MEAN WELL A301-600-F3 is a 600 W rated modified sine wave inverter with 12 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle.
Product Datasheet
Download MEAN WELL A301/302-600 Datasheet (PDF)
The A301/302-600 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation.
Model and AC Output
Rated output power
600 W
Nominal DC input voltage
12 VDC
Rated AC output voltage
230 VAC
Surge output power
1200 W
Output waveform
Modified sine wave
Output frequency
50 Hz ±1%
AC output regulation
±10%
Standard AC receptacles
TYPE-3 European × 1
Complete order code
A301-600-F3
Safety model designation
A301-600
A301 identifies the 12 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment.
The 1200 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply.
DC Input and Supplied Leads
DC input range
10–15 VDC
DC input current
60 A
No-load input current
0.6 A
Typical efficiency
82%
Standard DC connection
900 mm battery-clip lead assembly × 1
Fuse arrangement
25 A × 3
Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating.
The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection.
Controls, Indication and Cooling
Local power control
Power ON/OFF switch
Status indication
Green power-ON and red power-failure indicators
Cooling
Fan ON above 50% load
Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output.
The mechanical drawing identifies normal, over-temperature and overload indications. Fan operation starts above 50% load; keep the intake and exhaust clear.
Protection
Low-battery alarm
10 ±0.5 V
Low-battery shutdown
9.5 ±0.5 V
Over-voltage protection range
15–17 V
Over-temperature protection
60 ±5°C
Output short-circuit protection
Output shut-off
Reverse input polarity
Fuse opens
Overload shutdown
>750 W
An overload above 750 W shuts down the output voltage. Remove the overload and reapply power to recover. This overload trip and the separately listed surge rating describe different operating conditions.
Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above.
Environment and Loading
Specification-table working temperature
0–30°C at 100% load; 40°C at 50% load
Working humidity
20–90% RH, non-condensing
Storage temperature
−30 to +70°C
Storage humidity
10–95% RH, non-condensing
Temperature coefficient
±0.05%/°C over 0–50°C
Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials.
Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model.
Dimensions, Installation and Receptacle Options
Catalogue body reference dimensions
210 × 173 × 65 mm
Catalogue packing reference per unit
2100 g
The 2100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 2.1 kg; 8 pcs / 20 kg / carton.
The specification gives a 210 × 173 × 65 mm body reference. The mounting drawing separately shows a 199 mm overall flange width and 70 mm overall height; allow additional space for connections and cable bends.
The mounting drawing shows four 5 mm open slots, with 190 mm transverse and 91 mm longitudinal centre references. Use the complete drawing to position the mounting hardware and verify clearances; the slot width is not a mounting-screw specification.
Connect the 900 mm battery-clip lead assembly to the correctly marked DC positive and negative inputs. Keep the cooling path and AC receptacles unobstructed.
The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters.
Safety, EMC and Reliability
Safety approval
EAC TP TC 004
Input-to-output insulation resistance
100 MΩ minimum at 500 VDC / 25°C / 70% RH
Manufacturer catalogue warranty
1 year
MTBF, MIL-HDBK-217F at 25°C
100 k hours minimum
The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation.
EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1.
Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.