GSM Series: Medical Grade Green Power Adapter

122 products

MEAN WELL GSM18/25/36 Series Medical Power Adapters

  • Product Features
  • General Specifications
  • Series Overview
  • Ordering Information

Product Features

  • Medical Safety Certified: Compliant with IEC 60601-1 standards, featuring 2xMOPP (Means of Patient Protection) isolation.
  • Green Power Design: High efficiency up to 88% and extremely low no-load power consumption.
  • Ultra-Low Leakage Current: Engineered for medical safety with leakage current < 50µA at 264VAC.
  • Universal AC Input: Supports wide input range (80~264VAC), suitable for global medical applications.
  • Comprehensive Protection: Equipped with built-in Short circuit, Overload, and Over voltage protections with auto-recovery.
  • Rugged Reliability: High MTBF (>3800K hours) and vibration resistance; operates reliably in temperatures ranging from -25°C to +60°C.

General Specifications

Item Specification Detail
Input Voltage 80 ~ 264VAC
Operating Temp. -25°C to +60°C
Leakage Current < 50µA / 264VAC
Isolation I/P-O/P: 4KVAC (2xMOPP)
Safety Standards IEC 60601-1, ANSI/AAMI ES60601-1, CAN/CSA C22.2
MTBF ~3887K hours (Telcordia SR-332)

Series Overview

Series Rated Power Output Voltages Features
GSM18 18W 5V, 7.5V, 9V, 12V, 15V, 18V, 24V, 48V Compact, Medical Grade
GSM25 25W 5V, 7.5V, 9V, 12V, 15V, 18V, 24V, 48V Compact, Medical Grade
GSM36 36W 5V, 7.5V, 9V, 12V, 15V, 18V, 24V, 48V Compact, Medical Grade
Applications: Suitable for medical monitoring equipment, portable diagnostic devices, sleep apnea machines, and home healthcare. Various plug types (B/E/U) available.

Product Ordering Code

Component Example Description
Series GSM18 18W Medical Power Adapter
Type B / E / U Connector/Case Variant
Voltage 12 12V DC Output
Plug P1J Standard DC Plug
Example:
GSM18B12-P1J: 18W, 12V output, B-type connector configuration.
GSM36U24-P1J: 36W, 24V output, U-type connector configuration.
  • GSM60E48-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E48-P1J

    MEAN WELL GSM60E48-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 48 VDC at 1.25 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E48-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 48 VDC. Rated output current 1.25 A. Current range 0–1.25 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 90%. Model code GSM60E identifies the series and AC connection; 48 identifies 48 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 18 AWG; 1500 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E24-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E24-P1J

    MEAN WELL GSM60E24-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 24 VDC at 2.5 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E24-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 24 VDC. Rated output current 2.5 A. Current range 0–2.5 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88%. Model code GSM60E identifies the series and AC connection; 24 identifies 24 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 18 AWG; 1500 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E18-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E18-P1J

    MEAN WELL GSM60E18-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 18 VDC at 3.33 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E18-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 18 VDC. Rated output current 3.33 A. Current range 0–3.33 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88%. Model code GSM60E identifies the series and AC connection; 18 identifies 18 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E15-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E15-P1J

    MEAN WELL GSM60E15-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 15 VDC at 4 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E15-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 15 VDC. Rated output current 4 A. Current range 0–4 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88%. Model code GSM60E identifies the series and AC connection; 15 identifies 15 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E12-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E12-P1J

    MEAN WELL GSM60E12-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 12 VDC at 4.5 A with a 54 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E12-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 12 VDC. Rated output current 4.5 A. Current range 0–4.5 A. Rated output power, maximum 54 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88%. Model code GSM60E identifies the series and AC connection; 12 identifies 12 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E09-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E09-P1J

    MEAN WELL GSM60E09-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 9 VDC at 5.5 A with a 49.5 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E09-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 9 VDC. Rated output current 5.5 A. Current range 0–5.5 A. Rated output power, maximum 49.5 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 87%. Model code GSM60E identifies the series and AC connection; 09 identifies 9 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E07-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E07-P1J

    MEAN WELL GSM60E07-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 7.5 VDC at 6 A with a 45 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E07-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 7.5 VDC. Rated output current 6 A. Current range 0–6 A. Rated output power, maximum 45 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 85%. Model code GSM60E identifies the series and AC connection; 07 identifies 7.5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60E05-P1J

    MEAN WELL GSM60E series: Medical Wall-Mounted AC/DC Power Adapter - GSM60E05-P1J

    MEAN WELL GSM60E05-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 5 VDC at 6 A with a 30 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60E Datasheet (PDF) The GSM60E section is on PDF pages 69, 70, 71, 72, 73. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60E05-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 5 VDC. Rated output current 6 A. Current range 0–6 A. Rated output power, maximum 30 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 80%. Model code GSM60E identifies the series and AC connection; 05 identifies 5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 71. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 71. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. These are customer-requested factory DC-plug configurations. This GSM60E catalogue lists no quick-adapter availability or current-rating table; confirm the exact assembly and its rating before selecting an alternative, rather than assuming interchangeability with another series. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards TUV EN60601-1 and EN60601-1-11; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN55011 and EN60601-1-2. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–6 GHz. EFT, EN61000-4-4 Level 3: 2 kV line-to-line and 1 kV interconnect lines at 100 kHz. Surge, EN61000-4-5 Level 3, 2 kV line-to-line. Conducted RF, EN61000-4-6 Level 2, 3 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2018-08-07; combined PDF pages 69–73. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U48-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U48-P1J

    MEAN WELL GSM60U48-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 48 VDC at 1.25 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U48-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 48 VDC. Rated output current 1.25 A. Current range 0–1.25 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 90%. Model code GSM60U identifies the series and AC connection; 48 identifies 48 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 18 AWG; 1500 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. Keep the load within both this model’s 1.25 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U24-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U24-P1J

    MEAN WELL GSM60U24-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 24 VDC at 2.5 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U24-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 24 VDC. Rated output current 2.5 A. Current range 0–2.5 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88%. Model code GSM60U identifies the series and AC connection; 24 identifies 24 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 18 AWG; 1500 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. Keep the load within both this model’s 2.5 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U18-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U18-P1J

    MEAN WELL GSM60U18-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 18 VDC at 3.33 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U18-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 18 VDC. Rated output current 3.33 A. Current range 0–3.33 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88%. Model code GSM60U identifies the series and AC connection; 18 identifies 18 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. Keep the load within both this model’s 3.33 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U15-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U15-P1J

    MEAN WELL GSM60U15-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 15 VDC at 4 A with a 60 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U15-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 15 VDC. Rated output current 4 A. Current range 0–4 A. Rated output power, maximum 60 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88%. Model code GSM60U identifies the series and AC connection; 15 identifies 15 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. Keep the load within both this model’s 4 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U12-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U12-P1J

    MEAN WELL GSM60U12-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 12 VDC at 4.5 A with a 54 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U12-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 12 VDC. Rated output current 4.5 A. Current range 0–4.5 A. Rated output power, maximum 54 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88%. Model code GSM60U identifies the series and AC connection; 12 identifies 12 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level VI. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. Keep the load within both this model’s 4.5 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U09-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U09-P1J

    MEAN WELL GSM60U09-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 9 VDC at 5.5 A with a 50 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U09-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 9 VDC. Rated output current 5.5 A. Current range 0–5.5 A. Rated output power, maximum 50 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 87%. Model code GSM60U identifies the series and AC connection; 09 identifies 9 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. This model supplies up to 5.5 A. A P3A, P3B or P3C 5 A quick adapter cannot carry its full rated output: limit the load to 5 A or use a compatible connector assembly rated for the required current. The power supply does not increase an accessory current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U07-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U07-P1J

    MEAN WELL GSM60U07-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 7.5 VDC at 6 A with a 45 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U07-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 7.5 VDC. Rated output current 6 A. Current range 0–6 A. Rated output power, maximum 45 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 85%. Model code GSM60U identifies the series and AC connection; 07 identifies 7.5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. This model supplies up to 6 A. A P3A, P3B or P3C 5 A quick adapter cannot carry its full rated output: limit the load to 5 A or use a compatible connector assembly rated for the required current. The power supply does not increase an accessory current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM60U05-P1J

    MEAN WELL GSM60U series: Medical Wall-Mounted AC/DC Power Adapter - GSM60U05-P1J

    MEAN WELL GSM60U05-P1J is a Class II medical wall-mounted power adapter with fixed two-pin US mains plug, supplying 5 VDC at 6 A with a 30 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM60U Datasheet (PDF) The GSM60U section is on PDF pages 64, 65, 66, 67, 68. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM60U05-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 5 VDC. Rated output current 6 A. Current range 0–6 A. Rated output power, maximum 30 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 80%. Model code GSM60U identifies the series and AC connection; 05 identifies 5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin US mains plug. AC current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Set-up / rise time, full load 1000 / 100 ms at either 230 or 115 VAC. Hold-up time, full load 10 ms at either 230 or 115 VAC. No-load consumption <0.15 W. Energy framework Energy-efficiency Level V. The series lists US EISA 2007/DoE, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <100 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 5656 VDC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–160% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp with output short. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −30 to +70°C; apply derating. Temperature/load curve 100% load from −30°C to 40°C; the graph marks 70% at 50°C and 50% at 70°C. Low-input load curve 80% at 80 VAC, reaching 100% at 115 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 66. Mechanical Details and Cable Body dimensions, L × W × H 75.5 × 32 × 47.5 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL2468, 16 AWG; 1000 mm, +150/−0 mm. Catalogue single-unit weight 200 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 13 kg. Enclosure protection IP22, as marked in the catalogue. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 66. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives have no quick-adapter accessory listed. This model supplies up to 6 A. A P3A, P3B or P3C 5 A quick adapter cannot carry its full rated output: limit the load to 5 A or use a compatible connector assembly rated for the required current. The power supply does not increase an accessory current rating. Stripped and tinned leads are available by request: lead 1, ribbed, is +Vo; lead 2, letter-marked, is −Vo. The standard drawing marks L = 25 mm and L1 = 10 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards ANSI/AAMI ES60601-1 and ES60601-1-11, version 3.1; CAN/CSA C22.2 No.60601-1, third edition. Conducted / radiated emissions FCC Part 18, Class B. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2022-04-15; combined PDF pages 64–68. Minimum MTBF 400 thousand hours by MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day; this condition is distinct from the manufacturer warranty. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Load regulation is measured from 10% to 100% rated load. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices, including sleep-apnea devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

    $102.51

  • GSM36E48-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E48-P1J

    MEAN WELL GSM36E48-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 48 VDC at 0.75 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E48-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 48 VDC. Rated output current 0.75 A. Current range 0–0.75 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 240 mVp-p. Voltage tolerance ±2%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88%. Model code GSM36E identifies the series and AC connection; 48 identifies 48 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 50.4–64.8 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1800 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 0.75 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E24-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E24-P1J

    MEAN WELL GSM36E24-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 24 VDC at 1.5 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E24-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 24 VDC. Rated output current 1.5 A. Current range 0–1.5 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±2%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 87%. Model code GSM36E identifies the series and AC connection; 24 identifies 24 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 25.2–32.4 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1800 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 1.5 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E18-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E18-P1J

    MEAN WELL GSM36E18-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 18 VDC at 2 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E18-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 18 VDC. Rated output current 2 A. Current range 0–2 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 87%. Model code GSM36E identifies the series and AC connection; 18 identifies 18 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 18.9–25.2 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1800 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 2 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E15-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E15-P1J

    MEAN WELL GSM36E15-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 15 VDC at 2.4 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E15-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 15 VDC. Rated output current 2.4 A. Current range 0–2.4 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 87%. Model code GSM36E identifies the series and AC connection; 15 identifies 15 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 15.75–20.25 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1800 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 2.4 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E12-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E12-P1J

    MEAN WELL GSM36E12-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 12 VDC at 3 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E12-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 12 VDC. Rated output current 3 A. Current range 0–3 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 86%. Model code GSM36E identifies the series and AC connection; 12 identifies 12 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level VI. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 12.6–17.2 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1800 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 3 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E09-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E09-P1J

    MEAN WELL GSM36E09-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 9 VDC at 4 A with a 36 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E09-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 9 VDC. Rated output current 4 A. Current range 0–4 A. Rated output power, maximum 36 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 84%. Model code GSM36E identifies the series and AC connection; 09 identifies 9 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 9.45–13 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1200 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 4 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E07-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E07-P1J

    MEAN WELL GSM36E07-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 7.5 VDC at 4.32 A with a 32.4 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E07-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 7.5 VDC. Rated output current 4.32 A. Current range 0–4.32 A. Rated output power, maximum 32.4 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 83%. Model code GSM36E identifies the series and AC connection; 07 identifies 7.5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 7.88–10.5 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1200 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 4.32 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.

  • GSM36E05-P1J

    MEAN WELL GSM36E series: Medical Wall-Mounted AC/DC Power Adapter - GSM36E05-P1J

    MEAN WELL GSM36E05-P1J is a Class II medical wall-mounted power adapter with fixed two-pin European mains plug, supplying 5 VDC at 4.5 A with a 22.5 W rated maximum output. Its center-positive P1J plug, 2 × MOPP isolation and BF-rated design support the stated medical applications. Apply the input and ambient-temperature derating. Product Datasheet Download MEAN WELL GSM36E Datasheet (PDF) The GSM36E section is on PDF pages 59, 60, 61, 62, 63. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model GSM36E05-P1J. Product type Single-output Class II medical wall-mounted AC/DC power adapter. Nominal output 5 VDC. Rated output current 4.5 A. Current range 0–4.5 A. Rated output power, maximum 22.5 W; apply the current, voltage and derating limits together. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6%. Line regulation ±1%. Load regulation ±6%. Efficiency, typical 80%. Model code GSM36E identifies the series and AC connection; 05 identifies 5 V; P1J is the standard center-positive tuning-fork DC plug. Select the complete model and match the equipment voltage, current and polarity. The nominal series wattage is not the output rating of every model. Input, Timing and Efficiency AC input 80–264 VAC, 47–63 Hz. DC input 113–370 VDC. AC connection Fixed two-pin European mains plug. AC current, typical 0.9 A at 115 VAC; 0.45 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 55 A at 230 VAC. Set-up / rise time, full load 500 / 30 ms at 230 VAC; 1000 / 30 ms at 115 VAC. Hold-up time, full load Typical 16 ms at 230 VAC and 10 ms at 115 VAC. No-load consumption <0.1 W. Energy framework Energy-efficiency Level V. EU ErP and CoC Version 5 are listed, with the 5–9 V Level V exception. The two-pole mains plug is integral to the adapter. Select the US or European plug configuration for the intended socket. Medical Isolation and Protection Medical design 2 × MOPP primary-to-secondary isolation; BF-rated design and the listed home-healthcare standards. Touch current <50 µA at 264 VAC. Electrical class Class II; no protective-earth connection. Input/output withstand 4 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, input-to-output. Overload 105–170% of rated output power; hiccup mode with automatic recovery after the fault is removed. Overvoltage 5.25–7.5 V; output shutdown, re-power on to recover. Short circuit Short-circuit protection is listed. The adapter supports the stated medical application class; safety and EMC of the complete medical equipment still require assessment with its actual load, wiring and installation. Environment and Derating Operating temperature −25 to +60°C; apply derating. Temperature/load curve Horizontal mounting: 100% load from −25°C to 40°C, then reduce to 80% at 60°C. Low-input load curve 80% at 80 VAC, reaching 100% at 100 VAC and remaining at 100% to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each of X, Y and Z. Follow both input-voltage and ambient-temperature limits. The upper operating temperature is a derated endpoint, not a full-power ambient rating. Refer to the applicable curves on PDF page 61. Mechanical Details and Cable Body dimensions, L × W × H 79 × 54 × 33 mm; tolerance ±1 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic. DC cable UL1185, 16 AWG; 1200 mm, ±50 mm. Catalogue single-unit weight 230 g, from the explicit PACKING per-unit value; a catalogue packing reference, not a measured net or shipping weight. Carton packing 60 pieces / 14.8 kg. Power indication Power-on LED. Ferrite-to-plug segment 70 ±10 mm, as shown in the mechanical drawing. Mains-pin projection The drawing marks 38 mm beyond the body. Body dimensions exclude the attached DC cable and plug and the projecting mains pins. Allow room for the cable exit and connector; follow PDF page 61. Standard P1J Output Connection Connector Straight tuning-fork barrel plug P1J: 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ±0.5 mm insertion length. Polarity C+: center/inside positive; outside negative. Match the mating socket dimensions, insertion depth, polarity and voltage before connection. A mechanically fitting plug does not make different output models interchangeable. Optional DC Plugs and Accessories Tuning-fork alternatives P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Barrel alternatives P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Locking alternatives P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. Minimum-pin alternatives P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent. Center-pin alternatives P4A: 5.5 / 3.4 / 11 mm, center pin 1.0 mm; P4B: 6.5 / 4.4 / 11 mm, center pin 1.4 mm; P4C: 7.4 / 5.1 / 11 mm, center pin 0.6 mm. EIAJ equivalent. R6B Locking three-pin male Mini DIN, KYCON KPPX-3P equivalent: pins 1 and 3 +Vo, pin 2 −Vo. R7B Locking four-pin male Mini DIN, KYCON KPPX-4P equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R7BF Locking four-pin female Mini DIN, KYCON KPJX-CM-4S equivalent: pins 1 and 4 +Vo, pins 2 and 3 −Vo. R1B Male five-pin DIN: pins 1, 2 and 4 −Vo; pins 3 and 5 +Vo. All optional plug dimensions are in mm. Codes ending in R in the P1/P2 lists indicate the illustrated right-angle version; the other P1/P2 barrel forms are straight. Confirm the complete cable assembly, mating side and current capability when ordering. No mating socket or optional cable is stated as included. Factory DC-plug customization is subject to a minimum order quantity. The listed quick-adapter accessories are sold separately without a minimum order quantity. The tuning-fork alternatives, P4A/P4B/P4C, R6B and R7B and R1B have 7.5 A maximum quick-adapter ratings; P3A/P3B/P3C quick adapters are limited to 5 A. Barrel and locking alternatives, R7BF have no quick-adapter accessory listed. Keep the load within both this model’s 4.5 A output rating and the selected accessory’s current rating. Stripped and tinned leads are available by request: lead 1 red is +Vo and lead 2 black is −Vo; colours are reference only and must be verified on the actual assembly. The standard drawing marks L = 25 mm and L1 = 5 mm. Both lengths can be specified by request; no complete separate ordering code is printed for this lead option. Safety and EMC Listed safety standards IEC60601-1:2005+A1+A2 and IEC60601-1-11:2015+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2 and BS EN/EN60601-1-11:2015+A1; EAC TP TC 004. Conducted / radiated emissions EN55011 (CISPR11), Class B. Harmonic current / flicker EN61000-3-2, Class A; EN61000-3-3. Immunity framework EN60601-1-2 and EN61204-3. ESD, EN61000-4-2 Level 4: 15 kV air and 8 kV contact. Radiated RF, EN61000-4-3 Level 3: 10 V/m, 80 MHz–2.7 GHz; Table 9 also lists 9–28 V/m over 385 MHz–5.78 GHz. EFT, EN61000-4-4 Level 3, 2 kV. Surge, EN61000-4-5 Level 3, 1 kV line-to-line. Conducted RF, EN61000-4-6 Level 3, 10 V. Magnetic field, EN61000-4-8 Level 4, 30 A/m. Voltage dips / interruptions, EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. Use the standards listed for this exact US, European or desktop configuration; do not transfer certification or immunity claims from another adapter variant. Final equipment compliance must be checked with its actual cable and load. Measurement Conditions and Reliability General measurement conditions Unless otherwise specified: 230 VAC, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2026-04-03; combined PDF pages 59–63. Minimum MTBF 3777.8 thousand hours by Telcordia SR-332; 651.4 thousand hours by MIL-HDBK-217F at 25°C. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. Set-up time is measured at the first cold start; repeated on/off switching may increase it. Application and Selection Examples include blood glucose meters, blood pressure meters, nebulizers, inhalers and portable medical devices. Select this exact mains-plug version and output rating for the equipment. Check the matching socket and all applicable safety requirements before installation.


You have seen 24 out of 122 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa