MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000H-T
DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 60 ~ 420VDC AC output power rating (Typ.):4500 ~ 4600VA (for input 60 ~ 420VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):460X211X83.5 DC input connector: terminal block Product Features 1. DC/AC AC grid-connected energy recovery inverter. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV operation mode can be flexibly selected. 5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERG-5000 communications can be connected. 7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$13,524.43
-
MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000H
DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 60 ~ 420VDC AC output power rating (Typ.):4500 ~ 4600VA (for input 60 ~ 420VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):504X211X83.5 DC Input Connector: NEWSOK Product Features 1. DC/AC AC grid-connected energy recovery inverter. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV operation mode can be flexibly selected. 5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERG-5000 communications can be connected. 7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$13,524.43
-
MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000-T
DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 10 ~ 60VDC AC output power rating (Typ.):2600 ~ 4320VA (for input 10 ~ 12VDC),4320 ~ 4400VA (for input 12 ~ 60VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):460X211X83.5 DC input connector: terminal block Product Features 1. DC/AC AC grid-connected energy recovery inverter. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV operation mode can be flexibly selected. 5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERG-5000 communications can be connected. 7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$13,524.43
-
MEAN WELL ERG Series: Energy Recovery Grid Type Inverter - ERG-5000
DC input power rating (Typ.):5000W(1250W * 4CH) DC input maximum power (Typ.):6000W(1500W * 4CH) DC input voltage range: 10 ~ 60VDC AC output power rating (Typ.):2600 ~ 4320VA (for input 10 ~ 12VDC),4320 ~ 4400VA (for input 12 ~ 60VDC) AC output voltage range: 180~264±5VAC, single phase AC output maximum current (Typ.):24A/230VAC Size (mm):504X211X83.5 DC Input Connector: NEWSOK Product Features 1. DC/AC AC grid-connected energy recovery inverter. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 420VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV operation mode can be flexibly selected. 5. Built-in CANBus ventilation interface, and can be matched with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERG-5000 communications can be connected. 7. Protection: overvoltage/undervoltage/over temperature/over power/grid failure/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$13,524.43
-
MEAN WELL ERS Series: Energy Recovery DC Power Supplies - ERS-1400H
DC input rated power (Typ.):864~1440W (for input 60 ~ 100VDC),1440W (for input 100 ~ 380VDC) DC input voltage range: 60 ~ 380VDC DC output voltage: 320VDC DC output current (maximum):0 ~ 6.3A AC input voltage range: 180 ~ 264VAC Size (mm):450X213X63.5 Product Features 1. AC/DC DC energy recovery system power supply. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 380VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV/CP operation mode can be flexibly selected. 5. Built-in CANBus communication interface, and can be used with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERS-1400 communication can be connected. 7. Protection: overvoltage/undervoltage/overtemperature/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$4,501.29
-
MEAN WELL ERS Series: Energy Recovery DC Power Supplies - ERS-1400
DC input power rating (Typ.):1200~1400W (for input 10 ~ 12VDC),1440W (for input 12 ~ 60VDC) DC input voltage range: 10 ~ 60VDC DC output voltage: 320VDC DC output current (maximum):0 ~ 6.3A AC input voltage range: 180 ~ 264VAC Size (mm):450X213X63.5 Product Features 1. AC/DC DC energy recovery system power supply. 2. Wide input voltage range: 10 ~ 60VDC/60 ~ 380VDC (depending on the model). 3. Modular design, flexible configuration of aging test can be grouped or partitioned. 4. CC/CV/CP operation mode can be flexibly selected. 5. Built-in CANBus communication interface, and can be used with CMU2A for remote monitoring, setting, data analysis and management. 6. Up to 64 ERS-1400 communication can be connected. 7. Protection: overvoltage/undervoltage/overtemperature/communication failure. 8. Aging test system, energy saving and carbon reduction, excellent weapon to save electricity bill, 3-year warranty.
$4,501.29