MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-BSN

Description

MEAN WELL XLC-60-H-BSN

XLC-60-H-BSN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Independent type with strain-relief caps (S). 3-in-1 dimming.

Output specifications

Parameter Specification
Model and configuration XLC-60-H-BSN; Independent type with strain-relief caps (S). 3-in-1 dimming.
Output mode Multiple-stage constant-power H type with selectable constant-current operating points.
Rated output power 60 W (catalog rating)
Output current 0.9–1.7 A adjustable
Default current 1400 mA
Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit.
Open-circuit voltage 60 V; the output hiccups under no-load conditions.
Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery.
Current tolerance ±5% (main output specification).
Current setting NFC setting, selected by this model suffix.
Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch.
Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient.

Output-current configuration

Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating.

Parameter Specification
900 mA 9–54 V recommended operating window.
1050 mA 9–54 V recommended operating window.
1200 mA 9–50 V recommended operating window.
1300 mA 9–46 V recommended operating window.
1400 mA (default) 9–43 V recommended operating window.
1500 mA 9–40 V recommended operating window.
1600 mA 9–38 V recommended operating window.
1700 mA 9–36 V recommended operating window.

N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%.

NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset.

Control and dimming

Parameter Specification
Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical.
Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle.
Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers.

Input and protection

Parameter Specification
AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source.
Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC.
Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC.
AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC.
Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410.
16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation.
Leakage current <0.75 mA at 277 VAC.
Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time.
Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions.
Short circuit Hiccup mode; automatically recovers after the fault is removed.
Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed.

Thermal and environmental limits

Parameter Specification
Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them.
Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating.
Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together.
Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver.
Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH.
Temperature coefficient ±0.03%/°C over 0–50°C.
Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis.
Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration.
MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively.

Safety and compliance conditions

Parameter Specification
Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV.
Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references.
Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range.
RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region.
Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH.
EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3.
EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods.
Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL.
ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation.

Mechanical and installation details

Parameter Specification
Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm.
Unit weight 390 g, catalog individual-unit PACKING value.
Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances.
Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−.
Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing.
Strain relief S configuration includes strain-relief caps.

Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC.

Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-BSN

Product form

MEAN WELL XLC-60-H-BSN XLC-60-H-BSN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC,... Read more

$58.16 Incl. VAT

    • Guaranteed secure & safe checkout.

      shop pay

    Description

    MEAN WELL XLC-60-H-BSN

    XLC-60-H-BSN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Independent type with strain-relief caps (S). 3-in-1 dimming.

    Output specifications

    Parameter Specification
    Model and configuration XLC-60-H-BSN; Independent type with strain-relief caps (S). 3-in-1 dimming.
    Output mode Multiple-stage constant-power H type with selectable constant-current operating points.
    Rated output power 60 W (catalog rating)
    Output current 0.9–1.7 A adjustable
    Default current 1400 mA
    Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit.
    Open-circuit voltage 60 V; the output hiccups under no-load conditions.
    Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery.
    Current tolerance ±5% (main output specification).
    Current setting NFC setting, selected by this model suffix.
    Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch.
    Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient.

    Output-current configuration

    Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating.

    Parameter Specification
    900 mA 9–54 V recommended operating window.
    1050 mA 9–54 V recommended operating window.
    1200 mA 9–50 V recommended operating window.
    1300 mA 9–46 V recommended operating window.
    1400 mA (default) 9–43 V recommended operating window.
    1500 mA 9–40 V recommended operating window.
    1600 mA 9–38 V recommended operating window.
    1700 mA 9–36 V recommended operating window.

    N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%.

    NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset.

    Control and dimming

    Parameter Specification
    Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical.
    Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle.
    Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers.

    Input and protection

    Parameter Specification
    AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source.
    Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC.
    Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC.
    AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC.
    Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410.
    16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation.
    Leakage current <0.75 mA at 277 VAC.
    Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time.
    Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions.
    Short circuit Hiccup mode; automatically recovers after the fault is removed.
    Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed.

    Thermal and environmental limits

    Parameter Specification
    Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them.
    Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating.
    Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together.
    Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver.
    Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH.
    Temperature coefficient ±0.03%/°C over 0–50°C.
    Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis.
    Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration.
    MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively.

    Safety and compliance conditions

    Parameter Specification
    Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV.
    Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references.
    Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range.
    RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region.
    Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH.
    EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3.
    EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods.
    Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL.
    ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation.

    Mechanical and installation details

    Parameter Specification
    Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm.
    Unit weight 390 g, catalog individual-unit PACKING value.
    Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances.
    Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−.
    Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing.
    Strain relief S configuration includes strain-relief caps.

    Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC.

    Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.