MEAN WELL LRS-75 series: enclosed AC/DC switching power supply - LRS-75-15

Description

MEAN WELL LRS-75-15 is a single-output enclosed switching power supply with a 15 V DC output, 5 A rated current and 75 W rated output power. Universal AC input / full range. Free-air convection; no fan.

Download MEAN WELL LRS-75 Datasheet (PDF)

The combined LRS catalog includes this series on PDF pages 9–12. Specifications: page 10; mechanical drawing: page 12.

Model and Output Specifications

Complete model LRS-75-15
Series LRS-75
Output-voltage code 15 = 15 V DC nominal output
Rated output voltage 15 V DC
Rated output current 5 A
Output current range 0 to 5 A
Rated output power 75 W
Output voltage adjustment 13.5 to 18 V
Ripple and noise, maximum 120 mVp-p
Voltage tolerance ±1.0%
Line regulation ±0.5%
Load regulation ±0.5%
Efficiency, typical 89% at the stated test conditions

230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

Voltage tolerance includes setup tolerance, line regulation and load regulation. Line regulation is measured from low to high input at rated load; load regulation is measured from 0% to 100% rated load.

Input and Timing

AC input range 85 to 264 VAC
Input range selection Universal AC input / full range
DC input range 120 to 373 VDC
Input frequency 47 to 63 Hz
AC input current, typical 1.4A/115VAC 0.85A/230VAC
Inrush current, typical Cold start 65A/230VAC
Leakage current <0.75mA / 240VAC
Setup / rise time 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC, full load
Hold-up time, typical 60 ms at 230 VAC; 12 ms at 115 VAC, full load
Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

Protection and Recovery

Short-circuit protection Included
Overload 110 to 150% of rated output power. Hiccup; automatically recovers after fault condition is removed.
Overvoltage protection 18.75 to 21.75 V. Shut down output; re-power on to recover.

Environment and Cooling

Ambient operating temperature -30 to 70 °C; apply the temperature and input-voltage derating curves
Cooling Free-air convection; no fan
Working humidity 20 ~ 90% RH non-condensing
Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH non-condensing
Temperature coefficient ±0.03%/°C (0 ~ 50°C)
Operating altitude Up to 5,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.
Higher-altitude temperature derating For operation above 2,000 m, reduce the permitted ambient temperature by 5 °C per additional 1,000 m. Verify the applicable insulation/approval limits for the installation.

Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 11 for this model and installation orientation.

Dimensions and Installation

Overall dimensions (L × W × H) 99 × 97 × 30 mm
Case number 240A
Drawing tolerance ±1 mm
Mounting-hole callouts 2-M3 L=3.0; 2-M3 L=5
Terminal 1 AC/L
Terminal 2 AC/N
Terminal 3 FG (protective earth)
Terminal 4 DC OUTPUT -V
Terminal 5 DC OUTPUT +V

Use the mechanical drawing on PDF page 12 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep ventilation openings clear for convection cooling.

This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

Reference Weight

Catalog reference per unit 230 g

This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

Application and Datasheet Notes

EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

Additional Manufacturer Data

Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
MTBF reference 3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 667.2Khrs min. MIL-HDBK-217F (25°C)
Dielectric withstand I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Power indication LED power-on indicator
Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

Source: MEAN WELL LRS-75 datasheet, revision 2025-04-07, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.

MEAN WELL LRS-75 series: enclosed AC/DC switching power supply - LRS-75-15

Product form

MEAN WELL LRS-75-15 is a single-output enclosed switching power supply with a 15 V DC output, 5 A rated current... Read more

$30.06 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL LRS-75-15 is a single-output enclosed switching power supply with a 15 V DC output, 5 A rated current and 75 W rated output power. Universal AC input / full range. Free-air convection; no fan.

    Download MEAN WELL LRS-75 Datasheet (PDF)

    The combined LRS catalog includes this series on PDF pages 9–12. Specifications: page 10; mechanical drawing: page 12.

    Model and Output Specifications

    Complete model LRS-75-15
    Series LRS-75
    Output-voltage code 15 = 15 V DC nominal output
    Rated output voltage 15 V DC
    Rated output current 5 A
    Output current range 0 to 5 A
    Rated output power 75 W
    Output voltage adjustment 13.5 to 18 V
    Ripple and noise, maximum 120 mVp-p
    Voltage tolerance ±1.0%
    Line regulation ±0.5%
    Load regulation ±0.5%
    Efficiency, typical 89% at the stated test conditions

    230 VAC input, rated load, 25°C ambient unless otherwise stated. Ripple/noise test: 20 MHz bandwidth; 12-inch twisted-pair wire terminated with 0.1 µF and 47 µF parallel capacitors.

    Voltage tolerance includes setup tolerance, line regulation and load regulation. Line regulation is measured from low to high input at rated load; load regulation is measured from 0% to 100% rated load.

    Input and Timing

    AC input range 85 to 264 VAC
    Input range selection Universal AC input / full range
    DC input range 120 to 373 VDC
    Input frequency 47 to 63 Hz
    AC input current, typical 1.4A/115VAC 0.85A/230VAC
    Inrush current, typical Cold start 65A/230VAC
    Leakage current <0.75mA / 240VAC
    Setup / rise time 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC, full load
    Hold-up time, typical 60 ms at 230 VAC; 12 ms at 115 VAC, full load
    Transient input withstand 300 VAC for 5 seconds; this is a surge condition, not the continuous input rating

    Full load; setup at cold first start. Rapid on/off cycling can increase setup time.

    Protection and Recovery

    Short-circuit protection Included
    Overload 110 to 150% of rated output power. Hiccup; automatically recovers after fault condition is removed.
    Overvoltage protection 18.75 to 21.75 V. Shut down output; re-power on to recover.

    Environment and Cooling

    Ambient operating temperature -30 to 70 °C; apply the temperature and input-voltage derating curves
    Cooling Free-air convection; no fan
    Working humidity 20 ~ 90% RH non-condensing
    Storage temperature / humidity -40 ~ +85°C, 10 ~ 95% RH non-condensing
    Temperature coefficient ±0.03%/°C (0 ~ 50°C)
    Operating altitude Up to 5,000 m as stated for this series; the applicable overvoltage category and temperature derating impose additional limits.
    Overvoltage category Category III up to 2,000 m under the standards specified in this series datasheet. This is an insulation category, separate from the output-overvoltage protection threshold.
    Higher-altitude temperature derating For operation above 2,000 m, reduce the permitted ambient temperature by 5 °C per additional 1,000 m. Verify the applicable insulation/approval limits for the installation.

    Full rated output is not available at every point within the temperature and input ranges. Use the ambient-temperature and static input-voltage curves on PDF page 11 for this model and installation orientation.

    Dimensions and Installation

    Overall dimensions (L × W × H) 99 × 97 × 30 mm
    Case number 240A
    Drawing tolerance ±1 mm
    Mounting-hole callouts 2-M3 L=3.0; 2-M3 L=5
    Terminal 1 AC/L
    Terminal 2 AC/N
    Terminal 3 FG (protective earth)
    Terminal 4 DC OUTPUT -V
    Terminal 5 DC OUTPUT +V

    Use the mechanical drawing on PDF page 12 to locate the holes and confirm the permitted screw penetration for the selected mounting face. The M3/M4 callouts are mounting dimensions, not accessory ordering codes. Match wiring, protective-earth connection and output polarity to the terminal markings. Keep ventilation openings clear for convection cooling.

    This enclosed supply is a component for installation inside final equipment. Complete installation and electrical work using the manufacturer’s installation instructions and the applicable equipment requirements.

    Reference Weight

    Catalog reference per unit 230 g

    This value is the per-unit reference in the manufacturer’s PACKING row. It is not a measured net weight or a quotation for the complete shipping package.

    Application and Datasheet Notes

    EMC results are for a component installed on the manufacturer’s specified test plate. The finished equipment must be checked again for EMC compliance. Safety approvals and regional exceptions depend on the exact model and datasheet revision; refer to the linked specification and applicable certificates when selecting the unit.

    Additional Manufacturer Data

    Vibration test 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
    MTBF reference 3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 667.2Khrs min. MIL-HDBK-217F (25°C)
    Dielectric withstand I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
    Power indication LED power-on indicator
    Manufacturer datasheet warranty 3 years; subject to the manufacturer’s applicable warranty terms

    MTBF is a reliability prediction under the stated method and conditions, not a service-life or warranty-duration guarantee.

    Source: MEAN WELL LRS-75 datasheet, revision 2025-04-07, in the linked LRS catalog. Use the exact model specification, notes and drawings together when selecting and installing this supply.

    Recently viewed products

      Footer image

      © 2026 MEAN WELL, ,

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • AliPay
      • Amazon
      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • USDC
      • Visa