enp

24 products

  • ENC-360-48

    MEAN WELL ENC-360 series: Programmable Three-Stage Battery Charger - ENC-360-48

    The MEAN WELL ENC-360-48 is a fanless desktop battery charger with a default 57.6 V boost setting, 55.2 V float setting and 6 A constant-current charging output, rated at 345.6 W. Its 48 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-360 Datasheet (PDF) The ENC-360 section is on PDF pages 35, 36, 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-360-48 Nominal voltage class 48 V Default boost charge voltage 57.6 V Default float charge voltage 55.2 V Rated charging current 6 A Rated output power 345.6 W Programmable boost or float range 36–60 V Suggested battery capacity 25–65 Ah Typical battery leakage current Less than 1 mA Typical efficiency 94% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 57.6 V boost / 55.2 V float DIP 1 ON / DIP 2 OFF Gel preset: 56 V boost / 54.4 V float DIP 1 OFF / DIP 2 ON Flooded preset: 56.8 V boost / 53.6 V float DIP 1 ON / DIP 2 ON AGM preset: 58 V boost / 54 V float Default CC value for these curves 6 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 80 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 62.1–72.9 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.5 kg (1500 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 40. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 39 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 14336-1 approved; meets BS EN/EN 62368-1. The Japanese J62368-1 (2020) listing is limited to the 12 V and 24 V versions and is not claimed for this 48 V model. BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024, with BSMI CNS 13438 listed in the EMC table; the J55032(H29) listing is restricted to 12 V and 24 V versions. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1178.7 thousand hours minimum using Telcordia SR-332, or 138.7 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $241.99

  • ENC-360-24

    MEAN WELL ENC-360 series: Programmable Three-Stage Battery Charger - ENC-360-24

    The MEAN WELL ENC-360-24 is a fanless desktop battery charger with a default 28.8 V boost setting, 27.6 V float setting and 12 A constant-current charging output, rated at 345.6 W. Its 24 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-360 Datasheet (PDF) The ENC-360 section is on PDF pages 35, 36, 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-360-24 Nominal voltage class 24 V Default boost charge voltage 28.8 V Default float charge voltage 27.6 V Rated charging current 12 A Rated output power 345.6 W Programmable boost or float range 18–30 V Suggested battery capacity 45–125 Ah Typical battery leakage current Less than 1 mA Typical efficiency 93% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 28.8 V boost / 27.6 V float DIP 1 ON / DIP 2 OFF Gel preset: 28 V boost / 27.2 V float DIP 1 OFF / DIP 2 ON Flooded preset: 28.4 V boost / 26.8 V float DIP 1 ON / DIP 2 ON AGM preset: 29 V boost / 27 V float Default CC value for these curves 12 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 80 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 31–36.5 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.5 kg (1500 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 40. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 39 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 14336-1 approved; meets BS EN/EN 62368-1. The 12 V and 24 V versions also list J62368-1 (2020). BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024, with BSMI CNS 13438 listed in the EMC table; J55032(H29) applies to this 12 V or 24 V version. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1178.7 thousand hours minimum using Telcordia SR-332, or 138.7 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $241.99

  • ENC-360-12

    MEAN WELL ENC-360 series: Programmable Three-Stage Battery Charger - ENC-360-12

    The MEAN WELL ENC-360-12 is a fanless desktop battery charger with a default 14.4 V boost setting, 13.8 V float setting and 24 A constant-current charging output, rated at 345.6 W. Its 12 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-360 Datasheet (PDF) The ENC-360 section is on PDF pages 35, 36, 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-360-12 Nominal voltage class 12 V Default boost charge voltage 14.4 V Default float charge voltage 13.8 V Rated charging current 24 A Rated output power 345.6 W Programmable boost or float range 9–15 V Suggested battery capacity 85–250 Ah Typical battery leakage current Less than 1 mA Typical efficiency 91% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 14.4 V boost / 13.8 V float DIP 1 ON / DIP 2 OFF Gel preset: 14 V boost / 13.6 V float DIP 1 OFF / DIP 2 ON Flooded preset: 14.2 V boost / 13.4 V float DIP 1 ON / DIP 2 ON AGM preset: 14.5 V boost / 13.5 V float Default CC value for these curves 24 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 80 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 15.5–18.2 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.5 kg (1500 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 40. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 39 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 14336-1 approved; meets BS EN/EN 62368-1. The 12 V and 24 V versions also list J62368-1 (2020). BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024, with BSMI CNS 13438 listed in the EMC table; J55032(H29) applies to this 12 V or 24 V version. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1178.7 thousand hours minimum using Telcordia SR-332, or 138.7 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $241.99

  • ENC-240-48

    MEAN WELL ENC-240 series: Programmable Three-Stage Battery Charger - ENC-240-48

    The MEAN WELL ENC-240-48 is a fanless desktop battery charger with a default 57.6 V boost setting, 55.2 V float setting and 4 A constant-current charging output, rated at 230.4 W. Its 48 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-240 Datasheet (PDF) The ENC-240 section is on PDF pages 29, 30, 31, 32, 33, 34. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-240-48 Nominal voltage class 48 V Default boost charge voltage 57.6 V Default float charge voltage 55.2 V Rated charging current 4 A Rated output power 230.4 W Programmable boost or float range 36–60 V Suggested battery capacity 15–45 Ah Typical battery leakage current Less than 1 mA Typical efficiency 93% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 57.6 V boost / 55.2 V float DIP 1 ON / DIP 2 OFF Gel preset: 56 V boost / 54.4 V float DIP 1 OFF / DIP 2 ON Flooded preset: 56.8 V boost / 53.6 V float DIP 1 ON / DIP 2 ON AGM preset: 58 V boost / 54 V float Default CC value for these curves 4 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 75 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 62.1–72.9 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.23 kg (1230 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 34. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 33 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 15598-1 approved; meets BS EN/EN 62368-1. BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. BSMI CNS 15936 is also listed for both. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1423.3 thousand hours minimum using Telcordia SR-332, or 155.9 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $199.11

  • ENC-240-24

    MEAN WELL ENC-240 series: Programmable Three-Stage Battery Charger - ENC-240-24

    The MEAN WELL ENC-240-24 is a fanless desktop battery charger with a default 28.8 V boost setting, 27.6 V float setting and 8 A constant-current charging output, rated at 230.4 W. Its 24 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-240 Datasheet (PDF) The ENC-240 section is on PDF pages 29, 30, 31, 32, 33, 34. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-240-24 Nominal voltage class 24 V Default boost charge voltage 28.8 V Default float charge voltage 27.6 V Rated charging current 8 A Rated output power 230.4 W Programmable boost or float range 18–30 V Suggested battery capacity 30–85 Ah Typical battery leakage current Less than 1 mA Typical efficiency 92% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 28.8 V boost / 27.6 V float DIP 1 ON / DIP 2 OFF Gel preset: 28 V boost / 27.2 V float DIP 1 OFF / DIP 2 ON Flooded preset: 28.4 V boost / 26.8 V float DIP 1 ON / DIP 2 ON AGM preset: 29 V boost / 27 V float Default CC value for these curves 8 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 75 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 31–36.5 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.23 kg (1230 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 34. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 33 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 15598-1 approved; meets BS EN/EN 62368-1. BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. BSMI CNS 15936 is also listed for both. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1423.3 thousand hours minimum using Telcordia SR-332, or 155.9 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $199.11

  • ENC-240-12

    MEAN WELL ENC-240 series: Programmable Three-Stage Battery Charger - ENC-240-12

    The MEAN WELL ENC-240-12 is a fanless desktop battery charger with a default 14.4 V boost setting, 13.8 V float setting and 16 A constant-current charging output, rated at 230.4 W. Its 12 V model designation identifies the nominal voltage class, not the actual boost or float voltage. The three-stage charging profile supports DIP-selected presets and programming for the particular battery specification. Product Datasheet Download MEAN WELL ENC-240 Datasheet (PDF) The ENC-240 section is on PDF pages 29, 30, 31, 32, 33, 34. Refer to the complete mechanical drawings and notes when planning installation. Charging Output and Battery Selection Complete model ENC-240-12 Nominal voltage class 12 V Default boost charge voltage 14.4 V Default float charge voltage 13.8 V Rated charging current 16 A Rated output power 230.4 W Programmable boost or float range 9–15 V Suggested battery capacity 60–170 Ah Typical battery leakage current Less than 1 mA Typical efficiency 91% The voltage range applies to programming Vboost or Vfloat with the SBP-001 smart battery charging programmer; it is not a separate continuously adjustable front-panel output. The listed battery-capacity range is a recommendation, not a substitute for checking the battery manufacturer’s maximum charging current. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion batteries described as lithium iron and lithium manganese. Select a charging profile approved for the particular pack, chemistry and battery-management requirements. Modification of charger specifications may be needed; consult the battery supplier and MEAN WELL. A nominal voltage match alone does not establish compatibility. Three-Stage Charging and DIP Presets DIP 1 OFF / DIP 2 OFF Default programmable: 14.4 V boost / 13.8 V float DIP 1 ON / DIP 2 OFF Gel preset: 14 V boost / 13.6 V float DIP 1 OFF / DIP 2 ON Flooded preset: 14.2 V boost / 13.4 V float DIP 1 ON / DIP 2 ON AGM preset: 14.5 V boost / 13.5 V float Default CC value for these curves 16 A Status indicator Orange: charging in stage 1 or 2; green: float in stage 3 Stage 1 supplies constant current while battery voltage rises to Vboost. Stage 2 holds Vboost while current falls. The published curve changes to stage 3 at 10% of the CC setting, reducing voltage to Vfloat. Green identifies the float stage rather than an independently measured state of charge for every battery chemistry. To alter the default charging curve, use the MEAN WELL SBP-001 smart battery charging programmer with a personal computer. Select programming and interconnection accessories for this charger; the charger order number does not itself include the programmer or computer. The other three predefined profiles are selected with the two-position DIP switch. Input and Power Factor Input range 90–264 VAC or 127–370 VDC AC frequency 47–63 Hz Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC Active PFC, typical power factor PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load Typical cold-start inrush current 75 A at 230 VAC Leakage current Less than 3.5 mA at 240 VAC The mechanical drawing shows an AC inlet, power switch and frame-grounded metal enclosure. Use the inlet and protective-earth arrangement shown in the product drawing. Input-current and efficiency figures are typical, under the stated catalogue test conditions. Protection and Temperature Compensation Short circuit Output shutdown; re-power to recover. This mechanism is specified for a short circuit occurring after the charger has been turned on. Overvoltage range 15.5–18.2 V; output shuts down and latches off; re-power to recover Overtemperature Output shutdown; automatic recovery after temperature falls Reverse battery polarity Protection by an internal fuse Battery under- and overvoltage Listed protection functions; battery-specific threshold suitability must be confirmed Temperature compensation Built-in function using an NTC sensor The MCU-controlled dynamic overvoltage protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and 115% of Vfloat during float charging. These protection levels do not replace the selected battery charging limits. Connect the NTC circuit to CN31 RTH+ and RTH− using the matching sensor assembly. No numerical temperature-compensation slope or battery under-/overvoltage cutoff is specified in these pages. Cooling and Derating Cooling Fanless, free-air convection Working temperature −30 to +70°C, subject to derating Horizontal installation curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C AC input curve at 60 Hz 90% load at 90 VAC; 100% at 100 VAC and from 100 to 264 VAC Allow free airflow around the charger and apply temperature and low-input restrictions together. The AC graph does not establish a separate DC-input derating curve. For this fanless model above 2000 m, reduce permissible ambient temperature by 3.5°C per additional 1000 m. This adjustment is not an unrestricted maximum-altitude rating. Output Terminals and Programming Connector TB1 terminal assignment 1 and 2: +V; 3 and 4: −V TB1 wire cross-section 0.5–4.0 mm²; the catalogue also specifies 12–20 AWG TB1 stripping and tightening 9 mm stripped length; 4.0 lb-in torque (0.4–0.5 N·m) CN31 connector HRS DF11-6DP-2DS or equivalent CN31 mating housing HRS DF11-6DS or equivalent CN31 contacts HRS DF11-**SC or equivalent contact family CN31 pins 1 and 2 1: Prog- +3.3V; 2: Prog- GND CN31 pins 3 and 4 3: Prog- RX; 4: Prog- TX CN31 pins 5 and 6 5: RTH+; 6: RTH− Use the pin orientation in the mechanical drawing rather than relying on a connector photograph. DF11-**SC is a contact-family notation containing a wildcard; select the complete contact suffix appropriate to the wire and assembly. CN31 programming pins are not presented as a general-purpose remote ON/OFF interface. NTC Accessories and Mechanical Installation NTC sensor wire Accessory list quantity: 1; UL2468 24×2C marking; drawing shows 50 mm insulated length and 7 mm stripped ends NTC mating wire Accessory list quantity: 1; UL1007 28 AWG; drawing shows 50 mm insulated length and 6 mm stripped ends Body dimensions 192 × 178 × 45.5 mm (L × W × H) Case drawing Case No. 252; dimensional tolerance ±1 mm Mounting callout Two M3 positions, marked 2-M3 L=5; 78 mm centre spacing Catalogue unit weight 1.23 kg (1230 g), catalogue packing reference per unit; not a measured net or shipping weight The NTC accessory drawings are on PDF page 34. The mating-wire drawing carries the HRS DF11-6DP-2DS or equivalent caption; use it together with the explicit CN31 mating-housing and contact table on page 33 when ordering a complete assembly. No independent sensor assembly order code is specified on these pages. Confirm the actual accessory supply contents. The mounting centres are 47.5 mm from the indicated right-hand body edge, with the upper centre 50 mm from the top edge. The side view also marks a 4.3 mm projection beyond the 45.5 mm body dimension. Follow the complete drawing for inlet, output-terminal, LED, switch and cable clearances; do not obstruct convection cooling. Environment, Safety and Reliability Working humidity 20–95% RH, non-condensing Storage conditions −40 to +85°C; 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS 15598-1 approved; meets BS EN/EN 62368-1. BS EN/EN 55032 (CISPR32) and FCC Part 15 (CISPR22), Class B for both conducted and radiated emissions. BSMI CNS 15936 is also listed for both. Harmonic current: BS EN/EN 61000-3-2. Voltage flicker: BS EN/EN 61000-3-3. BS EN/EN 55024. The immunity table specifies ESD (61000-4-2) level 3, 8 kV air and level 2, 4 kV contact; radiated RF (4-3) level 2, 3 V/m; EFT/burst (4-4) level 2, 1 kV; surge (4-5) level 2, 1 kV line–line and level 3, 2 kV line–earth; conducted RF (4-6) level 2, 3 Vrms; and magnetic field (4-8) level 1, 1 A/m. For 61000-4-11, the table gives >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods. Calculated MTBF: 1423.3 thousand hours minimum using Telcordia SR-332, or 155.9 thousand hours minimum using MIL-HDBK-217F at 25°C. These estimates are not a service-life guarantee. The manufacturer’s catalogue lists a three-year warranty. Unless otherwise stated, measurements use 230 VAC, rated load and 25°C ambient. The charger is considered an independent unit, but EMC compliance of the final equipment must be reconfirmed. Confirm battery-specific settings before use.

    $199.11

  • ENC-180-48

    MEAN WELL ENC-180 series: Programmable Three-Stage Desktop Battery Charger - ENC-180-48

    The MEAN WELL ENC-180-48 is a fanless programmable desktop battery charger for the 48 V nominal battery class. Its default three-stage profile uses 57.6 V boost charging, 55.2 V float charging and 3 A constant current, with a rated output power of 172.8 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-180 Datasheet (PDF) The ENC-180 section is on PDF pages 23, 24, 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-180-48 Model code ENC-180 identifies the programmable desktop charger series; 48 identifies the nominal battery-voltage class. Default boost charge voltage 57.6 V Default float charge voltage 55.2 V Rated charging current 3 A Rated output power 172.8 W Programmable charge-voltage range 36–60 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 15–35 Ah Typical battery leakage current Less than 1 mA Typical efficiency 93% The 48 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 3 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 57.6 V; Vfloat 55.2 V; default CC 3 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 56 V; Vfloat 54.4 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 56.8 V; Vfloat 53.6 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 58 V; Vfloat 54 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 3 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 62.1–72.9 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 1.15 kg (1150 g), catalogue packing reference per unit; not a measured net or shipping weight. Mounting holes Two M3 positions marked L=5 mm; follow the complete drawing for their 47.5, 50 and 78 mm locating dimensions. PDF page 27 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1445.6 thousand hours, Telcordia SR-332; 155.9 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $175.95

  • ENC-180-24

    MEAN WELL ENC-180 series: Programmable Three-Stage Desktop Battery Charger - ENC-180-24

    The MEAN WELL ENC-180-24 is a fanless programmable desktop battery charger for the 24 V nominal battery class. Its default three-stage profile uses 28.8 V boost charging, 27.6 V float charging and 6 A constant current, with a rated output power of 172.8 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-180 Datasheet (PDF) The ENC-180 section is on PDF pages 23, 24, 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-180-24 Model code ENC-180 identifies the programmable desktop charger series; 24 identifies the nominal battery-voltage class. Default boost charge voltage 28.8 V Default float charge voltage 27.6 V Rated charging current 6 A Rated output power 172.8 W Programmable charge-voltage range 18–30 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 25–65 Ah Typical battery leakage current Less than 1 mA Typical efficiency 92% The 24 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 6 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 28.8 V; Vfloat 27.6 V; default CC 6 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 28 V; Vfloat 27.2 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 28.4 V; Vfloat 26.8 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 29 V; Vfloat 27 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 6 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 31–36.5 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 1.15 kg (1150 g), catalogue packing reference per unit; not a measured net or shipping weight. Mounting holes Two M3 positions marked L=5 mm; follow the complete drawing for their 47.5, 50 and 78 mm locating dimensions. PDF page 27 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1445.6 thousand hours, Telcordia SR-332; 155.9 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $175.95

  • ENC-180-12

    MEAN WELL ENC-180 series: Programmable Three-Stage Desktop Battery Charger - ENC-180-12

    The MEAN WELL ENC-180-12 is a fanless programmable desktop battery charger for the 12 V nominal battery class. Its default three-stage profile uses 14.4 V boost charging, 13.8 V float charging and 12 A constant current, with a rated output power of 172.8 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-180 Datasheet (PDF) The ENC-180 section is on PDF pages 23, 24, 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-180-12 Model code ENC-180 identifies the programmable desktop charger series; 12 identifies the nominal battery-voltage class. Default boost charge voltage 14.4 V Default float charge voltage 13.8 V Rated charging current 12 A Rated output power 172.8 W Programmable charge-voltage range 9–15 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 45–125 Ah Typical battery leakage current Less than 1 mA Typical efficiency 91% The 12 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 12 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 14.4 V; Vfloat 13.8 V; default CC 12 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 14 V; Vfloat 13.6 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 14.2 V; Vfloat 13.4 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 14.5 V; Vfloat 13.5 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 12 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 15.5–18.2 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 1.15 kg (1150 g), catalogue packing reference per unit; not a measured net or shipping weight. Mounting holes Two M3 positions marked L=5 mm; follow the complete drawing for their 47.5, 50 and 78 mm locating dimensions. PDF page 27 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1445.6 thousand hours, Telcordia SR-332; 155.9 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $175.95

  • ENC-120-48

    MEAN WELL ENC-120 series: Programmable Three-Stage Desktop Battery Charger - ENC-120-48

    The MEAN WELL ENC-120-48 is a fanless programmable desktop battery charger for the 48 V nominal battery class. Its default three-stage profile uses 57.6 V boost charging, 55.2 V float charging and 2 A constant current, with a rated output power of 115.2 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-120 Datasheet (PDF) The ENC-120 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-120-48 Model code ENC-120 identifies the programmable desktop charger series; 48 identifies the nominal battery-voltage class. Default boost charge voltage 57.6 V Default float charge voltage 55.2 V Rated charging current 2 A Rated output power 115.2 W Programmable charge-voltage range 36–60 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 10–20 Ah Typical battery leakage current Less than 1 mA Typical efficiency 90.5% The 48 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 2 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 57.6 V; Vfloat 55.2 V; default CC 2 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 56 V; Vfloat 54.4 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 56.8 V; Vfloat 53.6 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 58 V; Vfloat 54 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 2 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 62.1–72.9 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 0.98 kg (980 g), catalogue packing reference per unit; not a measured net or shipping weight. PDF page 21 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1726.4 thousand hours, Telcordia SR-332; 206.1 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $152.29

  • ENC-120-24

    MEAN WELL ENC-120 series: Programmable Three-Stage Desktop Battery Charger - ENC-120-24

    The MEAN WELL ENC-120-24 is a fanless programmable desktop battery charger for the 24 V nominal battery class. Its default three-stage profile uses 28.8 V boost charging, 27.6 V float charging and 4 A constant current, with a rated output power of 115.2 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-120 Datasheet (PDF) The ENC-120 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-120-24 Model code ENC-120 identifies the programmable desktop charger series; 24 identifies the nominal battery-voltage class. Default boost charge voltage 28.8 V Default float charge voltage 27.6 V Rated charging current 4 A Rated output power 115.2 W Programmable charge-voltage range 18–30 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 15–40 Ah Typical battery leakage current Less than 1 mA Typical efficiency 90% The 24 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 4 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 28.8 V; Vfloat 27.6 V; default CC 4 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 28 V; Vfloat 27.2 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 28.4 V; Vfloat 26.8 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 29 V; Vfloat 27 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 4 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 31–36.5 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 0.98 kg (980 g), catalogue packing reference per unit; not a measured net or shipping weight. PDF page 21 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1726.4 thousand hours, Telcordia SR-332; 206.1 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $152.29

  • ENC-120-12

    MEAN WELL ENC-120 series: Programmable Three-Stage Desktop Battery Charger - ENC-120-12

    The MEAN WELL ENC-120-12 is a fanless programmable desktop battery charger for the 12 V nominal battery class. Its default three-stage profile uses 14.4 V boost charging, 13.8 V float charging and 8 A constant current, with a rated output power of 115.2 W. Select the charging curve and temperature compensation to suit the battery. Product Datasheet Download MEAN WELL ENC-120 Datasheet (PDF) The ENC-120 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Charging Output Complete model ENC-120-12 Model code ENC-120 identifies the programmable desktop charger series; 12 identifies the nominal battery-voltage class. Default boost charge voltage 14.4 V Default float charge voltage 13.8 V Rated charging current 8 A Rated output power 115.2 W Programmable charge-voltage range 9–15 V for Vboost or Vfloat, using SBP-001. Suggested battery capacity 30–80 Ah Typical battery leakage current Less than 1 mA Typical efficiency 89% The 12 V model designation is a nominal battery class, not a fixed charging-output voltage. Select a battery pack whose charge limits match the actual boost and float settings, the 8 A default current and the required temperature compensation. The catalogue identifies flooded, gel and AGM lead-acid batteries, and lithium-ion types described as lithium iron and lithium manganese. Compatibility depends on the complete battery specification and its protection requirements; consult the battery manufacturer and MEAN WELL about settings and maximum permissible charging current. The suggested capacity range does not replace that check. Three-Stage Charging and Curve Selection DIP 1 OFF / DIP 2 OFF Default programmable curve: Vboost 14.4 V; Vfloat 13.8 V; default CC 8 A. DIP 1 ON / DIP 2 OFF Predefined gel curve: Vboost 14 V; Vfloat 13.6 V. DIP 1 OFF / DIP 2 ON Predefined flooded-battery curve: Vboost 14.2 V; Vfloat 13.4 V. DIP 1 ON / DIP 2 ON Predefined AGM curve: Vboost 14.5 V; Vfloat 13.5 V. Stage 1 charges at constant current while voltage rises. Stage 2 holds Vboost and allows charging current to fall. The default diagram marks the transition to stage 3 at 10% of the selected CC level; stage 3 then holds the lower Vfloat voltage. The status LED is orange during stages 1 and 2, and green during the float stage. Green indicates the charger's stage, not a universal state-of-charge measurement for every battery chemistry. The embedded curve table specifies 8 A as the default CC setting for this model. The two-position DIP switch selects the default programmable curve or one of the three predefined battery curves shown above. Changing the default charging-curve parameters requires the MEAN WELL SBP-001 smart battery charging programmer and a personal computer. These programming tools are not listed as supplied charger accessories. Select the charging profile for the battery before operation; the programmable voltage range is not a guarantee of suitability for every battery within it. AC/DC Input Input voltage 90–264 VAC or 127–370 VDC; apply low-input derating. Input frequency 47–63 Hz Typical power factor PF >0.98 at 115 VAC; PF >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC Input leakage current Less than 3.5 mA at 240 VAC Active power factor correction is built in. Use the grounded AC inlet and protective-earth connection shown in the mechanical and block diagrams, and keep access to the power switch and input connection. Unless otherwise stated, the published specifications are measured at 230 VAC, rated load and 25°C ambient. Protection and Battery Temperature Compensation Short circuit Output shuts down; re-power to recover. This specification applies to a short circuit occurring after the charger is turned on. Specified overvoltage range 15.5–18.2 V; output shuts down and latches off, requiring re-powering to recover. Dynamic overvoltage control MCU protection is approximately 115% of Vboost during constant-current and constant-voltage stages, and approximately 115% of Vfloat during the float stage. Battery reverse polarity Protection by an internal fuse. Overtemperature Output shuts down and recovers automatically after temperature falls. Battery undervoltage Battery undervoltage protection is included in the feature list. Temperature compensation Built-in NTC temperature compensation; connect the sensor through RTH+ and RTH− at CN31. Match battery polarity and the selected charge curve before connection. The programmed charge voltage and the stage-dependent protection function must be considered together; the overvoltage range is not an adjustable normal charging range. Temperature, Input Derating and Environment Working temperature −30 to +70°C, subject to derating. Horizontal thermal curve 100% load from −30 to +50°C; reduce linearly to 60% at +70°C. AC input curve at 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–95% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Cooling is by free-air convection without a fan. Apply the horizontal-installation curve and the low-input curve together, keeping ventilation openings unobstructed. The published AC curve does not define a separate DC-input curve. For this fanless charger, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment does not establish an unrestricted maximum operating altitude. Dimensions and Installation Body dimensions 192 × 178 × 45.5 mm (L × W × H); case 252. Drawing tolerance ±1 mm unless otherwise indicated in the mechanical drawing. Catalogue unit weight 0.98 kg (980 g), catalogue packing reference per unit; not a measured net or shipping weight. PDF page 21 shows the inlet, switch, output terminal block, indicator, DIP switch and six-pin programming/sensor connector. Follow the complete drawing for orientation and clearance. Output Wiring and CN31 Interface TB1 output terminals Pins 1 and 2: +V; pins 3 and 4: −V. TB1 conductor size 0.5–4.0 mm² (12–20 AWG). TB1 preparation and torque Recommended stripped length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). CN31 connector HRS DF11-6DP-2DS or equivalent. CN31 pin 1 Prog-+3.3V CN31 pin 2 Prog-GND CN31 pin 3 Prog-RX CN31 pin 4 Prog-TX CN31 pin 5 RTH+ CN31 pin 6 RTH− CN31 mating housing HRS DF11-6DS or equivalent. CN31 contact reference HRS DF11-**SC or equivalent; select the complete contact variant for the intended wire assembly. Use the connector-view numbering in the mechanical drawing. The programming supply and RX/TX pins serve the stated programming interface; do not use them as a general-purpose auxiliary power output. Programming Equipment and Listed Accessories Programming equipment SBP-001 smart battery charging programmer plus a personal computer; required for changing the programmable curve. NTC sensor wire Quantity 1 in the accessory list. Drawing: UL2468 24 × 2C, 50 mm insulated wire length and 7 mm exposed end. NTC mating wire Quantity 1 in the accessory list. Drawing: UL1007 28 AWG, 50 mm insulated wire length and 6 mm exposed end. Sensor-wire connector drawing reference HRS DF11-6DP-2DS or equivalent, as identified on the NTC mating-wire drawing. The two NTC wires are the accessories identified with quantities in the charger catalogue. The connector and contact references above specify the matching interface parts; additional loose contacts, mains leads, battery leads or programming equipment are not included in that accessory list. Confirm the ordered package contents and the finished cable assembly when procuring replacements. Safety, EMC and Reliability Safety approvals IEC 62368-1, UL 62368-1, EAC TP TC 004 and BSMI CNS15598-1 approved; meets BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ between input/output, input/FG and output/FG; tested at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions Class B: BS EN/EN 55032 (CISPR32), FCC Part 15 (CISPR22) and BSMI CNS15936. Harmonics and flicker BS EN/EN 61000-3-2 and BS EN/EN 61000-3-3. ESD immunity BS EN/EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. Radiated immunity BS EN/EN 61000-4-3: 3 V/m, level 2. EFT/burst immunity BS EN/EN 61000-4-4: 1 kV, level 2. Surge immunity BS EN/EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted immunity BS EN/EN 61000-4-6: 3 Vrms, level 2. Magnetic-field immunity BS EN/EN 61000-4-8: 1 A/m, level 1. Voltage dips and interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Calculated minimum MTBF 1726.4 thousand hours, Telcordia SR-332; 206.1 thousand hours, MIL-HDBK-217F at 25°C. The immunity framework is BS EN/EN 55024. Although the charger is evaluated as an independent unit, the complete installed equipment still requires confirmation of compliance with the EMC directives. The catalogue lists a three-year manufacturer warranty. Calculated MTBF is a reliability estimate, not a guaranteed service life.

    $152.29

  • ENP-360-48

    MEAN WELL ENP-360 series: Fanless Desktop AC/DC Power Supply - ENP-360-48

    MEAN WELL ENP-360-48 is a fanless ENP-360 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 55.2 V DC, 6.5 A rated current and 359 W rated output power. Peak output is limited to 8.2 A and 453 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-360 Datasheet (PDF) The ENP-360 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-360-48; 48 is the nominal-voltage model code. DC output voltage 55.2 V. Rated output current 6.5 A; rated-load current range 0–6.5 A. Rated output power 359 W for this exact model, subject to input and temperature derating. Peak output current / power 8.2 A / 453 W, for up to 3 seconds. Voltage adjustment range 47.5–58.8 V using the rear adjustment control. Ripple and noise, maximum 350 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±0.5%; measured from 0% to 100% rated load. Typical efficiency 94% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC. Typical cold-start inrush 60 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.5 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 62.1–72.9 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 16. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1500 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1199.8 thousand hours minimum, Telcordia SR-332 (Bellcore); 147.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $223.76

  • ENP-360-24

    MEAN WELL ENP-360 series: Fanless Desktop AC/DC Power Supply - ENP-360-24

    MEAN WELL ENP-360-24 is a fanless ENP-360 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 27.6 V DC, 13 A rated current and 359 W rated output power. Peak output is limited to 16.3 A and 450 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-360 Datasheet (PDF) The ENP-360 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-360-24; 24 is the nominal-voltage model code. DC output voltage 27.6 V. Rated output current 13 A; rated-load current range 0–13 A. Rated output power 359 W for this exact model, subject to input and temperature derating. Peak output current / power 16.3 A / 450 W, for up to 3 seconds. Voltage adjustment range 23.5–30 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±1.0%; measured from 0% to 100% rated load. Typical efficiency 93% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC. Typical cold-start inrush 60 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.5 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 31–36.5 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 16. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1500 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. For this 12/24 nominal-voltage version, the ENP-360 pages additionally list J62368-1 (2020) and show the PSE marking. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. The ENP-360 table additionally lists J55032 (H29) for the 12/24 nominal-voltage versions. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1199.8 thousand hours minimum, Telcordia SR-332 (Bellcore); 147.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $223.76

  • ENP-360-12

    MEAN WELL ENP-360 series: Fanless Desktop AC/DC Power Supply - ENP-360-12

    MEAN WELL ENP-360-12 is a fanless ENP-360 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 13.8 V DC, 26 A rated current and 359 W rated output power. Peak output is limited to 32.6 A and 450 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-360 Datasheet (PDF) The ENP-360 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-360-12; 12 is the nominal-voltage model code. DC output voltage 13.8 V. Rated output current 26 A; rated-load current range 0–26 A. Rated output power 359 W for this exact model, subject to input and temperature derating. Peak output current / power 32.6 A / 450 W, for up to 3 seconds. Voltage adjustment range 11.5–15 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±2.0%; measured from 0% to 100% rated load. Typical efficiency 91% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 3.8 A at 115 VAC; 1.9 A at 230 VAC. Typical cold-start inrush 60 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.5 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 15.5–18.2 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 16. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1500 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. For this 12/24 nominal-voltage version, the ENP-360 pages additionally list J62368-1 (2020) and show the PSE marking. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. The ENP-360 table additionally lists J55032 (H29) for the 12/24 nominal-voltage versions. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1199.8 thousand hours minimum, Telcordia SR-332 (Bellcore); 147.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $223.76

  • ENP-240-48

    MEAN WELL ENP-240 series: Fanless Desktop AC/DC Power Supply - ENP-240-48

    MEAN WELL ENP-240-48 is a fanless ENP-240 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 55.2 V DC, 4.4 A rated current and 243 W rated output power. Peak output is limited to 5.5 A and 304 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-240 Datasheet (PDF) The ENP-240 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-240-48; 48 is the nominal-voltage model code. DC output voltage 55.2 V. Rated output current 4.4 A; rated-load current range 0–4.4 A. Rated output power 243 W for this exact model, subject to input and temperature derating. Peak output current / power 5.5 A / 304 W, for up to 3 seconds. Voltage adjustment range 47.5–58.8 V using the rear adjustment control. Ripple and noise, maximum 350 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±0.5%; measured from 0% to 100% rated load. Typical efficiency 94% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC. Typical cold-start inrush 75 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 62.1–72.9 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 12. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1230 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1573.4 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $182.36

  • ENP-240-24

    MEAN WELL ENP-240 series: Fanless Desktop AC/DC Power Supply - ENP-240-24

    MEAN WELL ENP-240-24 is a fanless ENP-240 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 27.6 V DC, 8.7 A rated current and 240.1 W rated output power. Peak output is limited to 10.9 A and 300 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-240 Datasheet (PDF) The ENP-240 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-240-24; 24 is the nominal-voltage model code. DC output voltage 27.6 V. Rated output current 8.7 A; rated-load current range 0–8.7 A. Rated output power 240.1 W for this exact model, subject to input and temperature derating. Peak output current / power 10.9 A / 300 W, for up to 3 seconds. Voltage adjustment range 23.5–30 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±1.0%; measured from 0% to 100% rated load. Typical efficiency 93.5% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC. Typical cold-start inrush 75 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 31–36.5 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 12. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1230 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1573.4 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $182.36

  • ENP-240-12

    MEAN WELL ENP-240 series: Fanless Desktop AC/DC Power Supply - ENP-240-12

    MEAN WELL ENP-240-12 is a fanless ENP-240 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 13.8 V DC, 17.4 A rated current and 240.1 W rated output power. Peak output is limited to 21.7 A and 300 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-240 Datasheet (PDF) The ENP-240 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-240-12; 12 is the nominal-voltage model code. DC output voltage 13.8 V. Rated output current 17.4 A; rated-load current range 0–17.4 A. Rated output power 240.1 W for this exact model, subject to input and temperature derating. Peak output current / power 21.7 A / 300 W, for up to 3 seconds. Voltage adjustment range 11.5–15 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±2.0%; measured from 0% to 100% rated load. Typical efficiency 91% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 2.5 A at 115 VAC; 1.25 A at 230 VAC. Typical cold-start inrush 75 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 15.5–18.2 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 12. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1230 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1573.4 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $182.36

  • ENP-180-48

    MEAN WELL ENP-180 series: Fanless Desktop AC/DC Power Supply - ENP-180-48

    MEAN WELL ENP-180-48 is a fanless ENP-180 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 55.2 V DC, 3.3 A rated current and 182 W rated output power. Peak output is limited to 4.1 A and 226 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-180 Datasheet (PDF) The ENP-180 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-180-48; 48 is the nominal-voltage model code. DC output voltage 55.2 V. Rated output current 3.3 A; rated-load current range 0–3.3 A. Rated output power 182 W for this exact model, subject to input and temperature derating. Peak output current / power 4.1 A / 226 W, for up to 3 seconds. Voltage adjustment range 47.5–58.8 V using the rear adjustment control. Ripple and noise, maximum 350 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±0.5%; measured from 0% to 100% rated load. Typical efficiency 94% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 62.1–72.9 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 8. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1150 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1600.7 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $159.19

  • ENP-180-24

    MEAN WELL ENP-180 series: Fanless Desktop AC/DC Power Supply - ENP-180-24

    MEAN WELL ENP-180-24 is a fanless ENP-180 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 27.6 V DC, 6.5 A rated current and 179 W rated output power. Peak output is limited to 8.1 A and 224 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-180 Datasheet (PDF) The ENP-180 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-180-24; 24 is the nominal-voltage model code. DC output voltage 27.6 V. Rated output current 6.5 A; rated-load current range 0–6.5 A. Rated output power 179 W for this exact model, subject to input and temperature derating. Peak output current / power 8.1 A / 224 W, for up to 3 seconds. Voltage adjustment range 23.5–30 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±1.0%; measured from 0% to 100% rated load. Typical efficiency 93.5% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 31–36.5 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 8. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1150 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1600.7 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $159.19

  • ENP-180-12

    MEAN WELL ENP-180 series: Fanless Desktop AC/DC Power Supply - ENP-180-12

    MEAN WELL ENP-180-12 is a fanless ENP-180 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 13.8 V DC, 13 A rated current and 179 W rated output power. Peak output is limited to 16.3 A and 225 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-180 Datasheet (PDF) The ENP-180 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-180-12; 12 is the nominal-voltage model code. DC output voltage 13.8 V. Rated output current 13 A; rated-load current range 0–13 A. Rated output power 179 W for this exact model, subject to input and temperature derating. Peak output current / power 16.3 A / 225 W, for up to 3 seconds. Voltage adjustment range 11.5–15 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±2.0%; measured from 0% to 100% rated load. Typical efficiency 91% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.9 A at 115 VAC; 0.95 A at 230 VAC. Typical cold-start inrush 70 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 15.5–18.2 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 8. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Mounting features Two holes marked 2-M3 L=5 in the drawing; hole centres are 78 mm apart, 47.5 mm from the right edge, with the upper hole 50 mm from the top edge. Use the installation drawing and the supplied unit’s mounting instructions. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 1150 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1600.7 thousand hours minimum, Telcordia SR-332 (Bellcore); 170.6 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $159.19

  • ENP-120-48

    MEAN WELL ENP-120 series: Fanless Desktop AC/DC Power Supply - ENP-120-48

    MEAN WELL ENP-120-48 is a fanless ENP-120 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 55.2 V DC, 2.2 A rated current and 121 W rated output power. Peak output is limited to 2.75 A and 151.8 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-120 Datasheet (PDF) The ENP-120 section is on PDF pages 1, 2, 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-120-48; 48 is the nominal-voltage model code. DC output voltage 55.2 V. Rated output current 2.2 A; rated-load current range 0–2.2 A. Rated output power 121 W for this exact model, subject to input and temperature derating. Peak output current / power 2.75 A / 151.8 W, for up to 3 seconds. Voltage adjustment range 47.5–58.8 V using the rear adjustment control. Ripple and noise, maximum 350 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±0.5%; measured from 0% to 100% rated load. Typical efficiency 91.5% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 62.1–72.9 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252A. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 4. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 980 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1997.9 thousand hours minimum, Telcordia SR-332 (Bellcore); 257.1 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $134.55

  • ENP-120-24

    MEAN WELL ENP-120 series: Fanless Desktop AC/DC Power Supply - ENP-120-24

    MEAN WELL ENP-120-24 is a fanless ENP-120 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 27.6 V DC, 4.3 A rated current and 119 W rated output power. Peak output is limited to 5.38 A and 148.5 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-120 Datasheet (PDF) The ENP-120 section is on PDF pages 1, 2, 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-120-24; 24 is the nominal-voltage model code. DC output voltage 27.6 V. Rated output current 4.3 A; rated-load current range 0–4.3 A. Rated output power 119 W for this exact model, subject to input and temperature derating. Peak output current / power 5.38 A / 148.5 W, for up to 3 seconds. Voltage adjustment range 23.5–30 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±1.0%; measured from 0% to 100% rated load. Typical efficiency 91% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 31–36.5 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252A. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 4. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 980 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1997.9 thousand hours minimum, Telcordia SR-332 (Bellcore); 257.1 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $134.55

  • ENP-120-12

    MEAN WELL ENP-120 series: Fanless Desktop AC/DC Power Supply - ENP-120-12

    MEAN WELL ENP-120-12 is a fanless ENP-120 desktop AC/DC power supply for land mobile radio, surveillance and TV antenna equipment. It provides 13.8 V DC, 8.7 A rated current and 120 W rated output power. Peak output is limited to 10.9 A and 150.4 W for up to 3 seconds; input-voltage and temperature derating apply. Product Datasheet Download MEAN WELL ENP-120 Datasheet (PDF) The ENP-120 section is on PDF pages 1, 2, 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model-Specific DC Output Complete model ENP-120-12; 12 is the nominal-voltage model code. DC output voltage 13.8 V. Rated output current 8.7 A; rated-load current range 0–8.7 A. Rated output power 120 W for this exact model, subject to input and temperature derating. Peak output current / power 10.9 A / 150.4 W, for up to 3 seconds. Voltage adjustment range 11.5–15 V using the rear adjustment control. Ripple and noise, maximum 150 mVp-p under the stated measurement conditions. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%; low line to high line at rated load. Load regulation ±2.0%; measured from 0% to 100% rated load. Typical efficiency 89.5% under the default specification test conditions. The series provides 125% peak-load capability, with the exact model’s peak current and power shown above. Limit peak operation to 3 seconds and observe both current and power limits. The adjustable voltage range does not increase the rated current or available continuous power. Input, Timing and Efficiency Input voltage / frequency 90–264 VAC or 127–370 VDC; AC frequency 47–63 Hz. AC inlet / grounding Three-contact AC inlet is shown at the rear. The block diagram identifies a frame-ground (FG) connection. Power-factor correction Built-in active PFC; typical PF >0.98 at 115 VAC and >0.95 at 230 VAC, at full load. Typical AC input current 1.25 A at 115 VAC; 0.63 A at 230 VAC. Typical cold-start inrush 65 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. No-load power consumption Less than 0.15 W. Set-up / rise time 1000 / 100 ms at full load. Set-up time is measured at a cold first start; rapid switching OFF and ON may increase it. Typical hold-up time 20 ms at full load. Catalogue energy-efficiency statements Level VI; the catalogue states compliance with EISA 2007/DoE, NRCan and EU ErP. Protection Functions Short circuit Constant-current limiting; automatic recovery after the fault is removed. Overload, 110–125% of rated power If the peak-load condition continues beyond 3 seconds, the supply switches to constant-current limiting; automatic recovery after that load condition is removed. Overload above 125% of rated power Constant-current limiting, with automatic recovery after the overload is removed. Overvoltage 15.5–18.2 V; output shutdown, followed by re-powering to recover. Overtemperature Output shutdown; automatic recovery after temperature decreases. Protection operation does not extend the 3-second peak rating or the permitted continuous load. Cooling, Environment and Derating Cooling / orientation Fanless free-air convection; the load-temperature curve is specified for horizontal installation. Keep ventilation openings and the surrounding air path unobstructed. Working temperature -30°C to +70°C, with load derating. Horizontal thermal curve 100% rated load from -30°C to +50°C; reduce along the plotted line to 60% at +70°C. Input-voltage load curve At 60 Hz: 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC, before temperature derating. Above 2000 m For this fanless model, reduce the permissible ambient temperature by 3.5°C per additional 1000 m, as directed by the altitude note. Working humidity 20–95% RH, non-condensing. Storage temperature / humidity -40°C to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.05%/°C from 0°C to +50°C. Vibration 10–500 Hz, 2 G; 10-minute cycle, 60 minutes each along X, Y and Z. Apply the input-voltage and ambient-temperature limits together. The stated temperature range is not a full-load rating at every temperature. Dimensions, Wiring and Installation Body dimensions, L × W × H 192 × 178 × 45.5 mm; case 252A. The width corresponds to the 7-inch format used in land mobile radio equipment. Mechanical layout See physical catalogue page 4. Dimensions are in mm with ±1 mm drawing tolerance; the side view separately marks a 4.3 mm foot projection. Front and rear controls Front power switch and LED indicator; rear AC inlet, TB1 DC terminals and VR output-voltage adjustment. TB1 DC output terminals Pins 1 and 2: +V; pins 3 and 4: −V. These are duplicate connections for the same single DC output. Connection wire size 0.5–4.0 mm² cross-section; the catalogue gives 12–20 AWG. Wire preparation / terminal torque Recommended strip length: 9 mm. Screw torque: 4.0 lb-in (0.4–0.5 N·m). Catalogue unit packing reference 980 g per unit; carton quantities and carton mass are separate packing information. Select suitable mains and load wiring for the actual installation. These ENP pages do not specify a separately orderable connector kit, bracket or power-cord part number, or identify a supplied external cable set; confirm the required external parts when ordering. Safety, EMC and Reliability Safety standards listed The catalogue lists IEC 62368-1, UL 62368-1 and EAC TP TC 004 as approved, and compliance with BS EN/EN 62368-1. Dielectric withstand Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, at 500 VDC, 25°C and 70% RH. Conducted / radiated emission Class B to BS EN/EN 55032 (CISPR 32) and FCC Part 15 (CISPR 22), as listed in the catalogue. Harmonics / flicker BS EN/EN 61000-3-2 / BS EN/EN 61000-3-3. Immunity standards listed BS EN/EN 55024. ESD / radiated RF EN 61000-4-2: 8 kV air, level 3; 4 kV contact, level 2. EN 61000-4-3: 3 V/m, level 2. EFT / surge EN 61000-4-4: 1 kV, level 2. EN 61000-4-5: 1 kV line–line, level 2; 2 kV line–earth, level 3. Conducted RF / magnetic field EN 61000-4-6: 3 Vrms, level 2. EN 61000-4-8: 1 A/m, level 1. Voltage dips / interruptions EN 61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. MTBF references 1997.9 thousand hours minimum, Telcordia SR-332 (Bellcore); 257.1 thousand hours minimum, MIL-HDBK-217F at 25°C. Catalogue warranty 3 years. These are the 2026-03-31 catalogue statements for the specified power supply. Confirm that the completed equipment and its actual installation meet the applicable EMC requirements. Measurement Conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise use 20 MHz bandwidth with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors.

    $134.55