MEAN WELL PID-250D is a dual-output open-frame AC/DC power supply with 48 V on CH1 and 5 V on CH2. The complete unit is rated 250.6 W, with independently isolated output and return connections for CH1 and CH2. Active PFC, CH1 remote control and model-specific short-duration peak output support equipment integration; apply the cooling and input limits below.
Product Datasheet
Download MEAN WELL PID-250 Datasheet (PDF)
The PID-250 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation.
Model and Output Configuration
| Complete model |
PID-250D. |
| Output arrangement |
CH1: 48 V / 4.7 A; CH2: 5 V / 5 A at the catalogue-rated operating point. |
| Combined rated power |
250.6 W for the complete unit, not for each output. |
| Output returns |
CH1 uses COM1 and CH2 uses COM2; the catalogue identifies isolated outputs and grounds. |
| Factory test |
100% full-load burn-in test. |
Use both channel limits and the combined-power limit together. The channel current-range maxima are not additional independent power ratings.
CH1 Output Specifications
| Nominal voltage |
48 VDC. |
| Rated current |
4.7 A. |
| Current range |
0–4.7 A, subject to combined-power and cooling limits. |
| Peak loading |
8.4 A for CH1 for no more than 10 seconds, with the low-input restriction below. |
| Ripple and noise, maximum |
200 mVp-p. |
| Voltage adjustment |
43.2–52.8 V using SVR1. |
| Voltage tolerance |
±2.0%. |
| Line regulation |
±0.5%. |
| Load regulation |
±1.0%. |
CH2 Output Specifications
| Nominal voltage |
5 VDC. |
| Rated current |
5 A. |
| Current range |
0–5 A, subject to combined-power and cooling limits. |
| Peak loading |
5 A; no separate higher CH2 peak rating is specified. |
| Ripple and noise, maximum |
50 mVp-p. |
| Voltage adjustment |
4.75–5.25 V using SVR2. |
| Voltage tolerance |
±2.0%. |
| Line regulation |
±0.5%. |
| Load regulation |
±2.0%. |
Combined Loading and Measurement Conditions
Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.
The listed CH1 peak current is a short-duration limit of no more than 10 seconds, not a continuous operating current. It remains subject to the channel protection behaviour and the input-voltage restriction.
Below 110 VAC input, CH1 peak current must also not exceed 150% of its rated current. Apply the lower of that limit and the tabulated peak value; for this model the resulting limit is 7.05 A, calculated from those two limits.
Input and Timing
| Input range |
90–264 VAC or 127–370 VDC; 47–63 Hz AC. |
| Active PFC |
At full load, PF ≥0.92 at 230 VAC and ≥0.97 at 115 VAC. |
| Typical AC current |
3 A at 115 VAC; 1.5 A at 230 VAC. |
| Typical cold-start inrush |
58 A at 230 VAC. |
| Leakage current |
Less than 3.5 mA at 240 VAC. |
| Set-up / rise time |
2500 ms / 60 ms at 115 VAC; 1200 ms / 60 ms at 230 VAC. |
| Typical hold-up time |
30 ms at full load. |
| Switching frequencies |
PFC 100 kHz; PWM 100 kHz. |
At 60 Hz, allowable load is 80% at 90 VAC, rising to 100% at 110 VAC and remaining at 100% through 264 VAC. Apply the low-input peak-current condition separately.
Protection and Remote Control
| CH1 overload |
105–170% of rated output power: operation within 10 seconds followed by shutdown; re-power on to recover. Above 180% of rated power or during a short circuit, constant-current limiting operates within 10 seconds, then shutdown; re-power on to recover. |
| CH2 overload |
101–150% of rated output power; hiccup mode with automatic recovery after fault removal. |
| CH1 overvoltage |
54–64.8 V; output shuts down, re-power on to recover. |
| CH2 overvoltage |
5.5–6.75 V; Zener-diode clamp and hiccup protection, with automatic recovery after fault removal. |
| Overtemperature |
CH1 shuts down and automatically recovers after temperature falls. |
| CN52 remote control |
Pins 1 and 2 open: CH1 and CH2 ON. Pins 1 and 2 shorted: CH1 OFF, CH2 ON. |
| Channel dependency |
A CH2 malfunction also shuts down CH1. |
Remote control acts on CH1; the open/short input is not a command to turn both outputs off. Keep the two output return arrangements distinct when planning the load wiring.
Environment and Derating
| Working temperature |
−20 to 70°C, subject to the applicable derating curve. |
| Operating humidity |
20–90% RH, non-condensing. |
| Storage |
−20 to +85°C; 10–95% RH. |
| Temperature coefficient |
±0.05%/°C over 0–50°C. |
| Vibration |
10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. |
For horizontal installation, allowable load rises from 80% at −20°C to 100% at −10°C. With natural convection, 100% is available through 40°C, decreasing to 50% at 60°C; the no-fan curve ends at 60°C.
With the illustrated 18 CFM airflow, 100% is available through 60°C, decreasing to 60% at 70°C. The 70°C endpoint is a fan-cooled condition, not a natural-convection rating.
Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m with fanless cooling, or 5°C per additional 1000 m with fan cooling. Apply all relevant load and installation limits together.
Mechanical Installation
| Overall size, L × W × H |
222 × 95 × 40 mm. |
| Mounting |
Five Ø3.5 mm holes; corner-hole centres are 212 × 85 mm with 5 mm edge offsets. The drawing also marks a 130 mm bottom-hole location from the left outline. Use the full drawing to locate all five holes. |
| Tolerance and underside clearance |
Drawing tolerance ±1 mm; maximum underside projection 3 mm. |
| Fan arrangement |
At least 18 CFM from the short-side direction, shown 15 cm away with a 47.5 mm lateral alignment reference. |
| Grounding |
CN1 pin 1 is safety ground. For improved EMC, connect M1, M2, M3 and chassis ground electrically. |
| Heat-sink isolation |
Do not short HS1, HS2 and HS3 together. |
| Adjustments and fuse |
SVR1 adjusts CH1; SVR2 adjusts CH2. Input fuse marking: T6.3A/250V. |
Use the complete drawing on PDF page 11 for mounting and airflow. The illustrated external fan has no order code or supplied-parts quantity specified in these pages.
Connections and Mating Parts
| AC input CN1 |
JST B5P-VH or equivalent: pin 1 FG, pins 2 and 4 no pin, pin 3 AC/N, pin 5 AC/L. |
| Dual output CN51 |
JST B10P-VH or equivalent: pins 1–3 COM1, pins 4–6 V1 (CH1), pins 7–8 COM2, pins 9–10 V2 (CH2). |
| CN1 / CN51 mating parts |
JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. |
| Remote connector CN52 |
JST B2B-XH or equivalent, pins 1 and 2 for open/short control. Mating housing: JST XHP family; terminal: JST SXH-001T-P0.6 or equivalents. |
Select the complete VHR or XHP housing reference to match the connector circuit count and wire assembly. These references identify mating parts; no separate cover, bracket or cable-kit order code, or loose-parts inclusion, is specified.
Safety and Electromagnetic Compatibility
| Safety approvals |
UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004; the cover also identifies IEC62368-1 CB certification. |
| Withstand voltage |
Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. |
| Insulation resistance |
Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. |
| Emissions |
BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. |
| Immunity |
BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035 and BS EN/EN61000-6-2, heavy-industry level; EAC TP TC020. |
The catalogue EMC test arrangement uses a 360 × 360 mm metal plate, 1 mm thick. Confirm the finished equipment meets the applicable EMC and safety requirements with its actual enclosure, wiring and mounting.
Weight and Reliability
| Single-unit catalogue reference weight |
740 g, from the explicit per-unit PACKING value; a catalogue reference, not measured net or shipping-parcel weight. |
| Packing reference |
0.74 kg per unit; 18 pieces / 14.3 kg / 0.98 CUFT. |
| MTBF, minimum estimates |
2091.7 thousand hours, Telcordia SR-332 (Bellcore); 150.5 thousand hours, MIL-HDBK-217F at 25°C. |
| Manufacturer warranty |
3 years, subject to applicable terms. |
| Catalogue revision |
PID-250-SPEC, 2024-10-30; combined PDF pages 10–11. |