NGE Series: Interchangeable Plug Green Power Adapter , Fast Charging

120 products

MEAN WELL NGE Series Interchangeable Plug Power Adapters

  • Product Features
  • General Specifications
  • Series Overview
  • Ordering Information

Product Features

  • Interchangeable AC Plugs: Equipped with global interchangeable AC plugs (I, U, E), making it ideal for international travel and cross-border equipment deployment.
  • High Efficiency & "Green" Power: Energy-efficient design complying with DoE Level VI standards, minimizing power consumption.
  • Wide Input Range: Universal AC input (80~264VAC) allows for seamless operation in different regions.
  • Industrial-Grade Reliability: Engineered for extreme environments with an operating temperature range of -30°C to +70°C.
  • Rugged Protections: Integrated Short circuit, Overload, and Over voltage protections with auto-recovery functionality.
  • Compact & Versatile: Available in power outputs from 12W to 100W (GaN), perfect for consumer electronics, communication devices, and industrial instrumentation.
  • Global Safety Certifications: Complies with international standards including UL, CB, TUV, PSE, CCC, and RCM.

General Specifications

Item Specification Detail
Input Voltage 80 ~ 264VAC
Operating Temp. -30°C to +70°C (Refer to derating curves)
Isolation I/P-O/P: 4000VAC
Efficiency Up to 92% (model dependent)
Safety Standards IEC 62368-1, UL, DEKRA, PSE, CCC, KC, BIS
MTBF > 600k ~ 7000k hours (model dependent)

Series Overview

Series Rated Power Key Application
NGE12 12W Low-power electronics
NGE18 18W General electronics
NGE30 30W Networking/Comm
NGE45 45W Industrial/Consumer
NGE65 65W Laptops/High-perf
NGE90 90W High-power industrial
NGE100 100W 4-Port USB GaN Charger
Note: The NGE series offers a modular design with interchangeable plugs, reducing inventory requirements for global operations. The NGE100 features GaN technology for ultra-fast, multi-port charging.

Product Ordering Code

Part Example Description
Series NGE12 12W Adapter
Plug Type I / U / E US / EU / UK / Interchangeable
Voltage 12 12V DC Output
Output Plug P1J Connector specification
Example:
NGE12I12-P1J: 12W, Interchangeable plug, 12V output, P1J connector.
NGE100U: 100W GaN USB charger with Universal plug option.
  • NGE45E24-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E24-P1J

    MEAN WELL NGE45E24-P1J is a 24 V single-output wall-mounted AC/DC adapter rated at 1.88 A and 45.1 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E24-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 24: 24 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 24 V Rated current / current range 1.88 A rated; 0–1.88 A operating range. Rated output power 45.1 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45E18-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E18-P1J

    MEAN WELL NGE45E18-P1J is an 18 V single-output wall-mounted AC/DC adapter rated at 2.5 A and 45 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E18-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 18: 18 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 18 V Rated current / current range 2.5 A rated; 0–2.5 A operating range. Rated output power 45 W Ripple and noise, maximum 180 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45E15-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E15-P1J

    MEAN WELL NGE45E15-P1J is a 15 V single-output wall-mounted AC/DC adapter rated at 3 A and 45 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E15-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 15: 15 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 15 V Rated current / current range 3 A rated; 0–3 A operating range. Rated output power 45 W Ripple and noise, maximum 150 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 18 AWG, 1500 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45E12-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E12-P1J

    MEAN WELL NGE45E12-P1J is a 12 V single-output wall-mounted AC/DC adapter rated at 3.75 A and 45 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E12-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 12: 12 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 12 V Rated current / current range 3.75 A rated; 0–3.75 A operating range. Rated output power 45 W Ripple and noise, maximum 120 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45E09-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E09-P1J

    MEAN WELL NGE45E09-P1J is a 9 V single-output wall-mounted AC/DC adapter rated at 4.5 A and 40.5 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E09-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 09: 9 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 9 V Rated current / current range 4.5 A rated; 0–4.5 A operating range. Rated output power 40.5 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 89% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45E05-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Fixed EU Plug - NGE45E05-P1J

    MEAN WELL NGE45E05-P1J is a 5 V single-output wall-mounted AC/DC adapter rated at 5.63 A and 28.1 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45E05-P1J Series NGE45 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 05: 5 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 5 V Rated current / current range 5.63 A rated; 0–5.63 A operating range. Rated output power 28.1 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 84% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 211 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. The 5 A P3A/P3B/P3C quick adapters cannot carry this model's full 5.63 A output. Use them only with a load of 5 A or less, also respecting voltage, polarity and all other limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I48-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I48-P1J

    MEAN WELL NGE45I48-P1J is a 48 V single-output wall-mounted AC/DC adapter rated at 0.94 A and 45.1 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I48-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 48: 48 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 48 V Rated current / current range 0.94 A rated; 0–0.94 A operating range. Rated output power 45.1 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 91% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery Shutdown and latched output off; re-power on to recover. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I24-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I24-P1J

    MEAN WELL NGE45I24-P1J is a 24 V single-output wall-mounted AC/DC adapter rated at 1.88 A and 45.1 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I24-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 24: 24 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 24 V Rated current / current range 1.88 A rated; 0–1.88 A operating range. Rated output power 45.1 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I18-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I18-P1J

    MEAN WELL NGE45I18-P1J is an 18 V single-output wall-mounted AC/DC adapter rated at 2.5 A and 45 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I18-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 18: 18 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 18 V Rated current / current range 2.5 A rated; 0–2.5 A operating range. Rated output power 45 W Ripple and noise, maximum 180 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I15-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I15-P1J

    MEAN WELL NGE45I15-P1J is a 15 V single-output wall-mounted AC/DC adapter rated at 3 A and 45 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I15-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 15: 15 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 15 V Rated current / current range 3 A rated; 0–3 A operating range. Rated output power 45 W Ripple and noise, maximum 150 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 18 AWG, 1500 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I12-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I12-P1J

    MEAN WELL NGE45I12-P1J is a 12 V single-output wall-mounted AC/DC adapter rated at 3.75 A and 45 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I12-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 12: 12 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 12 V Rated current / current range 3.75 A rated; 0–3.75 A operating range. Rated output power 45 W Ripple and noise, maximum 120 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 90% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I09-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I09-P1J

    MEAN WELL NGE45I09-P1J is a 9 V single-output wall-mounted AC/DC adapter rated at 4.5 A and 40.5 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I09-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 09: 9 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 9 V Rated current / current range 4.5 A rated; 0–4.5 A operating range. Rated output power 40.5 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 89% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE45I05-P1J

    MEAN WELL NGE45 series: AC/DC Adapter with Interchangeable AC Plugs - NGE45I05-P1J

    MEAN WELL NGE45I05-P1J is a 5 V single-output wall-mounted AC/DC adapter rated at 5.63 A and 28.1 W. Universal interchangeable-plug version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE45 Datasheet (PDF) The NGE45 section is on PDF pages 24, 25, 26, 27, 28, 29, 30. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE45I05-P1J Series NGE45 single-output AC/DC adapter. AC version code I: Fixed, non-folding AC pins; interchangeable inlet plugs. Output code 05: 5 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 5 V Rated current / current range 5.63 A rated; 0–5.63 A operating range. Rated output power 28.1 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 84% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 50 / 30 ms at 230 VAC; 3000 / 50 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. Universal-version certificate panel includes CB, DEKRA, PSE, UL/cUL, RCM, CCC, BSMI, cURus, EAC, KC, BIS, CE, UKCA and FCC. Series standards include IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60335-1; UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version) and CAN/CSA-C22.2 No. 60601-1; J62368-1, CNS15598-1, AS/NZS 62368.1 and 61558.1/.2.16, TPTC004, GB4943.1, KC62368-1 and IS13252 (part 1):2010 / IEC60950-1:2005. Match the supplied inlet plug and intended market to the applicable approval; the specification separately limits its North-American -1-11 listing to the U version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding AC pins; interchangeable inlet plugs. Output cable UL1185, 16 AWG, 1000 ±50 mm. Single-unit reference mass 196 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. Interchangeable AC inlet plugs AC PLUG-EU4 European type; ordered separately. AC PLUG-US4 US type; ordered separately. AC PLUG-UK4 U.K. type; ordered separately. AC PLUG-AU4 Australian type; ordered separately. AC PLUG-CN4 China type; ordered separately. AC PLUG-KR4 Korea type; ordered separately. AC PLUG-IN4 India type; ordered separately. AC PLUG-MIX4 Five-type set: EU, US, UK, AU and CN; ordered separately. AC PLUG-MIX5 Seven-type set: EU, US, UK, AU, CN, KR and IN; ordered separately. Order the main body and AC inlet plug separately. One compatible EU, US, UK, AU, CN, KR or IN plug is required per adapter; the pictured set is not an included bundle. These AC accessories are specifically listed for NGE12/18/30/45/65/90 I-type bodies. With the adapter disconnected from mains, slide the selected AC converter along the guided rail between the metal prongs until it clicks and locks. Check that the plug is stable and correct before use. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. The 5 A P3A/P3B/P3C quick adapters cannot carry this model's full 5.63 A output. Use them only with a load of 5 A or less, also respecting voltage, polarity and all other limits. Reliability and measurement notes MTBF, minimum 749.9 kh using MIL-HDBK-217F at 25°C; 6361.6 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U48-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U48-P1J

    MEAN WELL NGE30U48-P1J is a 48 V single-output wall-mounted AC/DC adapter rated at 0.63 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U48-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 48: 48 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 48 V Rated current / current range 0.63 A rated; 0–0.63 A operating range. Rated output power 30 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 91.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery Shutdown and latched output off; re-power on to recover. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U24-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U24-P1J

    MEAN WELL NGE30U24-P1J is a 24 V single-output wall-mounted AC/DC adapter rated at 1.25 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U24-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 24: 24 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 24 V Rated current / current range 1.25 A rated; 0–1.25 A operating range. Rated output power 30 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 88.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U18-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U18-P1J

    MEAN WELL NGE30U18-P1J is an 18 V single-output wall-mounted AC/DC adapter rated at 1.66 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U18-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 18: 18 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 18 V Rated current / current range 1.66 A rated; 0–1.66 A operating range. Rated output power 30 W Ripple and noise, maximum 180 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 88% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U15-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U15-P1J

    MEAN WELL NGE30U15-P1J is a 15 V single-output wall-mounted AC/DC adapter rated at 2 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U15-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 15: 15 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 15 V Rated current / current range 2 A rated; 0–2 A operating range. Rated output power 30 W Ripple and noise, maximum 150 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 87% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 18 AWG, 1500 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U09-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U09-P1J

    MEAN WELL NGE30U09-P1J is a 9 V single-output wall-mounted AC/DC adapter rated at 3.33 A and 30 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U09-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 09: 9 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 9 V Rated current / current range 3.33 A rated; 0–3.33 A operating range. Rated output power 30 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 87.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1200 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30U05-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Foldable US Plug - NGE30U05-P1J

    MEAN WELL NGE30U05-P1J is a 5 V single-output wall-mounted AC/DC adapter rated at 4 A and 20 W. US version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30U05-P1J Series NGE30 single-output AC/DC adapter. AC version code U: Foldable US AC pins; non-interchangeable plug. Output code 05: 5 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 5 V Rated current / current range 4 A rated; 0–4 A operating range. Rated output power 20 W Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line regulation ±1.0% Load regulation ±5.0% Efficiency, typical 82.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. US-version certificate panel: CB, PSE, UL/cUL, BSMI, cURus and FCC. Listed standards include UL62368-1, CSA C22.2 No. 62368-1, ANSI/AAMI ES60601-1 (3.2 version), CAN/CSA-C22.2 No. 60601-1, ANSI/AAMI ES60601-1-11 and CAN/CSA-C22.2 No. 60601-1-11, J62368-1 and CNS15598-1. CB standards cover IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16 and IEC60335-1. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Foldable US AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1200 ±50 mm. Single-unit reference mass 148 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This US version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30E48-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Fixed EU Plug - NGE30E48-P1J

    MEAN WELL NGE30E48-P1J is a 48 V single-output wall-mounted AC/DC adapter rated at 0.63 A and 30 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30E48-P1J Series NGE30 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 48: 48 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 48 V Rated current / current range 0.63 A rated; 0–0.63 A operating range. Rated output power 30 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 91.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery Shutdown and latched output off; re-power on to recover. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 162 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30E24-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Fixed EU Plug - NGE30E24-P1J

    MEAN WELL NGE30E24-P1J is a 24 V single-output wall-mounted AC/DC adapter rated at 1.25 A and 30 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30E24-P1J Series NGE30 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 24: 24 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 24 V Rated current / current range 1.25 A rated; 0–1.25 A operating range. Rated output power 30 W Ripple and noise, maximum 240 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 88.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 162 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30E18-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Fixed EU Plug - NGE30E18-P1J

    MEAN WELL NGE30E18-P1J is an 18 V single-output wall-mounted AC/DC adapter rated at 1.66 A and 30 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30E18-P1J Series NGE30 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 18: 18 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 18 V Rated current / current range 1.66 A rated; 0–1.66 A operating range. Rated output power 30 W Ripple and noise, maximum 180 mVp-p Voltage tolerance ±2.0% Line regulation ±1.0% Load regulation ±2.0% Efficiency, typical 88% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 20 AWG, 1500 ±50 mm. Single-unit reference mass 162 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30E15-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Fixed EU Plug - NGE30E15-P1J

    MEAN WELL NGE30E15-P1J is a 15 V single-output wall-mounted AC/DC adapter rated at 2 A and 30 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30E15-P1J Series NGE30 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 15: 15 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 15 V Rated current / current range 2 A rated; 0–2 A operating range. Rated output power 30 W Ripple and noise, maximum 150 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 87% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 18 AWG, 1500 ±50 mm. Single-unit reference mass 162 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.

  • NGE30E12-P1J

    MEAN WELL NGE30 series: AC/DC Adapter with Fixed EU Plug - NGE30E12-P1J

    MEAN WELL NGE30E12-P1J is a 12 V single-output wall-mounted AC/DC adapter rated at 2.5 A and 30 W. EU version; standard P1J centre-positive DC connector. Apply the input-voltage and ambient-temperature derating limits when selecting the load. Product Datasheet Download MEAN WELL NGE30 Datasheet (PDF) The NGE30 section is on PDF pages 17, 18, 19, 20, 21, 22, 23. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Complete order number NGE30E12-P1J Series NGE30 single-output AC/DC adapter. AC version code E: Fixed, non-folding EU AC pins; non-interchangeable plug. Output code 12: 12 V DC. DC plug code P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length; tuning-fork style, centre positive and outside negative. Class II construction with no earth pin, IP21 enclosure and 94V-0 flame-retardant plastic. Intended applications include consumer electronics, telecommunications, office, industrial, medical and household equipment; choose the approvals and configuration appropriate to the complete equipment. Output ratings DC output voltage 12 V Rated current / current range 2.5 A rated; 0–2.5 A operating range. Rated output power 30 W Ripple and noise, maximum 120 mVp-p Voltage tolerance ±3.0% Line regulation ±1.0% Load regulation ±3.0% Efficiency, typical 88.5% at the specified rated-load test conditions. Keep the load within the rated voltage, current and power limits simultaneously. Output-voltage adjustment is not specified for this fixed-output model. Input and timing Input range 80–264 VAC or 113–370 VDC; 47–63 Hz for AC input. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise / hold-up at full load 1500 / 30 / 30 ms at 230 VAC; 3000 / 30 / 10 ms at 115 VAC. No-load input power <0.075 W. Touch current, maximum <100 µA rms at 264 VAC. Energy-efficiency Level VI. The catalogue lists EISA 2007/DoE, NRCan, Australia/New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5; its design note also states US DoE Level VII against docket EERE-2020-BT-STD-0006. Protection Protection functions Short circuit, overload and overvoltage. Overload threshold 110–150% of rated output power. Overload recovery 5–24V hiccup, automatic recovery after fault removal. Overvoltage 110–140% of rated output voltage; clamped by zener diode. Environment and derating Working temperature −30 to +70°C; apply the load curve. Ambient-temperature curve 100% load from −30 to 45°C; 75% at 60°C; 50% at 70°C. Input-voltage curve At 60 Hz: 80% load at 80 VAC, 100% at 100 VAC, then 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2G, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Use both input-voltage and temperature limits when they apply together. The upper operating temperature does not imply continuous full-load operation. Safety and EMC Construction and isolation Class II; no earth pin. Catalogue identifies 2 x MOPP, BF-rated suitability and limited power source (LPS). Medical-device compliance still requires the complete system to be assessed. Input-to-output withstand 4000 VAC. Input-to-output insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Conducted and radiated Class B: BS EN/EN55032 (CISPR32), EN55011, FCC Part 15, CNS15936, GB/T 9254.1-2021 and KS C 9832. Harmonic current: BS EN/EN61000-3-2 Class A. EU-version certificate panel: CB, DEKRA, EAC and CE. The series safety table lists IEC/BS EN/EN62368-1, IEC/BS EN/EN60601-1/-1-11, IEC/BS EN/EN61558-1/-2-16 and IEC/BS EN/EN60335-1; EAC TPTC004. Use the certificates applicable to the supplied EU version. EMC immunity: BS EN/EN55035 (CISPR35), BS EN/EN60601-1-2 (IEC60601-1-2) and KS C 9835. BS EN/EN61000-4-2: ESD Level 4, 15 kV air / 8 kV contact; -4-3: RF Level 2, 3 V/m; -4-4: EFT Level 3, 2 kV; -4-5: surge Level 3, 1 kV line-to-neutral; -4-6: conducted Level 2, 3 V; -4-8: magnetic field Level 2, 3 A/m; -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruptions for 250 periods. The final equipment must reconfirm whole-system EMC compliance. Mechanical details and cable Main-body dimensions 62 × 30 × 65 mm (L × W × H); case NGE65. Mechanical drawing tolerance ±1 mm; allow space for the version-specific AC pins and cable. AC pins Fixed, non-folding EU AC pins; non-interchangeable plug. Output cable UL1185, 16 AWG, 1200 ±50 mm. Single-unit reference mass 162 g, explicitly listed under main-body PACKING for this version; catalogue packing reference per unit, not a measured net or shipped-package weight. AC connection This EU version has a non-interchangeable AC plug. The separately sold NGE I-type inlet-plug sets are not fitted to this version. Optional DC plugs and quick adapters Selection and supply The P1J connector is standard. Other DC plugs can be ordered as a customized cable with MOQ, or as separately sold quick adapters without MOQ where the table explicitly marks availability. Select one matching output voltage, polarity, geometry and the lowest applicable current rating. Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11.0; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11.0; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/L/M are straight. Quick adapters available, maximum 7.5 A. Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11.0; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11.0; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11.0; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11.0 mm. Values are OD / ID / length. IR/JR/LR/MR are right-angled; I/J/L/M are straight. Customized cable options; no quick adapter listed. Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm. Values are OD / ID / length. SWITCHCRAFT original or equivalent; floating lock. Customized cable options; no quick adapter listed. Mini-pin alternatives P3A: 2.35 / 0.7 / 11.0; P3B: 4.0 / 1.7 / 11.0; P3C: 4.75 / 1.7 / 11.0 mm. Values are OD / ID / length. EIAJ equivalent; quick adapters available, maximum 5 A. Centre-pin alternatives P4A: 5.5 / 3.4 / 11.0 / 1.0; P4B: 6.5 / 4.4 / 11.0 / 1.4; P4C: 7.4 / 5.1 / 11.0 / 0.6 mm. Values are OD / ID / length / centre-pin diameter. EIAJ equivalent; quick adapters available, maximum 7.5 A. R6B locking male mini-DIN KYCON KPPX-3P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: +Vo. Quick adapter available, maximum 7.5 A. R7B locking male mini-DIN KYCON KPPX-4P equivalent. Pin 1: +Vo; pin 2: −Vo; pin 3: −Vo; pin 4: +Vo. Quick adapter available, maximum 7.5 A. Stripped and tinned leads Customized cable: conductor 1 (ribbed) +Vo; conductor 2 (lettered) −Vo. Standard drawing lengths L=25 mm and L1=10 mm; other lengths by request. No quick adapter listed. A quick adapter changes the connection, not the output voltage or the adapter power rating. Keep the load within both the power-supply and connector limits. Reliability and measurement notes MTBF, minimum 1078.6 kh using MIL-HDBK-217F at 25°C; 7587.5 kh using Telcordia TR/SR-332 (Bellcore) at 25°C. Manufacturer warranty Three years, as listed in the manufacturer catalogue. Unless otherwise stated, parameters use 230 VAC, rated load, 25°C and 70% RH. DC voltage is set/measured at the plug terminal at 50% load. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load; load regulation is measured over 0–100% rated load. Refer to the full mechanical drawings and manufacturer installation instructions for the selected plug and cable configuration.


You have seen 72 out of 120 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa