General Family Features

The MEAN WELL HRP and HRPG series represent a premium, highly reliable line of enclosed power supplies featuring active Power Factor Correction (PFC) across the entire range.

Robust & Reliable

  • All models are meticulously built using 105°C long life electrolytic capacitors.
  • They are capable of withstanding a 300VAC surge input for 5 seconds.
  • The entire product family provides peace of mind with a comprehensive 5 years warranty.

Efficient & Safe

  • They feature a Universal AC input / Full range.
  • Comprehensive protections include Short circuit / Overload / Over voltage / Over temperature.
  • Built-in remote ON-OFF control is standard.
  • A constant current limiting circuit is employed for reliable overload protection.

Understanding the HRPG "Green Power" Advantage

While the HRP series serves as a standard premium power supply, the HRPG series introduces advanced energy-saving "Green" functions designed for high-efficiency, eco-friendly systems.

  • Ultra-Low Standby Power: HRPG models (from 150W up to 600W) feature an exceptionally low no-load power consumption, typically < 0.5W to < 0.75W depending on the wattage.
  • Auxiliary Standby Output: HRPG models are exclusively equipped with a 5V@0.3A standby output. This ensures continuous power is supplied to essential control circuits even when the main output is turned off.
  • Parallel Function (Current Sharing): The high-power HRPG series is designed for scalability. The HRPG-600 supports parallel operation up to 2400W (3+1) for its 24V, 36V, and 48V models. The flagship HRPG-1000 supports parallel operation up to 4000W (3+1).

Mid-Power Specifications (75W ~ 200W)

The lower wattage ranges in this family are cooled entirely by free air convection, ensuring silent operation, and maintain a 1U low profile height of just 38mm.

Series Model HRP-75 HRP-100 HRP/HRPG-150 HRP/HRPG-200
Max Rated Power Up to 76.8W Up to 108W Up to 158.4W Up to 206.4W
DC Voltages Available 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V
Max Efficiency (Typ.) Up to 89% Up to 90% Up to 89% Up to 89%
Remote Sense N/A N/A Built-in Built-in

High-Power Specifications (300W ~ 1000W)

The higher power models utilize a built-in cooling fan with fan ON/OFF control to manage thermals effectively. Furthermore, they are equipped with a built-in remote sense function and output a DC OK signal.

Series Model HRP/HRPG-300 HRP/HRPG-450 HRP/HRPG-600 HRPG-1000
Max Rated Power Up to 336W Up to 456W Up to 648W Up to 1008W
DC Voltages Available 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V 12V, 15V, 24V, 48V
Max Efficiency (Typ.) Up to 89% Up to 89.5% Up to 89% Up to 94%
Parallel Function N/A N/A Up to 2400W (HRPG only) Up to 4000W

Dimensions & Ordering Guide

Physical Dimensions (L*W*H)

The HRP family maintains a standardized, compact form factor even at high wattages. Impressively, the 600W and 1000W models share the exact same enclosure dimensions.

  • 75W: 129 * 98 * 38 mm
  • 100W / 150W: 159 * 97 * 38 mm
  • 200W: 199 * 98 * 38 mm
  • 300W: 199 * 105 * 41 mm
  • 450W: 218 * 105 * 41 mm
  • 600W / 1000W: 218 * 105 * 63.5 mm

Product Ordering Code Breakdown

No. Item Code / Value Description
1 Series Name HRP / HRPG HRP = Standard; HRPG = Green Power (Standby function & Low no-load power)
2 Rated Wattage 75 / 100 / 150 / 200 / 300 / 450 / 600 / 1000 Approximate output power rating in Watts
3 Output Voltage 3.3 / 5 / 7.5 / 12 / 15 / 24 / 36 / 48 DC Voltage Output
Example 1: HRP-100-12 represents a standard 100W power supply with a 12V DC output.
Example 2: HRPG-600-24 represents a 600W Green power supply (with parallel capability) and a 24V DC output.
Example 3: HRPG-1000-48 represents the flagship 1000W Green power supply featuring parallel capability and a 48V DC output.
  • HRPG-1000-48

    MEAN WELL HRPG-1000 series: single-output enclosed AC/DC power supply with PFC and current sharing - HRPG-1000-48

    MEAN WELL HRPG-1000-48 is a single-output enclosed industrial AC/DC power supply rated at 48 V DC, 21 A and 1008 W. It provides active PFC, built-in fan cooling, remote sensing, remote ON/OFF, a 5 V standby output and active current sharing. Apply the model-specific temperature, input-voltage and parallel-operation limits below. Product Datasheet Download MEAN WELL HRPG-1000 Datasheet (PDF) The HRPG-1000 section is on PDF pages 33, 34, 35, 36, 37, 38. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Ratings Complete model HRPG-1000-48 Nominal DC output / rated current 48 V / 21 A Rated output power 1008 W rated Output current range 0 to 21 A Local output-voltage adjustment 46 to 56 V using VADJ Ripple and noise, maximum 250 mVp-p Voltage tolerance / line / load regulation ±1.0% / ±0.5% / ±0.5% Typical efficiency 94% In HRPG-1000-48, HRPG is the series, 1000 is the power-class code and 48 is the output-voltage code. Use the actual rating above for load selection. Unless otherwise stated, ratings are measured at 230 VAC input, rated load and 25°C. Ripple is measured at 20 MHz bandwidth with a 12-inch twisted-pair lead terminated by 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Start-up Input voltage / frequency 90 to 264 VAC, 47 to 63 Hz; or 127 to 370 VDC Short-duration input withstand 300 VAC for 5 seconds Typical power factor PF >0.95 at 230 VAC; PF >0.99 at 115 VAC, full load Typical AC current / inrush 8.5 A / 25 A at 115 VAC; 5 A / 40 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise / hold-up Setup: 1000 ms at 230 VAC or 2000 ms at 115 VAC; rise: 50 ms; typical hold-up: 16 ms at either input, full load Low-power standby <0.75 W with CN100 RC+ pin 3 and RC- pin 4 open The 300 VAC figure is a five-second withstand condition, not the continuous input rating. Setup time is measured at the first cold start; repeated ON/OFF switching may increase setup time. Protection Short-circuit / overload protection Constant-current limiting at 105 to 135% rated output power; automatic recovery after the fault is removed Overvoltage threshold / recovery 58 to 65 V; output shuts down, re-power to recover Overtemperature protection Output shuts down; automatic recovery after temperature falls Cooling, Environment and Derating Cooling Built-in fan with temperature/load-controlled ON/OFF operation; catalog control reference: NTC (RT50) or 30% load minimum Model-specific temperature curve At horizontal mounting: 100% rated load through 60°C; derate along the catalog curve to 60% at 70°C. Low-input derating At 60 Hz: 80% load at 90 VAC, increasing along the curve to 100% at 200 VAC; 100% from 200 to 264 VAC Humidity / storage Operating: 20 to 90% RH, non-condensing. Storage: -40 to +85°C, 10 to 95% RH Temperature coefficient / altitude ±0.03%/°C from 0 to 50°C. For this fan-cooled model, reduce the ambient-temperature rating by 5°C per 1000 m above 2000 m altitude The family operating range is listed as -40 to +70°C, subject to the model-specific derating curve above. Keep the fan and ventilation openings clear and follow the airflow direction in the mechanical drawing; the top ambient temperature is not a full-load rating. Remote Control, Sensing and Auxiliary Output Remote ON/OFF Short CN100 RC+ pin 3 to RC- pin 4 for main output ON; open for OFF Remote sense Connect +S pin 9 to the positive load terminal and -S pin 10 to the negative load terminal using a twisted pair; maximum line-drop compensation is 0.5 V DC-OK status output TTL signal at pin 7 relative to GND: 3.3 to 5.6 V when ON, 0 to 1 V when OFF 5 V standby / auxiliary output Pin 2 AUX relative to pin 1 AUXG: 4.75 to 5.25 V, up to 0.3 A, maximum ripple 50 mVp-p; remains available independently of remote ON/OFF CN100 Control Connector Pin Assignment 1 — AUXG Auxiliary-output ground 2 — AUX 5 V auxiliary output, referenced to pin 1 3 — RC+ Remote-control positive contact 4 — RC- Remote-control ground 5 — CS Active current-sharing signal; interconnect CS pins for parallel operation 6 and 8 — GND Connected to main negative output -V; DC-OK return 7 — DC-OK TTL power-status output; function table specifies pin 8 as its reference 9 — +S Positive load-sense connection 10 — -S Negative load-sense connection Use the numbered connector orientation in the PDF mechanical drawing. AUXG and the main-output GND have different functions; wire each signal to its stated reference. Active Current Sharing Maximum parallel group Up to 4 units Voltage matching Output-voltage difference among parallel units must be less than 0.2 V Maximum total output current 21 A × number of units × 0.9; for 4 units, 75.6 A maximum before any additional applicable derating Use short, large-diameter power wiring to the common load. Interconnect the CS pin 5 signals and the GND return bus as shown in the parallel diagram; apply the specified RC+ / RC- ON connection to each unit. Below 5% of the combined rated current, sharing among the units may be unbalanced. The catalog headline of up to 4000 W does not override the current formula, each model's actual rating or input/temperature limits. Dimensions, Installation and Reference Weight Case dimensions / drawing tolerance 218 × 105 × 63.5 mm (L × W × H); case No. 977, drawing tolerance ±1 mm Mounting callouts 4-M4 L=6; 8-M4 L=4 on both sides, as shown in the mechanical drawing Terminal projection allowance Input projection: 12 mm maximum; output projection: 18 mm maximum, as dimensioned in the drawing AC input terminals 1: AC/L; 2: AC/N; 3: FG protective earth DC output terminals 1 to 3: +V; 4 to 6: -V Reference unit weight 1.53 kg (1530 g), from the manufacturer's per-unit packing entry The drawing identifies a power-on LED and a VADJ control at the output end. Use the complete drawing for mounting-hole coordinates, connector orientation and installation clearance. The reference weight is the catalog per-unit packing value, not a measured net weight or a shipping quotation. Compatible Connector Components CN100 board connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact family HRS DF11-**SC or equivalent DF11-**SC is the catalog contact-family notation, not a complete contact order code. Select the exact contact variant to suit the wire and mating housing. Confirm the supply of mating housings, contacts and any assembled control cable when ordering. Safety, EMC and Reliability Catalog safety approvals UL62368-1; CAN/CSA C22.2 No. 62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004 Dielectric withstand / insulation Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC. Insulation: 100 MΩ at 500 VDC, 25°C / 70% RH EMC emissions BS EN/EN55032 (CISPR32) Class B conducted and radiated; harmonic current BS EN/EN61000-3-2 Class A; voltage flicker BS EN/EN61000-3-3 EMC immunity BS EN/EN55024 and BS EN/EN61000-6-2; ESD 8 kV air / 4 kV contact; radiated RF and EFT/burst Level 3; surge 2 kV line-line / 4 kV line-earth; conducted immunity Level 3; magnetic field Level 4. Voltage dips/interruption tests: >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods Vibration / calculated MTBF 10 to 500 Hz, 5 G, 10 min/cycle, 60 min per X/Y/Z axis. MTBF: 286.6k h minimum Telcordia SR-332; 105.8k h minimum MIL-HDBK-217F at 25°C Manufacturer catalog warranty 5 years The power supply is a component for installation in final equipment. The catalog EMC tests used a 360 × 720 mm metal plate of 1 mm thickness; the finished equipment must be checked for its own EMC compliance. MTBF is a calculated reliability measure, not a promised service life.

    $640.71

  • HRPG-1000-24

    MEAN WELL HRPG-1000 series: single-output enclosed AC/DC power supply with PFC and current sharing - HRPG-1000-24

    MEAN WELL HRPG-1000-24 is a single-output enclosed industrial AC/DC power supply rated at 24 V DC, 42 A and 1008 W. It provides active PFC, built-in fan cooling, remote sensing, remote ON/OFF, a 5 V standby output and active current sharing. Apply the model-specific temperature, input-voltage and parallel-operation limits below. Product Datasheet Download MEAN WELL HRPG-1000 Datasheet (PDF) The HRPG-1000 section is on PDF pages 33, 34, 35, 36, 37, 38. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Ratings Complete model HRPG-1000-24 Nominal DC output / rated current 24 V / 42 A Rated output power 1008 W rated Output current range 0 to 42 A Local output-voltage adjustment 22 to 28 V using VADJ Ripple and noise, maximum 200 mVp-p Voltage tolerance / line / load regulation ±1.0% / ±0.5% / ±0.5% Typical efficiency 93% In HRPG-1000-24, HRPG is the series, 1000 is the power-class code and 24 is the output-voltage code. Use the actual rating above for load selection. Unless otherwise stated, ratings are measured at 230 VAC input, rated load and 25°C. Ripple is measured at 20 MHz bandwidth with a 12-inch twisted-pair lead terminated by 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Start-up Input voltage / frequency 90 to 264 VAC, 47 to 63 Hz; or 127 to 370 VDC Short-duration input withstand 300 VAC for 5 seconds Typical power factor PF >0.95 at 230 VAC; PF >0.99 at 115 VAC, full load Typical AC current / inrush 8.5 A / 25 A at 115 VAC; 5 A / 40 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise / hold-up Setup: 1000 ms at 230 VAC or 2000 ms at 115 VAC; rise: 50 ms; typical hold-up: 16 ms at either input, full load Low-power standby <0.75 W with CN100 RC+ pin 3 and RC- pin 4 open The 300 VAC figure is a five-second withstand condition, not the continuous input rating. Setup time is measured at the first cold start; repeated ON/OFF switching may increase setup time. Protection Short-circuit / overload protection Constant-current limiting at 105 to 135% rated output power; automatic recovery after the fault is removed Overvoltage threshold / recovery 29 to 33 V; output shuts down, re-power to recover Overtemperature protection Output shuts down; automatic recovery after temperature falls Cooling, Environment and Derating Cooling Built-in fan with temperature/load-controlled ON/OFF operation; catalog control reference: NTC (RT50) or 30% load minimum Model-specific temperature curve At horizontal mounting: 100% rated load through 60°C; derate along the catalog curve to 60% at 70°C. Low-input derating At 60 Hz: 80% load at 90 VAC, increasing along the curve to 100% at 200 VAC; 100% from 200 to 264 VAC Humidity / storage Operating: 20 to 90% RH, non-condensing. Storage: -40 to +85°C, 10 to 95% RH Temperature coefficient / altitude ±0.03%/°C from 0 to 50°C. For this fan-cooled model, reduce the ambient-temperature rating by 5°C per 1000 m above 2000 m altitude The family operating range is listed as -40 to +70°C, subject to the model-specific derating curve above. Keep the fan and ventilation openings clear and follow the airflow direction in the mechanical drawing; the top ambient temperature is not a full-load rating. Remote Control, Sensing and Auxiliary Output Remote ON/OFF Short CN100 RC+ pin 3 to RC- pin 4 for main output ON; open for OFF Remote sense Connect +S pin 9 to the positive load terminal and -S pin 10 to the negative load terminal using a twisted pair; maximum line-drop compensation is 0.5 V DC-OK status output TTL signal at pin 7 relative to GND: 3.3 to 5.6 V when ON, 0 to 1 V when OFF 5 V standby / auxiliary output Pin 2 AUX relative to pin 1 AUXG: 4.75 to 5.25 V, up to 0.3 A, maximum ripple 50 mVp-p; remains available independently of remote ON/OFF CN100 Control Connector Pin Assignment 1 — AUXG Auxiliary-output ground 2 — AUX 5 V auxiliary output, referenced to pin 1 3 — RC+ Remote-control positive contact 4 — RC- Remote-control ground 5 — CS Active current-sharing signal; interconnect CS pins for parallel operation 6 and 8 — GND Connected to main negative output -V; DC-OK return 7 — DC-OK TTL power-status output; function table specifies pin 8 as its reference 9 — +S Positive load-sense connection 10 — -S Negative load-sense connection Use the numbered connector orientation in the PDF mechanical drawing. AUXG and the main-output GND have different functions; wire each signal to its stated reference. Active Current Sharing Maximum parallel group Up to 4 units Voltage matching Output-voltage difference among parallel units must be less than 0.2 V Maximum total output current 42 A × number of units × 0.9; for 4 units, 151.2 A maximum before any additional applicable derating Use short, large-diameter power wiring to the common load. Interconnect the CS pin 5 signals and the GND return bus as shown in the parallel diagram; apply the specified RC+ / RC- ON connection to each unit. Below 5% of the combined rated current, sharing among the units may be unbalanced. The catalog headline of up to 4000 W does not override the current formula, each model's actual rating or input/temperature limits. Dimensions, Installation and Reference Weight Case dimensions / drawing tolerance 218 × 105 × 63.5 mm (L × W × H); case No. 977, drawing tolerance ±1 mm Mounting callouts 4-M4 L=6; 8-M4 L=4 on both sides, as shown in the mechanical drawing Terminal projection allowance Input projection: 12 mm maximum; output projection: 18 mm maximum, as dimensioned in the drawing AC input terminals 1: AC/L; 2: AC/N; 3: FG protective earth DC output terminals 1 to 3: +V; 4 to 6: -V Reference unit weight 1.53 kg (1530 g), from the manufacturer's per-unit packing entry The drawing identifies a power-on LED and a VADJ control at the output end. Use the complete drawing for mounting-hole coordinates, connector orientation and installation clearance. The reference weight is the catalog per-unit packing value, not a measured net weight or a shipping quotation. Compatible Connector Components CN100 board connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact family HRS DF11-**SC or equivalent DF11-**SC is the catalog contact-family notation, not a complete contact order code. Select the exact contact variant to suit the wire and mating housing. Confirm the supply of mating housings, contacts and any assembled control cable when ordering. Safety, EMC and Reliability Catalog safety approvals UL62368-1; CAN/CSA C22.2 No. 62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004 Dielectric withstand / insulation Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC. Insulation: 100 MΩ at 500 VDC, 25°C / 70% RH EMC emissions BS EN/EN55032 (CISPR32) Class B conducted and radiated; harmonic current BS EN/EN61000-3-2 Class A; voltage flicker BS EN/EN61000-3-3 EMC immunity BS EN/EN55024 and BS EN/EN61000-6-2; ESD 8 kV air / 4 kV contact; radiated RF and EFT/burst Level 3; surge 2 kV line-line / 4 kV line-earth; conducted immunity Level 3; magnetic field Level 4. Voltage dips/interruption tests: >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods Vibration / calculated MTBF 10 to 500 Hz, 5 G, 10 min/cycle, 60 min per X/Y/Z axis. MTBF: 286.6k h minimum Telcordia SR-332; 105.8k h minimum MIL-HDBK-217F at 25°C Manufacturer catalog warranty 5 years The power supply is a component for installation in final equipment. The catalog EMC tests used a 360 × 720 mm metal plate of 1 mm thickness; the finished equipment must be checked for its own EMC compliance. MTBF is a calculated reliability measure, not a promised service life.

    $640.71

  • HRPG-1000-15

    MEAN WELL HRPG-1000 series: single-output enclosed AC/DC power supply with PFC and current sharing - HRPG-1000-15

    MEAN WELL HRPG-1000-15 is a single-output enclosed industrial AC/DC power supply rated at 15 V DC, 64 A and 960 W. It provides active PFC, built-in fan cooling, remote sensing, remote ON/OFF, a 5 V standby output and active current sharing. Apply the model-specific temperature, input-voltage and parallel-operation limits below. Product Datasheet Download MEAN WELL HRPG-1000 Datasheet (PDF) The HRPG-1000 section is on PDF pages 33, 34, 35, 36, 37, 38. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Ratings Complete model HRPG-1000-15 Nominal DC output / rated current 15 V / 64 A Rated output power 960 W continuous; up to 1000 W for 3 seconds Output current range 0 to 64 A Local output-voltage adjustment 14 to 17 V using VADJ Ripple and noise, maximum 150 mVp-p Voltage tolerance / line / load regulation ±1.5% / ±0.5% / ±1.5% Typical efficiency 92% In HRPG-1000-15, HRPG is the series, 1000 is the power-class code and 15 is the output-voltage code. Use the actual rating above for load selection. Unless otherwise stated, ratings are measured at 230 VAC input, rated load and 25°C. Ripple is measured at 20 MHz bandwidth with a 12-inch twisted-pair lead terminated by 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Start-up Input voltage / frequency 90 to 264 VAC, 47 to 63 Hz; or 127 to 370 VDC Short-duration input withstand 300 VAC for 5 seconds Typical power factor PF >0.95 at 230 VAC; PF >0.99 at 115 VAC, full load Typical AC current / inrush 8.5 A / 25 A at 115 VAC; 5 A / 40 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise / hold-up Setup: 1000 ms at 230 VAC or 2000 ms at 115 VAC; rise: 50 ms; typical hold-up: 16 ms at either input, full load Low-power standby <0.75 W with CN100 RC+ pin 3 and RC- pin 4 open The 300 VAC figure is a five-second withstand condition, not the continuous input rating. Setup time is measured at the first cold start; repeated ON/OFF switching may increase setup time. Protection Short-circuit / overload protection Constant-current limiting at 105 to 135% rated output power; automatic recovery after the fault is removed Overvoltage threshold / recovery 18.2 to 20.6 V; output shuts down, re-power to recover Overtemperature protection Output shuts down; automatic recovery after temperature falls Cooling, Environment and Derating Cooling Built-in fan with temperature/load-controlled ON/OFF operation; catalog control reference: NTC (RT50) or 30% load minimum Model-specific temperature curve At horizontal mounting: 100% rated load through 50°C; derate along the catalog curve to 60% at 60°C. The 12/15 V curve ends at 60°C. Low-input derating At 60 Hz: 80% load at 90 VAC, increasing along the curve to 100% at 200 VAC; 100% from 200 to 264 VAC Humidity / storage Operating: 20 to 90% RH, non-condensing. Storage: -40 to +85°C, 10 to 95% RH Temperature coefficient / altitude ±0.03%/°C from 0 to 50°C. For this fan-cooled model, reduce the ambient-temperature rating by 5°C per 1000 m above 2000 m altitude The family operating range is listed as -40 to +70°C, subject to the model-specific derating curve above. Keep the fan and ventilation openings clear and follow the airflow direction in the mechanical drawing; the top ambient temperature is not a full-load rating. Remote Control, Sensing and Auxiliary Output Remote ON/OFF Short CN100 RC+ pin 3 to RC- pin 4 for main output ON; open for OFF Remote sense Connect +S pin 9 to the positive load terminal and -S pin 10 to the negative load terminal using a twisted pair; maximum line-drop compensation is 0.5 V DC-OK status output TTL signal at pin 7 relative to GND: 3.3 to 5.6 V when ON, 0 to 1 V when OFF 5 V standby / auxiliary output Pin 2 AUX relative to pin 1 AUXG: 4.75 to 5.25 V, up to 0.3 A, maximum ripple 50 mVp-p; remains available independently of remote ON/OFF CN100 Control Connector Pin Assignment 1 — AUXG Auxiliary-output ground 2 — AUX 5 V auxiliary output, referenced to pin 1 3 — RC+ Remote-control positive contact 4 — RC- Remote-control ground 5 — CS Active current-sharing signal; interconnect CS pins for parallel operation 6 and 8 — GND Connected to main negative output -V; DC-OK return 7 — DC-OK TTL power-status output; function table specifies pin 8 as its reference 9 — +S Positive load-sense connection 10 — -S Negative load-sense connection Use the numbered connector orientation in the PDF mechanical drawing. AUXG and the main-output GND have different functions; wire each signal to its stated reference. Active Current Sharing Maximum parallel group Up to 4 units Voltage matching Output-voltage difference among parallel units must be less than 0.2 V Maximum total output current 64 A × number of units × 0.9; for 4 units, 230.4 A maximum before any additional applicable derating Use short, large-diameter power wiring to the common load. Interconnect the CS pin 5 signals and the GND return bus as shown in the parallel diagram; apply the specified RC+ / RC- ON connection to each unit. Below 5% of the combined rated current, sharing among the units may be unbalanced. The catalog headline of up to 4000 W does not override the current formula, each model's actual rating or input/temperature limits. Dimensions, Installation and Reference Weight Case dimensions / drawing tolerance 218 × 105 × 63.5 mm (L × W × H); case No. 977, drawing tolerance ±1 mm Mounting callouts 4-M4 L=6; 8-M4 L=4 on both sides, as shown in the mechanical drawing Terminal projection allowance Input projection: 12 mm maximum; output projection: 18 mm maximum, as dimensioned in the drawing AC input terminals 1: AC/L; 2: AC/N; 3: FG protective earth DC output terminals 1 to 3: +V; 4 to 6: -V Reference unit weight 1.53 kg (1530 g), from the manufacturer's per-unit packing entry The drawing identifies a power-on LED and a VADJ control at the output end. Use the complete drawing for mounting-hole coordinates, connector orientation and installation clearance. The reference weight is the catalog per-unit packing value, not a measured net weight or a shipping quotation. Compatible Connector Components CN100 board connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact family HRS DF11-**SC or equivalent DF11-**SC is the catalog contact-family notation, not a complete contact order code. Select the exact contact variant to suit the wire and mating housing. Confirm the supply of mating housings, contacts and any assembled control cable when ordering. Safety, EMC and Reliability Catalog safety approvals UL62368-1; CAN/CSA C22.2 No. 62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004 Dielectric withstand / insulation Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC. Insulation: 100 MΩ at 500 VDC, 25°C / 70% RH EMC emissions BS EN/EN55032 (CISPR32) Class B conducted and radiated; harmonic current BS EN/EN61000-3-2 Class A; voltage flicker BS EN/EN61000-3-3 EMC immunity BS EN/EN55024 and BS EN/EN61000-6-2; ESD 8 kV air / 4 kV contact; radiated RF and EFT/burst Level 3; surge 2 kV line-line / 4 kV line-earth; conducted immunity Level 3; magnetic field Level 4. Voltage dips/interruption tests: >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods Vibration / calculated MTBF 10 to 500 Hz, 5 G, 10 min/cycle, 60 min per X/Y/Z axis. MTBF: 286.6k h minimum Telcordia SR-332; 105.8k h minimum MIL-HDBK-217F at 25°C Manufacturer catalog warranty 5 years The power supply is a component for installation in final equipment. The catalog EMC tests used a 360 × 720 mm metal plate of 1 mm thickness; the finished equipment must be checked for its own EMC compliance. MTBF is a calculated reliability measure, not a promised service life.

    $640.71

  • HRPG-1000-12

    MEAN WELL HRPG-1000 series: single-output enclosed AC/DC power supply with PFC and current sharing - HRPG-1000-12

    MEAN WELL HRPG-1000-12 is a single-output enclosed industrial AC/DC power supply rated at 12 V DC, 80 A and 960 W. It provides active PFC, built-in fan cooling, remote sensing, remote ON/OFF, a 5 V standby output and active current sharing. Apply the model-specific temperature, input-voltage and parallel-operation limits below. Product Datasheet Download MEAN WELL HRPG-1000 Datasheet (PDF) The HRPG-1000 section is on PDF pages 33, 34, 35, 36, 37, 38. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Ratings Complete model HRPG-1000-12 Nominal DC output / rated current 12 V / 80 A Rated output power 960 W continuous; up to 1000 W for 3 seconds Output current range 0 to 80 A Local output-voltage adjustment 11 to 14 V using VADJ Ripple and noise, maximum 150 mVp-p Voltage tolerance / line / load regulation ±2.0% / ±0.5% / ±2.0% Typical efficiency 91.5% In HRPG-1000-12, HRPG is the series, 1000 is the power-class code and 12 is the output-voltage code. Use the actual rating above for load selection. Unless otherwise stated, ratings are measured at 230 VAC input, rated load and 25°C. Ripple is measured at 20 MHz bandwidth with a 12-inch twisted-pair lead terminated by 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Start-up Input voltage / frequency 90 to 264 VAC, 47 to 63 Hz; or 127 to 370 VDC Short-duration input withstand 300 VAC for 5 seconds Typical power factor PF >0.95 at 230 VAC; PF >0.99 at 115 VAC, full load Typical AC current / inrush 8.5 A / 25 A at 115 VAC; 5 A / 40 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise / hold-up Setup: 1000 ms at 230 VAC or 2000 ms at 115 VAC; rise: 50 ms; typical hold-up: 16 ms at either input, full load Low-power standby <0.75 W with CN100 RC+ pin 3 and RC- pin 4 open The 300 VAC figure is a five-second withstand condition, not the continuous input rating. Setup time is measured at the first cold start; repeated ON/OFF switching may increase setup time. Protection Short-circuit / overload protection Constant-current limiting at 105 to 135% rated output power; automatic recovery after the fault is removed Overvoltage threshold / recovery 14.5 to 16.5 V; output shuts down, re-power to recover Overtemperature protection Output shuts down; automatic recovery after temperature falls Cooling, Environment and Derating Cooling Built-in fan with temperature/load-controlled ON/OFF operation; catalog control reference: NTC (RT50) or 30% load minimum Model-specific temperature curve At horizontal mounting: 100% rated load through 50°C; derate along the catalog curve to 60% at 60°C. The 12/15 V curve ends at 60°C. Low-input derating At 60 Hz: 80% load at 90 VAC, increasing along the curve to 100% at 200 VAC; 100% from 200 to 264 VAC Humidity / storage Operating: 20 to 90% RH, non-condensing. Storage: -40 to +85°C, 10 to 95% RH Temperature coefficient / altitude ±0.03%/°C from 0 to 50°C. For this fan-cooled model, reduce the ambient-temperature rating by 5°C per 1000 m above 2000 m altitude The family operating range is listed as -40 to +70°C, subject to the model-specific derating curve above. Keep the fan and ventilation openings clear and follow the airflow direction in the mechanical drawing; the top ambient temperature is not a full-load rating. Remote Control, Sensing and Auxiliary Output Remote ON/OFF Short CN100 RC+ pin 3 to RC- pin 4 for main output ON; open for OFF Remote sense Connect +S pin 9 to the positive load terminal and -S pin 10 to the negative load terminal using a twisted pair; maximum line-drop compensation is 0.5 V DC-OK status output TTL signal at pin 7 relative to GND: 3.3 to 5.6 V when ON, 0 to 1 V when OFF 5 V standby / auxiliary output Pin 2 AUX relative to pin 1 AUXG: 4.75 to 5.25 V, up to 0.3 A, maximum ripple 50 mVp-p; remains available independently of remote ON/OFF CN100 Control Connector Pin Assignment 1 — AUXG Auxiliary-output ground 2 — AUX 5 V auxiliary output, referenced to pin 1 3 — RC+ Remote-control positive contact 4 — RC- Remote-control ground 5 — CS Active current-sharing signal; interconnect CS pins for parallel operation 6 and 8 — GND Connected to main negative output -V; DC-OK return 7 — DC-OK TTL power-status output; function table specifies pin 8 as its reference 9 — +S Positive load-sense connection 10 — -S Negative load-sense connection Use the numbered connector orientation in the PDF mechanical drawing. AUXG and the main-output GND have different functions; wire each signal to its stated reference. Active Current Sharing Maximum parallel group Up to 4 units Voltage matching Output-voltage difference among parallel units must be less than 0.2 V Maximum total output current 80 A × number of units × 0.9; for 4 units, 288 A maximum before any additional applicable derating Use short, large-diameter power wiring to the common load. Interconnect the CS pin 5 signals and the GND return bus as shown in the parallel diagram; apply the specified RC+ / RC- ON connection to each unit. Below 5% of the combined rated current, sharing among the units may be unbalanced. The catalog headline of up to 4000 W does not override the current formula, each model's actual rating or input/temperature limits. Dimensions, Installation and Reference Weight Case dimensions / drawing tolerance 218 × 105 × 63.5 mm (L × W × H); case No. 977, drawing tolerance ±1 mm Mounting callouts 4-M4 L=6; 8-M4 L=4 on both sides, as shown in the mechanical drawing Terminal projection allowance Input projection: 12 mm maximum; output projection: 18 mm maximum, as dimensioned in the drawing AC input terminals 1: AC/L; 2: AC/N; 3: FG protective earth DC output terminals 1 to 3: +V; 4 to 6: -V Reference unit weight 1.53 kg (1530 g), from the manufacturer's per-unit packing entry The drawing identifies a power-on LED and a VADJ control at the output end. Use the complete drawing for mounting-hole coordinates, connector orientation and installation clearance. The reference weight is the catalog per-unit packing value, not a measured net weight or a shipping quotation. Compatible Connector Components CN100 board connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact family HRS DF11-**SC or equivalent DF11-**SC is the catalog contact-family notation, not a complete contact order code. Select the exact contact variant to suit the wire and mating housing. Confirm the supply of mating housings, contacts and any assembled control cable when ordering. Safety, EMC and Reliability Catalog safety approvals UL62368-1; CAN/CSA C22.2 No. 62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004 Dielectric withstand / insulation Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC. Insulation: 100 MΩ at 500 VDC, 25°C / 70% RH EMC emissions BS EN/EN55032 (CISPR32) Class B conducted and radiated; harmonic current BS EN/EN61000-3-2 Class A; voltage flicker BS EN/EN61000-3-3 EMC immunity BS EN/EN55024 and BS EN/EN61000-6-2; ESD 8 kV air / 4 kV contact; radiated RF and EFT/burst Level 3; surge 2 kV line-line / 4 kV line-earth; conducted immunity Level 3; magnetic field Level 4. Voltage dips/interruption tests: >95% dip for 0.5 periods, 30% dip for 25 periods, and >95% interruption for 250 periods Vibration / calculated MTBF 10 to 500 Hz, 5 G, 10 min/cycle, 60 min per X/Y/Z axis. MTBF: 286.6k h minimum Telcordia SR-332; 105.8k h minimum MIL-HDBK-217F at 25°C Manufacturer catalog warranty 5 years The power supply is a component for installation in final equipment. The catalog EMC tests used a 360 × 720 mm metal plate of 1 mm thickness; the finished equipment must be checked for its own EMC compliance. MTBF is a calculated reliability measure, not a promised service life.

    $640.71

  • HRPG-600-48

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-48

    MEAN WELL HRPG-600-48 is an enclosed AC/DC power supply rated 48 V, 13 A and 624 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. This version supports active current sharing under the conditions below. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-48 Model meaning HRPG-600 identifies the family and its nominal power class; 48 identifies the rated main-output voltage. Use the actual 624 W rating for this model. Rated main output 48 VDC / 13 A / 624 W Main current range 0 to 13 A, subject to the applicable load and derating conditions. Local voltage adjustment 40.8 to 55.2 V using SVR1 Ripple and noise 240 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 57.6–67.2 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current Sharing with Remote Sensing Active current sharing is specified for HRPG-600-24, HRPG-600-36 and HRPG-600-48. Use no more than 4 units; output-voltage differences must be less than 2%. Consult the manufacturer for larger parallel arrangements. Maximum parallel current = rated current per unit × number of units × 0.9. Use short, large-diameter power wiring; connect corresponding main +V/−V outputs and mutually connect +S, −S, CS and GND as in the complete parallel diagram. Twist the remote load-sense pair. For four identical HRPG-600-48 units, the equation gives 46.8 A maximum and 2246.4 W at nominal output voltage before additional input/thermal derating. The cover’s “up to 2400 W (3+1)” does not override this equation or certify a fault-redundancy system. A minimum 2% dummy load is required. Below the stated 2% rated-load condition, only the master may operate; slave units may enter standby and their output LED and relay may remain off. Apply the catalog’s load condition rather than expecting balanced sharing down to zero load. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $355.35

  • HRPG-600-36

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-36

    MEAN WELL HRPG-600-36 is an enclosed AC/DC power supply rated 36 V, 17.5 A and 630 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. This version supports active current sharing under the conditions below. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-36 Model meaning HRPG-600 identifies the family and its nominal power class; 36 identifies the rated main-output voltage. Use the actual 630 W rating for this model. Rated main output 36 VDC / 17.5 A / 630 W Main current range 0 to 17.5 A, subject to the applicable load and derating conditions. Local voltage adjustment 28.8 to 39.6 V using SVR1 Ripple and noise 200 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 41.4–48.6 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current Sharing with Remote Sensing Active current sharing is specified for HRPG-600-24, HRPG-600-36 and HRPG-600-48. Use no more than 4 units; output-voltage differences must be less than 2%. Consult the manufacturer for larger parallel arrangements. Maximum parallel current = rated current per unit × number of units × 0.9. Use short, large-diameter power wiring; connect corresponding main +V/−V outputs and mutually connect +S, −S, CS and GND as in the complete parallel diagram. Twist the remote load-sense pair. For four identical HRPG-600-36 units, the equation gives 63 A maximum and 2268 W at nominal output voltage before additional input/thermal derating. The cover’s “up to 2400 W (3+1)” does not override this equation or certify a fault-redundancy system. A minimum 2% dummy load is required. Below the stated 2% rated-load condition, only the master may operate; slave units may enter standby and their output LED and relay may remain off. Apply the catalog’s load condition rather than expecting balanced sharing down to zero load. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $355.35

  • HRPG-600-24

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-24

    MEAN WELL HRPG-600-24 is an enclosed AC/DC power supply rated 24 V, 27 A and 648 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. This version supports active current sharing under the conditions below. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-24 Model meaning HRPG-600 identifies the family and its nominal power class; 24 identifies the rated main-output voltage. Use the actual 648 W rating for this model. Rated main output 24 VDC / 27 A / 648 W Main current range 0 to 27 A, subject to the applicable load and derating conditions. Local voltage adjustment 21.6 to 28.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 30–34.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current Sharing with Remote Sensing Active current sharing is specified for HRPG-600-24, HRPG-600-36 and HRPG-600-48. Use no more than 4 units; output-voltage differences must be less than 2%. Consult the manufacturer for larger parallel arrangements. Maximum parallel current = rated current per unit × number of units × 0.9. Use short, large-diameter power wiring; connect corresponding main +V/−V outputs and mutually connect +S, −S, CS and GND as in the complete parallel diagram. Twist the remote load-sense pair. For four identical HRPG-600-24 units, the equation gives 97.2 A maximum and 2332.8 W at nominal output voltage before additional input/thermal derating. The cover’s “up to 2400 W (3+1)” does not override this equation or certify a fault-redundancy system. A minimum 2% dummy load is required. Below the stated 2% rated-load condition, only the master may operate; slave units may enter standby and their output LED and relay may remain off. Apply the catalog’s load condition rather than expecting balanced sharing down to zero load. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $355.35

  • HRPG-600-15

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-15

    MEAN WELL HRPG-600-15 is an enclosed AC/DC power supply rated 15 V, 43 A and 645 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-15 Model meaning HRPG-600 identifies the family and its nominal power class; 15 identifies the rated main-output voltage. Use the actual 645 W rating for this model. Rated main output 15 VDC / 43 A / 645 W Main current range 0 to 43 A, subject to the applicable load and derating conditions. Local voltage adjustment 13.5 to 18 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 18.8–21.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current-Sharing Applicability The family connector drawing includes CS, but the current-sharing function is explicitly limited to the 24 V, 36 V and 48 V versions. Do not use this 15 V model as a documented parallel current-sharing unit. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $355.35

  • HRPG-600-12

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-12

    MEAN WELL HRPG-600-12 is an enclosed AC/DC power supply rated 12 V, 53 A and 636 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-12 Model meaning HRPG-600 identifies the family and its nominal power class; 12 identifies the rated main-output voltage. Use the actual 636 W rating for this model. Rated main output 12 VDC / 53 A / 636 W Main current range 0 to 53 A, subject to the applicable load and derating conditions. Local voltage adjustment 10.2 to 13.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 14.4–16.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current-Sharing Applicability The family connector drawing includes CS, but the current-sharing function is explicitly limited to the 24 V, 36 V and 48 V versions. Do not use this 12 V model as a documented parallel current-sharing unit. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $363.24

  • HRPG-600-7.5

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-7.5

    MEAN WELL HRPG-600-7.5 is an enclosed AC/DC power supply rated 7.5 V, 80 A and 600 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-7.5 Model meaning HRPG-600 identifies the family and its nominal power class; 7.5 identifies the rated main-output voltage. Use the actual 600 W rating for this model. Rated main output 7.5 VDC / 80 A / 600 W Main current range 0 to 80 A, subject to the applicable load and derating conditions. Local voltage adjustment 6.8 to 9 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 86% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 9.4–10.9 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current-Sharing Applicability The family connector drawing includes CS, but the current-sharing function is explicitly limited to the 24 V, 36 V and 48 V versions. Do not use this 7.5 V model as a documented parallel current-sharing unit. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $355.35

  • HRPG-600-5

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-5

    MEAN WELL HRPG-600-5 is an enclosed AC/DC power supply rated 5 V, 120 A and 600 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-5 Model meaning HRPG-600 identifies the family and its nominal power class; 5 identifies the rated main-output voltage. Use the actual 600 W rating for this model. Rated main output 5 VDC / 120 A / 600 W Main current range 0 to 120 A, subject to the applicable load and derating conditions. Local voltage adjustment 4.3 to 5.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 82% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 6–7 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current-Sharing Applicability The family connector drawing includes CS, but the current-sharing function is explicitly limited to the 24 V, 36 V and 48 V versions. Do not use this 5 V model as a documented parallel current-sharing unit. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $363.24

  • HRPG-600-3.3

    MEAN WELL HRPG-600 series: single-output enclosed AC/DC power supply with active PFC - HRPG-600-3.3

    MEAN WELL HRPG-600-3.3 is an enclosed AC/DC power supply rated 3.3 V, 120 A and 396 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-600 Datasheet (PDF) The HRPG-600 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-600-3.3 Model meaning HRPG-600 identifies the family and its nominal power class; 3.3 identifies the rated main-output voltage. Use the actual 396 W rating for this model. Rated main output 3.3 VDC / 120 A / 396 W Main current range 0 to 120 A, subject to the applicable load and derating conditions. Local voltage adjustment 2.8 to 3.8 V using SVR1 Ripple and noise 120 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 78.5% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1000 ms at 230 VAC or 2500 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 3.96–4.62 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Apply any additional low-temperature standby condition below. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. In the shaded −40 to −20°C region, the 5 V standby output must have a minimum load of 0.03 A. Remote Sense and DC-OK Remote-sense terminals CN100 pin 9: +S; pin 10: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 7 is DC-OK; pin 6/8 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 3 relative to RC− pin 4: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 2 relative to AUXG pin 1: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.75 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Current-Sharing Applicability The family connector drawing includes CS, but the current-sharing function is explicitly limited to the 24 V, 36 V and 48 V versions. Do not use this 3.3 V model as a documented parallel current-sharing unit. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 AUXG — Isolated standby-output return CN100 pin 2 AUX — 5 V standby output CN100 pin 3 RC+ — Remote control positive CN100 pin 4 RC- — Remote control reference CN100 pin 5 CS — Current-share signal; applicable only to 24 V, 36 V and 48 V versions CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 DC-OK — DC output-status signal CN100 pin 8 GND — DC-OK / main-output reference CN100 pin 9 +S — Positive remote sense CN100 pin 10 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-10DP-2DS or equivalent Mating housing HRS DF11-10DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1142.5K hours, Telcordia SR-332 (Bellcore); 138.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.58 kg / 1580 g Published carton data 8 pieces / 13.6 kg / 1.34 CUFT Document HRPG-600-SPEC, 2024-10-30; combined HRP PDF pages 29, 30, 31, 32 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $363.24

  • HRP-600-48

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-48

    MEAN WELL HRP-600-48 is an enclosed AC/DC power supply rated 48 V, 13 A and 624 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-48 Model meaning HRP-600 identifies the family and its nominal power class; 48 identifies the rated main-output voltage. Use the actual 624 W rating for this model. Rated main output 48 VDC / 13 A / 624 W Main current range 0 to 13 A, subject to the applicable load and derating conditions. Local voltage adjustment 40.8 to 55.2 V using SVR1 Ripple and noise 240 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 57.6–67.2 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $319.86

  • HRP-600-36

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-36

    MEAN WELL HRP-600-36 is an enclosed AC/DC power supply rated 36 V, 17.5 A and 630 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-36 Model meaning HRP-600 identifies the family and its nominal power class; 36 identifies the rated main-output voltage. Use the actual 630 W rating for this model. Rated main output 36 VDC / 17.5 A / 630 W Main current range 0 to 17.5 A, subject to the applicable load and derating conditions. Local voltage adjustment 28.8 to 39.6 V using SVR1 Ripple and noise 200 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 41.4–48.6 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $297.19

  • HRP-600-24

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-24

    MEAN WELL HRP-600-24 is an enclosed AC/DC power supply rated 24 V, 27 A and 648 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-24 Model meaning HRP-600 identifies the family and its nominal power class; 24 identifies the rated main-output voltage. Use the actual 648 W rating for this model. Rated main output 24 VDC / 27 A / 648 W Main current range 0 to 27 A, subject to the applicable load and derating conditions. Local voltage adjustment 21.6 to 28.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 30–34.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $297.19

  • HRP-600-15

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-15

    MEAN WELL HRP-600-15 is an enclosed AC/DC power supply rated 15 V, 43 A and 645 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-15 Model meaning HRP-600 identifies the family and its nominal power class; 15 identifies the rated main-output voltage. Use the actual 645 W rating for this model. Rated main output 15 VDC / 43 A / 645 W Main current range 0 to 43 A, subject to the applicable load and derating conditions. Local voltage adjustment 13.5 to 18 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 18.8–21.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $297.19

  • HRP-600-12

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-12

    MEAN WELL HRP-600-12 is an enclosed AC/DC power supply rated 12 V, 53 A and 636 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-12 Model meaning HRP-600 identifies the family and its nominal power class; 12 identifies the rated main-output voltage. Use the actual 636 W rating for this model. Rated main output 12 VDC / 53 A / 636 W Main current range 0 to 53 A, subject to the applicable load and derating conditions. Local voltage adjustment 10.2 to 13.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 14.4–16.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $319.86

  • HRP-600-7.5

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-7.5

    MEAN WELL HRP-600-7.5 is an enclosed AC/DC power supply rated 7.5 V, 80 A and 600 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-7.5 Model meaning HRP-600 identifies the family and its nominal power class; 7.5 identifies the rated main-output voltage. Use the actual 600 W rating for this model. Rated main output 7.5 VDC / 80 A / 600 W Main current range 0 to 80 A, subject to the applicable load and derating conditions. Local voltage adjustment 6.8 to 9 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 86% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 9.4–10.9 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $319.86

  • HRP-600-5

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-5

    MEAN WELL HRP-600-5 is an enclosed AC/DC power supply rated 5 V, 120 A and 600 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-5 Model meaning HRP-600 identifies the family and its nominal power class; 5 identifies the rated main-output voltage. Use the actual 600 W rating for this model. Rated main output 5 VDC / 120 A / 600 W Main current range 0 to 120 A, subject to the applicable load and derating conditions. Local voltage adjustment 4.3 to 5.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 82% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 6–7 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $319.86

  • HRP-600-3.3

    MEAN WELL HRP-600 series: single-output enclosed AC/DC power supply with active PFC - HRP-600-3.3

    MEAN WELL HRP-600-3.3 is an enclosed AC/DC power supply rated 3.3 V, 120 A and 396 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRP-600 Datasheet (PDF) The HRP-600 section is on PDF pages 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRP-600-3.3 Model meaning HRP-600 identifies the family and its nominal power class; 3.3 identifies the rated main-output voltage. Use the actual 396 W rating for this model. Rated main output 3.3 VDC / 120 A / 396 W Main current range 0 to 120 A, subject to the applicable load and derating conditions. Local voltage adjustment 2.8 to 3.8 V using SVR1 Ripple and noise 120 mVp-p maximum Accuracy and regulation Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Typical efficiency 78.5% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.93 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 7.6 A at 115 VAC; 3.6 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.2 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 50 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 3.96–4.62 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 35 ±15%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from input/fan end toward output end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 3: +S; pin 4: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 1 is DC-OK; pin 2 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. Remote sensing is built in. These HRP-600 pages do not specify a maximum line-drop compensation value; do not import another family’s limit. Use GND as the DC-OK reference. No signal-current or isolation rating is specified in these two pages. Function Configuration This HRP model provides remote sense and DC-OK. Remote ON/OFF, a 5 V standby output and active current-sharing operation are not specified for this HRP variant; do not treat features of HRPG models as fitted here. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 DC-OK — DC output-status signal CN100 pin 2 GND — DC-OK / main-output reference CN100 pin 3 +S — Positive remote sense CN100 pin 4 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-4DP-2DS or equivalent Mating housing HRS DF11-4DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 63.5 mm (L × W × H); case 977A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=6 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 38.3 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1333.6K hours, Telcordia SR-332 (Bellcore); 140.7K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. The cover specifies use of 105°C long-life electrolytic capacitors. This is a component rating, not the allowable ambient temperature. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.5 kg / 1500 g Published carton data 8 pieces / 13 kg / 1.34 CUFT Document HRP-600-SPEC, 2026-04-03; combined HRP PDF pages 27, 28 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $327.75

  • HRPG-450-48

    MEAN WELL HRPG-450 series: single-output enclosed AC/DC power supply with active PFC - HRPG-450-48

    MEAN WELL HRPG-450-48 is an enclosed AC/DC power supply rated 48 V, 9.5 A and 456 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-450 Datasheet (PDF) The HRPG-450 section is on PDF pages 24, 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-450-48 Model meaning HRPG-450 identifies the family and its nominal power class; 48 identifies the rated main-output voltage. Use the actual 456 W rating for this model. Rated main output 48 VDC / 9.5 A / 456 W Main current range 0 to 9.5 A, subject to the applicable load and derating conditions. Local voltage adjustment 40.8 to 55.2 V using SVR1 Ripple and noise 240 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89.5% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.95 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.5 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 100 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 57.6–67.2 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 20 ±10%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from output end toward input/fan end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 7: +S; pin 8: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 5 is DC-OK; pin 6 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 1 relative to RC− pin 2: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 3 relative to AUXG pin 4: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.5 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Function Scope No active current-sharing mode is specified for HRPG-450 in this catalog section. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 RC+ — Remote control positive CN100 pin 2 RC- — Remote control reference CN100 pin 3 AUX — 5 V standby output CN100 pin 4 AUXG — Isolated standby-output return CN100 pin 5 DC-OK — DC output-status signal CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 +S — Positive remote sense CN100 pin 8 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-8DP-2DS or equivalent Mating housing HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 41 mm (L × W × H); case 995A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=5 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 18 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1180.3K hours, Telcordia SR-332 (Bellcore); 130.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.19 kg / 1190 g Published carton data 12 pieces / 15.3 kg / 0.81 CUFT Document HRPG-450-SPEC, 2025-12-05; combined HRP PDF pages 24, 25, 26 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $337.61

  • HRPG-450-36

    MEAN WELL HRPG-450 series: single-output enclosed AC/DC power supply with active PFC - HRPG-450-36

    MEAN WELL HRPG-450-36 is an enclosed AC/DC power supply rated 36 V, 12.5 A and 450 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-450 Datasheet (PDF) The HRPG-450 section is on PDF pages 24, 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-450-36 Model meaning HRPG-450 identifies the family and its nominal power class; 36 identifies the rated main-output voltage. Use the actual 450 W rating for this model. Rated main output 36 VDC / 12.5 A / 450 W Main current range 0 to 12.5 A, subject to the applicable load and derating conditions. Local voltage adjustment 28.8 to 39.6 V using SVR1 Ripple and noise 240 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.95 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.5 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 100 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 41.4–48.6 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 20 ±10%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from output end toward input/fan end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 7: +S; pin 8: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 5 is DC-OK; pin 6 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 1 relative to RC− pin 2: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 3 relative to AUXG pin 4: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.5 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Function Scope No active current-sharing mode is specified for HRPG-450 in this catalog section. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 RC+ — Remote control positive CN100 pin 2 RC- — Remote control reference CN100 pin 3 AUX — 5 V standby output CN100 pin 4 AUXG — Isolated standby-output return CN100 pin 5 DC-OK — DC output-status signal CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 +S — Positive remote sense CN100 pin 8 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-8DP-2DS or equivalent Mating housing HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 41 mm (L × W × H); case 995A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=5 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 18 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1180.3K hours, Telcordia SR-332 (Bellcore); 130.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.19 kg / 1190 g Published carton data 12 pieces / 15.3 kg / 0.81 CUFT Document HRPG-450-SPEC, 2025-12-05; combined HRP PDF pages 24, 25, 26 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $337.61

  • HRPG-450-24

    MEAN WELL HRPG-450 series: single-output enclosed AC/DC power supply with active PFC - HRPG-450-24

    MEAN WELL HRPG-450-24 is an enclosed AC/DC power supply rated 24 V, 18.8 A and 451.2 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-450 Datasheet (PDF) The HRPG-450 section is on PDF pages 24, 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-450-24 Model meaning HRPG-450 identifies the family and its nominal power class; 24 identifies the rated main-output voltage. Use the actual 451.2 W rating for this model. Rated main output 24 VDC / 18.8 A / 451.2 W Main current range 0 to 18.8 A, subject to the applicable load and derating conditions. Local voltage adjustment 21.6 to 28.8 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Typical efficiency 88% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.95 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.5 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 100 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 30–34.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 20 ±10%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from output end toward input/fan end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 7: +S; pin 8: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 5 is DC-OK; pin 6 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 1 relative to RC− pin 2: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 3 relative to AUXG pin 4: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.5 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Function Scope No active current-sharing mode is specified for HRPG-450 in this catalog section. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 RC+ — Remote control positive CN100 pin 2 RC- — Remote control reference CN100 pin 3 AUX — 5 V standby output CN100 pin 4 AUXG — Isolated standby-output return CN100 pin 5 DC-OK — DC output-status signal CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 +S — Positive remote sense CN100 pin 8 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-8DP-2DS or equivalent Mating housing HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 41 mm (L × W × H); case 995A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=5 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 18 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1180.3K hours, Telcordia SR-332 (Bellcore); 130.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.19 kg / 1190 g Published carton data 12 pieces / 15.3 kg / 0.81 CUFT Document HRPG-450-SPEC, 2025-12-05; combined HRP PDF pages 24, 25, 26 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.

    $345.49

  • HRPG-450-15

    MEAN WELL HRPG-450 series: single-output enclosed AC/DC power supply with active PFC - HRPG-450-15

    MEAN WELL HRPG-450-15 is an enclosed AC/DC power supply rated 15 V, 30 A and 450 W at its main output. It accepts 85–264 VAC or 120–370 VDC and includes active PFC, fan cooling, remote sensing and DC-OK. Remote ON/OFF and an isolated 5 V, 0.3 A standby output are included. Apply the input, temperature and wiring limits for this exact model. Product Datasheet Download MEAN WELL HRPG-450 Datasheet (PDF) The HRPG-450 section is on PDF pages 24, 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model HRPG-450-15 Model meaning HRPG-450 identifies the family and its nominal power class; 15 identifies the rated main-output voltage. Use the actual 450 W rating for this model. Rated main output 15 VDC / 30 A / 450 W Main current range 0 to 30 A, subject to the applicable load and derating conditions. Local voltage adjustment 13.5 to 18 V using SVR1 Ripple and noise 150 mVp-p maximum Accuracy and regulation Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Typical efficiency 89% Unqualified data use 230 VAC input, rated load and 25°C ambient. Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Input and Timing Continuous input 85–264 VAC, 47–63 Hz, or 120–370 VDC; universal full-range AC input with low-line derating. Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous AC input rating. Typical power factor >0.95 at 230 VAC; >0.99 at 115 VAC, at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Typical inrush / leakage 35 A at 115 VAC; 70 A at 230 VAC. Leakage <1.5 mA at 240 VAC. Setup / rise time Setup 1800 ms at 230 VAC or 3600 ms at 115 VAC; rise 100 ms, at full load. Typical hold-up time 16 ms at either 230 VAC or 115 VAC, at full load. The block diagram includes active PFC and active inrush-current limiting; PWM switching frequency is 70 kHz. Setup time is measured at the first cold start. Repeated ON/OFF operation can increase setup time. Protection Short circuit / overload 105–135% of rated output power. Constant-current limiting with automatic recovery after the fault is removed. Overvoltage 18.8–21.8 V. Output shuts down; re-power to recover. Overtemperature Output shuts down and recovers automatically after temperature decreases. Protection thresholds are not continuous overload operating ratings. Cooling, Derating and Environment Fan control, typical Built-in fan turns on at the printed load threshold of 20 ±10%, or when internal sensor RTH2 reaches at least 50°C. RTH2 temperature is not ambient temperature. Horizontal temperature curve 100% load from −40°C to +50°C, then derating to 50% at +70°C. Input-voltage curve At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; full load from 100 to 264 VAC. Humidity / storage Working: 20–90% RH. Storage: −40 to +85°C and 10–95% RH. Non-condensing. Temperature coefficient / vibration ±0.03%/°C from 0 to 50°C; 10–500 Hz, 5 G, 10 minutes/cycle, 60 minutes each on X, Y and Z axes. Forced-air cooling: airflow runs from output end toward input/fan end, as shown in the mechanical drawing. Keep this airflow path clear. Above 2000 m, the fan-cooled altitude note requires ambient-temperature derating of 5°C per additional 1000 m. This note does not specify a separate maximum altitude. Remote Sense and DC-OK Remote-sense terminals CN100 pin 7: +S; pin 8: −S. Connect to the corresponding positive and negative load points; use main terminals for load current. DC-OK status CN100 pin 5 is DC-OK; pin 6 is GND. The signal is 3.3–5.6 V when the PSU is ON and 0–1 V when OFF. The sense pair compensates up to 0.5 V of drop in the load wiring. Twist +S and −S together to reduce noise pickup. DC-OK is a TTL-level signal referenced to GND, which connects to the main negative output. No DC-OK current-drive rating is specified in this section. Remote ON/OFF and Standby Output Remote-control connection CN100 RC+ pin 1 relative to RC− pin 2: open or 4–10 V = main output ON; short or 0–0.8 V = main output OFF. Standby output CN100 AUX pin 3 relative to AUXG pin 4: 5 V nominal, 4.75–5.25 V (±5%), 0.3 A maximum; ripple 50 mVp-p maximum. Remote-off no-load consumption <0.5 W when RC+ and RC− are shorted or held at 0–0.8 V. The standby output is not controlled by remote ON/OFF. AUXG is isolated from the main +V/−V output; keep it distinct from the main-output GND reference. The remote-control terminal ratings and polarity apply to this model. They do not establish that a control cable or factory jumper is included. Function Scope No active current-sharing mode is specified for HRPG-450 in this catalog section. Power Terminals and CN100 AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG / protective earth. DC output terminals 1–3 = −V; 4–6 = +V. CN100 pin 1 RC+ — Remote control positive CN100 pin 2 RC- — Remote control reference CN100 pin 3 AUX — 5 V standby output CN100 pin 4 AUXG — Isolated standby-output return CN100 pin 5 DC-OK — DC output-status signal CN100 pin 6 GND — DC-OK / main-output reference CN100 pin 7 +S — Positive remote sense CN100 pin 8 -S — Negative remote sense Follow the numbered mechanical view when wiring. Keep protective earth, live AC, main DC, standby return and low-level signals separate as applicable; connector numbering is not interchangeable between HRP and HRPG. Connectors and Installation CN100 onboard connector HRS DF11-8DP-2DS or equivalent Mating housing HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent; ** is an unresolved suffix in the printed catalog. Body / case 218 × 105 × 41 mm (L × W × H); case 995A; general drawing tolerance ±1 mm. Mounting holes Base: 4-M4, L=5 mm; centre spacing 152.4 × 63.5 mm. Both sides: 8-M4 total, L=4 mm. Side-hole layout Longitudinal spacing 152.4 mm; vertical spacing 18 mm; lower-row height 12.5 mm. The drawing shows 32.8 mm and 20.75 mm edge offsets for the base pattern. Terminal projections Input side: 12 mm maximum; output side: 18 mm maximum, beyond the 218 mm body. Terminal layout details AC terminal drawing marks 8.2 mm and 10 mm; DC terminal drawing marks 11 mm and 9.2 mm. Follow the drawing for their exact locations. The mounting L values limit screw penetration into the enclosure, not total screw length. Allow for mounting-surface thickness. No mounting or power-terminal tightening torque is stated in this section. Use the full drawing for orientation and installation envelope. The output-end drawing identifies LED and output-adjustment SVR1; no LED colour or additional diagnostic behaviour is specified. The listed mating parts are selection references, not a declaration that housings, contacts, cables or screws are supplied. Confirm the complete wire-compatible contact suffix before ordering; this section gives no dedicated bracket or cable-kit order code. Safety, EMC and Reliability Listed approvals UL62368-1; TUV BS EN/EN62368-1; EAC TP TC004 Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input–output, input–FG and output–FG. EMC emission BS EN/EN55032(CISPR32) Class B; BS EN/EN61000-3-2,-3; EAC TP TC020 EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55024; BS EN/EN61000-6-2; heavy industry; EAC TP TC020 Minimum MTBF 1180.3K hours, Telcordia SR-332 (Bellcore); 130.5K hours, MIL-HDBK-217F at 25°C. The PSU is a component for final equipment. EMC testing used a 360 × 360 × 1 mm metal plate; the completed equipment must be checked again for EMC compliance. Component approvals do not automatically certify the finished installation. The manufacturer datasheet lists a 5-year warranty, subject to the applicable manufacturer terms. MTBF is a prediction, not a guaranteed lifetime. Weight and Catalogue Reference Catalogue PACKING reference per unit 1.19 kg / 1190 g Published carton data 12 pieces / 15.3 kg / 0.81 CUFT Document HRPG-450-SPEC, 2025-12-05; combined HRP PDF pages 24, 25, 26 The per-unit packing reference is not a measured net weight or shipment weight. Do not enter the carton total as an individual product weight.