NPF Series, LPF Series: Constant Current & Constant Voltage (C.C. + C.V.) LED Driver , LED Driver , Constant Current LED Driver

190 products

MEAN WELL NPF & LPF Series LED Drivers

MEAN WELL NPF & LPF Series LED Power Supplies

  • Series Comparison
  • Shared Specifications
  • Power Range & Models
  • Dimming & Applications

Series Overview & Comparison

The NPF and LPF series are highly reliable, fully encapsulated LED drivers featuring dual-mode Constant Voltage + Constant Current (CV+CC) outputs. While they share a similar rugged, flame-retardant plastic housing (IP67, Class II), they are optimized for slightly different applications.

  • NPF Series (Flicker-Free): Premium drivers engineered specifically to eliminate light flickering. They feature extremely low standby power consumption (<0.15W) and are favored for high-end indoor, residential, and architectural lighting where visual comfort is paramount.
  • LPF Series (Standard Highly Reliable): The foundational series offering robust environmental protection and up to 91% efficiency. It provides exceptional flexibility for a vast range of general outdoor and indoor LED applications.
  • Dual Mode Operation: Both series output a fixed voltage up to their maximum rated current, seamlessly transitioning into a constant current source to safely drive bare LEDs.

Shared Technical Specifications

Parameter Specification Detail
Input Voltage 90 ~ 305VAC (Universal) / 127 ~ 431VDC
PFC Function Built-in Active PFC, PF > 0.95 at full load
IP Rating IP67 (Fully potted with thermal-conductive silicone)
Electrical Class Class II design (No FG pin), simplifying installation
Protections Short circuit / Over current / Over voltage / Over temperature
Safety Standards UL8750, ENEC EN61347-1, CE, CB, UKCA, EAC

Series Power Range & Availability

Select the series based on your required wattage and output voltage (typically available in 12V, 15V, 20V, 24V, 36V, 42V, 48V, and 54V depending on the model).

Rated Power LPF Series Models NPF Series Models
16W / 25W LPF-16 / LPF-25 N/A
40W / 60W / 90W LPF-40 / LPF-60 / LPF-90 NPF-40 / NPF-60 / NPF-90
120W N/A NPF-120
200W N/A NPF-200 (CV Mode Only)
Note: The "D" suffix (e.g., NPF-90D, LPF-60D) indicates the model includes a built-in dimming function. The NPF-200 series is an exception to the dual-mode design, operating purely in Constant Voltage (CV) mode for high-wattage strip lighting.

Dimming Options & Application Guide

Both series are available in standard (non-dimmable) and dimmable variants to accommodate diverse lighting control systems.

Model Suffix Dimming Feature Best Usage & Controls
Blank
(e.g., NPF-90-24, LPF-60-24)
Non-dimmable Standard fixed lighting, ON/OFF switching setups, outdoor decorative lighting, and commercial signage.
D or V
(e.g., NPF-90D-24, LPF-60D-24)
3-in-1 Dimming Supports 0~10VDC, PWM signal, or resistance dimming. Ideal for smart home integration, automated building systems, and tunable architectural lighting.
Application Tip:

Choose NPF for indoor residential lighting, office LED panels, downlights, and poultry/agricultural lighting where a flicker-free environment is critical for health and visual comfort.
Choose LPF for harsh environments, street lighting, high-bay lighting, greenhouse setups, and general damp/wet locations where robust environmental protection is the primary concern.
  • LPF-40-24

    MEAN WELL LPF-40 series: constant voltage and constant current LED driver - LPF-40-24

    MEAN WELL LPF-40-24 LED Driver The MEAN WELL LPF-40-24 is a constant voltage and constant current LED driver with 24 V rated DC output, 1.67 A rated current and 40.08 W rated power. Its constant current operating region is 14.4-24 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-40 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 88-93; model specifications on page 89. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-40-24 / LPF-40 Model code LPF-40 identifies this series; the final voltage code 24 identifies the 24 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 14.4-24 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 1.67 A or 40.08 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 24 V DC; 1.67 A; 40.08 W. Constant current region 14.4-24 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1000 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 87% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.6 A / 0.3 A / 0.25 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 210 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 20 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 28-35 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; re-power on to recover. Environment and thermal design Parameter Details Case temperature Tcase -40 to +80°C; maximum case temperature +80°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 162.5 x 43 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥60%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 440 g (0.44 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3597.9 thousand hours per Telcordia SR-332 and 438.9 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 75°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-40-20

    MEAN WELL LPF-40 series: constant voltage and constant current LED driver - LPF-40-20

    MEAN WELL LPF-40-20 LED Driver The MEAN WELL LPF-40-20 is a constant voltage and constant current LED driver with 20 V rated DC output, 2 A rated current and 40 W rated power. Its constant current operating region is 12-20 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-40 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 88-93; model specifications on page 89. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-40-20 / LPF-40 Model code LPF-40 identifies this series; the final voltage code 20 identifies the 20 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 12-20 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 2 A or 40 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 20 V DC; 2 A; 40 W. Constant current region 12-20 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±1.0%. Setup / rise time 1000 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.6 A / 0.3 A / 0.25 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 210 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 20 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 23-27 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; re-power on to recover. Environment and thermal design Parameter Details Case temperature Tcase -40 to +80°C; maximum case temperature +80°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 162.5 x 43 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥60%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 440 g (0.44 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3597.9 thousand hours per Telcordia SR-332 and 438.9 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 75°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-40-15

    MEAN WELL LPF-40 series: constant voltage and constant current LED driver - LPF-40-15

    MEAN WELL LPF-40-15 LED Driver The MEAN WELL LPF-40-15 is a constant voltage and constant current LED driver with 15 V rated DC output, 2.67 A rated current and 40.08 W rated power. Its constant current operating region is 9-15 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-40 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 88-93; model specifications on page 89. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-40-15 / LPF-40 Model code LPF-40 identifies this series; the final voltage code 15 identifies the 15 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 9-15 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 2.67 A or 40.08 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 15 V DC; 2.67 A; 40.08 W. Constant current region 9-15 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±1.5%. Setup / rise time 1000 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.6 A / 0.3 A / 0.25 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 210 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 20 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 17.5-21 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; re-power on to recover. Environment and thermal design Parameter Details Case temperature Tcase -40 to +80°C; maximum case temperature +80°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 162.5 x 43 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥60%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 440 g (0.44 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3597.9 thousand hours per Telcordia SR-332 and 438.9 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 75°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-40-12

    MEAN WELL LPF-40 series: constant voltage and constant current LED driver - LPF-40-12

    MEAN WELL LPF-40-12 LED Driver The MEAN WELL LPF-40-12 is a constant voltage and constant current LED driver with 12 V rated DC output, 3.34 A rated current and 40.08 W rated power. Its constant current operating region is 7.2-12 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-40 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 88-93; model specifications on page 89. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-40-12 / LPF-40 Model code LPF-40 identifies this series; the final voltage code 12 identifies the 12 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 7.2-12 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 3.34 A or 40.08 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 12 V DC; 3.34 A; 40.08 W. Constant current region 7.2-12 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±2.0%. Setup / rise time 1000 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 84% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.6 A / 0.3 A / 0.25 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 210 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 20 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 15-17 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; re-power on to recover. Environment and thermal design Parameter Details Case temperature Tcase -40 to +80°C; maximum case temperature +80°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 162.5 x 43 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥60%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 440 g (0.44 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3597.9 thousand hours per Telcordia SR-332 and 438.9 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 75°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-54

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-54

    MEAN WELL LPF-25D-54 LED Driver The MEAN WELL LPF-25D-54 is a dimmable constant current LED driver with 54 V rated DC output, 0.47 A rated current and 25.38 W rated power. Its constant current operating region is 29.7-54 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-54 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 54 identifies the 54 V output version. Output mode and load selection Directly drives a compatible LED load at 0.47 A within 29.7-54 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.47 A or 25.38 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 54 V DC; 0.47 A; 25.38 W. Constant current region 29.7-54 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 59-66 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-48

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-48

    MEAN WELL LPF-25D-48 LED Driver The MEAN WELL LPF-25D-48 is a dimmable constant current LED driver with 48 V rated DC output, 0.53 A rated current and 25.44 W rated power. Its constant current operating region is 26.4-48 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-48 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 48 identifies the 48 V output version. Output mode and load selection Directly drives a compatible LED load at 0.53 A within 26.4-48 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.53 A or 25.44 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 48 V DC; 0.53 A; 25.44 W. Constant current region 26.4-48 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 54-63 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-42

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-42

    MEAN WELL LPF-25D-42 LED Driver The MEAN WELL LPF-25D-42 is a dimmable constant current LED driver with 42 V rated DC output, 0.6 A rated current and 25.2 W rated power. Its constant current operating region is 23.1-42 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-42 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 42 identifies the 42 V output version. Output mode and load selection Directly drives a compatible LED load at 0.6 A within 23.1-42 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.6 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 42 V DC; 0.6 A; 25.2 W. Constant current region 23.1-42 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 46-54 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-36

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-36

    MEAN WELL LPF-25D-36 LED Driver The MEAN WELL LPF-25D-36 is a dimmable constant current LED driver with 36 V rated DC output, 0.7 A rated current and 25.2 W rated power. Its constant current operating region is 19.8-36 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-36 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 36 identifies the 36 V output version. Output mode and load selection Directly drives a compatible LED load at 0.7 A within 19.8-36 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.7 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 36 V DC; 0.7 A; 25.2 W. Constant current region 19.8-36 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 41-49 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-30

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-30

    MEAN WELL LPF-25D-30 LED Driver The MEAN WELL LPF-25D-30 is a dimmable constant current LED driver with 30 V rated DC output, 0.84 A rated current and 25.2 W rated power. Its constant current operating region is 16.5-30 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-30 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 30 identifies the 30 V output version. Output mode and load selection Directly drives a compatible LED load at 0.84 A within 16.5-30 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.84 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 30 V DC; 0.84 A; 25.2 W. Constant current region 16.5-30 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 34-40 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-24

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-24

    MEAN WELL LPF-25D-24 LED Driver The MEAN WELL LPF-25D-24 is a dimmable constant current LED driver with 24 V rated DC output, 1.05 A rated current and 25.2 W rated power. Its constant current operating region is 13.2-24 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-24 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 24 identifies the 24 V output version. Output mode and load selection Directly drives a compatible LED load at 1.05 A within 13.2-24 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 1.05 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 24 V DC; 1.05 A; 25.2 W. Constant current region 13.2-24 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 28-35 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-20

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-20

    MEAN WELL LPF-25D-20 LED Driver The MEAN WELL LPF-25D-20 is a dimmable constant current LED driver with 20 V rated DC output, 1.25 A rated current and 25 W rated power. Its constant current operating region is 11-20 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-20 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 20 identifies the 20 V output version. Output mode and load selection Directly drives a compatible LED load at 1.25 A within 11-20 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 1.25 A or 25 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 20 V DC; 1.25 A; 25 W. Constant current region 11-20 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 23-27 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-15

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-15

    MEAN WELL LPF-25D-15 LED Driver The MEAN WELL LPF-25D-15 is a dimmable constant current LED driver with 15 V rated DC output, 1.67 A rated current and 25.05 W rated power. Its constant current operating region is 8.25-15 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-15 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 15 identifies the 15 V output version. Output mode and load selection Directly drives a compatible LED load at 1.67 A within 8.25-15 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 1.67 A or 25.05 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 15 V DC; 1.67 A; 25.05 W. Constant current region 8.25-15 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 84% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 17.5-21 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25D-12

    MEAN WELL LPF-25D series: dimmable constant current LED driver - LPF-25D-12

    MEAN WELL LPF-25D-12 LED Driver The MEAN WELL LPF-25D-12 is a dimmable constant current LED driver with 12 V rated DC output, 2.1 A rated current and 25.2 W rated power. Its constant current operating region is 6.6-12 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 80-87; model specifications on page 81. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25D-12 / LPF-25D Model code LPF-25D identifies this series; the final voltage code 12 identifies the 12 V output version. Output mode and load selection Directly drives a compatible LED load at 2.1 A within 6.6-12 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 2.1 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 12 V DC; 2.1 A; 25.2 W. Constant current region 6.6-12 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 84% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 15-18 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-54

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-54

    MEAN WELL LPF-25-54 LED Driver The MEAN WELL LPF-25-54 is a constant voltage and constant current LED driver with 54 V rated DC output, 0.47 A rated current and 25.38 W rated power. Its constant current operating region is 29.7-54 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-54 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 54 identifies the 54 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 29.7-54 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 0.47 A or 25.38 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 54 V DC; 0.47 A; 25.38 W. Constant current region 29.7-54 V. Ripple and noise 350 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 59-66 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-48

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-48

    MEAN WELL LPF-25-48 LED Driver The MEAN WELL LPF-25-48 is a constant voltage and constant current LED driver with 48 V rated DC output, 0.53 A rated current and 25.44 W rated power. Its constant current operating region is 26.4-48 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-48 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 48 identifies the 48 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 26.4-48 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 0.53 A or 25.44 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 48 V DC; 0.53 A; 25.44 W. Constant current region 26.4-48 V. Ripple and noise 250 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 87% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 54-63 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-42

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-42

    MEAN WELL LPF-25-42 LED Driver The MEAN WELL LPF-25-42 is a constant voltage and constant current LED driver with 42 V rated DC output, 0.6 A rated current and 25.2 W rated power. Its constant current operating region is 23.1-42 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-42 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 42 identifies the 42 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 23.1-42 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 0.6 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 42 V DC; 0.6 A; 25.2 W. Constant current region 23.1-42 V. Ripple and noise 250 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 46-54 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-36

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-36

    MEAN WELL LPF-25-36 LED Driver The MEAN WELL LPF-25-36 is a constant voltage and constant current LED driver with 36 V rated DC output, 0.7 A rated current and 25.2 W rated power. Its constant current operating region is 19.8-36 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-36 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 36 identifies the 36 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 19.8-36 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 0.7 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 36 V DC; 0.7 A; 25.2 W. Constant current region 19.8-36 V. Ripple and noise 250 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 41-49 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-30

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-30

    MEAN WELL LPF-25-30 LED Driver The MEAN WELL LPF-25-30 is a constant voltage and constant current LED driver with 30 V rated DC output, 0.84 A rated current and 25.2 W rated power. Its constant current operating region is 16.5-30 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-30 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 30 identifies the 30 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 16.5-30 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 0.84 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 30 V DC; 0.84 A; 25.2 W. Constant current region 16.5-30 V. Ripple and noise 200 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 34-40 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-24

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-24

    MEAN WELL LPF-25-24 LED Driver The MEAN WELL LPF-25-24 is a constant voltage and constant current LED driver with 24 V rated DC output, 1.05 A rated current and 25.2 W rated power. Its constant current operating region is 13.2-24 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-24 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 24 identifies the 24 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 13.2-24 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 1.05 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 24 V DC; 1.05 A; 25.2 W. Constant current region 13.2-24 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±0.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 28-35 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-20

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-20

    MEAN WELL LPF-25-20 LED Driver The MEAN WELL LPF-25-20 is a constant voltage and constant current LED driver with 20 V rated DC output, 1.25 A rated current and 25 W rated power. Its constant current operating region is 11-20 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-20 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 20 identifies the 20 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 11-20 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 1.25 A or 25 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 20 V DC; 1.25 A; 25 W. Constant current region 11-20 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±1.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 86% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 23-27 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-15

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-15

    MEAN WELL LPF-25-15 LED Driver The MEAN WELL LPF-25-15 is a constant voltage and constant current LED driver with 15 V rated DC output, 1.67 A rated current and 25.05 W rated power. Its constant current operating region is 8.25-15 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-15 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 15 identifies the 15 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 8.25-15 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 1.67 A or 25.05 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 15 V DC; 1.67 A; 25.05 W. Constant current region 8.25-15 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±1.5%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 17.5-21 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-25-12

    MEAN WELL LPF-25 series: constant voltage and constant current LED driver - LPF-25-12

    MEAN WELL LPF-25-12 LED Driver The MEAN WELL LPF-25-12 is a constant voltage and constant current LED driver with 12 V rated DC output, 2.1 A rated current and 25.2 W rated power. Its constant current operating region is 6.6-12 V. The plastic housing uses Class II insulation and IP67 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-25 Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 74-79; model specifications on page 75. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-25-12 / LPF-25 Model code LPF-25 identifies this series; the final voltage code 12 identifies the 12 V output version. Output mode and load selection Operates in constant current mode for direct LED drive within 6.6-12 V, or in constant voltage mode, usually through an additional DC/DC LED driver. The highest voltage in the current region also depends on the final load configuration. Load limits Do not exceed 2.1 A or 25.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Control configuration Fixed-output non-D configuration; the model wiring diagram has no DIM control pair. Applications LED panel lighting, downlights, decorative lighting, tunnel lighting and moving signs. Output performance Parameter Details Rated output 12 V DC; 2.1 A; 25.2 W. Constant current region 6.6-12 V. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance / regulation Voltage tolerance ±4.0%, including setup, line and load regulation. Line regulation ±0.5%; load regulation ±2.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 84% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 50 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 12 units with type B or 21 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 15-18 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Fully encapsulated IP67 plastic housing; catalog suitability includes dry, damp and wet locations. Provide protected wiring and connections and follow the installation manual. Do not immerse or operate the driver in water. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 5 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJOW 17 AWG x 2 conductors and 05RN-F 2 x 1.0 mm²; 300 ±20 mm. Red = +V, black = -V. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. Connection and mounting items This lead-wired driver requires suitable final-equipment connections and mounting hardware selected for its cable, enclosure and mechanical requirements. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. J61347-1 and J61347-2-13 are also listed for this non-D series. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥50%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 360 g (0.36 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3574.2 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-16D-54

    MEAN WELL LPF-16D series: dimmable constant current LED driver - LPF-16D-54

    MEAN WELL LPF-16D-54 LED Driver The MEAN WELL LPF-16D-54 is a dimmable constant current LED driver with 54 V rated DC output, 0.3 A rated current and 16.2 W rated power. Its constant current operating region is 29.7-54 V. The plastic housing uses Class II insulation and IP30 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-16D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 66-73; model specifications on page 67. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-16D-54 / LPF-16D Model code LPF-16D identifies this series; the final voltage code 54 identifies the 54 V output version. This standard model is IP30. The series offers an optional fully encapsulated IP67 configuration; that option is not implied by the standard model code. Output mode and load selection Directly drives a compatible LED load at 0.3 A within 29.7-54 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.3 A or 16.2 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED downlights, spotlights, decorative lighting and tunnel lighting. Output performance Parameter Details Rated output 54 V DC; 0.3 A; 16.2 W. Constant current region 29.7-54 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 84.5% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 45 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 14 units with type B or 24 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 59-66 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Standard IP30 plastic housing for dry or damp locations; do not assume the optional IP67 configuration is fitted. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 2 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 210 g (0.21 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3572.8 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.

  • LPF-16D-48

    MEAN WELL LPF-16D series: dimmable constant current LED driver - LPF-16D-48

    MEAN WELL LPF-16D-48 LED Driver The MEAN WELL LPF-16D-48 is a dimmable constant current LED driver with 48 V rated DC output, 0.34 A rated current and 16.32 W rated power. Its constant current operating region is 26.4-48 V. The plastic housing uses Class II insulation and IP30 protection, with active PFC and free-air convection cooling. Download MEAN WELL LPF-16D Datasheet (PDF) Download MEAN WELL LED Installation Manual (PDF) Catalog pages 66-73; model specifications on page 67. Temperature, dimming and wiring conditions below apply to this model. Model selection Parameter Details Full model / series LPF-16D-48 / LPF-16D Model code LPF-16D identifies this series; the final voltage code 48 identifies the 48 V output version. This standard model is IP30. The series offers an optional fully encapsulated IP67 configuration; that option is not implied by the standard model code. Output mode and load selection Directly drives a compatible LED load at 0.34 A within 26.4-48 V. Use the D-type dimming interface below; this driver is not suitable for use with an additional LED driver. Load limits Do not exceed 0.34 A or 16.32 W; apply input and temperature derating. Use the actual rated power, not the series number, for load sizing. Applications LED downlights, spotlights, decorative lighting and tunnel lighting. Output performance Parameter Details Rated output 48 V DC; 0.34 A; 16.32 W. Constant current region 26.4-48 V. Current ripple / tolerance Maximum current ripple: 5.0% at rated current. Current tolerance: ±5.0%. Setup / rise time 1500 ms / 80 ms at 115 VAC; 500 ms / 80 ms at 230 VAC. Setup is measured at the first cold start; repeated switching can increase setup time. Hold-up time 16 ms typical at 115 VAC and 230 VAC. Efficiency and measurement conditions 85% typical. Unless specifically stated otherwise, specifications are measured at 230 VAC, rated current and 25°C ambient. Typical values are not guarantees at every operating point. Input and electrical limits Parameter Details Input range / frequency 90-305 VAC or 127-431 VDC; 47-63 Hz AC. Apply the low-input derating curve; full input-range availability does not imply full load at the lowest voltage. Low-input derating The 60 Hz static characteristic shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 305 VAC, subject to temperature limits. AC current 0.4 A / 0.25 A / 0.2 A at 115 / 230 / 277 VAC respectively. Power factor At full load: PF ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC. Total harmonic distortion THD <20% at load ≥60% with 115/230 VAC, or load ≥75% with 277 VAC. Refer to the model curves for behavior at other loads. Inrush current 45 A typical cold start at 230 VAC; pulse width 200 µs measured at 50% peak current, per the catalog NEMA 410 reference. Circuit-breaker reference Maximum catalog quantity at 230 VAC on a 16 A breaker: 14 units with type B or 24 with type C. Coordinate the complete circuit and inrush conditions. Leakage current <0.75 mA at 240 VAC. Protection Parameter Details Overcurrent 95-108% of rated output current; constant current limiting, with automatic recovery after the fault is removed. Short circuit / low output voltage Hiccup mode; automatic recovery after fault removal. Overvoltage 54-63 V; output shutdown and latch-off; re-power on to recover. Overtemperature Output shutdown; automatic recovery after temperature falls. Dimming and external controls Parameter Details 3-in-1 interface Adjust the constant current level between DIM+ and DIM- using one of: additive 1-10 VDC, a 10 V PWM signal, or resistance. Typical dimming source current from the driver is 100 µA. Analog voltage The plotted range is 1-10 VDC for 10-100% output current. PWM control Use a 10 V PWM signal at 100 Hz-3 kHz. The plotted duty-cycle range is 10-100%, corresponding to 10-100% output current. Resistance control The plotted range is 10 kΩ/N to 100 kΩ/N for 10-100% current, where N is the number of drivers operated synchronously. For one driver this is 10-100 kΩ. Wiring and isolation DIM+ is purple; DIM- is pink. Do not connect DIM- to -V. The installation manual states that LPF dimming circuitry is not isolated from the secondary output; use a compatible controller. Zero-brightness switching Do not treat the 10% dimming endpoint as OFF. For 0% brightness, the catalog uses an external switch and relay to turn the lighting fixture on/off, or directs the installer to MEAN WELL for other options. Environment and thermal design Parameter Details Case temperature Tcase -35 to +70°C; maximum case temperature +70°C. These are case-temperature limits, not ambient ratings. Measure at the tc point shown in the mechanical drawing. Ambient temperature and derating Horizontal installation: ambient load curve shows 100% through +50°C, then a linear decrease to 60% at +70°C. Keep the case measurement point within the separate Tcase limit. Cooling / orientation Fanless, free-air convection. Mount in the horizontal direction shown in the mechanical drawing. Nonstandard orientation or elevated ambient temperature requires output-current derating. Ingress protection Standard IP30 plastic housing for dry or damp locations; do not assume the optional IP67 configuration is fitted. Humidity / storage Operating humidity: 20-95% RH, non-condensing. Storage: -40 to +80°C and 10-95% RH. Altitude For this fanless driver, reduce the ambient-temperature limit by 3.5°C per 1000 m above 2000 m altitude. Temperature coefficient / vibration ±0.03%/°C over 0-50°C. Vibration: 10-500 Hz, 2 G; 12 min/cycle, 72 min on each X, Y and Z axis. Dimensions, wiring and installation Parameter Details Dimensions / mounting 148 x 40 x 32 mm (L x W x H), drawing tolerance ±1 mm. Two Ø3.6 mm mounting features; locate the hardware from the model drawing. Input cable SJOW 17 AWG x 2 conductors and H05RN-F 2 x 1.0 mm²; 300 ±20 mm. Brown = AC/L, blue = AC/N. Output cable SJTW 18 AWG x 4 conductors; 300 ±20 mm. Red = +V, black = -V, purple = DIM+, pink = DIM-. Insulation / grounding Class II plastic housing with no FG lead shown. Class II insulation and Class 2 power-unit classification are different characteristics. Installation clearances Disconnect the utility before installation or maintenance and prevent unintended reconnection. Keep ventilation clear and do not stack objects on the unit. Maintain 10-15 cm clearance when an adjacent device is a heat source. Cable and system protection Use approved primary and secondary cables rated at least for the driver current. Provide system-level insulation/isolation around interconnections, and enclose single-insulated wires. Where waterproof connectors are used, ensure a tight linkage that prevents water entering the system. ErP installation condition To meet the datasheet condition for the latest lighting-fixture ErP requirements, use this driver behind a switch; do not keep it permanently connected to the mains. BSMI integration condition For BSMI certification when connecting peripheral equipment, the LED installation manual requires LPF series to be installed with a fireproof enclosure rated V1 or higher. Servicing Do not remove the case yourself. Faults must be examined by a qualified technician. Damaged external flexible cable must be replaced by the manufacturer, its service agent or a similarly qualified person. External control items Select a compatible dimming controller and, when full OFF is required, the switch/relay arrangement in the catalog. These are system-level connection items; the diagram does not identify a supplied accessory set or dedicated order codes. Standards and catalog references Parameter Details Listed safety references UL 8750; CSA C22.2 No. 250.0-08; ENEC BS EN/EN 61347-1 and BS EN/EN 61347-2-13 independent; BS EN/EN 62384; EAC TP TC 004; GB/T 19510.1 and GB/T 19510.213. The listed IP rating applies to the selected housing configuration; UL 60950-1 is a design reference, not listed as an approval. Classifications Class II insulation, Class 2 power unit and SELV are identified in the catalog. Withstand / insulation resistance Input-to-output withstand: 3.75 kVAC. Input-to-output insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at load ≥55%; BS EN/EN 61000-3-3; GB/T 17743; GB 17625.1; EAC TP TC 020. EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN 61547, light-industry level; line-to-line surge immunity 2 kV; EAC TP TC 020. System assessment This is a component power supply. The final equipment manufacturer must re-qualify EMC for the complete installation; wiring, load and enclosure affect system performance. Catalog unit mass 210 g (0.21 kg) per unit from the PACKING field: catalog packing reference per unit, not a measured net weight or total shipping-package weight. Reliability / service-life references Minimum MTBF: 3572.8 thousand hours per Telcordia SR-332 and 391.6 thousand hours per MIL-HDBK-217F at 25°C. The catalog states typical life expectancy >50,000 hours at tc about 70°C or less. Life curves depend on case temperature; these are not guaranteed service-life values. Manufacturer warranty reference The manufacturer datasheet lists a five-year warranty; the manufacturer warranty statement defines its terms.


You have seen 72 out of 190 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa