NGE Series: Interchangeable Plug Green Power Adapter , Fast Charging

120 products

MEAN WELL NGE Series Interchangeable Plug Power Adapters

  • Product Features
  • General Specifications
  • Series Overview
  • Ordering Information

Product Features

  • Interchangeable AC Plugs: Equipped with global interchangeable AC plugs (I, U, E), making it ideal for international travel and cross-border equipment deployment.
  • High Efficiency & "Green" Power: Energy-efficient design complying with DoE Level VI standards, minimizing power consumption.
  • Wide Input Range: Universal AC input (80~264VAC) allows for seamless operation in different regions.
  • Industrial-Grade Reliability: Engineered for extreme environments with an operating temperature range of -30°C to +70°C.
  • Rugged Protections: Integrated Short circuit, Overload, and Over voltage protections with auto-recovery functionality.
  • Compact & Versatile: Available in power outputs from 12W to 100W (GaN), perfect for consumer electronics, communication devices, and industrial instrumentation.
  • Global Safety Certifications: Complies with international standards including UL, CB, TUV, PSE, CCC, and RCM.

General Specifications

Item Specification Detail
Input Voltage 80 ~ 264VAC
Operating Temp. -30°C to +70°C (Refer to derating curves)
Isolation I/P-O/P: 4000VAC
Efficiency Up to 92% (model dependent)
Safety Standards IEC 62368-1, UL, DEKRA, PSE, CCC, KC, BIS
MTBF > 600k ~ 7000k hours (model dependent)

Series Overview

Series Rated Power Key Application
NGE12 12W Low-power electronics
NGE18 18W General electronics
NGE30 30W Networking/Comm
NGE45 45W Industrial/Consumer
NGE65 65W Laptops/High-perf
NGE90 90W High-power industrial
NGE100 100W 4-Port USB GaN Charger
Note: The NGE series offers a modular design with interchangeable plugs, reducing inventory requirements for global operations. The NGE100 features GaN technology for ultra-fast, multi-port charging.

Product Ordering Code

Part Example Description
Series NGE12 12W Adapter
Plug Type I / U / E US / EU / UK / Interchangeable
Voltage 12 12V DC Output
Output Plug P1J Connector specification
Example:
NGE12I12-P1J: 12W, Interchangeable plug, 12V output, P1J connector.
NGE100U: 100W GaN USB charger with Universal plug option.
  • MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U09-P1J MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U09-P1J

    MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U09-P1J

    MEAN WELL NGE65U09-P1J is an NGE65 Class II wall-mounted AC/DC power adapter supplying 9 VDC at 5.96 A, rated 53.6 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE65 Datasheet (PDF) The NGE65 section is on PDF pages 31, 32, 33, 34, 35, 36, 37. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE65U09-P1J. Series / voltage code NGE65 series; code 09 denotes 9 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 9 VDC. Rated current / current range 5.96 A rated; operating range 0–5.96 A. Rated output power 53.6 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 100 mVp-p under the stated test conditions. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 89% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1500 / 50 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 3000 / 50 / 10 ms at full load. No-load consumption Less than 0.075 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 110–150% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +60°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 65 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 196 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 35 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. The NGE65 feature list states compliance with LPS (limited power source) requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Harmonic current is tested at 85% load. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 5.96 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 682.2 thousand hours, MIL-HDBK-217F at 25°C; 5852.4 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 31–37. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U12-P1J MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U12-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U12-P1J

    MEAN WELL NGE30U12-P1J is a 12 V single-output wall-mounted AC/DC adapter rated at 2.5 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U12-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 12: 12 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 12 V Rated current / current range 2.5 A rated; 0–2.5 A operating range. Rated output power 30 W Ripple and noise, maximum 120 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 88.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1200 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE90U55-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U55-P1J

    MEAN WELL NGE90U55-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 55 VDC at 1.64 A, rated 90.2 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U55-P1J. Series / voltage code NGE90 series; code 55 denotes 55 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 55 VDC. Rated current / current range 1.64 A rated; operating range 0–1.64 A. Rated output power 90.2 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 60.5–74.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 55 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90U48-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U48-P1J

    MEAN WELL NGE90U48-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 48 VDC at 1.875 A, rated 90 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U48-P1J. Series / voltage code NGE90 series; code 48 denotes 48 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 48 VDC. Rated current / current range 1.875 A rated; operating range 0–1.875 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 52.8–64.8 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 48 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90U24-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U24-P1J

    MEAN WELL NGE90U24-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 24 VDC at 3.75 A, rated 90 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U24-P1J. Series / voltage code NGE90 series; code 24 denotes 24 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 24 VDC. Rated current / current range 3.75 A rated; operating range 0–3.75 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 26.4–32.4 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90U18-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U18-P1J

    MEAN WELL NGE90U18-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 18 VDC at 5 A, rated 90 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U18-P1J. Series / voltage code NGE90 series; code 18 denotes 18 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 18 VDC. Rated current / current range 5 A rated; operating range 0–5 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 180 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91.5% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 19.8–24.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90U15-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U15-P1J

    MEAN WELL NGE90U15-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 15 VDC at 5.5 A, rated 82.5 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U15-P1J. Series / voltage code NGE90 series; code 15 denotes 15 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 15 VDC. Rated current / current range 5.5 A rated; operating range 0–5.5 A. Rated output power 82.5 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 150 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 15.8–20.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 5.5 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90U12-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90U12-P1J

    MEAN WELL NGE90U12-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 12 VDC at 6.25 A, rated 75 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90U12-P1J. Series / voltage code NGE90 series; code 12 denotes 12 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 12 VDC. Rated current / current range 6.25 A rated; operating range 0–6.25 A. Rated output power 75 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 120 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 90% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 12.6–16.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 6.25 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E55-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E55-P1J

    MEAN WELL NGE90E55-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 55 VDC at 1.64 A, rated 90.2 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E55-P1J. Series / voltage code NGE90 series; code 55 denotes 55 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 55 VDC. Rated current / current range 1.64 A rated; operating range 0–1.64 A. Rated output power 90.2 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 60.5–74.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 55 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E48-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E48-P1J

    MEAN WELL NGE90E48-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 48 VDC at 1.875 A, rated 90 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E48-P1J. Series / voltage code NGE90 series; code 48 denotes 48 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 48 VDC. Rated current / current range 1.875 A rated; operating range 0–1.875 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 52.8–64.8 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 48 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E24-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E24-P1J

    MEAN WELL NGE90E24-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 24 VDC at 3.75 A, rated 90 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E24-P1J. Series / voltage code NGE90 series; code 24 denotes 24 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 24 VDC. Rated current / current range 3.75 A rated; operating range 0–3.75 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 26.4–32.4 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E18-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E18-P1J

    MEAN WELL NGE90E18-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 18 VDC at 5 A, rated 90 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E18-P1J. Series / voltage code NGE90 series; code 18 denotes 18 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 18 VDC. Rated current / current range 5 A rated; operating range 0–5 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 180 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91.5% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 19.8–24.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E15-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E15-P1J

    MEAN WELL NGE90E15-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 15 VDC at 5.5 A, rated 82.5 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E15-P1J. Series / voltage code NGE90 series; code 15 denotes 15 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 15 VDC. Rated current / current range 5.5 A rated; operating range 0–5.5 A. Rated output power 82.5 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 150 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 15.8–20.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 5.5 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90E12-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90E12-P1J

    MEAN WELL NGE90E12-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 12 VDC at 6.25 A, rated 75 W, with a center-positive P1J DC plug. EU E-type with a fixed, non-interchangeable, non-folding AC plug. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90E12-P1J. Series / voltage code NGE90 series; code 12 denotes 12 VDC. AC version EU E-type with a fixed, non-interchangeable, non-folding AC plug. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 12 VDC. Rated current / current range 6.25 A rated; operating range 0–6.25 A. Rated output power 75 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 120 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 90% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 12.6–16.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 231 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The E-type certificate panel shows CB, DEKRA, EAC and CE marks. Do not apply the I-type regional approval list to this fixed-EU version. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 6.25 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I55-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I55-P1J

    MEAN WELL NGE90I55-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 55 VDC at 1.64 A, rated 90.2 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I55-P1J. Series / voltage code NGE90 series; code 55 denotes 55 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 55 VDC. Rated current / current range 1.64 A rated; operating range 0–1.64 A. Rated output power 90.2 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 60.5–74.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 55 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I48-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I48-P1J

    MEAN WELL NGE90I48-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 48 VDC at 1.875 A, rated 90 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I48-P1J. Series / voltage code NGE90 series; code 48 denotes 48 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 48 VDC. Rated current / current range 1.875 A rated; operating range 0–1.875 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 52.8–64.8 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Additional low-temperature limit For this 48 V model at 80 VAC: reduce load to 60% at −20°C and 35% at −30°C. These limits apply in addition to the general input and temperature curves. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I24-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I24-P1J

    MEAN WELL NGE90I24-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 24 VDC at 3.75 A, rated 90 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I24-P1J. Series / voltage code NGE90 series; code 24 denotes 24 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 24 VDC. Rated current / current range 3.75 A rated; operating range 0–3.75 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 26.4–32.4 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1200 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I18-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I18-P1J

    MEAN WELL NGE90I18-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 18 VDC at 5 A, rated 90 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I18-P1J. Series / voltage code NGE90 series; code 18 denotes 18 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 18 VDC. Rated current / current range 5 A rated; operating range 0–5 A. Rated output power 90 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 180 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91.5% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 19.8–24.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I15-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I15-P1J

    MEAN WELL NGE90I15-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 15 VDC at 5.5 A, rated 82.5 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I15-P1J. Series / voltage code NGE90 series; code 15 denotes 15 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 15 VDC. Rated current / current range 5.5 A rated; operating range 0–5.5 A. Rated output power 82.5 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 150 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 91% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 15.8–20.3 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 5.5 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE90I12-P1J

    MEAN WELL NGE90 series: Wall-Mounted AC/DC Power Adapter - NGE90I12-P1J

    MEAN WELL NGE90I12-P1J is an NGE90 Class II wall-mounted AC/DC power adapter supplying 12 VDC at 6.25 A, rated 75 W, with a center-positive P1J DC plug. Universal I-type with interchangeable AC plug heads and non-folding pins. The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Product Datasheet Download MEAN WELL NGE90 Datasheet (PDF) The NGE90 section is on PDF pages 38, 39, 40, 41, 42, 43, 44. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE90I12-P1J. Series / voltage code NGE90 series; code 12 denotes 12 VDC. AC version Universal I-type with interchangeable AC plug heads and non-folding pins. Supply arrangement The main body and compatible AC inlet plug are ordered separately. Fit one approved interchangeable plug before use. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 12 VDC. Rated current / current range 6.25 A rated; operating range 0–6.25 A. Rated output power 75 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 120 mVp-p under the stated test conditions. Voltage tolerance ±4%. Line regulation ±1%. Load regulation ±4%. Efficiency, typical 90% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1000 / 60 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 1000 / 60 / 10 ms at full load. No-load consumption Less than 0.1 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 105–160% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 12.6–16.2 V; output shutdown, reapply input power to recover. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +55°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 85.5 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 16 AWG, 1000 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 217 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 42 for the exact body, cable and AC-pin arrangement. Separately Ordered AC Plugs AC PLUG-EU4 European. AC PLUG-US4 US. AC PLUG-UK4 UK. AC PLUG-AU4 Australian. AC PLUG-CN4 Chinese. AC PLUG-KR4 Korean. AC PLUG-IN4 Indian. AC PLUG-MIX4 EU, US, UK, AU and CN five-type set. AC PLUG-MIX5 EU, US, UK, AU, CN, KR and IN seven-type set. Use only the NGE I-type interface. The listed plug accessories fit NGE12I / NGE18I / NGE30I / NGE45I / NGE65I / NGE90I; they do not convert E-type or U-type bodies. Slide the selected AC head along the guide rail between the metal prongs until it clicks into the locked position. Check that it is secure and correctly fitted before use. The adapter body and plug head are separate orders. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The I-type certificate panel shows CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, UL medical recognition, EAC, KC, BIS, CE, UKCA and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry this model's full 6.25 A output; restrict the load through them to 5 A or choose a suitably rated connection. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 605.3 thousand hours, MIL-HDBK-217F at 25°C; 5120.6 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 38–44. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. The NGE90 application list also includes PoE power-sourcing equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE65U48-P1J

    MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U48-P1J

    MEAN WELL NGE65U48-P1J is an NGE65 Class II wall-mounted AC/DC power adapter supplying 48 VDC at 1.36 A, rated 65.2 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE65 Datasheet (PDF) The NGE65 section is on PDF pages 31, 32, 33, 34, 35, 36, 37. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE65U48-P1J. Series / voltage code NGE65 series; code 48 denotes 48 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 48 VDC. Rated current / current range 1.36 A rated; operating range 0–1.36 A. Rated output power 65.2 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±2%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1500 / 50 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 3000 / 50 / 10 ms at full load. No-load consumption Less than 0.075 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 110–150% of rated output power. Output shutdown and latch-off; reapply input power to recover. Overvoltage 110–140% of rated output voltage; Zener-diode clamp. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +60°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 65 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 18 AWG, 1500 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 196 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 35 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. The NGE65 feature list states compliance with LPS (limited power source) requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Harmonic current is tested at 85% load. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 682.2 thousand hours, MIL-HDBK-217F at 25°C; 5852.4 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 31–37. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE65U24-P1J

    MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U24-P1J

    MEAN WELL NGE65U24-P1J is an NGE65 Class II wall-mounted AC/DC power adapter supplying 24 VDC at 2.71 A, rated 65 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE65 Datasheet (PDF) The NGE65 section is on PDF pages 31, 32, 33, 34, 35, 36, 37. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE65U24-P1J. Series / voltage code NGE65 series; code 24 denotes 24 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 24 VDC. Rated current / current range 2.71 A rated; operating range 0–2.71 A. Rated output power 65 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 240 mVp-p under the stated test conditions. Voltage tolerance ±2%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 92% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1500 / 50 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 3000 / 50 / 10 ms at full load. No-load consumption Less than 0.075 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 110–150% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +60°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 65 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 18 AWG, 1500 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 196 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 35 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. The NGE65 feature list states compliance with LPS (limited power source) requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Harmonic current is tested at 85% load. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 682.2 thousand hours, MIL-HDBK-217F at 25°C; 5852.4 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 31–37. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE65U18-P1J

    MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U18-P1J

    MEAN WELL NGE65U18-P1J is an NGE65 Class II wall-mounted AC/DC power adapter supplying 18 VDC at 3.62 A, rated 65.1 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE65 Datasheet (PDF) The NGE65 section is on PDF pages 31, 32, 33, 34, 35, 36, 37. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE65U18-P1J. Series / voltage code NGE65 series; code 18 denotes 18 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 18 VDC. Rated current / current range 3.62 A rated; operating range 0–3.62 A. Rated output power 65.1 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 180 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 91% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1500 / 50 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 3000 / 50 / 10 ms at full load. No-load consumption Less than 0.075 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 110–150% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +60°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 65 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 18 AWG, 1500 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 196 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 35 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. The NGE65 feature list states compliance with LPS (limited power source) requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Harmonic current is tested at 85% load. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 682.2 thousand hours, MIL-HDBK-217F at 25°C; 5852.4 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 31–37. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.

  • NGE65U15-P1J

    MEAN WELL NGE65 series: Wall-Mounted AC/DC Power Adapter - NGE65U15-P1J

    MEAN WELL NGE65U15-P1J is an NGE65 Class II wall-mounted AC/DC power adapter supplying 15 VDC at 4.34 A, rated 65.1 W, with a center-positive P1J DC plug. US U-type with a non-interchangeable AC plug and folding pins. This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Product Datasheet Download MEAN WELL NGE65 Datasheet (PDF) The NGE65 section is on PDF pages 31, 32, 33, 34, 35, 36, 37. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model NGE65U15-P1J. Series / voltage code NGE65 series; code 15 denotes 15 VDC. AC version US U-type with a non-interchangeable AC plug and folding pins. Supply arrangement This version has its own non-interchangeable mains plug; NGE interchangeable AC plug heads are not compatible with it. Standard DC connector P1J tuning-fork plug, center positive and outside negative; 5.5 mm OD × 2.1 mm ID × 11 ± 0.5 mm length. Output Ratings DC output voltage 15 VDC. Rated current / current range 4.34 A rated; operating range 0–4.34 A. Rated output power 65.1 W. Observe both rated current and power, with applicable derating. Ripple and noise, maximum 150 mVp-p under the stated test conditions. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 90% under the general test conditions. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA RMS at 264 VAC. Set-up / rise / hold-up, 230 VAC 1500 / 50 / 30 ms at full load. Set-up / rise / hold-up, 115 VAC 3000 / 50 / 10 ms at full load. No-load consumption Less than 0.075 W. Energy efficiency Level VI. The catalogue also states design compliance with US DoE Level VII under docket EERE-2020-BT-STD-0006. The series description lists EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC Version 5. Apply the regulatory scope relevant to the supplied regional version. Protection Short circuit / overload Overload threshold: 110–150% of rated output power. Hiccup mode; automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp. Operating Conditions and Derating Operating temperature −30 to +70°C, subject to the derating curve. Ambient-temperature curve 100% load from −30 to +40°C; marked points are 70% at +60°C and 50% at +70°C. Follow the plotted curve between the marked points. Input-voltage curve At 60 Hz: 80% load at 80 VAC, rising to 100% at 100 VAC; 100% from 100 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage temperature / humidity −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes each along X, Y and Z axes. Apply the most restrictive input, ambient-temperature and model-specific load limits. The maximum working temperature is not a full-load rating. Mechanical Details and Cable Main-body dimensions 62 × 30 × 65 mm, as listed in the catalogue dimension table. The body is 30 mm thick; allow additional clearance for AC pins or an interchangeable plug head. DC cable UL1185 18 AWG, 1500 ± 50 mm for this voltage model. Drawing tolerance Mechanical drawing dimensions in millimetres, general tolerance ±1 mm unless otherwise marked. Catalogue main-body weight 196 g; explicit catalogue packing reference per main body, not a measured net or shipping weight. Refer to PDF page 35 for the exact body, cable and AC-pin arrangement. Safety and Application Scope Construction Class II power supply without an earth pin or functional ground; enclosed 94V-0 flame-retardant plastic body. Medical application 2 × MOPP (means of patient protection) and suitability for BF-type applications, subject to the complete equipment evaluation. Ingress protection IP21. Withstand voltage Input to output: 4000 VAC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. Core safety standards CB: IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. DEKRA: corresponding BS EN/EN62368-1, 60601-1/-1-11, 61558-1/-2-16 and 60335-1. North American standards, applicable versions UL62368-1; CSA C22.2 No. 62368-1; ANSI/AAMI ES60601-1/-1-11 (3.2 version); CAN/CSA-C22.2 No. 60601-1/-1-11. The additional ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11 line is identified for U-type only. Other regional listings, applicable versions PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1 and AS/NZS 61558.1/.2.16; EAC TP TC 004; CCC GB4943.1; KC KC62368-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005. The U-type certificate panel shows CB, PSE, UL/cUL, BSMI, UL medical recognition and FCC marks. The multi-field listings describe the adapter and apply by version and approval scope. They do not certify the connected medical device or complete installation; check the applicable product label and equipment-level requirements. The NGE65 feature list states compliance with LPS (limited power source) requirements. EMC Conducted and radiated emissions Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current BS EN/EN61000-3-2, Class A. Harmonic current is tested at 85% load. Immunity framework BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. ESD BS EN/EN61000-4-2: Level 4, 15 kV air; Level 4, 8 kV contact. RF field BS EN/EN61000-4-3: Level 2, 3 V/m. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV. Surge BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF BS EN/EN61000-4-6: Level 2, 3 V. Magnetic field BS EN/EN61000-4-8: Level 2, 3 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period, 30% dip for 25 periods, and >95% interruption for 250 periods. The power supply is an independent unit; the final equipment must still be assessed for compliance with EMC directives. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). R-suffix codes are right-angled; the others are straight. No quick adapter is listed. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent; no quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. EIAJ equivalent; quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1 (ribbed) = +Vo; lead 2 (lettered) = −Vo. Standard illustrated lengths: L = 25 mm and L1 = 10 mm; other lengths by request. No quick adapter is listed. The listed order model has the standard P1J plug. An optional connector can be factory-customized subject to a minimum order quantity. Quick adapters are separate accessories with no minimum order quantity, and are available only where the table lists them. An adapter does not increase the supply rating. Match voltage, polarity, mating dimensions and the lowest current rating of the supply, cable and connectors. Optional parts are not automatically included. Measurement Conditions and Reliability General test conditions 230 VAC input, rated load, 25°C and 70% RH unless otherwise stated. Output-voltage setting Measured at the DC plug terminals at 50% load. Ripple / noise test 20 MHz bandwidth, using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation tests Line regulation: low-to-high input at rated load. Load regulation: 0–100% rated load. Voltage tolerance includes set-up tolerance, line regulation and load regulation. MTBF, minimum 682.2 thousand hours, MIL-HDBK-217F at 25°C; 5852.4 thousand hours, Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision / pages 2026-01-14; combined PDF pages 31–37. Application examples include consumer electronics, telecommunications, office, industrial, medical and household equipment. Select the correct DC voltage, polarity, regional mains version and current capacity for the equipment.


You have seen 24 out of 120 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa