LPS , ELP , LPP: Single Output Switching Power Supply , Single Output Switching Power Supply without PFC Function , Single Output Switching Power Supply with PFC Function

46 products

MEAN WELL LPS / LPP / ELP Series Single Output Switching Power Supply

  • Product Features
  • General Specifications
  • Series Comparison

Product Features

  • Global Input: Supports universal AC input range (90-264VAC).
  • Low Profile: Compact 1U low-profile designs (heights as low as 23mm-33mm).
  • Performance: Built-in active PFC function (on LPP/ELP series) for power factor correction.
  • Reliability: 100% full-load burn-in tested; short-circuit, overload, and overvoltage protections.
  • Cooling: Excellent thermal design for natural convection operation.
  • Longevity: 3-year warranty with high MTBF ratings.
  • Compliance: Global safety standards (UL/EN/IEC62368-1) and EMC compliance for industrial applications.

General Specifications

Item Specification Detail
Input Voltage Range 90-264VAC or 127-370VDC
Operating Temperature -20°C to +70°C (Refer to derating)
Isolation Voltage I/P-O/P: 3KVAC, I/P-FG: 2KVAC
Safety Standards UL62368-1, TUV EN/IEC 62368-1
EMC Emissions Compliance to EN55032 (CISPR32) Class B
Altitude Up to 2000m (operating)

Series Power & Footprint

Series Power Range Key Attribute
LPS-50/75/100 50W-100W Compact, 23mm-32mm height
ELP-75 75W High efficiency with active PFC
LPP-100/150 100W-150W Industrial grade, active PFC
Note: Typical efficiency ranges between 75% and 91% depending on the specific model and output voltage. Please consult the specific product datasheet for exact ripple, noise, and derating curves.
  • LPP-150-48

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-48

    MEAN WELL LPP-150-48 is a single-output open-frame AC/DC power supply with active PFC. Its 48 V output is rated at 3.2 A / 153.6 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-48. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 48 VDC. Rated current 3.2 A with the specified cooling. Current range 0–3.2 A, subject to the applicable load limit. Rated power 153.6 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 2.56 A / 122.88 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 250 mVp-p. Voltage adjustment 45.6–52.8 V using +V ADJ. Voltage tolerance ±1.0%. Line regulation ±0.5%. Load regulation ±0.5%. Typical efficiency 85%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 52.8–64.8 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-27

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-27

    MEAN WELL LPP-150-27 is a single-output open-frame AC/DC power supply with active PFC. Its 27 V output is rated at 5.6 A / 151.2 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-27. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 27 VDC. Rated current 5.6 A with the specified cooling. Current range 0–5.6 A, subject to the applicable load limit. Rated power 151.2 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 4.48 A / 120.96 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 150 mVp-p. Voltage adjustment 25.7–29.7 V using +V ADJ. Voltage tolerance ±1.0%. Line regulation ±0.5%. Load regulation ±0.5%. Typical efficiency 85%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 29.7–36.5 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-24

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-24

    MEAN WELL LPP-150-24 is a single-output open-frame AC/DC power supply with active PFC. Its 24 V output is rated at 6.3 A / 151.2 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-24. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 24 VDC. Rated current 6.3 A with the specified cooling. Current range 0–6.3 A, subject to the applicable load limit. Rated power 151.2 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 5.04 A / 120.96 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 150 mVp-p. Voltage adjustment 22.8–26.4 V using +V ADJ. Voltage tolerance ±1.0%. Line regulation ±0.5%. Load regulation ±0.5%. Typical efficiency 85%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 26.4–32.4 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-15

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-15

    MEAN WELL LPP-150-15 is a single-output open-frame AC/DC power supply with active PFC. Its 15 V output is rated at 10 A / 150 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-15. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 15 VDC. Rated current 10 A with the specified cooling. Current range 0–10 A, subject to the applicable load limit. Rated power 150 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 8 A / 120 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 14.3–16.5 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 83%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 16.5–20.25 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-13.5

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-13.5

    MEAN WELL LPP-150-13.5 is a single-output open-frame AC/DC power supply with active PFC. Its 13.5 V output is rated at 11.2 A / 151.2 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-13.5. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 13.5 VDC. Rated current 11.2 A with the specified cooling. Current range 0–11.2 A, subject to the applicable load limit. Rated power 151.2 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 8.96 A / 120.96 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 12.8–14.9 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 83%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 14.85–18.2 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-12

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-12

    MEAN WELL LPP-150-12 is a single-output open-frame AC/DC power supply with active PFC. Its 12 V output is rated at 12.5 A / 150 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-12. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 12 VDC. Rated current 12.5 A with the specified cooling. Current range 0–12.5 A, subject to the applicable load limit. Rated power 150 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 10 A / 120 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 11.4–13.2 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 82%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 13.2–16.2 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-7.5

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-7.5

    MEAN WELL LPP-150-7.5 is a single-output open-frame AC/DC power supply with active PFC. Its 7.5 V output is rated at 20 A / 150 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-7.5. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 7.5 VDC. Rated current 20 A with the specified cooling. Current range 0–20 A, subject to the applicable load limit. Rated power 150 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 16 A / 120 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 7.13–8.25 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 80%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 8.25–10.1 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For this 3.3–7.5 V model group below 100 VAC input with no fan, reduce the load to no more than 60% of the rated output. This additional low-input restriction applies together with the temperature curve. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-5

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-5

    MEAN WELL LPP-150-5 is a single-output open-frame AC/DC power supply with active PFC. Its 5 V output is rated at 30 A / 150 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-5. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 5 VDC. Rated current 30 A with the specified cooling. Current range 0–30 A, subject to the applicable load limit. Rated power 150 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 24 A / 120 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 4.75–5.5 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 76%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 5.5–6.75 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For this 3.3–7.5 V model group below 100 VAC input with no fan, reduce the load to no more than 60% of the rated output. This additional low-input restriction applies together with the temperature curve. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-150-3.3

    MEAN WELL LPP-150 series: Open-Frame AC/DC Power Supply with PFC - LPP-150-3.3

    MEAN WELL LPP-150-3.3 is a single-output open-frame AC/DC power supply with active PFC. Its 3.3 V output is rated at 30 A / 99 W under the specified 18 CFM cooling condition. Natural-convection operation uses a lower load limit, with additional temperature and low-input restrictions below. Product Datasheet Download MEAN WELL LPP-150 Datasheet (PDF) The LPP-150 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Cooling Selection Complete model LPP-150-3.3. Series LPP-150 single-output switching power supply with active PFC. Rated cooling condition 18 CFM forced airflow; apply the temperature and input-voltage curves. Natural convection Permitted at the reduced load shown in the no-fan curve. Optional protection Overtemperature protection is optional; confirm the required configuration before ordering. The catalogue specifies 100% full-load burn-in testing and a three-year manufacturer warranty. Use the complete model and required options when selecting the supply. Output Specifications Nominal output 3.3 VDC. Rated current 30 A with the specified cooling. Current range 0–30 A, subject to the applicable load limit. Rated power 99 W with 18 CFM airflow at full-rating conditions. Natural-convection limit through 40°C 24 A / 79.2 W, calculated from the 80% curve; low-input and other thermal restrictions still apply. Maximum ripple and noise 100 mVp-p. Voltage adjustment 3.14–3.63 V using +V ADJ. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. Typical efficiency 70%. Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise is measured with 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 μF and 47 μF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Input and Timing Input range 85–264 VAC or 120–370 VDC. AC frequency 47–63 Hz. Power factor at full load At least 0.96 at 230 VAC and at least 0.97 at 115 VAC. Typical AC input current 2.5 A at 115 VAC; 1.2 A at 230 VAC. Typical cold-start inrush 55 A at 230 VAC. Leakage current Less than 3.5 mA at 240 VAC. Setup / rise time 600 ms / 30 ms at full load. Typical hold-up time 30 ms at full load. Switching frequencies PFC: 67 kHz; PWM: 134 kHz. At 60 Hz, the input-voltage curve allows 80% load at 85 VAC, increasing to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply the lower of the input and cooling limits. Protection Short circuit and overload 105–150% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Overvoltage threshold 3.63–4.45 V. Overvoltage recovery Output shuts down; re-power on to recover. Overtemperature option Available as an option. Confirm its inclusion for the ordered configuration; the catalogue does not state a trip temperature or recovery condition. Environment and Derating Operating humidity 20–90% RH, non-condensing. Storage temperature and humidity −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. For horizontal installation with 18 CFM airflow, allowable load is 80% at −10°C, rises to 100% at 0°C, remains at 100% through 50°C and decreases to 80% at 60°C. The fan-cooled operating range is −10 to +60°C. With no fan, the curve allows 80% load from −10 to +40°C, then decreases to 60% at +50°C. The no-fan curve ends at 50°C; do not apply the fan-cooled 60°C endpoint to natural convection. For this 3.3–7.5 V model group below 100 VAC input with no fan, reduce the load to no more than 60% of the rated output. This additional low-input restriction applies together with the temperature curve. For installation above 2000 m, reduce the permitted ambient temperature by 3.5°C per additional 1000 m without a fan, or by 5°C per additional 1000 m with fan cooling. Confirm the installation requirements for the intended altitude. Mechanical Installation Overall dimensions (L × W × H) 222 × 75 × 41 mm. Drawing tolerance ±1 mm. Mounting holes Four Ø3.8 mm holes, 212 × 65 mm centres, with 5 mm edge offsets. Underside reference 3 mm maximum projection below the board; allow the required clearance. Forced-air arrangement The drawing shows an external 18 CFM fan 15 cm from the long side, with a 111 mm lateral alignment reference. Follow the illustrated airflow direction. Grounding Grounding is required. CN1 pin 5 is the safety-ground connection; connect the marked grounding points as shown. Input fuse marking AC F5A/250V, as marked in the mechanical drawing. The cooling illustration does not specify a fan order code or confirm that a fan is supplied. Use the complete mechanical drawing on PDF page 12 for mounting, polarity and +V ADJ. access. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent: pin 1 AC/L, pins 2 and 4 no pin, pin 3 AC/N, pin 5 FG / safety ground. DC output CN2 Two JST B6P-VH connectors or equivalent, shown as B6P-VH × 2: pins 1–6 are −V; pins 7–12 are +V. Mating housings and contacts Both connector groups list JST VHR housing-family references and JST SVH-21T-P1.1 terminals, or equivalents. Select the complete VHR housing reference to match the required circuit count and wire assembly. The catalogue does not identify a separate cover, mounting-bracket or cable-kit order code; do not assume an unlisted kit or loose mating parts are included. Safety and Electromagnetic Compatibility Safety approvals UL62368-1 and TUV BS EN/EN62368-1; EAC TP TC004. Withstand voltage Input–output: 3 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. The supply is an installation component; re-confirm safety and EMC compliance in the finished equipment with its actual mounting and wiring. Weight, Reliability and Catalogue Single-unit catalogue reference weight 620 g (0.62 kg), from the explicit per-unit PACKING value; a catalogue reference, not a measured net or shipping-parcel weight. Packing reference 24 pieces / 16.6 kg / 1.63 CUFT. MTBF, minimum estimates 2635.3 thousand hours, Telcordia SR-332 (Bellcore); 292.7 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty Three years, subject to applicable terms. Catalogue LPP-150-SPEC, 2024-10-30; combined PDF pages 11–12.

  • LPP-100-48

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-48

    MEAN WELL LPP-100-48 is a single-output, open-frame AC/DC power supply rated 48 V, 2.1 A and 100.8 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-48. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 48 VDC. Catalogue-rated output 2.1 A / 100.8 W. Continuous current range 0–2.1 A. Ripple and noise, maximum 250 mVp-p. Voltage adjustment 45.6–52.8 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 83%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 55.2–64.8 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-27

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-27

    MEAN WELL LPP-100-27 is a single-output, open-frame AC/DC power supply rated 27 V, 3.8 A and 102.6 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-27. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 27 VDC. Catalogue-rated output 3.8 A / 102.6 W. Continuous current range 0–3.8 A. Ripple and noise, maximum 150 mVp-p. Voltage adjustment 25.7–29.7 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 83%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 31–36.45 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-24

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-24

    MEAN WELL LPP-100-24 is a single-output, open-frame AC/DC power supply rated 24 V, 4.2 A and 100.8 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-24. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 24 VDC. Catalogue-rated output 4.2 A / 100.8 W. Continuous current range 0–4.2 A. Ripple and noise, maximum 150 mVp-p. Voltage adjustment 22.8–26.4 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 83%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 27.6–32.4 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-15

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-15

    MEAN WELL LPP-100-15 is a single-output, open-frame AC/DC power supply rated 15 V, 6.7 A and 100.5 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-15. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 15 VDC. Catalogue-rated output 6.7 A / 100.5 W. Continuous current range 0–6.7 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 14.3–16.5 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 80%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 17.25–20.25 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-13.5

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-13.5

    MEAN WELL LPP-100-13.5 is a single-output, open-frame AC/DC power supply rated 13.5 V, 7.5 A and 101.25 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-13.5. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 13.5 VDC. Catalogue-rated output 7.5 A / 101.25 W. Continuous current range 0–7.5 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 12.8–14.9 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 79%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 15.5–18.2 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-12

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-12

    MEAN WELL LPP-100-12 is a single-output, open-frame AC/DC power supply rated 12 V, 8.5 A and 102 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-12. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 12 VDC. Catalogue-rated output 8.5 A / 102 W. Continuous current range 0–8.5 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 11.4–13.2 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 79%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 13.8–16.2 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 50°C, decreasing along the curve to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-7.5

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-7.5

    MEAN WELL LPP-100-7.5 is a single-output, open-frame AC/DC power supply rated 7.5 V, 13.5 A and 101.25 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-7.5. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 7.5 VDC. Catalogue-rated output 13.5 A / 101.25 W. Continuous current range 0–13.3 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 7.13–8.25 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%. Efficiency, typical 76%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. For load sizing, observe the listed 0–13.3 A continuous current range; confirm requirements above 13.3 A with the manufacturer before using the separate 13.5 A rated-current entry. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 8.6–10.1 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 30°C, decreasing along the curve to 60% at 50°C. The no-fan curve ends at 50°C. Forced cooling With 18 CFM airflow at 15 cm: 100% load through 50°C, decreasing to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-5

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-5

    MEAN WELL LPP-100-5 is a single-output, open-frame AC/DC power supply rated 5 V, 20 A and 100 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-5. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 5 VDC. Catalogue-rated output 20 A / 100 W. Continuous current range 0–20 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 4.75–5.5 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%. Efficiency, typical 75%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 5.75–6.75 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 30°C, decreasing along the curve to 60% at 50°C. The no-fan curve ends at 50°C. Forced cooling With 18 CFM airflow at 15 cm: 100% load through 50°C, decreasing to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPP-100-3.3

    MEAN WELL LPP-100 series: Open-Frame AC/DC Power Supply with PFC - LPP-100-3.3

    MEAN WELL LPP-100-3.3 is a single-output, open-frame AC/DC power supply rated 3.3 V, 20 A and 66 W. Built-in active PFC and wide-range input support equipment integration. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPP-100 Datasheet (PDF) The LPP-100 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPP-100-3.3. Series and format LPP-100 single-output open-frame switching power supply. Power-factor correction Built-in active PFC. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 3.3 VDC. Catalogue-rated output 20 A / 66 W. Continuous current range 0–20 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 3.14–3.63 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%. Efficiency, typical 69%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 85–264 VAC; 47–63 Hz. DC input 120–370 VDC. AC input current, typical 1.7 A at 115 VAC; 0.75 A at 230 VAC. Cold-start inrush, typical 30 A at 230 VAC. Leakage current <2 mA at 240 VAC. Set-up / rise time 600 ms / 30 ms at 230 VAC; 1200 ms / 30 ms at 115 VAC, full load. Hold-up time, typical 28 ms at 230 VAC and 28 ms at 115 VAC, full load. Power factor, typical PF >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Switching frequencies PFC 67 kHz; PWM 134 kHz. Protection Short circuit / overload 105–150% of rated output power; constant-current limiting, with automatic recovery after fault removal. Overvoltage 3.8–4.45 V; output shuts down, re-power on to recover. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 30°C, decreasing along the curve to 60% at 50°C. The no-fan curve ends at 50°C. Forced cooling With 18 CFM airflow at 15 cm: 100% load through 50°C, decreasing to 60% at 60°C. Input-voltage derating At 60 Hz: 80% load at 85 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 33.6 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 5 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 AC/L; pins 2 and 4 no pin; pin 3 AC/N; pin 5 FG. DC output CN2 JST B8P-VH or equivalent. Pins 1–4 −V; pins 5–8 +V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, light-industry level; EAC TP TC020. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 510 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.51 kg per unit; 24 pieces / 13.9 kg / 1.63 CUFT. MTBF, minimum estimates 2586.7 thousand hours, Telcordia SR-332 (Bellcore); 287.9 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year manufacturer warranty, subject to applicable terms. Catalogue revision LPP-100-SPEC, 2024-10-30; PDF pages 9–10.

  • LPS-100-48

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-48

    MEAN WELL LPS-100-48 is a single-output, open-frame AC/DC power supply rated 48 V, 2.1 A and 100.8 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-48. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 48 VDC. Catalogue-rated output 2.1 A / 100.8 W. Continuous current range 0–2.1 A. Ripple and noise, maximum 200 mVp-p. Voltage adjustment 41–56 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 81%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power. Hiccup mode, with automatic recovery after fault removal. Overvoltage 57.6–67.2 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.

  • LPS-100-27

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-27

    MEAN WELL LPS-100-27 is a single-output, open-frame AC/DC power supply rated 27 V, 3.8 A and 102.6 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-27. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 27 VDC. Catalogue-rated output 3.8 A / 102.6 W. Continuous current range 0–3.8 A. Ripple and noise, maximum 150 mVp-p. Voltage adjustment 26–32 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 81%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power. Hiccup mode, with automatic recovery after fault removal. Overvoltage 33.7–39.2 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.

  • LPS-100-24

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-24

    MEAN WELL LPS-100-24 is a single-output, open-frame AC/DC power supply rated 24 V, 4.2 A and 100.8 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-24. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 24 VDC. Catalogue-rated output 4.2 A / 100.8 W. Continuous current range 0–4.2 A. Short-duration output 6 A / 144 W for 10 seconds; continuous output remains 4.2 A / 100.8 W. Ripple and noise, maximum 150 mVp-p. Voltage adjustment 20–26.4 V using +V ADJ. Voltage tolerance ±1.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Efficiency, typical 80%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power; the +24 V model is specified above 6.5 A. Hiccup mode, with automatic recovery after fault removal. Overvoltage 27.6–32.4 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Low-input load-step behaviour The datasheet notes output reduced to 20 V for 1 second for a 0 A-to-rated-load step at 85–89 VAC. This transient note does not extend the specified AC input ranges. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.

  • LPS-100-15

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-15

    MEAN WELL LPS-100-15 is a single-output, open-frame AC/DC power supply rated 15 V, 6.7 A and 100.5 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-15. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 15 VDC. Catalogue-rated output 6.7 A / 100.5 W. Continuous current range 0–6.7 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 13.5–18 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5%. Efficiency, typical 80%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power. Hiccup mode, with automatic recovery after fault removal. Overvoltage 18–21 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.

  • LPS-100-13.5

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-13.5

    MEAN WELL LPS-100-13.5 is a single-output, open-frame AC/DC power supply rated 13.5 V, 7.5 A and 101.25 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-13.5. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 13.5 VDC. Catalogue-rated output 7.5 A / 101.25 W. Continuous current range 0–7.5 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 12–15 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5%. Efficiency, typical 79%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power. Hiccup mode, with automatic recovery after fault removal. Overvoltage 15.5–18.2 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.

  • LPS-100-12

    MEAN WELL LPS-100 series: Open-Frame AC/DC Power Supply - LPS-100-12

    MEAN WELL LPS-100-12 is a single-output, open-frame AC/DC power supply rated 12 V, 8.4 A and 100.8 W. It uses automatic 115/230 VAC range switching without PFC. Apply the model-specific cooling and input limits when sizing the load. Product Datasheet Download MEAN WELL LPS-100 Datasheet (PDF) The LPS-100 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model LPS-100-12. Series and format LPS-100 single-output open-frame switching power supply. Power-factor correction No PFC function. Cooling selection Natural convection subject to the voltage-specific derating curve; forced airflow extends the applicable thermal range. Factory burn-in 100% full-load burn-in test. Output Ratings Nominal output 12 VDC. Catalogue-rated output 8.4 A / 100.8 W. Continuous current range 0–8.4 A. Ripple and noise, maximum 100 mVp-p. Voltage adjustment 10–13.2 V using +V ADJ. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5%. Efficiency, typical 79%. Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input and Timing AC input 88–132 VAC or 176–264 VAC, automatic range switching; 47–63 Hz. DC input 248–370 VDC, with negative to AC/N and positive to AC/L. AC input current, typical 2.3 A at 115 VAC; 1.5 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Leakage current <1 mA at 240 VAC. Set-up / rise time 800 ms / 50 ms at 230 VAC; 1200 ms / 50 ms at 115 VAC, full load. Hold-up time, typical 20 ms at 230 VAC and 20 ms at 115 VAC, full load. Switching operation Fixed-frequency switching; automatic 115/230 VAC range selection. Protection Short circuit / overload 105–140% of rated output power. Hiccup mode, with automatic recovery after fault removal. Overvoltage 13.8–16.2 V; hiccup mode, with automatic recovery after fault removal. Cooling and Environment Working ambient −10 to +60°C, subject to the horizontal-installation derating curves. Natural convection 100% load through 40°C, decreasing along the model curve to 50% at 60°C. Forced cooling With at least 18 CFM airflow: 100% load through 50°C, decreasing to approximately 70% at 60°C. Static characteristics The 12 V output and ripple curves are characterized versus AC input at 60 Hz; use them together with the stated input ranges, not as an extended input rating. Altitude derating Above 2000 m, reduce the allowable ambient by 3.5°C per 1000 m for fanless cooling, or 5°C per 1000 m with fan cooling. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH. Temperature coefficient ±0.05%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the output table and all applicable derating limits together. Forced airflow changes the thermal limit; it does not increase the continuous electrical rating. Dimensions and Installation Dimensions, L × W × H 222 × 62 × 32 mm. Mounting Four Ø3.5 mm holes; 212 × 52 mm hole-center spans, with 5 mm edge offsets. General drawing tolerance ±1 mm. Underside clearance The mechanical drawing shows 3 mm maximum underside projection; allow clearance for safe installation. Safety earth Grounding is required. CN1 pin 1 is safety ground; connect the marked FG point as shown. Fitted fuse and adjustment AC fuse F4A/250V and +V ADJ control are identified in the drawing. EMI mounting grounds Mounting holes M1 and M2 are specified as grounded for EMI purposes. Use the complete mechanical drawing for connector orientation, mounting and clearance. Install this component power supply in a suitable final-equipment enclosure. Connections and Mating Parts AC input CN1 JST B5P-VH or equivalent. Pin 1 FG; pins 2 and 4 no pin; pin 3 AC/N (DC −); pin 5 AC/L (DC +). DC output CN2 JST B8P-VH or equivalent. Pins 1–4 +V; pins 5–8 −V. Mating housings JST VHR housing family or equivalent, selected to match each connector circuit count. Mating contacts JST SVH-21T-P1.1 or equivalent. Select the complete mating housing for the required circuit count and wire assembly. Loose mating parts, an external fan and mounting hardware are not stated as included. Safety and EMC Safety approvals UL62368-1, TUV BS EN/EN62368-1 and EAC TP TC004 approved; the cover also identifies IEC62368-1 CB certification. Withstand voltage Input/output 3 kVAC; input/FG 2 kVAC; output/FG 0.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2,3,4,5,6,11; BS EN/EN55035, light-industry level; EAC TP TC020. Harmonic-current test condition Testing at 90% load. EMC testing uses a 360 × 360 mm metal plate, 1 mm thick. Reconfirm EMC compliance in the completed equipment with its actual wiring and mounting. Component approvals do not certify the complete system. Weight and Reliability Single-unit catalogue reference weight 450 g from the explicit per-unit PACKING value; a catalogue reference rather than measured net or shipping weight. Packing reference 0.45 kg per unit; 24 pieces / 12.5 kg / 1.63 CUFT. MTBF, minimum estimates 2983.9 thousand hours, Telcordia SR-332 (Bellcore); 342.6 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 2-year manufacturer warranty, subject to applicable terms. Catalogue revision LPS-100-SPEC, 2024-10-30; PDF pages 7–8.


You have seen 24 out of 46 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa