MEAN WELL OWA-200E series: moistureproof AC/DC adapter - OWA-200E-42

Description

MEAN WELL OWA-200E-42 is a moistureproof AC/DC adapter with 42 VDC, 4.75 A and 199 W rated output. Match the connected equipment to its fixed output voltage and rated current. This E version uses a CEE 7/7 AC plug and 180–264 VAC input. The IP67 rating is for the power body; connector protection must suit the installation.

Download MEAN WELL OWA-200E Datasheet (PDF)Download MEAN WELL Installation Manual (PDF)

Catalog location: PDF pages 37–41; specification table on page 38, curves on page 39, and connection drawing on page 40.

Model and output

Parameter Specification
Model and code OWA-200E-42 — OWA-200E; E identifies the European AC plug version; 42 identifies the nominal DC output voltage.
Output mode Single-output constant-voltage external AC/DC adapter.
Rated output voltage 42 VDC
Rated output current 4.75 A
Rated output power 199 W (catalog rating)
Maximum ripple and noise 250 mVp-p; measured at 20 MHz bandwidth with a 12-inch twisted pair and parallel 0.1 μF / 47 μF capacitors.
Voltage tolerance ±3%; includes initial setup tolerance, line regulation and load regulation.
Line and load regulation Line: ±0.5%; load: ±3%.

Input and electrical performance

Parameter Specification
Input voltage 180–264 VAC or 254–370 VDC. For DC operation, verify the manufacturer’s connection instructions and appropriate input connection for the delivered model.
Input frequency 47–63 Hz
Typical efficiency 94% at 230 VAC.
Typical power factor Built-in active PFC; >0.96 at 230 VAC at full load.
Typical AC input current 1.1 A at 230 VAC
Setup and rise time Setup 500 ms / rise 80 ms at 230 VAC. Setup time is measured at cold first start; turning the power supply ON/OFF may increase setup time.
Typical hold-up time 10 ms at full load, 230 VAC.
Typical inrush current Cold start: 65 A at 230 VAC; 550 μs width at 50% peak current.
Leakage current <0.25 mA at 240 VAC.
No-load consumption <0.15 W

Protection and operating conditions

Parameter Specification
Overcurrent protection 105–150%; hiccup mode, automatically recovers after the fault is removed.
Short-circuit protection Hiccup mode, automatically recovers after the fault is removed.
Overvoltage protection 46–57 V; output shuts down. Remove the fault and re-power to recover.
Overtemperature protection Output shuts down. Remove the overtemperature condition and re-power to recover.
Ambient temperature −40 to +70°C, subject to derating.
Cooling and load derating Fanless free-air convection with the recommended horizontal mounting. At 230 VAC: 100% load through +45°C, decreasing to 50% at +70°C. Apply thermal and input/load limits together; the upper ambient limit is not a full-load rating.
Input/load curve At 60 Hz: 100% load over 180–264 VAC.
Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH.
Temperature coefficient ±0.03%/°C over 0–50°C.
Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes each along X, Y and Z axes.

Safety and compliance

Parameter Specification
Catalog safety and construction Class II power unit, no FG connection; fully silicone-potted plastic enclosure. IP67 applies to the power body, not an unrestricted waterproof rating for plugs or the complete installation. DEKRA EN61558-1 and EN61558-2-16; DEKRA EN60335-1; EAC TP TC 004.
Energy-efficiency declarations Energy efficiency Level VI; EU ErP requirements are stated in the catalog. CoC Version 5 is also stated for this model.
EMC emissions EN55032 (CISPR32) Class B; EN55035; EN55014-1; EN61000-3-2/3; EAC TP TC 020 (as listed in the catalog).
Insulation Input-to-output withstand voltage: 4.2 kVAC. Input-to-output isolation resistance: 100 MΩ at 500 VDC / 25°C / 70% RH.
EMC immunity EN61000-4-2/-3/-4/-5/-6/-8/-11; EN55014-2; EN55024; light-industrial level with L–N surge 2 kV; EAC TP TC 020.

Connections and installation

Parameter Specification
Dimensions and mounting 195 × 68 × 39.5 mm (L × W × H); case PWM-200E, drawing tolerance ±1 mm; two Ø4.5 mm mounting holes. Follow the recommended horizontal mounting and dimensioned drawing. Retain the supplied cable/ferrite arrangement where fitted.
AC connection CEE 7/7; H05RN-F 1.0 mm² × 2 conductors, 1500 ±20 mm.
DC connection Standard XLR4P, NEUTRIK NC4MX or equivalent: pins 1 and 2 positive; pins 3 and 4 negative; connector rating 15 A maximum. SJOW 14 AWG × 2 conductors, 300 V / 105°C cable, 1000 ±20 mm. Use the numbered connector drawing to identify pins.
Optional connectors C6P MOLEX 39-01-2060 (4.2 mm) or equivalent, 15 A maximum: pins 1/2/3 positive, pins 4/5/6 negative; FG not connected to the output connector; M19 LLT-M19-20002F307 or equivalent, 15 A maximum: pin 1 positive, pin 2 negative; MIC4 NEUTRIK XLR NC4FX or equivalent, 15 A maximum: pins 1/2 positive, pins 3/4 negative; R7B KYCON KPPX-4P or equivalent, 15 A maximum: pins 1/4 positive, pins 2/3 negative. These are optional connector configurations, not the standard connector or included separate accessories. Confirm the factory configuration with MEAN WELL before ordering; observe both the supply rating and connector limit.
Catalog packing reference 1.32 kg per unit (1320 g); this is the catalog PACKING reference, not a measured net weight or a shipping-parcel weight.
MTBF 2677.8 / 267.6 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively.

Disconnect AC power before connecting the DC plug, installing, cleaning or servicing, and prevent accidental reconnection. Check voltage, polarity, connector size and current rating before use; never force an incompatible plug. Keep connections secure and protect cables from damage. Provide ventilation and leave 10–15 cm clearance when an adjacent device is a heat source; do not stack objects on the unit. Follow the catalog’s horizontal mounting and load curves; nonstandard mounting or high ambient temperature may require additional derating. Keep plugs and connections appropriately protected; do not immerse the unit in water. Do not open the enclosure. Damaged external cables must be replaced by the manufacturer, a service agent or similarly qualified personnel. Verify insulation, interconnections and EMC in the final equipment.

For battery-charging applications, the catalog recommends operation with a BMS controller. Confirm the battery and charging-control requirements for the complete system before use.

Specification notes

Unless otherwise specified, catalog parameters are measured at 230 VAC input, rated load and 25°C ambient. Typical efficiency, power factor and time values depend on operating conditions; protection thresholds do not authorize continuous overload. The manufacturer catalog states a 5-year warranty; applicable manufacturer terms govern.

MEAN WELL OWA-200E series: moistureproof AC/DC adapter - OWA-200E-42

Product form

MEAN WELL OWA-200E-42 is a moistureproof AC/DC adapter with 42 VDC, 4.75 A and 199 W rated output. Match the... Read more

$136.52 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL OWA-200E-42 is a moistureproof AC/DC adapter with 42 VDC, 4.75 A and 199 W rated output. Match the connected equipment to its fixed output voltage and rated current. This E version uses a CEE 7/7 AC plug and 180–264 VAC input. The IP67 rating is for the power body; connector protection must suit the installation.

    Download MEAN WELL OWA-200E Datasheet (PDF)Download MEAN WELL Installation Manual (PDF)

    Catalog location: PDF pages 37–41; specification table on page 38, curves on page 39, and connection drawing on page 40.

    Model and output

    Parameter Specification
    Model and code OWA-200E-42 — OWA-200E; E identifies the European AC plug version; 42 identifies the nominal DC output voltage.
    Output mode Single-output constant-voltage external AC/DC adapter.
    Rated output voltage 42 VDC
    Rated output current 4.75 A
    Rated output power 199 W (catalog rating)
    Maximum ripple and noise 250 mVp-p; measured at 20 MHz bandwidth with a 12-inch twisted pair and parallel 0.1 μF / 47 μF capacitors.
    Voltage tolerance ±3%; includes initial setup tolerance, line regulation and load regulation.
    Line and load regulation Line: ±0.5%; load: ±3%.

    Input and electrical performance

    Parameter Specification
    Input voltage 180–264 VAC or 254–370 VDC. For DC operation, verify the manufacturer’s connection instructions and appropriate input connection for the delivered model.
    Input frequency 47–63 Hz
    Typical efficiency 94% at 230 VAC.
    Typical power factor Built-in active PFC; >0.96 at 230 VAC at full load.
    Typical AC input current 1.1 A at 230 VAC
    Setup and rise time Setup 500 ms / rise 80 ms at 230 VAC. Setup time is measured at cold first start; turning the power supply ON/OFF may increase setup time.
    Typical hold-up time 10 ms at full load, 230 VAC.
    Typical inrush current Cold start: 65 A at 230 VAC; 550 μs width at 50% peak current.
    Leakage current <0.25 mA at 240 VAC.
    No-load consumption <0.15 W

    Protection and operating conditions

    Parameter Specification
    Overcurrent protection 105–150%; hiccup mode, automatically recovers after the fault is removed.
    Short-circuit protection Hiccup mode, automatically recovers after the fault is removed.
    Overvoltage protection 46–57 V; output shuts down. Remove the fault and re-power to recover.
    Overtemperature protection Output shuts down. Remove the overtemperature condition and re-power to recover.
    Ambient temperature −40 to +70°C, subject to derating.
    Cooling and load derating Fanless free-air convection with the recommended horizontal mounting. At 230 VAC: 100% load through +45°C, decreasing to 50% at +70°C. Apply thermal and input/load limits together; the upper ambient limit is not a full-load rating.
    Input/load curve At 60 Hz: 100% load over 180–264 VAC.
    Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH.
    Temperature coefficient ±0.03%/°C over 0–50°C.
    Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes each along X, Y and Z axes.

    Safety and compliance

    Parameter Specification
    Catalog safety and construction Class II power unit, no FG connection; fully silicone-potted plastic enclosure. IP67 applies to the power body, not an unrestricted waterproof rating for plugs or the complete installation. DEKRA EN61558-1 and EN61558-2-16; DEKRA EN60335-1; EAC TP TC 004.
    Energy-efficiency declarations Energy efficiency Level VI; EU ErP requirements are stated in the catalog. CoC Version 5 is also stated for this model.
    EMC emissions EN55032 (CISPR32) Class B; EN55035; EN55014-1; EN61000-3-2/3; EAC TP TC 020 (as listed in the catalog).
    Insulation Input-to-output withstand voltage: 4.2 kVAC. Input-to-output isolation resistance: 100 MΩ at 500 VDC / 25°C / 70% RH.
    EMC immunity EN61000-4-2/-3/-4/-5/-6/-8/-11; EN55014-2; EN55024; light-industrial level with L–N surge 2 kV; EAC TP TC 020.

    Connections and installation

    Parameter Specification
    Dimensions and mounting 195 × 68 × 39.5 mm (L × W × H); case PWM-200E, drawing tolerance ±1 mm; two Ø4.5 mm mounting holes. Follow the recommended horizontal mounting and dimensioned drawing. Retain the supplied cable/ferrite arrangement where fitted.
    AC connection CEE 7/7; H05RN-F 1.0 mm² × 2 conductors, 1500 ±20 mm.
    DC connection Standard XLR4P, NEUTRIK NC4MX or equivalent: pins 1 and 2 positive; pins 3 and 4 negative; connector rating 15 A maximum. SJOW 14 AWG × 2 conductors, 300 V / 105°C cable, 1000 ±20 mm. Use the numbered connector drawing to identify pins.
    Optional connectors C6P MOLEX 39-01-2060 (4.2 mm) or equivalent, 15 A maximum: pins 1/2/3 positive, pins 4/5/6 negative; FG not connected to the output connector; M19 LLT-M19-20002F307 or equivalent, 15 A maximum: pin 1 positive, pin 2 negative; MIC4 NEUTRIK XLR NC4FX or equivalent, 15 A maximum: pins 1/2 positive, pins 3/4 negative; R7B KYCON KPPX-4P or equivalent, 15 A maximum: pins 1/4 positive, pins 2/3 negative. These are optional connector configurations, not the standard connector or included separate accessories. Confirm the factory configuration with MEAN WELL before ordering; observe both the supply rating and connector limit.
    Catalog packing reference 1.32 kg per unit (1320 g); this is the catalog PACKING reference, not a measured net weight or a shipping-parcel weight.
    MTBF 2677.8 / 267.6 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively.

    Disconnect AC power before connecting the DC plug, installing, cleaning or servicing, and prevent accidental reconnection. Check voltage, polarity, connector size and current rating before use; never force an incompatible plug. Keep connections secure and protect cables from damage. Provide ventilation and leave 10–15 cm clearance when an adjacent device is a heat source; do not stack objects on the unit. Follow the catalog’s horizontal mounting and load curves; nonstandard mounting or high ambient temperature may require additional derating. Keep plugs and connections appropriately protected; do not immerse the unit in water. Do not open the enclosure. Damaged external cables must be replaced by the manufacturer, a service agent or similarly qualified personnel. Verify insulation, interconnections and EMC in the final equipment.

    For battery-charging applications, the catalog recommends operation with a BMS controller. Confirm the battery and charging-control requirements for the complete system before use.

    Specification notes

    Unless otherwise specified, catalog parameters are measured at 230 VAC input, rated load and 25°C ambient. Typical efficiency, power factor and time values depend on operating conditions; protection thresholds do not authorize continuous overload. The manufacturer catalog states a 5-year warranty; applicable manufacturer terms govern.