A301/302 Series: Modified Sine Wave DC-AC Inverter

26 products

MEAN WELL A301/A302 Series True Sine Wave Inverters

  • Product Features
  • Technical Specifications
  • Series Overview
  • Operation Guide

Product Features

The A301/A302 series are high-reliability, true sine wave DC-AC inverters designed to provide stable power for a wide array of industrial and consumer applications.

  • True Sine Wave Output: Provides a stable and clean power supply (THD < 3%), ensuring compatibility with sensitive equipment such as medical devices, precision instruments, and high-end audio systems.
  • High-Reliability Design: Engineered with a focus on durability and stable performance under varying load conditions.
  • Protective Suite: Integrated safety features including Short circuit, Overload, Over voltage, and Over temperature protection.
  • Global Utility: Suitable for a variety of input voltage configurations and output frequency requirements.
  • Quiet Operation: Built-in cooling fans (thermo-controlled) ensure efficient heat management with minimized noise.

Technical Specifications

Parameter Specification Detail
Output Waveform True Sine Wave (THD < 3%)
Output Frequency 50Hz / 60Hz (Model dependent)
Protection Short circuit / Overload / Over temp / Over voltage
Efficiency High-efficiency power conversion
Cooling Thermo-controlled cooling fan

Series Overview

Model Rated Power Input Voltage Output Voltage
A301 300W 12V DC / 24V DC 110V AC / 230V AC
A302 300W 12V DC / 24V DC 110V AC / 230V AC
Applications: Ideal for portable power systems, RVs/campers, remote off-grid monitoring, and essential backup power for emergency lighting or communication devices.

Operation Guide

Ensure correct system installation to maintain the longevity of both the inverter and the connected battery bank.

Consideration Recommendation
Input Source Ensure the DC input (12V or 24V) exactly matches your battery system.
Load Sizing Calculate the peak power (surge) of your loads, not just the continuous rating, to prevent overload shutdowns.
Cable Sizing Use high-gauge cables to minimize voltage drop between the battery and the inverter, especially at high loads.
Safety Note: Ensure proper ventilation around the inverter's cooling vents. Never block the airflow path, as this will trigger the over-temperature protection circuit.
  • A302-2K5-F3

    MEAN WELL A301/302-2K5 series: Modified Sine Wave DC-AC Power Inverter - A302-2K5-F3

    MEAN WELL A302-2K5-F3 is a 2500 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-2500 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-2K5 Datasheet (PDF) The A301/302-2K5 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-2K5-F3 Series A301/302-2K5 Safety model number A302-2K5 Rated output power 2500 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Surge power 5000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 5000 W surge rating is separate from the 2500 W rated output. Select transient loads against the manufacturer’s operating limits. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 130 A No-load current draw 0.6 A Typical efficiency 85% DC connection No DC connector/cable listed; positive and negative M8 stud terminals shown Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >2700 W Overvoltage protection 30–32 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 15 A × 12 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–25°C at 100% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates overload protection. Battery-voltage and current meters are also provided. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 430 × 210 × 159 mm Catalogue mass per unit 8.7 kg / 8700 g The DC input uses the positive POS+ and negative NEG− stud connections shown in the mechanical drawing. Two M8 studs are shown at 60 mm spacing, with a 23 mm projection. The specification lists no supplied DC connector/cable; select suitable battery leads and terminations for the application. Do not reverse input polarity. The catalogue body dimensions are 430 × 210 × 159 mm. The mechanical drawing also labels a 450 mm mounting dimension, a 160 mm bracket dimension, 119 mm slot spacing and a 19 mm front receptacle projection. Use the complete drawing to determine the installed space and mounting arrangement; keep the fan airflow clear. The PACKING entry gives 8.7 kg as the catalogue reference per unit (8.7 kg; 2 pcs / 19 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-2500 Remote function Power ON/OFF RC-2500 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 37 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $1,158.21

  • A302-2K5-B4

    MEAN WELL A301/302-2K5 series: Modified Sine Wave DC-AC Power Inverter - A302-2K5-B4

    MEAN WELL A302-2K5-B4 is a 2500 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 2 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-2500 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-2K5 Datasheet (PDF) The A301/302-2K5 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-2K5-B4 Series A301/302-2K5 Safety model number A302-2K5 Rated output power 2500 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 2; USA Surge power 5000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 5000 W surge rating is separate from the 2500 W rated output. Select transient loads against the manufacturer’s operating limits. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 130 A No-load current draw 0.6 A Typical efficiency 85% DC connection No DC connector/cable listed; positive and negative M8 stud terminals shown Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >2700 W Overvoltage protection 30–32 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 15 A × 12 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–25°C at 100% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates overload protection. Battery-voltage and current meters are also provided. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 430 × 210 × 159 mm Catalogue mass per unit 8.7 kg / 8700 g The DC input uses the positive POS+ and negative NEG− stud connections shown in the mechanical drawing. Two M8 studs are shown at 60 mm spacing, with a 23 mm projection. The specification lists no supplied DC connector/cable; select suitable battery leads and terminations for the application. Do not reverse input polarity. The catalogue body dimensions are 430 × 210 × 159 mm. The mechanical drawing also labels a 450 mm mounting dimension, a 160 mm bracket dimension, 119 mm slot spacing and a 19 mm front receptacle projection. Use the complete drawing to determine the installed space and mounting arrangement; keep the fan airflow clear. The PACKING entry gives 8.7 kg as the catalogue reference per unit (8.7 kg; 2 pcs / 19 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-2500 Remote function Power ON/OFF RC-2500 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 37 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $1,158.21

  • A301-2K5-F3

    MEAN WELL A301/302-2K5 series: Modified Sine Wave DC-AC Power Inverter - A301-2K5-F3

    MEAN WELL A301-2K5-F3 is a 2500 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-2500 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-2K5 Datasheet (PDF) The A301/302-2K5 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-2K5-F3 Series A301/302-2K5 Safety model number A301-2K5 Rated output power 2500 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Surge power 5000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 5000 W surge rating is separate from the 2500 W rated output. Select transient loads against the manufacturer’s operating limits. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 250 A No-load current draw 0.9 A Typical efficiency 82% DC connection No DC connector/cable listed; positive and negative M8 stud terminals shown Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >2700 W Overvoltage protection 15–17 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 12 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–25°C at 100% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates overload protection. Battery-voltage and current meters are also provided. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 430 × 210 × 159 mm Catalogue mass per unit 8.7 kg / 8700 g The DC input uses the positive POS+ and negative NEG− stud connections shown in the mechanical drawing. Two M8 studs are shown at 60 mm spacing, with a 23 mm projection. The specification lists no supplied DC connector/cable; select suitable battery leads and terminations for the application. Do not reverse input polarity. The catalogue body dimensions are 430 × 210 × 159 mm. The mechanical drawing also labels a 450 mm mounting dimension, a 160 mm bracket dimension, 119 mm slot spacing and a 19 mm front receptacle projection. Use the complete drawing to determine the installed space and mounting arrangement; keep the fan airflow clear. The PACKING entry gives 8.7 kg as the catalogue reference per unit (8.7 kg; 2 pcs / 19 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-2500 Remote function Power ON/OFF RC-2500 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 37 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $1,158.21

  • A301-2K5-B4

    MEAN WELL A301/302-2K5 series: Modified Sine Wave DC-AC Power Inverter - A301-2K5-B4

    MEAN WELL A301-2K5-B4 is a 2500 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 2 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-2500 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-2K5 Datasheet (PDF) The A301/302-2K5 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-2K5-B4 Series A301/302-2K5 Safety model number A301-2K5 Rated output power 2500 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 2; USA Surge power 5000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 5000 W surge rating is separate from the 2500 W rated output. Select transient loads against the manufacturer’s operating limits. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 250 A No-load current draw 0.9 A Typical efficiency 82% DC connection No DC connector/cable listed; positive and negative M8 stud terminals shown Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >2700 W Overvoltage protection 15–17 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 12 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–25°C at 100% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates overload protection. Battery-voltage and current meters are also provided. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 430 × 210 × 159 mm Catalogue mass per unit 8.7 kg / 8700 g The DC input uses the positive POS+ and negative NEG− stud connections shown in the mechanical drawing. Two M8 studs are shown at 60 mm spacing, with a 23 mm projection. The specification lists no supplied DC connector/cable; select suitable battery leads and terminations for the application. Do not reverse input polarity. The catalogue body dimensions are 430 × 210 × 159 mm. The mechanical drawing also labels a 450 mm mounting dimension, a 160 mm bracket dimension, 119 mm slot spacing and a 19 mm front receptacle projection. Use the complete drawing to determine the installed space and mounting arrangement; keep the fan airflow clear. The PACKING entry gives 8.7 kg as the catalogue reference per unit (8.7 kg; 2 pcs / 19 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-2500 Remote function Power ON/OFF RC-2500 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 37 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $1,158.21

  • A302-1K7-F3

    MEAN WELL A301/302-1K7 series: Modified Sine Wave DC-AC Power Inverter - A302-1K7-F3

    MEAN WELL A302-1K7-F3 is a 1500 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K7 Datasheet (PDF) The A301/302-1K7 section is on PDF pages 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-1K7-F3 Series A301/302-1K7 Safety model number A302-1K7 Rated output power 1500 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Peak output power 1700 W, 30 minutes Surge power 3000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1K7 model code identifies a unit rated at 1500 W; 1700 W is the separately specified 30-minute peak rating. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 85 A No-load current draw 0.36 A Typical efficiency 85% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >1700 W Overvoltage protection 29–31 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 20 A × 10 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON and red indicates power-failure status. The front drawing identifies NORMAL, OVER TEMP. and OVER LOAD indicators. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 455 × 210 × 85 mm Catalogue mass per unit 5.5 kg / 5500 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. Use the cable and connection arrangement specified for this model. The mounting drawing marks a 240 mm transverse reference and 362 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The specification lists 85 mm height, while the mechanical front view marks 90 mm; use the mechanical drawing for installed clearance. The PACKING entry gives 5.5 kg as the catalogue reference per unit (5.5 kg; 3 pcs / 19.6 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $961.07

  • A302-1K7-B2

    MEAN WELL A301/302-1K7 series: Modified Sine Wave DC-AC Power Inverter - A302-1K7-B2

    MEAN WELL A302-1K7-B2 is a 1500 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 3 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K7 Datasheet (PDF) The A301/302-1K7 section is on PDF pages 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-1K7-B2 Series A301/302-1K7 Safety model number A302-1K7 Rated output power 1500 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 3; USA Peak output power 1700 W, 30 minutes Surge power 3000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1K7 model code identifies a unit rated at 1500 W; 1700 W is the separately specified 30-minute peak rating. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 85 A No-load current draw 0.36 A Typical efficiency 85% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >1700 W Overvoltage protection 29–31 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 20 A × 10 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON and red indicates power-failure status. The front drawing identifies NORMAL, OVER TEMP. and OVER LOAD indicators. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 455 × 210 × 85 mm Catalogue mass per unit 5.5 kg / 5500 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. Use the cable and connection arrangement specified for this model. The mounting drawing marks a 240 mm transverse reference and 362 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The specification lists 85 mm height, while the mechanical front view marks 90 mm; use the mechanical drawing for installed clearance. The PACKING entry gives 5.5 kg as the catalogue reference per unit (5.5 kg; 3 pcs / 19.6 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $961.07

  • A301-1K7-F3

    MEAN WELL A301/302-1K7 series: Modified Sine Wave DC-AC Power Inverter - A301-1K7-F3

    MEAN WELL A301-1K7-F3 is a 1500 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K7 Datasheet (PDF) The A301/302-1K7 section is on PDF pages 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-1K7-F3 Series A301/302-1K7 Safety model number A301-1K7 Rated output power 1500 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Peak output power 1700 W, 30 minutes Surge power 3000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1K7 model code identifies a unit rated at 1500 W; 1700 W is the separately specified 30-minute peak rating. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 170 A No-load current draw 0.6 A Typical efficiency 82% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >1700 W Overvoltage protection 15–16 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 10 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON and red indicates power-failure status. The front drawing identifies NORMAL, OVER TEMP. and OVER LOAD indicators. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 455 × 210 × 85 mm Catalogue mass per unit 5.5 kg / 5500 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. Use the cable and connection arrangement specified for this model. The mounting drawing marks a 240 mm transverse reference and 362 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The specification lists 85 mm height, while the mechanical front view marks 90 mm; use the mechanical drawing for installed clearance. The PACKING entry gives 5.5 kg as the catalogue reference per unit (5.5 kg; 3 pcs / 19.6 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $961.07

  • A301-1K7-B2

    MEAN WELL A301/302-1K7 series: Modified Sine Wave DC-AC Power Inverter - A301-1K7-B2

    MEAN WELL A301-1K7-B2 is a 1500 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 3 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K7 Datasheet (PDF) The A301/302-1K7 section is on PDF pages 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-1K7-B2 Series A301/302-1K7 Safety model number A301-1K7 Rated output power 1500 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 3; USA Peak output power 1700 W, 30 minutes Surge power 3000 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1K7 model code identifies a unit rated at 1500 W; 1700 W is the separately specified 30-minute peak rating. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 170 A No-load current draw 0.6 A Typical efficiency 82% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >1700 W Overvoltage protection 15–16 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 10 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON and red indicates power-failure status. The front drawing identifies NORMAL, OVER TEMP. and OVER LOAD indicators. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 455 × 210 × 85 mm Catalogue mass per unit 5.5 kg / 5500 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. Use the cable and connection arrangement specified for this model. The mounting drawing marks a 240 mm transverse reference and 362 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The specification lists 85 mm height, while the mechanical front view marks 90 mm; use the mechanical drawing for installed clearance. The PACKING entry gives 5.5 kg as the catalogue reference per unit (5.5 kg; 3 pcs / 19.6 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $961.07

  • A302-1K0-F3

    MEAN WELL A301/302-1K0 series: Modified Sine Wave DC-AC Power Inverter - A302-1K0-F3

    MEAN WELL A302-1K0-F3 is a 1000 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K0 Datasheet (PDF) The A301/302-1K0 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-1K0-F3 Series A301/302-1K0 Safety model number A302-1K0 Rated output power 1000 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Peak output power 1200 W, less than 30 minutes Surge power 2400 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1200 W peak rating is limited to less than 30 minutes. Use the 1000 W rated output within the temperature limits. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 55 A No-load current draw 0.2 A Typical efficiency 85% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >1200 W Overvoltage protection 29–31 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 20 A × 5 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates power-failure status. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 310 × 210 × 85 mm Catalogue mass per unit 3.3 kg / 3300 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. The cable cross-section is marked 14 mm² in the drawing. The mounting drawing marks a 240 mm transverse reference and 219 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The PACKING entry gives 3.3 kg as the catalogue reference per unit (3.3 kg; 4 pcs / 17.5 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 98 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $630.86

  • A302-1K0-B2

    MEAN WELL A301/302-1K0 series: Modified Sine Wave DC-AC Power Inverter - A302-1K0-B2

    MEAN WELL A302-1K0-B2 is a 1000 W rated modified sine wave DC-AC power inverter for a 24 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 3 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K0 Datasheet (PDF) The A301/302-1K0 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A302-1K0-B2 Series A301/302-1K0 Safety model number A302-1K0 Rated output power 1000 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 3; USA Peak output power 1200 W, less than 30 minutes Surge power 2400 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1200 W peak rating is limited to less than 30 minutes. Use the 1000 W rated output within the temperature limits. DC Input and Efficiency DC input operating range 21–30 VDC DC input current 55 A No-load current draw 0.2 A Typical efficiency 85% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 21 ±0.8 V Battery low shutdown 20 ±0.8 V Overload threshold >1200 W Overvoltage protection 29–31 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 20 A × 5 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates power-failure status. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 310 × 210 × 85 mm Catalogue mass per unit 3.3 kg / 3300 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. The cable cross-section is marked 14 mm² in the drawing. The mounting drawing marks a 240 mm transverse reference and 219 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The PACKING entry gives 3.3 kg as the catalogue reference per unit (3.3 kg; 4 pcs / 17.5 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 98 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $630.86

  • A301-1K0-F3

    MEAN WELL A301/302-1K0 series: Modified Sine Wave DC-AC Power Inverter - A301-1K0-F3

    MEAN WELL A301-1K0-F3 is a 1000 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 230 VAC at 50 Hz through 2 European TYPE-3 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K0 Datasheet (PDF) The A301/302-1K0 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-1K0-F3 Series A301/302-1K0 Safety model number A301-1K0 Rated output power 1000 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Output frequency 50 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-3 × 2; European Peak output power 1200 W, less than 30 minutes Surge power 2400 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1200 W peak rating is limited to less than 30 minutes. Use the 1000 W rated output within the temperature limits. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 110 A No-load current draw 0.4 A Typical efficiency 82% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >1200 W Overvoltage protection 15–16 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 5 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates power-failure status. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 310 × 210 × 85 mm Catalogue mass per unit 3.3 kg / 3300 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. The cable cross-section is marked 14 mm² in the drawing. The mounting drawing marks a 240 mm transverse reference and 219 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The PACKING entry gives 3.3 kg as the catalogue reference per unit (3.3 kg; 4 pcs / 17.5 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 98 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $630.86

  • A301-1K0-B2

    MEAN WELL A301/302-1K0 series: Modified Sine Wave DC-AC Power Inverter - A301-1K0-B2

    MEAN WELL A301-1K0-B2 is a 1000 W rated modified sine wave DC-AC power inverter for a 12 VDC nominal battery supply. It provides 110 VAC at 60 Hz through 3 USA TYPE-2 receptacles, with a front power switch, status indicators and temperature-controlled fan. The RC-1700 remote ON/OFF controller is an optional accessory ordered separately. Product Datasheet Download MEAN WELL A301/302-1K0 Datasheet (PDF) The A301/302-1K0 section is on PDF pages 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model, Output and Receptacles Complete order number A301-1K0-B2 Series A301/302-1K0 Safety model number A301-1K0 Rated output power 1000 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Output frequency 60 Hz ±1% Waveform Modified sine wave AC voltage regulation ±10% Standard AC receptacles TYPE-2 × 3; USA Peak output power 1200 W, less than 30 minutes Surge power 2400 W Match the load to the modified sine wave output and the complete model’s fixed voltage, frequency and receptacle arrangement. The surge rating is a transient capability, separate from the rated output. The 1200 W peak rating is limited to less than 30 minutes. Use the 1000 W rated output within the temperature limits. DC Input and Efficiency DC input operating range 10–15 VDC DC input current 110 A No-load current draw 0.4 A Typical efficiency 82% DC connection 1000 mm R-type terminal cable Select the battery supply, conductors and load together for the rated DC current and permitted input-voltage range. A301 identifies the 12 VDC input version; A302 identifies the 24 VDC input version. Protection Battery low alarm 10 ±0.5 V Battery low shutdown 9.5 ±0.5 V Overload threshold >1200 W Overvoltage protection 15–16 V Overtemperature threshold 60 ±5°C / 140 ±9°F Fuse rating and quantity 30 A × 5 Overload protection shuts down the output voltage; re-power the inverter to recover after removing the overload. Output short-circuit protection shuts off the output. Reverse battery polarity opens the fuse. The overtemperature threshold is a protection value, distinct from the ambient working-temperature limits. Follow the actual operating-temperature and loading limits when sizing the installation. Operation, Cooling and Environment Ambient working conditions 0–30°C at 100% load; 40°C at 70% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C / −22 to +158°F Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C, over 0–50°C Cooling control Fan ON above 40°C at the NTC Green indicates power ON, yellow indicates overtemperature protection, and red indicates power-failure status. Use the local ON/OFF power switch or the specified optional remote controller. The temperature-controlled fan and its airflow path must remain unobstructed; the NTC switching value does not extend the permitted ambient-temperature range. Dimensions, Connections and Mass Catalogue dimensions, L × W × H 310 × 210 × 85 mm Catalogue mass per unit 3.3 kg / 3300 g The DC input uses the shown 1000 mm cable with R-type ring terminals. The ring holes are 10.6 mm in diameter. Connect to the marked positive and negative battery terminals and do not reverse polarity. The cable cross-section is marked 14 mm² in the drawing. The mounting drawing marks a 240 mm transverse reference and 219 mm longitudinal mounting-hole spacing. Keep the illustrated fan airflow clear and use the complete drawing to allow space for the leads, receptacles and mounting flanges. The PACKING entry gives 3.3 kg as the catalogue reference per unit (3.3 kg; 4 pcs / 17.5 kg / carton). This reference is not a measured shipment weight. Optional Remote and Receptacle Selection Optional remote controller RC-1700 Remote function Power ON/OFF RC-1700 is the optional remote ON/OFF controller specified for this series. Connect it to the front REMOTE CONTROL port using its appropriate connection assembly; order the controller separately. The receptacle-option table shows TYPE-1 Japan, TYPE-2 USA, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK. This complete order number has the standard receptacles stated above; confirm any different factory receptacle configuration before ordering. Applications include suitable home appliances, power tools, office equipment, portable equipment and vehicle systems. Check load compatibility with the modified sine wave output. The manufacturer catalogue lists a one-year warranty; applicable supply terms govern coverage. Safety, EMC and Reliability Listed safety approval EAC TP TC 004 Input/output isolation resistance 100 MΩ at 500 VDC, 25°C, 70% RH EMI radiation compliance BS EN/EN55014-1; EAC TP TC 020 EMS immunity compliance BS EN/EN55014-2; IEC61000-4-2 and -3; EAC TP TC 020 LVD compliance BS EN/EN62368-1 MTBF, MIL-HDBK-217F 98 thousand hours minimum at 25°C The series feature panel lists E13, EAC, CE and UKCA marks. Apply the stated standards to the exact model and verify the complete equipment’s installation requirements.

    $630.86

  • A302-600-F3

    MEAN WELL A301/302-600 series: Modified Sine Wave DC-AC Power Inverter - A302-600-F3

    MEAN WELL A302-600-F3 is a 600 W rated modified sine wave inverter with 24 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Product Datasheet Download MEAN WELL A301/302-600 Datasheet (PDF) The A301/302-600 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 600 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Surge output power 1200 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A302-600-F3 Safety model designation A302-600 A302 identifies the 24 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 1200 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 30 A No-load input current 0.38 A Typical efficiency 85% Standard DC connection 900 mm battery-clip lead assembly × 1 Fuse arrangement 20 A × 3 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 50% load Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The mechanical drawing identifies normal, over-temperature and overload indications. Fan operation starts above 50% load; keep the intake and exhaust clear. Protection Low-battery alarm 21 ±1 V Low-battery shutdown 20 ±1 V Over-voltage protection range 30–32 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload shutdown >750 W An overload above 750 W shuts down the output voltage. Remove the overload and reapply power to recover. This overload trip and the separately listed surge rating describe different operating conditions. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 210 × 173 × 65 mm Catalogue packing reference per unit 2100 g The 2100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 2.1 kg; 8 pcs / 20 kg / carton. The specification gives a 210 × 173 × 65 mm body reference. The mounting drawing separately shows a 199 mm overall flange width and 70 mm overall height; allow additional space for connections and cable bends. The mounting drawing shows four 5 mm open slots, with 190 mm transverse and 91 mm longitudinal centre references. Use the complete drawing to position the mounting hardware and verify clearances; the slot width is not a mounting-screw specification. Connect the 900 mm battery-clip lead assembly to the correctly marked DC positive and negative inputs. Keep the cooling path and AC receptacles unobstructed. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 100 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $312.96

  • A302-600-B2

    MEAN WELL A301/302-600 series: Modified Sine Wave DC-AC Power Inverter - A302-600-B2

    MEAN WELL A302-600-B2 is a 600 W rated modified sine wave inverter with 24 VDC input and 110 VAC, 60 Hz output through two TYPE-2 US receptacles. Product Datasheet Download MEAN WELL A301/302-600 Datasheet (PDF) The A301/302-600 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 600 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Surge output power 1200 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 2 Complete order code A302-600-B2 Safety model designation A302-600 A302 identifies the 24 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 1200 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 30 A No-load input current 0.35 A Typical efficiency 85% Standard DC connection 900 mm battery-clip lead assembly × 1 Fuse arrangement 20 A × 3 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 50% load Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The mechanical drawing identifies normal, over-temperature and overload indications. Fan operation starts above 50% load; keep the intake and exhaust clear. Protection Low-battery alarm 19 ±0.8 V Low-battery shutdown 18 ±0.8 V Over-voltage protection range 30–32 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload shutdown >750 W An overload above 750 W shuts down the output voltage. Remove the overload and reapply power to recover. This overload trip and the separately listed surge rating describe different operating conditions. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 210 × 173 × 65 mm Catalogue packing reference per unit 2100 g The 2100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 2.1 kg; 8 pcs / 20 kg / carton. The specification gives a 210 × 173 × 65 mm body reference. The mounting drawing separately shows a 199 mm overall flange width and 70 mm overall height; allow additional space for connections and cable bends. The mounting drawing shows four 5 mm open slots, with 190 mm transverse and 91 mm longitudinal centre references. Use the complete drawing to position the mounting hardware and verify clearances; the slot width is not a mounting-screw specification. Connect the 900 mm battery-clip lead assembly to the correctly marked DC positive and negative inputs. Keep the cooling path and AC receptacles unobstructed. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 100 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $312.96

  • A301-600-F3

    MEAN WELL A301/302-600 series: Modified Sine Wave DC-AC Power Inverter - A301-600-F3

    MEAN WELL A301-600-F3 is a 600 W rated modified sine wave inverter with 12 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Product Datasheet Download MEAN WELL A301/302-600 Datasheet (PDF) The A301/302-600 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 600 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Surge output power 1200 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A301-600-F3 Safety model designation A301-600 A301 identifies the 12 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 1200 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 60 A No-load input current 0.6 A Typical efficiency 82% Standard DC connection 900 mm battery-clip lead assembly × 1 Fuse arrangement 25 A × 3 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 50% load Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The mechanical drawing identifies normal, over-temperature and overload indications. Fan operation starts above 50% load; keep the intake and exhaust clear. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload shutdown >750 W An overload above 750 W shuts down the output voltage. Remove the overload and reapply power to recover. This overload trip and the separately listed surge rating describe different operating conditions. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 210 × 173 × 65 mm Catalogue packing reference per unit 2100 g The 2100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 2.1 kg; 8 pcs / 20 kg / carton. The specification gives a 210 × 173 × 65 mm body reference. The mounting drawing separately shows a 199 mm overall flange width and 70 mm overall height; allow additional space for connections and cable bends. The mounting drawing shows four 5 mm open slots, with 190 mm transverse and 91 mm longitudinal centre references. Use the complete drawing to position the mounting hardware and verify clearances; the slot width is not a mounting-screw specification. Connect the 900 mm battery-clip lead assembly to the correctly marked DC positive and negative inputs. Keep the cooling path and AC receptacles unobstructed. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 100 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $312.96

  • A301-600-B2

    MEAN WELL A301/302-600 series: Modified Sine Wave DC-AC Power Inverter - A301-600-B2

    MEAN WELL A301-600-B2 is a 600 W rated modified sine wave inverter with 12 VDC input and 110 VAC, 60 Hz output through two TYPE-2 US receptacles. Product Datasheet Download MEAN WELL A301/302-600 Datasheet (PDF) The A301/302-600 section is on PDF pages 9, 10. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 600 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Surge output power 1200 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 2 Complete order code A301-600-B2 Safety model designation A301-600 A301 identifies the 12 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 1200 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 60 A No-load input current 0.5 A Typical efficiency 82% Standard DC connection 900 mm battery-clip lead assembly × 1 Fuse arrangement 25 A × 3 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 50% load Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The mechanical drawing identifies normal, over-temperature and overload indications. Fan operation starts above 50% load; keep the intake and exhaust clear. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload shutdown >750 W An overload above 750 W shuts down the output voltage. Remove the overload and reapply power to recover. This overload trip and the separately listed surge rating describe different operating conditions. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 210 × 173 × 65 mm Catalogue packing reference per unit 2100 g The 2100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 2.1 kg; 8 pcs / 20 kg / carton. The specification gives a 210 × 173 × 65 mm body reference. The mounting drawing separately shows a 199 mm overall flange width and 70 mm overall height; allow additional space for connections and cable bends. The mounting drawing shows four 5 mm open slots, with 190 mm transverse and 91 mm longitudinal centre references. Use the complete drawing to position the mounting hardware and verify clearances; the slot width is not a mounting-screw specification. Connect the 900 mm battery-clip lead assembly to the correctly marked DC positive and negative inputs. Keep the cooling path and AC receptacles unobstructed. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 100 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $312.96

  • A302-300-F3

    MEAN WELL A301/302-300 series: Modified Sine Wave DC-AC Power Inverter - A302-300-F3

    MEAN WELL A302-300-F3 is a 300 W rated modified sine wave inverter with 24 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Product Datasheet Download MEAN WELL A301/302-300 Datasheet (PDF) The A301/302-300 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 300 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Surge output power 600 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A302-300-F3 Safety model designation A302-300 A302 identifies the 24 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 600 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 15 A No-load input current 0.2 A Typical efficiency 85% Standard DC connection Cigarette-plug lead × 1 and battery-clip lead assembly × 1 Fuse arrangement Battery cord: 20 A × 1; cigarette plug: 10 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. The cigarette-plug fuse and battery-cord fuse have different ratings. Available load is limited by the chosen DC lead and its upstream supply; the cigarette-plug connection does not establish unrestricted 300 W operation. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 100 W load or above 40°C at the NTC Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The fan starts when the output load is greater than 100 W or the NTC temperature is greater than 40°C. Both activation conditions belong to this 300 W family. Protection Low-battery alarm 20 ±0.8 V Low-battery shutdown 19.5 ±0.8 V Over-voltage protection range 30–32 V Over-temperature protection 45 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 88 × 74 mm Catalogue packing reference per unit 1100 g The 1100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 1.1 kg; 16 pcs / 19 kg / carton. The drawing separately marks an 18.5 mm rear projection beyond the 165 mm body length. Leave space for the DC positive/negative terminals, fan airflow, AC plug and cable bends. The US and European versions have different front-panel receptacle and switch layouts. Follow the polarity markings on the actual DC input terminals. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $170.04

  • A302-300-B2

    MEAN WELL A301/302-300 series: Modified Sine Wave DC-AC Power Inverter - A302-300-B2

    MEAN WELL A302-300-B2 is a 300 W rated modified sine wave inverter with 24 VDC input and 110 VAC, 60 Hz output through two TYPE-2 US receptacles. Product Datasheet Download MEAN WELL A301/302-300 Datasheet (PDF) The A301/302-300 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 300 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Surge output power 600 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 2 Complete order code A302-300-B2 Safety model designation A302-300 A302 identifies the 24 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 600 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 15 A No-load input current 0.2 A Typical efficiency 85% Standard DC connection Cigarette-plug lead × 1 and battery-clip lead assembly × 1 Fuse arrangement Battery cord: 20 A × 1; cigarette plug: 10 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. The cigarette-plug fuse and battery-cord fuse have different ratings. Available load is limited by the chosen DC lead and its upstream supply; the cigarette-plug connection does not establish unrestricted 300 W operation. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 100 W load or above 40°C at the NTC Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The fan starts when the output load is greater than 100 W or the NTC temperature is greater than 40°C. Both activation conditions belong to this 300 W family. Protection Low-battery alarm 20 ±0.8 V Low-battery shutdown 19.5 ±0.8 V Over-voltage protection range 30–32 V Over-temperature protection 45 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 88 × 74 mm Catalogue packing reference per unit 1100 g The 1100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 1.1 kg; 16 pcs / 19 kg / carton. The drawing separately marks an 18.5 mm rear projection beyond the 165 mm body length. Leave space for the DC positive/negative terminals, fan airflow, AC plug and cable bends. The US and European versions have different front-panel receptacle and switch layouts. Follow the polarity markings on the actual DC input terminals. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $170.04

  • A301-300-F3

    MEAN WELL A301/302-300 series: Modified Sine Wave DC-AC Power Inverter - A301-300-F3

    MEAN WELL A301-300-F3 is a 300 W rated modified sine wave inverter with 12 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Product Datasheet Download MEAN WELL A301/302-300 Datasheet (PDF) The A301/302-300 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 300 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Surge output power 600 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A301-300-F3 Safety model designation A301-300 A301 identifies the 12 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 600 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 35 A No-load input current 0.36 A Typical efficiency 82% Standard DC connection Cigarette-plug lead × 1 and battery-clip lead assembly × 1 Fuse arrangement Battery cord: 35 A × 1; cigarette plug: 15 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. The cigarette-plug fuse and battery-cord fuse have different ratings. Available load is limited by the chosen DC lead and its upstream supply; the cigarette-plug connection does not establish unrestricted 300 W operation. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 100 W load or above 40°C at the NTC Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The fan starts when the output load is greater than 100 W or the NTC temperature is greater than 40°C. Both activation conditions belong to this 300 W family. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 45 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 88 × 74 mm Catalogue packing reference per unit 1100 g The 1100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 1.1 kg; 16 pcs / 19 kg / carton. The drawing separately marks an 18.5 mm rear projection beyond the 165 mm body length. Leave space for the DC positive/negative terminals, fan airflow, AC plug and cable bends. The US and European versions have different front-panel receptacle and switch layouts. Follow the polarity markings on the actual DC input terminals. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $170.04

  • A301-300-B2

    MEAN WELL A301/302-300 series: Modified Sine Wave DC-AC Power Inverter - A301-300-B2

    MEAN WELL A301-300-B2 is a 300 W rated modified sine wave inverter with 12 VDC input and 110 VAC, 60 Hz output through two TYPE-2 US receptacles. Product Datasheet Download MEAN WELL A301/302-300 Datasheet (PDF) The A301/302-300 section is on PDF pages 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 300 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Surge output power 600 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 2 Complete order code A301-300-B2 Safety model designation A301-300 A301 identifies the 12 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 600 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 35 A No-load input current 0.36 A Typical efficiency 82% Standard DC connection Cigarette-plug lead × 1 and battery-clip lead assembly × 1 Fuse arrangement Battery cord: 35 A × 1; cigarette plug: 15 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. The cigarette-plug fuse and battery-cord fuse have different ratings. Available load is limited by the chosen DC lead and its upstream supply; the cigarette-plug connection does not establish unrestricted 300 W operation. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON and red power-failure indicators Cooling Fan ON above 100 W load or above 40°C at the NTC Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. The fan starts when the output load is greater than 100 W or the NTC temperature is greater than 40°C. Both activation conditions belong to this 300 W family. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 45 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Environment and Loading Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. Reduce loading to the stated 50% at 40°C. The catalogue does not specify an extended high-temperature operating envelope for this model. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 88 × 74 mm Catalogue packing reference per unit 1100 g The 1100 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 1.1 kg; 16 pcs / 19 kg / carton. The drawing separately marks an 18.5 mm rear projection beyond the 165 mm body length. Leave space for the DC positive/negative terminals, fan airflow, AC plug and cable bends. The US and European versions have different front-panel receptacle and switch layouts. Follow the polarity markings on the actual DC input terminals. The catalogue illustrates TYPE-1 Japan, TYPE-2 US, TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. The standard receptacle type and quantity for this exact order code are listed above. Confirm the factory ordering configuration for another option; the illustrated sockets are not interchangeable plug-in adapters. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $170.04

  • A302-150-F3

    MEAN WELL A301/302-150 series: Modified Sine Wave DC-AC Power Inverter - A302-150-F3

    MEAN WELL A302-150-F3 is a 150 W rated modified sine wave inverter with 24 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Output is subject to the separate duration and derating limits below. Product Datasheet Download MEAN WELL A301/302-150 Datasheet (PDF) The A301/302-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 150 W Nominal DC input voltage 24 VDC Rated AC output voltage 230 VAC Surge output power 300 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A302-150-F3 Safety model designation A302-150 A302 identifies the 24 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 300 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. The 150 W rating is subject to the separate load-duration and temperature limits below; it is not an unlimited-duration 150 W operating guarantee. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 10 A No-load input current 0.2 A Typical efficiency 82% Standard DC connection 700 mm cigarette-plug lead × 1 Fuse arrangement 10 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Dual-color indication of power ON / failure Cooling Free-air convection Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. Protection Low-battery alarm 20.5 ±1 V Low-battery shutdown 19.5 ±1 V Over-voltage protection range 30–32 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Load Duration and Environment Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C 100% load duration 20 minutes 80% load duration 40 minutes 70% load duration 120 minutes Continuous-duty load reference 60% of rated power Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. The separate derating graph limits output to 70% of rating from 0 to 20°C and reduces it to 30% at 40°C. Its load limit must also be observed alongside the duration chart. Use the lower applicable thermal and duration limit. The continuous-duty reference is 90 W before any stricter temperature derating; the 150 W table rating and the specification-table temperature entry do not override these operating charts. Confirm the intended operating point if it falls outside their combined limits. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 94 × 69 mm Catalogue packing reference per unit 800 g (0.8 kg), from the manufacturer's PACKING entry; not a measured net or shipping-parcel weight. Use the supplied DC lead and the receptacle appropriate to this version. The body dimensions do not include a connected AC plug, DC cable bend or required ventilation clearance. The applicable catalogue page illustrates TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. This F3 order code specifies TYPE-3; request and confirm any different factory receptacle arrangement before ordering. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $119.76

  • A301-150-F3

    MEAN WELL A301/302-150 series: Modified Sine Wave DC-AC Power Inverter - A301-150-F3

    MEAN WELL A301-150-F3 is a 150 W rated modified sine wave inverter with 12 VDC input and 230 VAC, 50 Hz output through one TYPE-3 European receptacle. Output is subject to the separate duration and derating limits below. Product Datasheet Download MEAN WELL A301/302-150 Datasheet (PDF) The A301/302-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 150 W Nominal DC input voltage 12 VDC Rated AC output voltage 230 VAC Surge output power 300 W Output waveform Modified sine wave Output frequency 50 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-3 European × 1 Complete order code A301-150-F3 Safety model designation A301-150 A301 identifies the 12 VDC input version. The F3 suffix selects the 230 VAC, 50 Hz output and the TYPE-3 European receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 300 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. The 150 W rating is subject to the separate load-duration and temperature limits below; it is not an unlimited-duration 150 W operating guarantee. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 15 A No-load input current 0.25 A Typical efficiency 78% Standard DC connection 700 mm cigarette-plug lead × 1 Fuse arrangement 15 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Dual-color indication of power ON / failure Cooling Free-air convection Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. Remove the cause of a short circuit or reverse-polarity connection before returning the inverter to service. Do not assume automatic recovery from a protection event unless it is explicitly stated above. Load Duration and Environment Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C 100% load duration 20 minutes 80% load duration 40 minutes 70% load duration 120 minutes Continuous-duty load reference 60% of rated power Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. The separate derating graph limits output to 70% of rating from 0 to 20°C and reduces it to 30% at 40°C. Its load limit must also be observed alongside the duration chart. Use the lower applicable thermal and duration limit. The continuous-duty reference is 90 W before any stricter temperature derating; the 150 W table rating and the specification-table temperature entry do not override these operating charts. Confirm the intended operating point if it falls outside their combined limits. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 165 × 94 × 69 mm Catalogue packing reference per unit 800 g (0.8 kg), from the manufacturer's PACKING entry; not a measured net or shipping-parcel weight. Use the supplied DC lead and the receptacle appropriate to this version. The body dimensions do not include a connected AC plug, DC cable bend or required ventilation clearance. The applicable catalogue page illustrates TYPE-3 Europe, TYPE-4 Universal, TYPE-5 Australia and TYPE-6 UK receptacle options. This F3 order code specifies TYPE-3; request and confirm any different factory receptacle arrangement before ordering. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ minimum at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $119.76

  • A302-150-B2

    MEAN WELL A301/302-150 series: Modified Sine Wave DC-AC Power Inverter - A302-150-B2

    MEAN WELL A302-150-B2 is a 150 W rated modified sine wave inverter with 24 VDC input and 110 VAC, 60 Hz output through one TYPE-2 US receptacle. Output is subject to the separate duration and derating limits below. Product Datasheet Download MEAN WELL A301/302-150 Datasheet (PDF) The A301/302-150 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 150 W Nominal DC input voltage 24 VDC Rated AC output voltage 110 VAC Surge output power 300 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 1 Complete order code A302-150-B2 Safety model designation A302-150 A302 identifies the 24 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 300 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. The 150 W rating is subject to the separate load-duration and temperature limits below; it is not an unlimited-duration 150 W operating guarantee. DC Input and Supplied Leads DC input range 21–30 VDC DC input current 10 A No-load input current 0.2 A Typical efficiency 82% Standard DC connection 700 mm cigarette-plug lead × 1 Fuse arrangement 10 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON indicator Cooling Free-air convection Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. Protection Low-battery alarm 20.5 ±1 V Low-battery shutdown 19.5 ±1 V Over-voltage protection range 30–32 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. A short circuit shuts off the output; automatic recovery is not specified. Remove the fault and check the inverter before returning it to service. Load Duration and Environment Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C 100% load duration 20 minutes 80% load duration 40 minutes 70% load duration 120 minutes Continuous-duty load reference 60% of rated power Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. The separate derating graph limits output to 70% of rating from 0 to 20°C and reduces it to 30% at 40°C. Its load limit must also be observed alongside the duration chart. Use the lower applicable thermal and duration limit. The continuous-duty reference is 90 W before any stricter temperature derating; the 150 W table rating and the specification-table temperature entry do not override these operating charts. Confirm the intended operating point if it falls outside their combined limits. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 122 × 73 × 45 mm Catalogue packing reference per unit 500 g The 500 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 0.5 kg; 30 pcs / 17 kg / carton. Use the supplied DC lead and the receptacle appropriate to this version. The body dimensions do not include a connected AC plug, DC cable bend or required ventilation clearance. The applicable catalogue page illustrates TYPE-1 Japan and TYPE-2 US receptacle options. This B2 order code specifies TYPE-2; request and confirm any different factory receptacle arrangement before ordering. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.

    $119.76

  • A301-150-B2

    MEAN WELL A301/302-150 series: Modified Sine Wave DC-AC Power Inverter - A301-150-B2

    MEAN WELL A301-150-B2 is a 150 W rated modified sine wave inverter with 12 VDC input and 110 VAC, 60 Hz output through one TYPE-2 US receptacle. Output is subject to the separate duration and derating limits below. Product Datasheet Download MEAN WELL A301/302-150 Datasheet (PDF) The A301/302-150 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model and AC Output Rated output power 150 W Nominal DC input voltage 12 VDC Rated AC output voltage 110 VAC Surge output power 300 W Output waveform Modified sine wave Output frequency 60 Hz ±1% AC output regulation ±10% Standard AC receptacles TYPE-2 US × 1 Complete order code A301-150-B2 Safety model designation A301-150 A301 identifies the 12 VDC input version. The B2 suffix selects the 110 VAC, 60 Hz output and the TYPE-2 US receptacle arrangement shown above. Match both input and output ratings to the intended equipment. The 300 W figure is the surge rating, not the normal load rating. No surge duration is specified for this model. Check that the connected load is suitable for a modified sine wave supply. The 150 W rating is subject to the separate load-duration and temperature limits below; it is not an unlimited-duration 150 W operating guarantee. DC Input and Supplied Leads DC input range 10–15 VDC DC input current 15 A No-load input current 0.25 A Typical efficiency 78% Standard DC connection 700 mm cigarette-plug lead × 1 Fuse arrangement 15 A × 1 Use the correct DC polarity and a connection rated for the actual current. The input ranges and low-battery protection thresholds are separate specifications; a shutdown threshold is not a guaranteed full-power input rating. The listed fuse arrangement describes this inverter and its specified leads. Do not substitute a lower-rated vehicle outlet or lead for the required battery connection. Controls, Indication and Cooling Local power control Power ON/OFF switch Status indication Green power-ON indicator Cooling Free-air convection Microprocessor-based inverter control converts the specified DC supply to modified sine wave AC output. Protection Low-battery alarm 10 ±0.5 V Low-battery shutdown 9.5 ±0.5 V Over-voltage protection range 15–17 V Over-temperature protection 60 ±5°C Output short-circuit protection Output shut-off Reverse input polarity Fuse opens Overload protection is listed as a feature. A quantitative overload trip or automatic restart characteristic is not specified for this model. A short circuit shuts off the output; automatic recovery is not specified. Remove the fault and check the inverter before returning it to service. Load Duration and Environment Specification-table working temperature 0–30°C at 100% load; 40°C at 50% load Working humidity 20–90% RH, non-condensing Storage temperature −30 to +70°C Storage humidity 10–95% RH Temperature coefficient ±0.05%/°C over 0–50°C 100% load duration 20 minutes 80% load duration 40 minutes 70% load duration 120 minutes Continuous-duty load reference 60% of rated power Install with unobstructed ventilation. Keep the inverter away from direct sunlight, heat sources, children, water, moisture, oil, grease and flammable materials. The separate derating graph limits output to 70% of rating from 0 to 20°C and reduces it to 30% at 40°C. Its load limit must also be observed alongside the duration chart. Use the lower applicable thermal and duration limit. The continuous-duty reference is 90 W before any stricter temperature derating; the 150 W table rating and the specification-table temperature entry do not override these operating charts. Confirm the intended operating point if it falls outside their combined limits. Dimensions, Installation and Receptacle Options Catalogue body reference dimensions 122 × 73 × 45 mm Catalogue packing reference per unit 500 g The 500 g value is the catalogue packing reference per unit, not a measured net weight or a shipping-parcel weight. The printed packing entry is 0.5 kg; 30 pcs / 17 kg / carton. Use the supplied DC lead and the receptacle appropriate to this version. The body dimensions do not include a connected AC plug, DC cable bend or required ventilation clearance. The applicable catalogue page illustrates TYPE-1 Japan and TYPE-2 US receptacle options. This B2 order code specifies TYPE-2; request and confirm any different factory receptacle arrangement before ordering. Safety, EMC and Reliability Safety approval EAC TP TC 004 Input-to-output insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH Manufacturer catalogue warranty 1 year MTBF, MIL-HDBK-217F at 25°C 200 k hours minimum The catalogue lists E13, EAC, CE and UKCA markings. Safety and conformity statements apply to the inverter within the manufacturer’s stated scope, not automatically to a complete vehicle or connected installation. EMI radiation: compliance with BS EN/EN55014-1 and EAC TP TC 020. EMC immunity: compliance with BS EN/EN55014-2, IEC61000-4-2 and IEC61000-4-3, and EAC TP TC 020. LVD compliance: BS EN/EN62368-1. Suitable applications listed by the manufacturer include household appliances, office equipment, portable equipment and vehicles, with power-tool applications also listed for this family. Check the load’s waveform and starting requirements before selection.