DRA Series: Power Supply , DRDN Series: DIN Rail Redundancy Module

10 products

MEAN WELL DIN Rail Automation & Redundancy Solutions

DRA Series (Adjustable Power) & DRDN Series (Redundancy Modules) | UL508 Approved

  • Portfolio Overview
  • DRA Series (Power Supply)
  • DRDN Series (Redundancy)
  • Control & Alarm Features
  • Dimensions

Intelligent Power Delivery & Uninterruptible Security

This specialized DIN rail portfolio unites the versatile DRA Series adjustable power supplies with the robust DRDN Series redundancy modules. Designed for modern automation control cabinets, this combination ensures your critical systems receive precise voltage and remain online even in the event of a single-point power failure.

Core Series Advantages

  • DRA Series (40W / 60W): Features built-in output current adjustment capabilities alongside standard voltage controls. Perfectly suited for machine vision systems, LED applications, and flexible automation equipment.
  • DRDN Series (20A / 40A): High-reliability DIN rail redundancy modules that allow you to connect two power supplies in parallel. Supports 1+1 and N+1 redundancy architectures with ultra-low voltage drops to ensure seamless power handover.
  • Industrial Grade: Both series are optimized for easy TS-35 DIN rail mounting and are fully certified to UL508 (Industrial Control Equipment).

DRA-40 & DRA-60: Adjustable DIN Rail Power Supplies

The DRA series stands out with its ability to allow current adjustment, providing flexibility not typically found in standard DIN rail units.

Model Series DRA-40 DRA-60
Max Rated Power 40W 60W
DC Voltages Available 12V, 24V 12V, 24V
Input Voltage Range 90 ~ 264VAC / 127 ~ 370VDC 90 ~ 264VAC / 127 ~ 370VDC
Max Efficiency (Typ.) Up to 87% Up to 87%
Cooling Method Free Air Convection Free Air Convection
Overload Behavior: The DRA series utilizes a constant current limiting mode (95% ~ 108% of rated output) to protect against overloads, automatically recovering once the load normalizes.

DRDN20 & DRDN40: Uninterruptible Redundancy Modules

Protect your critical infrastructure. The DRDN series monitors two independent power inputs. If one supply fails, the DRDN module instantly routes power from the secondary unit, ensuring zero downtime.

Model Series DRDN20 DRDN40
Max Output Current 20A (Continuous) 40A (Continuous)
Peak Current Limit (5s) 30A 60A
Voltage Options 12V, 24V, 48V 12V, 24V, 48V
Max Voltage Drop 0.25V 0.3V
Efficiency (Typ.) Up to 98% Up to 98%
Energy Efficiency: The ultra-low voltage drop (0.25V ~ 0.3V) prevents excessive heat buildup in the cabinet and maximizes overall system power delivery compared to traditional diode-based redundancy solutions.

Smart Control & System Diagnostics

DRA Series: System Adaptability

  • Current Adjustment: Designed for applications requiring tailored output characteristics, allowing flexible tuning of the power delivery.
  • Low No-Load Consumption: Consumes less than 0.75W when on standby, satisfying modern green energy requirements.

DRDN Series: Dual Input Alarms

  • Relay Contact Alarm: Features built-in 30VDC/1A relay contacts that trigger an alarm if either of the two input voltages drops below a specific safe threshold.
  • LED Status Indicators: Green "OK" LEDs visually confirm the operational status of both inputs directly on the front panel.
  • Voltage Thresholds: On a 24V system, the alarm triggers if the input falls below 18V or spikes above 31V. On a 48V system, it triggers below 34.2V or above 63V.

Dimensions & Installation Configurations

Both series are specifically built to clip effortlessly onto standard TS-35/7.5 and TS-35/15 DIN rails.

Physical Dimensions (W * H * D)

  • DRA-40: 40 * 90 * 100 mm
  • DRA-60: 40 * 90 * 100 mm
  • DRDN20: 32 * 125.2 * 102 mm
  • DRDN40: 55 * 125.2 * 100 mm
Environmental Tolerance:
- DRA Series: Operates safely in environments from -30°C up to +70°C.
- DRDN Series: Boasts a broader operating temperature range, handling harsh industrial extremes from -40°C up to +80°C.
  • DRDN40-48

    MEAN WELL DRDN-40 Series: Rail-type redundant modules - DRDN40-48

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 48Vdc Input rated voltage range: 36 ~ 60Vdc Input rated current: every input 0 ~ 40A continuous Output rated current: 0 ~ 40A, continuous Size (mm):55X125.2X113.5 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRDN40-24

    MEAN WELL DRDN-40 Series: Rail-type redundant modules - DRDN40-24

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 24Vdc Input rated voltage range: 19 ~ 29Vdc Input rated current: every input 0 ~ 40A continuous Output rated current: 0 ~ 40A, continuous Size (mm):55X125.2X113.5 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRDN40-12

    MEAN WELL DRDN-40 Series: Rail-type redundant modules - DRDN40-12

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 12Vdc Input rated voltage range: 9 ~ 14Vdc Input rated current: every input 0 ~ 40A continuous Output rated current: 0 ~ 40A, continuous Size (mm):55X125.2X113.5 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRDN20-48

    MEAN WELL DRDN-20 Series: Rail-type redundant modules - DRDN20-48

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 48Vdc Input rated voltage range: 36 ~ 60Vdc Input rated current: each input 0 ~ 20A continuous Output rated current: 0 ~ 20A, continuous Size (mm):32X125.2X102 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRDN20-24

    MEAN WELL DRDN-20 Series: Rail-type redundant modules - DRDN20-24

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 24Vdc Input rated voltage range: 19 ~ 29Vdc Input rated current: each input 0 ~ 20A continuous Output rated current: 0 ~ 20A, continuous Size (mm):32X125.2X102 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRDN20-12

    MEAN WELL DRDN-20 Series: Rail-type redundant modules - DRDN20-12

    Rail-type redundant module Number of inputs: 2 channels Input DC voltage rating: 12Vdc Input rated voltage range: 9 ~ 14Vdc Input rated current: each input 0 ~ 20A continuous Output rated current: 0 ~ 20A, continuous Size (mm):32X125.2X102 Click to download Airtac product catalog Product Features 1. Supports 1+1 and N +1 redundant systems. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. Output current 20A & 40A. 4. Suitable for 12V/24V/48 redundant system. 5. Two input and one output channel. 6, -40 ~ +80 ℃ ultra wide working temperature (>+60 ℃ reduction). 7. Built-in two-channel DC OK signal and alarm relay contact. 8. LED power start indicator, 3 years warranty.

  • DRA-60-48

    MEAN WELL DRA-60 Series: Power Supply - DRA-60-48

    Rated power: 60W Input voltage: 90 ~ 264VAC,127 ~ 370VDC [DC input can be realized by connecting AC/L(+),AC/N(-)] Output voltage: 24V Output current: 0 ~ 2.5A Size (mm):40X90X100 Click to download Airtac product catalog Product Features 1. International universal full range input: 90 ~ 264VAC. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. The output current can be adjusted by external 1 ~ 10Vdc or PWM signal or resistor. 4. Natural air cooling and heat dissipation. 5. Protection type: short circuit/overload/overvoltage. 6. Through LPS,DC output voltage is adjustable. 7. LED power start indicator. 8, 3 years warranty.

  • DRA-60-12

    MEAN WELL DRA-60 Series: Power Supply - DRA-60-12

    Rated power: 60W Input voltage: 90 ~ 264VAC,127 ~ 370VDC [DC input can be realized by connecting AC/L(+),AC/N(-)] Output voltage: 12V Output current: 0 ~ 5A Size (mm):40X90X100 Click to download Airtac product catalog Product Features 1. International universal full range input: 90 ~ 264VAC. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. The output current can be adjusted by external 1 ~ 10Vdc or PWM signal or resistor. 4. Natural air cooling and heat dissipation. 5. Protection type: short circuit/overload/overvoltage. 6. Through LPS,DC output voltage is adjustable. 7. LED power start indicator. 8, 3 years warranty.

  • DRA-40-24

    MEAN WELL DRA-40 Series: Power Supply - DRA-40-24

    Rated power: 40.8W Input voltage: 90 ~ 264VAC,127 ~ 370VDC [DC input can be realized by connecting AC/L(+),AC/N(-)] Output voltage: 24V Output current: 0 ~ 1.7A Size (mm):40X90X100 Click to download Airtac product catalog Product Features 1. International universal full range input: 90 ~ 264VAC. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. The output current can be adjusted by external 1 ~ 10Vdc or PWM signal or resistor. 4. Natural air cooling and heat dissipation. 5. Protection type: short circuit/overload/overvoltage. 6. Through LPS,DC output voltage is adjustable. 7. LED power start indicator. 8, 3 years warranty.

  • DRA-40-12

    MEAN WELL DRA-40 Series: Power Supply - DRA-40-12

    Rated power: 40.08W Input voltage: 90 ~ 264VAC,127 ~ 370VDC [DC input can be realized by connecting AC/L(+),AC/N(-)] Output voltage: 12V Output current: 0 ~ 3.34A Size (mm):40X90X100 Click to download Airtac product catalog Product Features 1. International universal full range input: 90 ~ 264VAC. 2. Mounting guide rail: TS-35/7.5 or TS-35/15. 3. The output current can be adjusted by external 1 ~ 10Vdc or PWM signal or resistor. 4. Natural air cooling and heat dissipation. 5. Protection type: short circuit/overload/overvoltage. 6. Through LPS,DC output voltage is adjustable. 7. LED power start indicator. 8, 3 years warranty.

Login

Forgot your password?

Don't have an account yet?
Create account