MEAN WELL SD-50C-24 is an enclosed, isolated single-output DC/DC converter delivering 24 V at up to 2.1 A, with a rated output of 50.4 W. The C-input version accepts 36–72 VDC. Its fanless metal enclosure uses free-air convection, with model-specific temperature derating and screw-terminal connections.

Product Datasheet

Download MEAN WELL SD-50 Datasheet (PDF)

The SD-50 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation.

Model and DC Output

Full model SD-50C-24
Series SD-50
Input version C: 36–72 VDC
Output code 24: 24 VDC
DC output voltage 24 V
Rated output current 2.1 A
Rated output power 50.4 W
Output current range 0–2.1 A
Output voltage adjustment 23–30 V
Maximum ripple and noise 150 mVp-p
Voltage tolerance ±1.0%
Line regulation ±0.2%
Load regulation ±0.2%

Input and Conversion Characteristics

Permitted input voltage 36–72 VDC
Typical efficiency 83%
DC input current 1.5 A at 48 VDC
Cooling Free-air convection; fanless
Input filtering Built-in EMI filter
Catalogue input-range feature 2:1 wide input range
Set-up / rise time at full load 2.5 s / 50 ms at 48 VDC
Factory screening 100% full-load burn-in test

Unless otherwise specified, the catalogue parameters use 48 VDC input, rated load and 25°C ambient. Select the input version before wiring; the input range is specific to the letter in the complete model number.

Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.

Protection

Short-circuit protection Included
Overload threshold 105–150% of rated output power
Overload response Hiccup mode; automatic recovery after the fault is removed
Overvoltage threshold 31.5–37.5 V at 10% load
Overvoltage response Hiccup mode; automatic recovery after the fault is removed

Operate within both the output current and output power ratings; the overload threshold is a protection characteristic, not a continuous or timed peak-output rating.

Environment and Derating

Working ambient temperature −10 to +60°C, subject to derating
Working humidity 20–90% RH, non-condensing
Storage temperature / humidity −20 to +85°C / 10–95% RH
Temperature coefficient ±0.03%/°C over 0–50°C
Vibration 10–500 Hz; 2 G; 10 min/cycle; 60 min along each X, Y and Z axis

The low-temperature curve rises from 80% load at −10°C to 100% at 0°C. Full load is shown through 50°C vertical / 45°C horizontal, then derating to 80% at 60°C vertical / 55°C horizontal.

Observe the corresponding horizontal/vertical curve when positioning the enclosure. The operating-temperature range does not mean full output is available at every temperature.

For fanless operation above 2000 m altitude, the catalogue note reduces the allowable ambient temperature by 3.5°C per additional 1000 m. This derating note does not independently specify a maximum installation altitude.

The SD-50C-24 static-characteristics plot illustrates the 24 V output over the normal 36–72 VDC input range. Curves outside that interval do not extend the specified operating input range.

Mechanical Details and Terminal Connections

Dimensions, L × W × H 159 × 97 × 38 mm
Mechanical drawing reference Case No. 901; dimensions in mm, general tolerance ±1 mm
Unit mass 430 g; catalogue PACKING reference per unit
Nominal switching frequency in block diagram 83 kHz
Terminal 1 DC input V+
Terminal 2 DC input V−
Terminal 3 FG / chassis ground
Terminal 4 DC output −V
Terminal 5 DC output +V

The drawing shows two bottom M3 and three side M3 positions, with 78 mm between the bottom mounting positions and 117 mm between the outer side positions. Use the matching drawing for the remaining locations.

Wire the numbered terminals according to this model-specific assignment, including the FG/chassis terminal. Maintain free-air convection around the enclosure. Use the output-voltage adjuster only within the specified adjustment range.

The catalogue mechanical pages specify the enclosure and screw-terminal connections. No separately orderable model-specific cable, terminal housing or mounting accessory is identified on these series pages.

Safety, EMC and Reliability

Catalogue safety / design references EAC TP TC 004 approved; design reference to AS/NZS 62368.1 and LVD
Withstand voltage, input to output 1.5 kVAC
Withstand voltage, input to FG 2 kVAC
Withstand voltage, output to FG 0.5 kVAC
Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH; input–output, input–FG and output–FG
EMC emission references BS EN/EN 55032 (CISPR 32) Class B; EAC TP TC 020
EMC immunity references BS EN/EN 61000-4-2, -3, -4, -6 and -8; BS EN/EN 55035; EAC TP TC 020
EMC environment in catalogue Heavy industry
MTBF, Telcordia SR-332 3293.1 thousand hours minimum
MTBF, MIL-HDBK-217F 512.8 thousand hours minimum at 25°C
Catalogue warranty period 2 years; subject to manufacturer terms

Design references and the catalogue approval statements have different meanings. The converter is a component for installation in end equipment; these references do not certify the completed system.

The EMC test arrangement mounts the converter on a 360 × 360 × 1 mm metal plate. The manufacturer requires EMC compliance to be reconfirmed in the completed installation. MTBF figures are reliability calculations, not a service-life guarantee.

MEAN WELL SD-50 series: Enclosed DC/DC Converter - SD-50C-24

Product form

MEAN WELL SD-50C-24 is an enclosed, isolated single-output DC/DC converter delivering 24 V at up to 2.1 A, with a... Read more

$73.44 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL SD-50C-24 is an enclosed, isolated single-output DC/DC converter delivering 24 V at up to 2.1 A, with a rated output of 50.4 W. The C-input version accepts 36–72 VDC. Its fanless metal enclosure uses free-air convection, with model-specific temperature derating and screw-terminal connections.

    Product Datasheet

    Download MEAN WELL SD-50 Datasheet (PDF)

    The SD-50 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation.

    Model and DC Output

    Full model SD-50C-24
    Series SD-50
    Input version C: 36–72 VDC
    Output code 24: 24 VDC
    DC output voltage 24 V
    Rated output current 2.1 A
    Rated output power 50.4 W
    Output current range 0–2.1 A
    Output voltage adjustment 23–30 V
    Maximum ripple and noise 150 mVp-p
    Voltage tolerance ±1.0%
    Line regulation ±0.2%
    Load regulation ±0.2%

    Input and Conversion Characteristics

    Permitted input voltage 36–72 VDC
    Typical efficiency 83%
    DC input current 1.5 A at 48 VDC
    Cooling Free-air convection; fanless
    Input filtering Built-in EMI filter
    Catalogue input-range feature 2:1 wide input range
    Set-up / rise time at full load 2.5 s / 50 ms at 48 VDC
    Factory screening 100% full-load burn-in test

    Unless otherwise specified, the catalogue parameters use 48 VDC input, rated load and 25°C ambient. Select the input version before wiring; the input range is specific to the letter in the complete model number.

    Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation.

    Protection

    Short-circuit protection Included
    Overload threshold 105–150% of rated output power
    Overload response Hiccup mode; automatic recovery after the fault is removed
    Overvoltage threshold 31.5–37.5 V at 10% load
    Overvoltage response Hiccup mode; automatic recovery after the fault is removed

    Operate within both the output current and output power ratings; the overload threshold is a protection characteristic, not a continuous or timed peak-output rating.

    Environment and Derating

    Working ambient temperature −10 to +60°C, subject to derating
    Working humidity 20–90% RH, non-condensing
    Storage temperature / humidity −20 to +85°C / 10–95% RH
    Temperature coefficient ±0.03%/°C over 0–50°C
    Vibration 10–500 Hz; 2 G; 10 min/cycle; 60 min along each X, Y and Z axis

    The low-temperature curve rises from 80% load at −10°C to 100% at 0°C. Full load is shown through 50°C vertical / 45°C horizontal, then derating to 80% at 60°C vertical / 55°C horizontal.

    Observe the corresponding horizontal/vertical curve when positioning the enclosure. The operating-temperature range does not mean full output is available at every temperature.

    For fanless operation above 2000 m altitude, the catalogue note reduces the allowable ambient temperature by 3.5°C per additional 1000 m. This derating note does not independently specify a maximum installation altitude.

    The SD-50C-24 static-characteristics plot illustrates the 24 V output over the normal 36–72 VDC input range. Curves outside that interval do not extend the specified operating input range.

    Mechanical Details and Terminal Connections

    Dimensions, L × W × H 159 × 97 × 38 mm
    Mechanical drawing reference Case No. 901; dimensions in mm, general tolerance ±1 mm
    Unit mass 430 g; catalogue PACKING reference per unit
    Nominal switching frequency in block diagram 83 kHz
    Terminal 1 DC input V+
    Terminal 2 DC input V−
    Terminal 3 FG / chassis ground
    Terminal 4 DC output −V
    Terminal 5 DC output +V

    The drawing shows two bottom M3 and three side M3 positions, with 78 mm between the bottom mounting positions and 117 mm between the outer side positions. Use the matching drawing for the remaining locations.

    Wire the numbered terminals according to this model-specific assignment, including the FG/chassis terminal. Maintain free-air convection around the enclosure. Use the output-voltage adjuster only within the specified adjustment range.

    The catalogue mechanical pages specify the enclosure and screw-terminal connections. No separately orderable model-specific cable, terminal housing or mounting accessory is identified on these series pages.

    Safety, EMC and Reliability

    Catalogue safety / design references EAC TP TC 004 approved; design reference to AS/NZS 62368.1 and LVD
    Withstand voltage, input to output 1.5 kVAC
    Withstand voltage, input to FG 2 kVAC
    Withstand voltage, output to FG 0.5 kVAC
    Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH; input–output, input–FG and output–FG
    EMC emission references BS EN/EN 55032 (CISPR 32) Class B; EAC TP TC 020
    EMC immunity references BS EN/EN 61000-4-2, -3, -4, -6 and -8; BS EN/EN 55035; EAC TP TC 020
    EMC environment in catalogue Heavy industry
    MTBF, Telcordia SR-332 3293.1 thousand hours minimum
    MTBF, MIL-HDBK-217F 512.8 thousand hours minimum at 25°C
    Catalogue warranty period 2 years; subject to manufacturer terms

    Design references and the catalogue approval statements have different meanings. The converter is a component for installation in end equipment; these references do not certify the completed system.

    The EMC test arrangement mounts the converter on a 360 × 360 × 1 mm metal plate. The manufacturer requires EMC compliance to be reconfirmed in the completed installation. MTBF figures are reliability calculations, not a service-life guarantee.

    Recently viewed products

      Footer image

      © 2026 MEAN WELL, ,

      • US (USD $) US (USD $)
      • Ach Direct Debit
      • AliPay
      • Amazon
      • American Express
      • Apple Pay
      • Diners Club
      • Discover
      • Google Pay
      • Mastercard
      • PayPal
      • Shop Pay
      • USDC
      • Visa