MEAN WELL LRS-450 series: enclosed AC/DC switching power supply - LRS-450-5

Description

MEAN WELL LRS-450-5 is a single-output enclosed switching power supply with a 5 V DC output, 75 A rated current and 375 W rated output power. 115/230 VAC selector switch. Forced air cooling by built-in DC fan.

Download MEAN WELL LRS-450 Datasheet (PDF)

The combined LRS catalog includes this series on PDF pages 48–51. Specifications: page 49; mechanical drawing: page 51.

Model and Output Specifications

Complete model LRS-450-5
Series LRS-450
Output-voltage code 5 = 5 V DC nominal output
Rated output voltage 5 V DC
Rated output current 75 A
Output current range 0 to 75 A
Rated output power 375 W
Output voltage adjustment 4.75 to 5.5 V
Ripple and noise, maximum 200 mVp-p
Voltage tolerance ±2.0%
Line regulation ±0.5%
Load regulation ±2.0%
Efficiency, typical 87% at the stated test conditions

230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

Voltage tolerance includes setup tolerance, line regulation and load regulation. Line regulation is measured from low to high input at rated load; load regulation is measured from 0% to 100% rated load.

Adjust output voltage only with input at 100–120 VAC or 200–240 VAC. Adjustment outside these input ranges may cause abnormal output.

Input and Timing

AC input range 90 to 132 VAC / 180 to 264 VAC
Input range selection 115/230 VAC selector switch
DC input range 255 to 370 VDC. Set switch to 230 VAC for DC input.
Input frequency 47 to 63 Hz
AC input current, typical 10A/115VAC 6A/230VAC
Inrush current, typical 35A/115VAC 60A/230VAC
Leakage current <2mA / 240VAC
Setup / rise time 1500 / 50 ms at 230 VAC; 1500 / 50 ms at 115 VAC, full load
Hold-up time, typical 16 ms at 230 VAC; 12 ms at 115 VAC, full load
Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

Select the correct 115/230 VAC input range before energizing the supply. For DC input, the selector must be set to 230 VAC.

Protection and Recovery

Short-circuit protection Included
Overload 105 to 150% of rated output power. Constant-current limiting; shuts down after 3 seconds; re-power on to recover.
Overvoltage protection 5.75 to 6.75 V. Shut down output; re-power on to recover.
Thermal protection Shut down output; re-power on to recover.
Restart after protection Allow 3 minutes of cool-down, typical, before restarting.

Environment and Cooling

Ambient operating temperature -20 to 70 °C; apply the temperature and input-voltage derating curves
Cooling Forced air cooling by built-in DC fan
Working humidity 20 ~ 90% RH non-condensing
Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH
Temperature coefficient ±0.03%/°C (0 ~ 50°C)
Fan control, typical Internal RTH3 sensor: fan on at ≥50 °C and off at ≤40 °C. These are internal sensor temperatures, not ambient-temperature setpoints.
Operating altitude Up to 5,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.
Higher-altitude temperature derating For operation above 2,000 m, reduce the permitted ambient temperature by 5 °C per additional 1,000 m. Verify the applicable insulation/approval limits for the installation.

Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 50 for this model and installation orientation.

Dimensions and Installation

Overall dimensions (L × W × H) 225 × 124 × 35 mm
Case number 291
Drawing tolerance ±1 mm
Mounting-hole callouts 4-M4 L=3mm; 4-M4(Both Sides) L=6mm
Terminal 1 AC/L
Terminal 2 AC/N
Terminal 3 FG (protective earth)
Terminal 4~6 DC OUTPUT -V
Terminal 7~9 DC OUTPUT +V

Use the mechanical drawing on PDF page 51 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep the ventilation path and the airflow direction shown in the drawing clear.

This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

Reference Weight

Catalog reference per unit 850 g

This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

Application and Datasheet Notes

The manufacturer states that this supply does not meet EN61000-3-2 harmonic-current requirements. Do not use it in end equipment within the European Union that is connected to public mains rated at 220 VAC or above when the end equipment has average or continuous input power greater than 75 W, or when it forms part of a lighting system. The datasheet lists exceptions for professional equipment with total rated input power greater than 1,000 W and for symmetrically controlled heating elements rated at 200 W or less. Confirm the applicability to the complete end equipment.

EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

Additional Manufacturer Data

Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
MTBF reference 1508.9K hrs min. Telcordia SR-332(Bellcore) ; 252.2K hrs min. MIL-HDBK-217F (25°C)
Dielectric withstand I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

Source: MEAN WELL LRS-450 datasheet, revision 2025-09-12, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.

MEAN WELL LRS-450 series: enclosed AC/DC switching power supply - LRS-450-5

Product form

MEAN WELL LRS-450-5 is a single-output enclosed switching power supply with a 5 V DC output, 75 A rated current... Read more

$131.59 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL LRS-450-5 is a single-output enclosed switching power supply with a 5 V DC output, 75 A rated current and 375 W rated output power. 115/230 VAC selector switch. Forced air cooling by built-in DC fan.

    Download MEAN WELL LRS-450 Datasheet (PDF)

    The combined LRS catalog includes this series on PDF pages 48–51. Specifications: page 49; mechanical drawing: page 51.

    Model and Output Specifications

    Complete model LRS-450-5
    Series LRS-450
    Output-voltage code 5 = 5 V DC nominal output
    Rated output voltage 5 V DC
    Rated output current 75 A
    Output current range 0 to 75 A
    Rated output power 375 W
    Output voltage adjustment 4.75 to 5.5 V
    Ripple and noise, maximum 200 mVp-p
    Voltage tolerance ±2.0%
    Line regulation ±0.5%
    Load regulation ±2.0%
    Efficiency, typical 87% at the stated test conditions

    230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

    Voltage tolerance includes setup tolerance, line regulation and load regulation. Line regulation is measured from low to high input at rated load; load regulation is measured from 0% to 100% rated load.

    Adjust output voltage only with input at 100–120 VAC or 200–240 VAC. Adjustment outside these input ranges may cause abnormal output.

    Input and Timing

    AC input range 90 to 132 VAC / 180 to 264 VAC
    Input range selection 115/230 VAC selector switch
    DC input range 255 to 370 VDC. Set switch to 230 VAC for DC input.
    Input frequency 47 to 63 Hz
    AC input current, typical 10A/115VAC 6A/230VAC
    Inrush current, typical 35A/115VAC 60A/230VAC
    Leakage current <2mA / 240VAC
    Setup / rise time 1500 / 50 ms at 230 VAC; 1500 / 50 ms at 115 VAC, full load
    Hold-up time, typical 16 ms at 230 VAC; 12 ms at 115 VAC, full load
    Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

    Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

    Select the correct 115/230 VAC input range before energizing the supply. For DC input, the selector must be set to 230 VAC.

    Protection and Recovery

    Short-circuit protection Included
    Overload 105 to 150% of rated output power. Constant-current limiting; shuts down after 3 seconds; re-power on to recover.
    Overvoltage protection 5.75 to 6.75 V. Shut down output; re-power on to recover.
    Thermal protection Shut down output; re-power on to recover.
    Restart after protection Allow 3 minutes of cool-down, typical, before restarting.

    Environment and Cooling

    Ambient operating temperature -20 to 70 °C; apply the temperature and input-voltage derating curves
    Cooling Forced air cooling by built-in DC fan
    Working humidity 20 ~ 90% RH non-condensing
    Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH
    Temperature coefficient ±0.03%/°C (0 ~ 50°C)
    Fan control, typical Internal RTH3 sensor: fan on at ≥50 °C and off at ≤40 °C. These are internal sensor temperatures, not ambient-temperature setpoints.
    Operating altitude Up to 5,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
    Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.
    Higher-altitude temperature derating For operation above 2,000 m, reduce the permitted ambient temperature by 5 °C per additional 1,000 m. Verify the applicable insulation/approval limits for the installation.

    Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 50 for this model and installation orientation.

    Dimensions and Installation

    Overall dimensions (L × W × H) 225 × 124 × 35 mm
    Case number 291
    Drawing tolerance ±1 mm
    Mounting-hole callouts 4-M4 L=3mm; 4-M4(Both Sides) L=6mm
    Terminal 1 AC/L
    Terminal 2 AC/N
    Terminal 3 FG (protective earth)
    Terminal 4~6 DC OUTPUT -V
    Terminal 7~9 DC OUTPUT +V

    Use the mechanical drawing on PDF page 51 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep the ventilation path and the airflow direction shown in the drawing clear.

    This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

    Reference Weight

    Catalog reference per unit 850 g

    This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

    Application and Datasheet Notes

    The manufacturer states that this supply does not meet EN61000-3-2 harmonic-current requirements. Do not use it in end equipment within the European Union that is connected to public mains rated at 220 VAC or above when the end equipment has average or continuous input power greater than 75 W, or when it forms part of a lighting system. The datasheet lists exceptions for professional equipment with total rated input power greater than 1,000 W and for symmetrically controlled heating elements rated at 200 W or less. Confirm the applicability to the complete end equipment.

    EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

    Additional Manufacturer Data

    Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
    MTBF reference 1508.9K hrs min. Telcordia SR-332(Bellcore) ; 252.2K hrs min. MIL-HDBK-217F (25°C)
    Dielectric withstand I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
    Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

    MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

    Source: MEAN WELL LRS-450 datasheet, revision 2025-09-12, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.