Input range selection 115/230 VAC selector switch
DC input range 240 to 370 VDC. Set switch to 230 VAC for DC input.
Input frequency 47 to 63 Hz
AC input current, typical 4.1A/115VAC 2.4A/230VAC
Inrush current, typical Cold start 60A/115VAC 60A/230VAC
Leakage current <2mA / 240VAC
Setup / rise time 1300 / 50 ms at 230 VAC; 1300 / 50 ms at 115 VAC, full load
Hold-up time, typical 16 ms at 230 VAC; 12 ms at 115 VAC, full load
Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

Select the correct 115/230 VAC input range before energizing the supply. For DC input, the selector must be set to 230 VAC.

Protection and Recovery

Short-circuit protection Included
Sustained overload Output power >105% rated for more than 5 seconds: shut down output; re-power on to recover.
Above 200% rated output power Hiccup mode; automatically recovers after fault condition is removed.
Overvoltage protection 13.8 to 16.2 V. Shut down and latch off output; re-power on to recover.
Thermal protection Shut down and latch off output; re-power on to recover.

Short-Duration Peak Loads

Maximum peak capability Up to 200% of rated output power, limited by the input-voltage/peak-power curve
Peak duration 5 seconds maximum per pulse
Duty at the 200% operating point 20% maximum according to the family duty curve; the input-voltage curve must also allow this peak
Other peak operating points Apply the corresponding duty curve; the overall duty ceiling is 35%
Cycle-average power Must not exceed 204 W rated output power
Duty and average-power calculation Duty = t/T × 100%. Average power = [Ppeak × t + Pnon-peak × (T − t)] / T. Here t is peak duration and T is the full cycle period.

All limits apply together. Input voltage, operating temperature, non-peak load and cycle time determine the usable peak. Check the graphs and function manual on PDF page 37; a 200% capability does not permit continuous operation at twice rated power.

Environment and Cooling

Ambient operating temperature -25 to 70 °C; apply the temperature and input-voltage derating curves
Cooling Free-air convection; no fan
Working humidity 20 ~ 90% RH non-condensing
Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH
Temperature coefficient ±0.03%/°C (0 ~ 50°C)
Operating altitude Up to 2,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.

Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 36 for this model and installation orientation.

Dimensions and Installation

Overall dimensions (L × W × H) 215 × 115 × 30 mm
Case number 207
Drawing tolerance ±1 mm
Mounting-hole callouts 4-M4 L=3mm; 4-M4(Both Sides) L=5mm
Terminal 1 AC/L
Terminal 2 AC/N
Terminal 3 FG (protective earth)
Terminal 4~6 DC OUTPUT -V
Terminal 7~9 DC OUTPUT +V

Use the mechanical drawing on PDF page 38 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep ventilation openings clear for convection cooling.

This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

Reference Weight

Catalog reference per unit 660 g

This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

Application and Datasheet Notes

The manufacturer states that this supply does not meet EN61000-3-2 harmonic-current requirements. Do not use it in end equipment within the European Union that is connected to public mains rated at 220 VAC or above when the end equipment has average or continuous input power greater than 75 W, or when it forms part of a lighting system. The datasheet lists exceptions for professional equipment with total rated input power greater than 1,000 W and for symmetrically controlled heating elements rated at 200 W or less. Confirm the applicability to the complete end equipment.

EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

Additional Manufacturer Data

Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
MTBF reference 2089.1K hrs min. Telcordia SR-332 (Bellcore) ; 243.6Khrs min. MIL-HDBK-217F (25°C)
Dielectric withstand I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Power indication LED power-on indicator
Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

Source: MEAN WELL LRS-200N2 datasheet, revision 2025-09-12, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.

MEAN WELL LRS-200N2 series: high-peak enclosed AC/DC switching power supply - LRS-200N2-12

Product form

MEAN WELL LRS-200N2-12 is a single-output enclosed switching power supply with a 12 V DC output, 17 A rated current... Read more

$54.21 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL LRS-200N2-12 is a single-output enclosed switching power supply with a 12 V DC output, 17 A rated current and 204 W rated output power. This N2 version supports short-duration peak loads within the input-voltage, duty-cycle and average-power limits below. 115/230 VAC selector switch. Free-air convection; no fan.

    Download MEAN WELL LRS-200N2 Datasheet (PDF)

    The combined LRS catalog includes this series on PDF pages 34–38. Specifications: page 35; mechanical drawing: page 38.

    Model and Output Specifications

    Complete model LRS-200N2-12
    Series LRS-200N2
    Output-voltage code 12 = 12 V DC nominal output
    N2 version High-peak-power version; see the peak-load limits for this series.
    Rated output voltage 12 V DC
    Rated output current 17 A
    Output current range 0 to 17 A
    Rated output power 204 W
    Output voltage adjustment 10.2 to 13.8 V
    Ripple and noise, maximum 150 mVp-p
    Voltage tolerance ±1.5%
    Line regulation ±0.5%
    Load regulation ±1.0%
    Efficiency, typical 87.5% at the stated test conditions

    230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

    Input and Timing

    AC input range 90 to 132 VAC / 180 to 264 VAC
    Input range selection 115/230 VAC selector switch
    DC input range 240 to 370 VDC. Set switch to 230 VAC for DC input.
    Input frequency 47 to 63 Hz
    AC input current, typical 4.1A/115VAC 2.4A/230VAC
    Inrush current, typical Cold start 60A/115VAC 60A/230VAC
    Leakage current <2mA / 240VAC
    Setup / rise time 1300 / 50 ms at 230 VAC; 1300 / 50 ms at 115 VAC, full load
    Hold-up time, typical 16 ms at 230 VAC; 12 ms at 115 VAC, full load
    Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

    Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

    Select the correct 115/230 VAC input range before energizing the supply. For DC input, the selector must be set to 230 VAC.

    Protection and Recovery

    Short-circuit protection Included
    Sustained overload Output power >105% rated for more than 5 seconds: shut down output; re-power on to recover.
    Above 200% rated output power Hiccup mode; automatically recovers after fault condition is removed.
    Overvoltage protection 13.8 to 16.2 V. Shut down and latch off output; re-power on to recover.
    Thermal protection Shut down and latch off output; re-power on to recover.

    Short-Duration Peak Loads

    Maximum peak capability Up to 200% of rated output power, limited by the input-voltage/peak-power curve
    Peak duration 5 seconds maximum per pulse
    Duty at the 200% operating point 20% maximum according to the family duty curve; the input-voltage curve must also allow this peak
    Other peak operating points Apply the corresponding duty curve; the overall duty ceiling is 35%
    Cycle-average power Must not exceed 204 W rated output power
    Duty and average-power calculation Duty = t/T × 100%. Average power = [Ppeak × t + Pnon-peak × (T − t)] / T. Here t is peak duration and T is the full cycle period.

    All limits apply together. Input voltage, operating temperature, non-peak load and cycle time determine the usable peak. Check the graphs and function manual on PDF page 37; a 200% capability does not permit continuous operation at twice rated power.

    Environment and Cooling

    Ambient operating temperature -25 to 70 °C; apply the temperature and input-voltage derating curves
    Cooling Free-air convection; no fan
    Working humidity 20 ~ 90% RH non-condensing
    Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH
    Temperature coefficient ±0.03%/°C (0 ~ 50°C)
    Operating altitude Up to 2,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
    Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.

    Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 36 for this model and installation orientation.

    Dimensions and Installation

    Overall dimensions (L × W × H) 215 × 115 × 30 mm
    Case number 207
    Drawing tolerance ±1 mm
    Mounting-hole callouts 4-M4 L=3mm; 4-M4(Both Sides) L=5mm
    Terminal 1 AC/L
    Terminal 2 AC/N
    Terminal 3 FG (protective earth)
    Terminal 4~6 DC OUTPUT -V
    Terminal 7~9 DC OUTPUT +V

    Use the mechanical drawing on PDF page 38 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep ventilation openings clear for convection cooling.

    This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

    Reference Weight

    Catalog reference per unit 660 g

    This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

    Application and Datasheet Notes

    The manufacturer states that this supply does not meet EN61000-3-2 harmonic-current requirements. Do not use it in end equipment within the European Union that is connected to public mains rated at 220 VAC or above when the end equipment has average or continuous input power greater than 75 W, or when it forms part of a lighting system. The datasheet lists exceptions for professional equipment with total rated input power greater than 1,000 W and for symmetrically controlled heating elements rated at 200 W or less. Confirm the applicability to the complete end equipment.

    EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

    Additional Manufacturer Data

    Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
    MTBF reference 2089.1K hrs min. Telcordia SR-332 (Bellcore) ; 243.6Khrs min. MIL-HDBK-217F (25°C)
    Dielectric withstand I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
    Power indication LED power-on indicator
    Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

    MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

    Source: MEAN WELL LRS-200N2 datasheet, revision 2025-09-12, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.

    Recently viewed products

      Footer image

      © 2026 MEAN WELL, ,

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • AliPay
      • Amazon
      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • USDC
      • Visa