XLG Series: Constant Power DALI-2 LED Driver

56 products

  • Series Overview
  • Technical Highlights
  • Power Range & Output Types
  • Dimming & Control Options

MEAN WELL XLG Series Metal-Case LED Drivers

The XLG series is a highly reliable, heavy-duty LED driver housed in a rugged metal case. It is defined by its cutting-edge Constant Power (CP) mode design, which allows a single driver to deliver its full rated wattage across a very wide range of output currents and voltages, drastically reducing the number of SKU models needed in inventory.

  • Rugged Metal Housing: Built with a robust metal enclosure and fully potted with thermal-conductive silicone, offering superior heat dissipation and extreme durability.
  • IP67 Waterproof Rating: Completely protected against dust and water immersion, making it ideal for harsh outdoor, wet, and industrial environments.
  • Constant Power Architecture: The driver automatically adjusts the output voltage according to the connected LED load while maintaining a constant power output, maximizing fixture compatibility.
  • Compact Design: Compared to older generations of metal-case drivers (like the ELG series), the XLG series features a highly condensed footprint (up to 30% smaller), saving installation space and reducing shipping costs.

Technical Highlights

  • Wide Input Range: Operates on a universal AC input from 100~305VAC, suitable for both standard commercial grids and high-line industrial voltages.
  • High Surge Protection: Engineered with robust internal surge immunity (typically 6KV/4KV, and up to 10KV/6KV on higher wattages), which is critical for outdoor street and flood lighting reliability.
  • Active PFC: Built-in Active Power Factor Correction ensures high efficiency (up to 94%) and compliance with stringent harmonic current regulations (EN61000-3-2 Class C).
  • Comprehensive Protections: Fully equipped with auto-recovery safeguards against short circuit, over-voltage, and over-temperature.
  • Global Safety Certifications: UL, ENEC, TUV, CE, CB, UKCA, and EAC approvals ensure readiness for major international lighting projects.

Power Range & Output Variants

The XLG series covers a massive wattage spectrum, ranging from 20W all the way up to 320W, and is split into specific output types based on your application needs:

Available Wattages Output Types Ideal Applications
20W, 25W, 50W, 75W, 100W, 150W, 200W, 240W, 320W L / M / H Types (Constant Power)
Provides a wide adjustable current range across Low, Medium, or High voltage bands.
Street lights, high-bay lights, stadium floodlights, horticulture lighting, and general architectural outdoor lighting.
12V / 24V Types (CV + CC)
Fixed voltage output with constant current limiting capability.
Outdoor LED strips, commercial signage, moving signs, and low-voltage architectural landscape lighting.
Design Tip: By selecting the Constant Power (L/M/H) models, lighting manufacturers can use the exact same XLG driver to power entirely different LED COBs or PCB arrays simply by tuning the output current to match the load.

Dimming & Control Options

To accommodate various smart city and project specifications, the XLG series is available with multiple functional suffixes:

Suffix Code Feature Description
Blank Type Standard version without dimming functionality. Features a fixed output. IP67 rated.
A-Type Features an internal potentiometer accessed via a waterproof rubber plug, allowing manual adjustment of the output current (Io). IP67 rated.
AB-Type Combines the manual current adjustment of the A-Type with a built-in 3-in-1 Dimming function (0~10VDC, 10V PWM signal, or resistance). IP67 rated.
DA2-Type Integrated with DALI-2 digital control for smart, addressable outdoor lighting networks. IP67 rated.
  • XLG-75I-H-DA2

    MEAN WELL XLG-75-DA2 series: DALI-2 Constant-Power LED Driver - XLG-75I-H-DA2

    XLG-75I-H-DA2 LED driver MEAN WELL XLG-75I-H-DA2 is a 75.6 W constant-power AC/DC LED driver in the XLG-75-DA2 series. It provides a 1400 mA rated output, a 27–56 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. India (EESL) version with input overvoltage protection, available by request. Download MEAN WELL XLG-75-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 7–12; XLG-75-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-75I-H-DA2 / XLG-75-DA2; H output type; India (EESL) version with input overvoltage protection, available by request. Rated power / current 75.6 W / 1400 mA Constant-current region 27–56 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 1300–2100 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 60 V Output-current adjustment 700–2100 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 700 mA/56 V; 1300 mA/56 V; 2100 mA/36 V; 2100 mA/27 V; 1300 mA/27 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation The series feature describes full-power operation over 70–100% of its constant-power region; use the exact model current and I–V limits above. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power The <0.5 W dimming-off figure is specified only for the standard version; it is not assigned to this India version. Input and electrical performance Input range / frequency 100–305 VAC / 142–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 1 A / 0.45 A / 0.38 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 360 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 8 units on type B / 14 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits 100% load across 100–305 VAC, subject to the separate thermal and operating-region limits. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-75-L-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection 320–390 VAC protection range for this India version: shuts down output when input exceeds the protection threshold and automatically recovers after the fault is removed. The 440 VAC / 48-hour withstand statement is a fault-stress capability, not the normal operating-input range. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +90°C; maximum case temperature +90°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 90°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH non-condensing. Storage −40 to +80°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2489.3 K hours minimum, Telcordia SR-332 (Bellcore); 245.7 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing, Class I construction with protective-earth/FG connection. Follow the installation manual and the specified mounting direction. Output classification H-type SELV output; Class 2 power unit. Applicable safety standards The India version is without UL/CSA certification. IS 15885 (Part 2/Sec 13) applies to this I version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application The series application refers to Class I, Division 2 and requires consideration of built-in use. This India version has no UL/CSA certificate; do not treat the series-level Type HL statement as UL certification of this SKU or a complete luminaire. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 140 × 63 × 32 mm (L × W × H), case 275A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 134 mm longitudinal and 40 mm transverse fixing spacing; 125 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 57 mm from the drawing’s right-hand reference and 24 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 39.7 mm and 12.7 mm. Unit weight 0.58 kg (580 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 15 kg / 0.85 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Skyscraper, street, flood, stage, fishing, horticulture and bay lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-75I-L-DA2

    MEAN WELL XLG-75-DA2 series: DALI-2 Constant-Power LED Driver - XLG-75I-L-DA2

    XLG-75I-L-DA2 LED driver MEAN WELL XLG-75I-L-DA2 is a 74.9 W constant-power AC/DC LED driver in the XLG-75-DA2 series. It provides a 700 mA rated output, a 53–107 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. India (EESL) version with input overvoltage protection, available by request. Download MEAN WELL XLG-75-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 7–12; XLG-75-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-75I-L-DA2 / XLG-75-DA2; L output type; India (EESL) version with input overvoltage protection, available by request. Rated power / current 74.9 W / 700 mA Constant-current region 53–107 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 700–1050 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 115 V Output-current adjustment 350–1050 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 350 mA/107 V; 700 mA/107 V; 1050 mA/71 V; 1050 mA/53 V; 700 mA/53 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation The series feature describes full-power operation over 70–100% of its constant-power region; use the exact model current and I–V limits above. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power The <0.5 W dimming-off figure is specified only for the standard version; it is not assigned to this India version. Input and electrical performance Input range / frequency 100–305 VAC / 142–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 1 A / 0.45 A / 0.38 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 360 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 8 units on type B / 14 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits 100% load across 100–305 VAC, subject to the separate thermal and operating-region limits. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-75-L-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection 320–390 VAC protection range for this India version: shuts down output when input exceeds the protection threshold and automatically recovers after the fault is removed. The 440 VAC / 48-hour withstand statement is a fault-stress capability, not the normal operating-input range. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +90°C; maximum case temperature +90°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 90°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH non-condensing. Storage −40 to +80°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2489.3 K hours minimum, Telcordia SR-332 (Bellcore); 245.7 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing, Class I construction with protective-earth/FG connection. Follow the installation manual and the specified mounting direction. Output classification The XLG-75-DA2 cover carries the SELV marking without an L-type exclusion. The separate Class 2 power-unit feature explicitly excludes L type; do not assign Class 2 to this model. Applicable safety standards The India version is without UL/CSA certification. IS 15885 (Part 2/Sec 13) applies to this I version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application The series application refers to Class I, Division 2 and requires consideration of built-in use. This India version has no UL/CSA certificate; do not treat the series-level Type HL statement as UL certification of this SKU or a complete luminaire. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 140 × 63 × 32 mm (L × W × H), case 275A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 134 mm longitudinal and 40 mm transverse fixing spacing; 125 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 57 mm from the drawing’s right-hand reference and 24 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 39.7 mm and 12.7 mm. Unit weight 0.58 kg (580 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 15 kg / 0.85 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Skyscraper, street, flood, stage, fishing, horticulture and bay lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-75-H-DA2

    MEAN WELL XLG-75-DA2 series: DALI-2 Constant-Power LED Driver - XLG-75-H-DA2

    XLG-75-H-DA2 LED driver MEAN WELL XLG-75-H-DA2 is a 75.6 W constant-power AC/DC LED driver in the XLG-75-DA2 series. It provides a 1400 mA rated output, a 27–56 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. Standard version. Download MEAN WELL XLG-75-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 7–12; XLG-75-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-75-H-DA2 / XLG-75-DA2; H output type; Standard version. Rated power / current 75.6 W / 1400 mA Constant-current region 27–56 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 1300–2100 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 60 V Output-current adjustment 700–2100 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 700 mA/56 V; 1300 mA/56 V; 2100 mA/36 V; 2100 mA/27 V; 1300 mA/27 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation The series feature describes full-power operation over 70–100% of its constant-power region; use the exact model current and I–V limits above. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power <0.5 W with dimming OFF, for the standard version. Input and electrical performance Input range / frequency 100–305 VAC / 142–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 1 A / 0.45 A / 0.38 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 360 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 8 units on type B / 14 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits 100% load across 100–305 VAC, subject to the separate thermal and operating-region limits. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-75-L-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection The input-overvoltage protection and 440 VAC / 48-hour stress capability apply only to the India I version and are not assigned to this standard model. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +90°C; maximum case temperature +90°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 90°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH non-condensing. Storage −40 to +80°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2489.3 K hours minimum, Telcordia SR-332 (Bellcore); 245.7 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing, Class I construction with protective-earth/FG connection. Follow the installation manual and the specified mounting direction. Output classification H-type SELV output; Class 2 power unit. Applicable safety standards UL 8750 Type HL and CSA C22.2 No. 250.13-12 apply to the standard version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application Type HL use in Class I, Division 2 requires consideration of built-in installation. The driver is a component; suitability of the complete luminaire must be established. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 140 × 63 × 32 mm (L × W × H), case 275A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 134 mm longitudinal and 40 mm transverse fixing spacing; 125 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 57 mm from the drawing’s right-hand reference and 24 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 39.7 mm and 12.7 mm. Unit weight 0.58 kg (580 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 15 kg / 0.85 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Skyscraper, street, flood, stage, fishing, horticulture and bay lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-75-L-DA2

    MEAN WELL XLG-75-DA2 series: DALI-2 Constant-Power LED Driver - XLG-75-L-DA2

    XLG-75-L-DA2 LED driver MEAN WELL XLG-75-L-DA2 is a 74.9 W constant-power AC/DC LED driver in the XLG-75-DA2 series. It provides a 700 mA rated output, a 53–107 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. Standard version. Download MEAN WELL XLG-75-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 7–12; XLG-75-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-75-L-DA2 / XLG-75-DA2; L output type; Standard version. Rated power / current 74.9 W / 700 mA Constant-current region 53–107 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 700–1050 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 115 V Output-current adjustment 350–1050 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 350 mA/107 V; 700 mA/107 V; 1050 mA/71 V; 1050 mA/53 V; 700 mA/53 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation The series feature describes full-power operation over 70–100% of its constant-power region; use the exact model current and I–V limits above. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power <0.5 W with dimming OFF, for the standard version. Input and electrical performance Input range / frequency 100–305 VAC / 142–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 1 A / 0.45 A / 0.38 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 360 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 8 units on type B / 14 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits 100% load across 100–305 VAC, subject to the separate thermal and operating-region limits. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-75-L-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection The input-overvoltage protection and 440 VAC / 48-hour stress capability apply only to the India I version and are not assigned to this standard model. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +90°C; maximum case temperature +90°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 90°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH non-condensing. Storage −40 to +80°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2489.3 K hours minimum, Telcordia SR-332 (Bellcore); 245.7 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing, Class I construction with protective-earth/FG connection. Follow the installation manual and the specified mounting direction. Output classification The XLG-75-DA2 cover carries the SELV marking without an L-type exclusion. The separate Class 2 power-unit feature explicitly excludes L type; do not assign Class 2 to this model. Applicable safety standards UL 8750 Type HL and CSA C22.2 No. 250.13-12 apply to the standard version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application Type HL use in Class I, Division 2 requires consideration of built-in installation. The driver is a component; suitability of the complete luminaire must be established. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 140 × 63 × 32 mm (L × W × H), case 275A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 134 mm longitudinal and 40 mm transverse fixing spacing; 125 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 57 mm from the drawing’s right-hand reference and 24 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 39.7 mm and 12.7 mm. Unit weight 0.58 kg (580 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 15 kg / 0.85 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Skyscraper, street, flood, stage, fishing, horticulture and bay lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-50I-H-DA2

    MEAN WELL XLG-50-DA2 series: DALI-2 Constant-Power LED Driver - XLG-50I-H-DA2

    XLG-50I-H-DA2 LED driver MEAN WELL XLG-50I-H-DA2 is a 50 W constant-power AC/DC LED driver in the XLG-50-DA2 series. It provides a 1050 mA rated output, a 27–56 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. India (EESL) version with input overvoltage protection, available by request. Download MEAN WELL XLG-50-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 1–6; XLG-50-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-50I-H-DA2 / XLG-50-DA2; H output type; India (EESL) version with input overvoltage protection, available by request. Rated power / current 50 W / 1050 mA Constant-current region 27–56 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 900–1400 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 60 V Output-current adjustment 500–1400 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 500 mA/56 V; 900 mA/56 V; 1400 mA/36 V; 1400 mA/27 V; 900 mA/27 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation Full-power operation uses the specified 900–1400 mA current range within this model’s I–V envelope. Observe the rated power and all input-voltage and temperature limits. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power The <0.5 W dimming-off figure is specified only for the standard version; it is not assigned to this India version. Input and electrical performance Input range / frequency 90–305 VAC / 127–431 VDC / 47–63 Hz. Typical efficiency 89% at the model-specific specification conditions. The datasheet states that efficiency drops 1% for the India version; the quoted table figure is the standard reference. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 0.57 A / 0.29 A / 0.24 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 350 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 7 units on type B / 12 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits about 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 305 VAC. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-50-H-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection 320–370 VAC protection range for this India version: shuts down output when input exceeds the protection threshold and automatically recovers after the fault is removed. The 440 VAC / 48-hour withstand statement is a fault-stress capability, not the normal operating-input range. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +85°C; maximum case temperature +85°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 85°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH. Storage −40 to +80°C. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2352.4 K hours minimum, Telcordia SR-332 (Bellcore); 207.3 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing with functional ground and the protective-earth/FG connection shown in the wiring diagram. Follow the installation manual and the specified mounting direction. Output classification H-type SELV output; Class 2 power unit. Applicable safety standards The India version is without UL/CSA certification. IS 15885 (Part 2/Sec 13) applies to this I version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. AS/NZS IEC / AS/NZS standards are also listed in the 50 W safety table. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application The series application refers to Class I, Division 2 and requires consideration of built-in use. This India version has no UL/CSA certificate; do not treat the series-level Type HL statement as UL certification of this SKU or a complete luminaire. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 105 × 63 × 30 mm (L × W × H), case 268A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 99 mm longitudinal and 40 mm transverse fixing spacing; 90 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 61.3 mm from the drawing’s right-hand reference and 31.6 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 25.8 mm and 9.9 mm. Unit weight 0.42 kg (420 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 11 kg / 0.81 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Street, architectural, bay and flood lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-50I-L-DA2

    MEAN WELL XLG-50-DA2 series: DALI-2 Constant-Power LED Driver - XLG-50I-L-DA2

    XLG-50I-L-DA2 LED driver MEAN WELL XLG-50I-L-DA2 is a 50 W constant-power AC/DC LED driver in the XLG-50-DA2 series. It provides a 700 mA rated output, a 60–142 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. India (EESL) version with input overvoltage protection, available by request. Download MEAN WELL XLG-50-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 1–6; XLG-50-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-50I-L-DA2 / XLG-50-DA2; L output type; India (EESL) version with input overvoltage protection, available by request. Rated power / current 50 W / 700 mA Constant-current region 60–142 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 350–700 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 160 V Output-current adjustment 300–700 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 300 mA/142 V; 350 mA/142 V; 700 mA/72 V; 700 mA/60 V; 350 mA/60 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation Full-power operation uses the specified 350–700 mA current range within this model’s I–V envelope. Observe the rated power and all input-voltage and temperature limits. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power The <0.5 W dimming-off figure is specified only for the standard version; it is not assigned to this India version. Input and electrical performance Input range / frequency 90–305 VAC / 127–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. The datasheet states that efficiency drops 1% for the India version; the quoted table figure is the standard reference. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 0.57 A / 0.29 A / 0.24 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 350 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 7 units on type B / 12 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits about 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 305 VAC. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-50-H-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection 320–370 VAC protection range for this India version: shuts down output when input exceeds the protection threshold and automatically recovers after the fault is removed. The 440 VAC / 48-hour withstand statement is a fault-stress capability, not the normal operating-input range. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +85°C; maximum case temperature +85°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 85°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH. Storage −40 to +80°C. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2352.4 K hours minimum, Telcordia SR-332 (Bellcore); 207.3 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing with functional ground and the protective-earth/FG connection shown in the wiring diagram. Follow the installation manual and the specified mounting direction. Output classification L output type: do not apply the H-type SELV/Class 2 claims to this higher-voltage output. Applicable safety standards The India version is without UL/CSA certification. IS 15885 (Part 2/Sec 13) applies to this I version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. AS/NZS IEC / AS/NZS standards are also listed in the 50 W safety table. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary for L type; it meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. Type HL application The series application refers to Class I, Division 2 and requires consideration of built-in use. This India version has no UL/CSA certificate; do not treat the series-level Type HL statement as UL certification of this SKU or a complete luminaire. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 105 × 63 × 30 mm (L × W × H), case 268A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 99 mm longitudinal and 40 mm transverse fixing spacing; 90 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 61.3 mm from the drawing’s right-hand reference and 31.6 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 25.8 mm and 9.9 mm. Unit weight 0.42 kg (420 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 11 kg / 0.81 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Street, architectural, bay and flood lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-50-H-DA2

    MEAN WELL XLG-50-DA2 series: DALI-2 Constant-Power LED Driver - XLG-50-H-DA2

    XLG-50-H-DA2 LED driver MEAN WELL XLG-50-H-DA2 is a 50 W constant-power AC/DC LED driver in the XLG-50-DA2 series. It provides a 1050 mA rated output, a 27–56 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. Standard version. Download MEAN WELL XLG-50-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 1–6; XLG-50-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-50-H-DA2 / XLG-50-DA2; H output type; Standard version. Rated power / current 50 W / 1050 mA Constant-current region 27–56 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 900–1400 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 60 V Output-current adjustment 500–1400 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 500 mA/56 V; 900 mA/56 V; 1400 mA/36 V; 1400 mA/27 V; 900 mA/27 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation Full-power operation uses the specified 900–1400 mA current range within this model’s I–V envelope. Observe the rated power and all input-voltage and temperature limits. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power <0.5 W with dimming OFF, for the standard version. Input and electrical performance Input range / frequency 90–305 VAC / 127–431 VDC / 47–63 Hz. Typical efficiency 89% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 0.57 A / 0.29 A / 0.24 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 350 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 7 units on type B / 12 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits about 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 305 VAC. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-50-H-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection The input-overvoltage protection and 440 VAC / 48-hour stress capability apply only to the India I version and are not assigned to this standard model. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +85°C; maximum case temperature +85°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 85°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH. Storage −40 to +80°C. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2352.4 K hours minimum, Telcordia SR-332 (Bellcore); 207.3 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing with functional ground and the protective-earth/FG connection shown in the wiring diagram. Follow the installation manual and the specified mounting direction. Output classification H-type SELV output; Class 2 power unit. Applicable safety standards UL 8750 Type HL and CSA C22.2 No. 250.13-12 apply to the standard version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. AS/NZS IEC / AS/NZS standards are also listed in the 50 W safety table. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary. Non-IC classification independent LED control gear is not suitable for residential installations. Type HL application Type HL use in Class I, Division 2 requires consideration of built-in installation. The driver is a component; suitability of the complete luminaire must be established. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 105 × 63 × 30 mm (L × W × H), case 268A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 99 mm longitudinal and 40 mm transverse fixing spacing; 90 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 61.3 mm from the drawing’s right-hand reference and 31.6 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 25.8 mm and 9.9 mm. Unit weight 0.42 kg (420 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 11 kg / 0.81 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Street, architectural, bay and flood lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

  • XLG-50-L-DA2

    MEAN WELL XLG-50-DA2 series: DALI-2 Constant-Power LED Driver - XLG-50-L-DA2

    XLG-50-L-DA2 LED driver MEAN WELL XLG-50-L-DA2 is a 50 W constant-power AC/DC LED driver in the XLG-50-DA2 series. It provides a 700 mA rated output, a 60–142 V constant-current operating region, built-in current adjustment and isolated DALI-2 dimming. The fanless metal enclosure is IP67. Standard version. Download MEAN WELL XLG-50-DA2 Datasheet (PDF)Download MEAN WELL LED Installation Manual XLG-DA2 catalog, PDF pages 1–6; XLG-50-DA2 specification dated 2026-02-04. Use the exact output and function suffix when selecting the driver. Output and exact model Exact model / family XLG-50-L-DA2 / XLG-50-DA2; L output type; Standard version. Rated power / current 50 W / 700 mA Constant-current region 60–142 V; the LED operating point must remain in the shaded I–V envelope. Full-power current range 350–700 mA; constant-power operation within the specified envelope, subject to temperature and input-voltage derating. Maximum open-circuit voltage 160 V Output-current adjustment 300–700 mA via built-in potentiometer; adjustment and full-power ranges are different. Current ripple / tolerance 5.0% at full load / ±5%; tolerance includes setup, line regulation and load regulation. I–V selection boundaries 300 mA/142 V; 350 mA/142 V; 700 mA/72 V; 700 mA/60 V; 350 mA/60 V. These plotted boundary coordinates are rounded reference points; select within the shaded region and rated power, not an unrestricted voltage/current rectangle. Nominal constant-power operation Full-power operation uses the specified 350–700 mA current range within this model’s I–V envelope. Observe the rated power and all input-voltage and temperature limits. Auxiliary output This exact 50–100 W DA2 model has no specified 12 V/250 mA auxiliary output. That option belongs to the DA2-A versions in the 150–320 W families. DALI-2 control Control interface DALI-2 control between DA+ (purple) and DA− (pink), with 16 groups and 64 addresses. The first dimming step is fixed at 8% of output. Protocol IEC 62386-101, -102, -207 and -251; device type 6 (DT6). Output and dimming circuitry use isolation as described in the datasheet. Setup time 500 ms at 230 VAC; 1200 ms at 115 VAC, measured at the first cold start. Repeated ON/OFF switching can increase the setup time. DALI startup condition IEC 62386-101/102 timing and interruption testing requires a DALI controller supporting the DALI power-on function; otherwise setup may exceed 500 ms. Standby power <0.5 W with dimming OFF, for the standard version. Input and electrical performance Input range / frequency 90–305 VAC / 127–431 VDC / 47–63 Hz. Typical efficiency 90% at the model-specific specification conditions. Power factor ≥0.97 at 115 VAC, ≥0.95 at 230 VAC and ≥0.92 at 277 VAC, at full load. THD <10% at ≥50% load for 115/230 VAC, and ≥75% load for 277 VAC. AC input current 0.57 A / 0.29 A / 0.24 A at 115 / 230 / 277 VAC respectively. Cold-start inrush 50 A, 350 μs pulse width measured at 50% of peak, at 230 VAC; per NEMA 410. 16 A circuit-breaker loading 7 units on type B / 12 units on type C at 230 VAC. Leakage current <0.75 mA at 277 VAC. Input-voltage derating At 60 Hz, the static graph permits about 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 305 VAC. Typical-curve conditions PF is plotted in constant-current mode at Tcase 75°C. THD and efficiency graphs use XLG-50-H-DA2 at Tcase 75°C and 115/230/277 VAC; these are typical curves, not additional guaranteed ratings. Switching-frequency references PFC 50–120 kHz; PWM 65 kHz. Protection Short-circuit protection Hiccup mode or constant-current limiting; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces output to 75% loading; stage 2 reduces output to 50% loading. Operation recovers automatically after the fault condition is removed. Input-overvoltage protection The input-overvoltage protection and 440 VAC / 48-hour stress capability apply only to the India I version and are not assigned to this standard model. Surge immunity 4 kV line-to-line / 6 kV line-to-earth; BS EN/EN 61000-4-5. Temperature and reliability Case temperature Tcase −40 to +85°C; maximum case temperature +85°C. Case-temperature ratings are separate from ambient-temperature limits. Ambient-temperature derating Horizontal mounting with free-air convection: at 230 VAC, 100% load through Ta 60°C, reducing to 60% at Ta 70°C; at 100 VAC, 100% through Ta 50°C, reducing to 60% at Ta 60°C. The curves end at those limits; do not extrapolate them. Cold operation The −40 to −30°C portion is specified for 230 VAC input only. Below 120 VAC at −30°C, restarting may occur within 5 seconds after power-on. Case-temperature load curve The horizontal-mounting curve maintains 100% load to Tcase 85°C and ends there; it does not extend the ambient-temperature range. Working humidity 20–95% RH. Storage −40 to +80°C. Temperature coefficient ±0.03%/°C over 0–60°C. Vibration 10–500 Hz, 5 G; 12 minutes per cycle, 72 minutes on each X, Y and Z axis. Altitude derating Above 2000 m (6500 ft), reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless model. Life expectancy / warranty Typical operating life >50,000 hours when the tc point (TMP per DLC) is about 75°C or below; 5-year warranty subject to MEAN WELL terms. The lifetime graph is a temperature-dependent estimate, not an extension of the warranty. MTBF 2352.4 K hours minimum, Telcordia SR-332 (Bellcore); 207.3 K hours minimum, MIL-HDBK-217F at 25°C. Safety and EMC Enclosure and grounding IP67 metal housing with functional ground and the protective-earth/FG connection shown in the wiring diagram. Follow the installation manual and the specified mounting direction. Output classification L output type: do not apply the H-type SELV/Class 2 claims to this higher-voltage output. Applicable safety standards UL 8750 Type HL and CSA C22.2 No. 250.13-12 apply to the standard version. ENEC BS EN/EN 61347-1 and 61347-2-13, BS EN/EN 62384, GB/T 19510.1 and 19510.213, EAC TP TC 004; IP67. AS/NZS IEC / AS/NZS standards are also listed in the 50 W safety table. Emergency installation EN/IEC 61347-2-13 (EL), Appendix J, independent control gear; emergency DC input 176–280 VDC. This is a separate application range within the general DC input rating. RCM application RCM is voluntary for L type; it meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1. Type HL application Type HL use in Class I, Division 2 requires consideration of built-in installation. The driver is a component; suitability of the complete luminaire must be established. Isolation tests Withstand: input–output 3.75 kVAC, input–FG 2 kVAC, output–FG 1.5 kVAC. Insulation resistance at each pairing: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN 55015 (CISPR 15), GB/T 17743; BS EN/EN 61000-3-2 and GB 17625.1, Class C at ≥50% load; BS EN/EN 61000-3-3. EMC immunity BS EN/EN 61547; 61000-4-2 ESD Level 3, 8 kV air / Level 2, 4 kV contact; 61000-4-3 radiated Level 3; 61000-4-4 EFT/burst Level 3; 61000-4-6 conducted Level 3; 61000-4-8 magnetic field Level 4. Voltage dips / interruptions BS EN/EN 61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruptions for 250 periods. System compliance and regional marks Re-qualify EMC on the final installation. Products supplied in the Americas may omit CCC/PSE/BIS/KC logos; confirm the supplied label and required market certification. ErP installation condition Use this LED driver behind a switch; it must not remain permanently connected to the mains for the stated lighting-fixture ErP requirement. Mechanical details and wiring Dimensions / case 105 × 63 × 30 mm (L × W × H), case 268A, drawing tolerance ±1 mm. Fixing and mounting Four Ø4.5 mm holes; 99 mm longitudinal and 40 mm transverse fixing spacing; 90 mm inner reference dimension. Use the horizontal orientation shown in the mechanical drawing. Case-temperature measuring point Use the marked tc point, 61.3 mm from the drawing’s right-hand reference and 31.6 mm from its bottom reference. Input cable SJOW 17 AWG × 3C / H05RN-F 3 × 1.0 mm², 300 ±20 mm. AC/L brown, AC/N blue, protective earth/FG green-yellow. Output cable SJOW 17 AWG × 2C / H05RN-F 2 × 1.0 mm², 300 ±20 mm. V+ red and V− black. DALI cable UL 2517 20 AWG × 2C, 350 ±20 mm. DA+ purple, DA− pink. Current adjustment access Use the Io ADJ. potentiometer shown in the mechanical drawing. Drawing references for the adjustment point are 25.8 mm and 9.9 mm. Unit weight 0.42 kg (420 g) per driver, taken directly from the packing specification. Transport packing 24 pieces / 11 kg / 0.81 CUFT; carton data is separate from the unit weight. Applications and selection Typical applications Street, architectural, bay and flood lighting, subject to exact load, installation and market-approval requirements. Selection Match the full SKU, output-current setting, LED voltage and total load to the permitted operating envelope. DALI dimming does not remove the input, thermal or power limits. Measurement basis Unless otherwise stated, specifications are measured at 230 VAC, rated current and 25°C ambient. Model availability Confirm this exact standard or India version and the required certification when ordering. Datasheet catalog stock notes are not live store inventory. Installation manual requirements Installation safety Disconnect the mains supply and prevent accidental reconnection before installation or maintenance. Have faults examined by a qualified technician; do not open the power-supply case yourself. Ventilation and mounting Keep ventilation clear and do not stack objects on the unit. Keep 10–15 cm clearance when the adjacent device is a heat source. Follow this model’s mounting, ambient-temperature and output-derating requirements. System wiring and protection Use approved primary and secondary wiring rated for at least the applicable unit current. Connect the fitted PE/FG lead to protective earth according to the model wiring. Provide suitable system-level insulation and an enclosure around single-insulated wiring; verify EMC again in the completed system. Environmental and load limits Do not immerse the unit or install it near fire or above its specified ambient limit. Keep output current and power within the model’s rated operating envelope. If a fitted external flexible cable is damaged, replacement is limited to the manufacturer, its service agent or a similarly qualified person. Connection seals and support If waterproof connectors are fitted, secure their connections to prevent water entry. Verify the mounting structure and luminaire strength; use safety cables for bay-light applications. Adjustable-unit weather protection This IP67 model has a built-in output-current adjustment function. Install it indoors or in a location sheltered from rain outdoors, as required by the installation manual. IP67 does not permit immersion. DALI-controller installation Verify the compatibility and capacity of the DALI controller and network for the actual installed units. For standalone use with DALI conductors smaller than 18 AWG (0.75 mm²), use SELV controllers/networks; contact MEAN WELL for guidance before using FELV control. Follow this exact model’s DALI wiring. Confirm the exact LED load, operating temperature, control interface and installation requirements against the linked datasheet and manual before commissioning.

You have seen 56 out of 56 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa