MEAN WELL IRM-02-12S is a SMD surface-mount encapsulated AC/DC power module rated at 12 V, 167 mA and 2 W. Its universal input accepts 85–305 VAC or 120–430 VDC. The silicone-potted phenolic enclosure, Class II construction with no FG pin and free-air convection cooling suit PCB integration in industrial and electronic equipment. Observe the input, temperature and installation limits below.
Product Datasheet
Download MEAN WELL IRM-02 Datasheet (PDF)
The IRM-02 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation.
Model and Mounting Configuration
Exact model
IRM-02-12S.
Installation style
SMD surface mount. The S suffix identifies the SMD configuration.
Construction
Phenolic enclosure with silicone potting to support heat dissipation, vibration resistance and basic resistance to dust and moisture.
Typical applications
Industrial electrical equipment, mechanical equipment, factory automation and handheld electronic devices.
This is an encapsulated industrial AC/DC power module for integration on an equipment PCB. Its mounting style, pin assignments and soldering limits must match the selected model. The enclosure description does not specify an IP rating.
Model-Specific DC Output
DC output voltage
12 V.
Rated current
167 mA (0.167 A).
Current range
0–167 mA.
Rated output power
2 W, as printed for this exact model.
Ripple and noise, maximum
150 mVp-p.
Voltage tolerance
±2.5%; includes set-up tolerance, line regulation and load regulation.
Line regulation
±0.5%.
Load regulation
±0.5%.
Efficiency, typical
74%.
Unless stated otherwise, parameters are measured at 230 VAC, rated load and 25°C ambient. The rated power and current preserve the catalogue’s printed precision.
Ripple and noise are measured at 20 MHz bandwidth using a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel.
Input and Start-Up
AC input range
85–305 VAC; universal full-range input, subject to low-input derating.
DC input range
120–430 VDC.
AC frequency
47–63 Hz.
Input current, typical
45 mA at 115 VAC; 30 mA at 230 VAC; 25 mA at 277 VAC.
Inrush current, typical
5 A at 115 VAC; 10 A at 230 VAC.
No-load input power
Less than 0.075 W.
Set-up and rise time
600 ms set-up and 30 ms rise, at both 230 VAC and 115 VAC, full load.
Hold-up time, typical
40 ms at 230 VAC; 12 ms at 115 VAC, full load.
Leakage current
Less than 0.25 mA at 277 VAC.
Switching-frequency reference
130 kHz in the block diagram.
Protection
Short circuit and overload
Short-circuit protection is listed. Overload threshold: ≥110% of rated output power; hiccup mode automatically recovers after the fault is removed.
Overvoltage threshold
12.6–16.2 V.
Overvoltage action
Output voltage shuts off, with clamping by a zener diode.
Protection thresholds are not additional continuous or peak output ratings. Operate within the model-specific current and power ratings and the applicable derating curves.
Cooling, Derating and Environment
Cooling
Free-air convection.
Working ambient range
−30 to +85°C, subject to the load-derating curve.
Horizontal temperature/load curve
100% load from −30 to +70°C, reducing to 60% at +85°C.
Input-voltage/load curve
At 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC; 100% plateau through 305 VAC.
Operating humidity
20–90% RH, non-condensing.
Storage conditions
−40 to +100°C; 10–95% RH.
Temperature coefficient
±0.03%/°C from 0 to 75°C.
Vibration
10–500 Hz, 5 G, 10 minutes per cycle; 60 minutes each along X, Y and Z.
High-altitude thermal note
For fanless models operating above 2,000 m, the catalogue specifies an ambient-temperature reduction of 3.5°C per additional 1,000 m. This thermal note does not extend the separately stated OVC II altitude rating.
Apply temperature and input-voltage restrictions together, using the full curves for intermediate conditions. The upper working temperature is a derated operating point, not a full-power claim.
Dimensions, Pin Assignments and Soldering
Dimensions, L × W × H
33.7 × 22.2 × 16 mm.
Case and drawing units
Case No. IRM02; dimensions in millimetres, general tolerance ±0.5 mm unless otherwise indicated.
SMD pin assignments
Pin 1: AC/L; Pin 24: AC/N; Pin 13: −Vo; Pin 12: +Vo; Other terminals: NC.
View and footprint orientation
The module pin-number drawing is a bottom view; the recommended PCB landing pattern is a top view. Preserve these separate orientations when laying out the PCB.
Lead and land dimensions
Lead pitch 2.54 mm; land dimensions 1.5 × 2.54 mm; paired adjacent leads are marked 1.0 mm apart. Across-lead width 27.3 mm; lead width 0.45 mm, thickness 0.3 mm and foot length 1.5 mm.
Recommended PCB layout references
The top-view landing pattern marks 28.5 mm and 26.47 mm across its two pad rows, a 2.03 mm edge reference and 2.54 mm lead pitch. Use the complete numbered drawing for the populated and unpopulated positions.
Hot-air reflow limits
Peak 240°C for 10 seconds maximum; total time above 220°C no more than 60 seconds. The published reflow profile applies only to hot-air reflow soldering.
Other soldering limits
Wave soldering: 265°C for 5 seconds maximum; manual soldering: 390°C for 3 seconds maximum.
Mounting and accessory selection
Use the matching manufacturer footprint and installation instructions. The assigned catalogue pages specify no separate orderable connector, mounting kit or accessory code for this model.
The case drawing and the recommended board layout use different views where indicated. Do not mirror input and output connections or treat NC positions as usable electrical terminals. Case references and dimension callouts are not separate accessory ordering codes.
Safety and EMC
Safety standards listed as approved
IEC62368-1; IEC61558-1/-2-16; UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1/-2-16; EAC TP TC004; BSMI CNS15598-1.
Protection class and limited power
Class II construction, with no FG pin. LPS is identified on the catalogue feature page.
Overvoltage category and altitude
OVC II up to 2,000 m under IEC/EN61558-1/-2-16 and IEC/EN/UL62368-1.
Input-to-output withstand voltage
4.2 kVAC.
Input-to-output insulation resistance
100 MΩ at 500 VDC, 25°C and 70% RH.
Emissions compliance
BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020; CNS15936 Class B.
Immunity compliance
BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; EAC TP TC020. Heavy-industry level is stated, with line-to-neutral surge 1 kV.
Built-in EMI filtering is specified to meet BS EN/EN55032 Class B without additional components. Confirm the final assembled equipment’s applicable safety and EMC requirements; component-level compliance does not by itself certify the complete system.
Weight, Reliability and Catalogue
Single-unit catalogue weight
24 g (0.024 kg), explicitly stated in PACKING for this mounting style; a catalogue reference rather than a measured parcel weight.
Packing reference
640 pieces / 16.3 kg / 0.84 CUFT.
Minimum MTBF estimates
13571.4 thousand hours by Telcordia SR-332 (Bellcore); 1960.2 thousand hours by MIL-HDBK-217F at 25°C.
Catalogue warranty
3-year manufacturer warranty, subject to the applicable terms.
Applicable specification
IRM-02-SPEC, 2025-11-21; combined PDF pages 5–8. Operating values and mounting details apply to the exact suffix shown above.
MTBF is a statistical reliability estimate, not a guaranteed service-life duration.
Read