LCM Series: Constant Current LED Driver

122 products

MEAN WELL LCM Series Smart LED Drivers

MEAN WELL LCM Series Smart LED Drivers

  • Product Features
  • Technical Specifications
  • Current Range
  • Smart Control Options

Product Features

The LCM series is a highly versatile, multi-stage Constant Current (CC) LED driver. Engineered for commercial indoor lighting, its unique design allows installers to drastically reduce inventory by using a single driver model to support multiple LED fixture types.

  • DIP Switch Selectable Current: Output current levels can be easily configured via a built-in DIP switch, making it adaptable to various LED modules and reducing stock complexity.
  • Flicker-Free Output: Provides a pure, stable, and ripple-free constant current to ensure high visual comfort and compliance with indoor health standards.
  • IoT & Wireless Integration: Advanced variants (EO) feature integrated EnOcean (868MHz) wireless technology, enabling seamless, battery-free smart lighting control.
  • Synchronization Function: A unique sync capability allows up to 10 units to be daisy-chained and controlled simultaneously from a single master dimming signal, eliminating complex wiring.
  • Auxiliary Power & Robust Design: 40W and 60W models include a 12V/50mA auxiliary DC output to power fans or sensors. The series uses a Class II, IP20 plastic housing with screwless push-in terminals for rapid, secure installation.

Technical Specifications

Parameter Specification Detail
Input Voltage 180 ~ 295VAC (High-line optimization)
Output Mode Constant Current (CC) - Multiple-stage
PFC Function Active PFC, PF > 0.95 at full load
Standby Power < 0.5W
Synchronization Up to 10 units daisy-chained via sync cable
Safety Standards ENEC, CE, CB, UKCA, UL (Global approvals)

Power & Current Range Overview

The LCM series is optimized for standard commercial lighting wattages.

Model Series Rated Power Selectable Current Range (via DIP Switch)
LCM-25 25W 350mA, 500mA, 600mA, 700mA, 900mA, 1050mA
LCM-40 40W 350mA, 500mA, 600mA, 700mA, 900mA, 1050mA
LCM-60 60W 500mA, 600mA, 700mA, 900mA, 1050mA, 1400mA
Application Note: The Constant Power architecture allows the driver to automatically adjust voltage based on your LED string's forward voltage requirements, provided the current selection is correct. Ideal for LED panels, downlights, troffers, and architectural lighting.

Dimming & Smart Control Protocols

The LCM family supports traditional wired dimming as well as cutting-edge wireless IoT protocols for advanced building automation.

Suffix Control Protocol Best Usage
Blank 3-in-1 Dimming 0~10V, PWM, or Resistor. Perfect for traditional commercial wall dimmers.
DA/DA2 DALI / DALI-2 Fully addressable networks. Includes "Push Dim" for simple switch-based control.
EO EnOcean Battery-free wireless control. Pairs with kinetic switches for heritage or glass buildings.
KN KNX Direct integration into KNX building automation with Data Secure.
BLE/TY1 Bluetooth Mesh App-based control (Casambi/Tuya). Ideal for wireless retrofits.
Installation Tip: When using the synchronization feature, only the "Master" unit needs to be connected to the dimming signal (e.g., DALI or 0-10V). The master then controls all chained "Slave" units, significantly reducing the amount of control wiring required on site.
  • LCM-40TW

    MEAN WELL LCM-40TW series: DALI-2 tunable-white LED driver - LCM-40TW

    LCM-40TW tunable-white LED driver MEAN WELL LCM-40TW is a two-channel, 40 W maximum-total-output LED driver for tunable-white lighting, with DALI-2 DT8 control, selectable DT6 modes and PUSH dimming. CH1 is cool white and CH2 is warm white; both channels share the 40 W power limit. The factory current setting is 700 mA. Download MEAN WELL LCM-40TW Datasheet (PDF)Download MEAN WELL LCM-40TW Installation Manual LCM catalog, PDF pages 83–89. Match the current-setting voltage window and total power across both channels. Output and current settings Output configuration Two constant-current channels within a constant-power output envelope. Overall CH1/CH2 range 20–50 V; maximum no-load voltage 53 V. Maximum combined output 40 W, not 40 W per channel. Current selection 500–1050 mA by physical DIP switches. Below, positions 1/2/3 select current; positions 4/5 select the operating mode. Do not exceed the LED module’s rated current or the 40 W combined limit. 500 mA setting 27–50 V; DIP 1/2/3 = OFF/ON/ON or ON/ON/ON. 600 mA setting 25–50 V; DIP 1/2/3 = OFF/OFF/ON or ON/OFF/ON. 700 mA setting — default 20–50 V; DIP 1/2/3 = ON/ON/OFF. 800 mA setting 20–50 V; DIP 1/2/3 = OFF/ON/OFF. 900 mA setting 20–44 V; DIP 1/2/3 = ON/OFF/OFF. 1050 mA setting 20–38 V; DIP 1/2/3 = OFF/OFF/OFF. Dimming and ripple 0–100% output, including off; minimum dimming level 0.2%. The available color-temperature adjustment window narrows at very low brightness: use the catalog CCT/output-current chart rather than assuming full color range at every low level. Ripple <2%, measured at 50–100% of maximum output voltage and under rated power. Standby power <0.5 W in dimming-off state, measured at 180–230 VAC input. Input and electrical performance Input voltage and frequency 180–277 VAC, 47–63 Hz; normal DC input 260–390 VDC. The separate emergency-lighting DC scope is stated below. Power factor and harmonics Built-in active PFC. Power factor ≥0.98 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <10% at the catalog’s stated load conditions: 50% at 230 VAC and 75% at 277 VAC. Typical efficiency 87% at 800 mA / 50 V. Typical input current 0.23 A at 230 VAC. Setup time 500 ms at 230 VAC, measured at first cold start; repeated ON/OFF operation can increase setup time. A DALI controller supporting the DALI power-on function is needed for the 0.5-second setup; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush current Cold-start inrush 20 A at 230 VAC; width 310 µs at 50% Ipeak, per NEMA 410. Leakage current <0.75 mA at 277 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, rising to 100% at 200 VAC; operate within the specified 277 VAC maximum input. DALI modes and PUSH control DIP 4/5 — DT6 single address OFF/ON: one DALI address, CH1 active. DIP 4/5 — DT6 dual address ON/ON: two DALI addresses, CH1 and CH2 active. DIP 4/5 — DT8 default OFF/OFF or ON/OFF: one DALI address with tunable-white control, CH1 and CH2 active. Factory mode is DT8. DALI interface DALI-2 with DT6 and DT8. Standards: IEC 62386-101, -102, -207 (DT6), -209 (DT8), -251. PUSH wiring For PUSH mode, connect a button between DA+/PUSH and AC/L, and connect DA−/N to AC/N. For DALI mode, connect the DALI bus to DA+ and DA− instead; do not connect the bus to the mains-wired PUSH arrangement. PUSH timing and limits Short push 0.1–1 s: on/off. Double click: two clicks within 1.5 s. Long push: 1.5–10 s. Pushes shorter than 0.05 s cause no change. Factory dimming level 100%. Maximum 10 drivers per button; button-to-last-driver cable length ≤20 m. DT6 PUSH behavior Single-address DT6: double click returns to maximum brightness; long push changes brightness. Dual-address DT6: double click returns to maximum brightness; long push makes the output brighter and cooler, or dimmer and warmer. DT8 PUSH behavior Double click alternates brightness and color-temperature control; long push adjusts the selected function. Long-push dimming stops at its minimum rather than switching off, reverses direction at the next long push, and can increase brightness from standby. Protection and operating conditions Overload protection 105–135% of rated power; hiccup mode with automatic recovery after the fault is removed. Short-circuit protection Constant-current limiting; automatic recovery after the fault is removed. Overtemperature protection Stage 1 reduces output to 70% load; stage 2 shuts down output. Automatic recovery follows removal of the overtemperature condition. Case temperature Working Tcase −30 to +85°C; maximum case temperature +85°C. Cooling/load derating Free-air convection, horizontal mounting. The ambient curve allows full load from −30 to +45°C and ends there. The Tcase curve allows full load through +85°C and ends there. Do not extrapolate either curve into a higher-temperature operating region. Altitude Catalog operating altitude 2,000 m. Its derating note requires a 3.5°C reduction in allowable ambient temperature for every additional 1,000 m above 2,000 m in fanless use. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and installation Construction and safety Class II plastic enclosure with no FG connection; SELV; flicker-free design complying with IEEE 1789. ENEC BS EN/EN 61347-1 and 61347-2-13, including EL Appendix J; BS EN/EN 62384 independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004; BIS IS 15885 (Part 2/Sec 13). Emergency-lighting scope The catalog’s EL scope is AC input 200–240 VAC and DC input 180–260 VDC. This emergency-lighting condition is separate from the normal 260–390 VDC input range. Insulation tests I/P–O/P withstand 3.75 kVAC. Insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at the stated 50% load condition; BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level, line-to-line surge 2 kV. Reconfirm EMC in final equipment. Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Case LCM-60A. Top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; side-view tabs marked 2 × Ø4 mm. Follow the drawing and horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+/PUSH, 4 DA−/N. TB2: 1 +V, 2 +V, 3 −V1 (CH1 cool white), 4 −V2 (CH2 warm white). Installation Disconnect power before wiring or changing DIP settings. Connect both LED strings with the indicated shared-positive polarity, and keep combined channel power within 40 W. Use the exact DALI or PUSH wiring diagram and the linked installation manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2111.7K hours under Telcordia SR-332; 177.4K hours under MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 5 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 85°C. AUX, NTC and synchronization terminals are not provided on this model. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 26; C10: 27; C16: 44. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

  • LCM-40TW

    MEAN WELL LCM-40TW series: DALI-2 tunable-white LED driver - LCM-40TW

    LCM-40TW tunable-white LED driver MEAN WELL LCM-40TW is a two-channel, 40 W maximum-total-output LED driver for tunable-white lighting, with DALI-2 DT8 control, selectable DT6 modes and PUSH dimming. CH1 is cool white and CH2 is warm white; both channels share the 40 W power limit. The factory current setting is 700 mA. Download MEAN WELL LCM-40TW Datasheet (PDF)Download MEAN WELL LCM-40TW Installation Manual LCM catalog, PDF pages 83–89. Match the current-setting voltage window and total power across both channels. Output and current settings Output configuration Two constant-current channels within a constant-power output envelope. Overall CH1/CH2 range 20–50 V; maximum no-load voltage 53 V. Maximum combined output 40 W, not 40 W per channel. Current selection 500–1050 mA by physical DIP switches. Below, positions 1/2/3 select current; positions 4/5 select the operating mode. Do not exceed the LED module’s rated current or the 40 W combined limit. 500 mA setting 27–50 V; DIP 1/2/3 = OFF/ON/ON or ON/ON/ON. 600 mA setting 25–50 V; DIP 1/2/3 = OFF/OFF/ON or ON/OFF/ON. 700 mA setting — default 20–50 V; DIP 1/2/3 = ON/ON/OFF. 800 mA setting 20–50 V; DIP 1/2/3 = OFF/ON/OFF. 900 mA setting 20–44 V; DIP 1/2/3 = ON/OFF/OFF. 1050 mA setting 20–38 V; DIP 1/2/3 = OFF/OFF/OFF. Dimming and ripple 0–100% output, including off; minimum dimming level 0.2%. The available color-temperature adjustment window narrows at very low brightness: use the catalog CCT/output-current chart rather than assuming full color range at every low level. Ripple <2%, measured at 50–100% of maximum output voltage and under rated power. Standby power <0.5 W in dimming-off state, measured at 180–230 VAC input. Input and electrical performance Input voltage and frequency 180–277 VAC, 47–63 Hz; normal DC input 260–390 VDC. The separate emergency-lighting DC scope is stated below. Power factor and harmonics Built-in active PFC. Power factor ≥0.98 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <10% at the catalog’s stated load conditions: 50% at 230 VAC and 75% at 277 VAC. Typical efficiency 87% at 800 mA / 50 V. Typical input current 0.23 A at 230 VAC. Setup time 500 ms at 230 VAC, measured at first cold start; repeated ON/OFF operation can increase setup time. A DALI controller supporting the DALI power-on function is needed for the 0.5-second setup; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush current Cold-start inrush 20 A at 230 VAC; width 310 µs at 50% Ipeak, per NEMA 410. Leakage current <0.75 mA at 277 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, rising to 100% at 200 VAC; operate within the specified 277 VAC maximum input. DALI modes and PUSH control DIP 4/5 — DT6 single address OFF/ON: one DALI address, CH1 active. DIP 4/5 — DT6 dual address ON/ON: two DALI addresses, CH1 and CH2 active. DIP 4/5 — DT8 default OFF/OFF or ON/OFF: one DALI address with tunable-white control, CH1 and CH2 active. Factory mode is DT8. DALI interface DALI-2 with DT6 and DT8. Standards: IEC 62386-101, -102, -207 (DT6), -209 (DT8), -251. PUSH wiring For PUSH mode, connect a button between DA+/PUSH and AC/L, and connect DA−/N to AC/N. For DALI mode, connect the DALI bus to DA+ and DA− instead; do not connect the bus to the mains-wired PUSH arrangement. PUSH timing and limits Short push 0.1–1 s: on/off. Double click: two clicks within 1.5 s. Long push: 1.5–10 s. Pushes shorter than 0.05 s cause no change. Factory dimming level 100%. Maximum 10 drivers per button; button-to-last-driver cable length ≤20 m. DT6 PUSH behavior Single-address DT6: double click returns to maximum brightness; long push changes brightness. Dual-address DT6: double click returns to maximum brightness; long push makes the output brighter and cooler, or dimmer and warmer. DT8 PUSH behavior Double click alternates brightness and color-temperature control; long push adjusts the selected function. Long-push dimming stops at its minimum rather than switching off, reverses direction at the next long push, and can increase brightness from standby. Protection and operating conditions Overload protection 105–135% of rated power; hiccup mode with automatic recovery after the fault is removed. Short-circuit protection Constant-current limiting; automatic recovery after the fault is removed. Overtemperature protection Stage 1 reduces output to 70% load; stage 2 shuts down output. Automatic recovery follows removal of the overtemperature condition. Case temperature Working Tcase −30 to +85°C; maximum case temperature +85°C. Cooling/load derating Free-air convection, horizontal mounting. The ambient curve allows full load from −30 to +45°C and ends there. The Tcase curve allows full load through +85°C and ends there. Do not extrapolate either curve into a higher-temperature operating region. Altitude Catalog operating altitude 2,000 m. Its derating note requires a 3.5°C reduction in allowable ambient temperature for every additional 1,000 m above 2,000 m in fanless use. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and installation Construction and safety Class II plastic enclosure with no FG connection; SELV; flicker-free design complying with IEEE 1789. ENEC BS EN/EN 61347-1 and 61347-2-13, including EL Appendix J; BS EN/EN 62384 independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004; BIS IS 15885 (Part 2/Sec 13). Emergency-lighting scope The catalog’s EL scope is AC input 200–240 VAC and DC input 180–260 VDC. This emergency-lighting condition is separate from the normal 260–390 VDC input range. Insulation tests I/P–O/P withstand 3.75 kVAC. Insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C at the stated 50% load condition; BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level, line-to-line surge 2 kV. Reconfirm EMC in final equipment. Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Case LCM-60A. Top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; side-view tabs marked 2 × Ø4 mm. Follow the drawing and horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+/PUSH, 4 DA−/N. TB2: 1 +V, 2 +V, 3 −V1 (CH1 cool white), 4 −V2 (CH2 warm white). Installation Disconnect power before wiring or changing DIP settings. Connect both LED strings with the indicated shared-positive polarity, and keep combined channel power within 40 W. Use the exact DALI or PUSH wiring diagram and the linked installation manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2111.7K hours under Telcordia SR-332; 177.4K hours under MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 5 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 85°C. AUX, NTC and synchronization terminals are not provided on this model. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 26; C10: 27; C16: 44. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN-AUX

    MEAN WELL LCM-60KN series: KNX constant-current LED driver with auxiliary output - LCM-60KN-AUX

    LCM-60KN-AUX KNX LED driver MEAN WELL LCM-60KN-AUX is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60KN

    MEAN WELL LCM-60KN series: KNX constant-current LED driver - LCM-60KN

    LCM-60KN KNX LED driver MEAN WELL LCM-60KN is a 60.3 W multi-stage constant-current LED driver with KNX control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60KN Datasheet (PDF)Download MEAN WELL LCM-40/60 KNX Installation Manual LCM catalog, PDF pages 74–82. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Additional DIP settings The following additional settings are given in the KN catalog. The connected LED forward voltage must be lower than the listed maximum. Keep the total output within the rated power; rounded table limits do not increase that rating. 650 mA — additional Maximum LED voltage 83 V; DIP OFF/OFF/OFF/ON/OFF/OFF. 750 mA — additional Maximum LED voltage 80 V; DIP ON/OFF/OFF/ON/OFF/OFF. 800 mA — additional Maximum LED voltage 75 V; DIP OFF/ON/ON/OFF/OFF/OFF. 850 mA — additional Maximum LED voltage 71 V; DIP OFF/OFF/OFF/OFF/ON/OFF. 950 mA — additional Maximum LED voltage 64 V; DIP OFF/ON/ON/ON/OFF/ON. 1000 mA — additional Maximum LED voltage 60 V; DIP OFF/OFF/OFF/ON/ON/ON. 1100 mA — additional Maximum LED voltage 55 V; DIP ON/OFF/OFF/ON/ON/ON. 1150 mA — additional Maximum LED voltage 52 V; DIP OFF/ON/ON/OFF/ON/ON. 1200 mA — additional Maximum LED voltage 50 V; DIP OFF/OFF/ON/ON/ON/ON. 1250 mA — additional Maximum LED voltage 48 V; DIP ON/ON/ON/OFF/ON/ON. 1300 mA — additional Maximum LED voltage 46 V; DIP OFF/ON/ON/ON/ON/ON. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 220–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.93 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 91% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 320 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 20 units / C type 34 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation KNX configuration ETS configuration supports switching brightness/speed/delay and status, relative/absolute dimming, lamp-failure and AC/DC monitoring, power-on level, bus-failure/recovery behavior, linear/logarithmic dimming, two block functions, staircase with multi-stage timing, cyclic monitoring, 8 scenes, an operating-hours counter, five scheduled constant-light-output (CLO) divisions and power-consumption feedback. Set output current using the hardware DIP switches; these control functions do not replace current selection. KNX bus and PUSH Connect a suitable KNX bus to the KNX terminals. The KNX bus must remain connected when using PUSH dimming or AC/DC monitoring. For PUSH, connect the button between PUSH and AC/L; never connect that button to AC/N, which can cause a short circuit. PUSH grouping Maximum button-to-last-driver cable length: 20 m. Up to 10 drivers may be controlled by one local pushbutton. ETS may define separate independent groups; this does not increase the local PUSH wiring limit. AC/DC monitoring mode Use the dedicated monitoring diagram: PUSH and L connect to AC/L or backup DC+, while N connects to AC/N or DC−. This is the monitoring configuration, not the PUSH-button wiring configuration. Synchronization Up to 10 drivers (1 master + 9 slaves); the catalog shows a KN master with LCM-40/60 slave units. Sync dimming range 6–100%; minimum dimming depends on the database. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m and observe SYN polarity. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock KNX control, dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; BIS IS 15885 (Part 2/Sec 13); EAC TP TC 004. GB/T 19510.1 and GB/T 19510.213 are by request. KNX/EIB certified. Emergency-lighting scope Emergency-lighting (EL) requirements: BS EN/EN 50172, BS EN/EN 60598-2-22 and BS EN/EN 61347-2-13 Appendix J, with AC input 200–240 VAC. Insulation tests I/P–O/P: 3.75 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 PUSH. TB4: 1 KNX−, 2 KNX+. TB5: 1 +V, 2 −V. TB3: 1 +FAN, 2 −FAN, 3 +NTC, 4 −NTC, 5 +SYN, 6 −SYN. The fan/auxiliary output is active only on the AUX version. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 1764.2K / 190.0K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. Connection sequence Connect the LED lamps before applying AC power to avoid LED damage. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC/SYNC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. KNX commissioning Obtain the application database through ETS Online Catalogs or the manufacturer’s product catalog. Configure the actual KNX system and observe bus polarity. The current driver catalog specifies 220–392 VDC input; the older installation manual’s 220–417 VDC headline does not extend that limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 13; B16: 20; C10: 22; C16: 34. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $132.09

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2-AUX

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver with auxiliary output - LCM-60DA2-AUX

    LCM-60DA2-AUX DALI-2 LED driver MEAN WELL LCM-60DA2-AUX is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This AUX version provides a 12 V / 50 mA auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output AUX option: 12 V nominal (11.4–12.6 V), 50 mA, for an auxiliary load such as a fan. Standby power <1.2 W, measured at 180–230 VAC; AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver - LCM-60DA2

    LCM-60DA2 DALI-2 LED driver MEAN WELL LCM-60DA2 is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver - LCM-60DA2

    LCM-60DA2 DALI-2 LED driver MEAN WELL LCM-60DA2 is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver - LCM-60DA2

    LCM-60DA2 DALI-2 LED driver MEAN WELL LCM-60DA2 is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94

  • LCM-60DA2

    MEAN WELL LCM-60DA series: DALI-2 constant-current LED driver - LCM-60DA2

    LCM-60DA2 DALI-2 LED driver MEAN WELL LCM-60DA2 is a 60.3 W multi-stage constant-current LED driver with DALI-2 control, pushbutton dimming and six primary DIP current settings. Match the LED string to the selected current and voltage window; 700 mA is the factory default. This version has no auxiliary DC output. Download MEAN WELL LCM-60DA Datasheet (PDF)Download MEAN WELL LCM-40/60 DA/DA2 Installation Manual LCM catalog, PDF pages 66–73. Select the exact interface and AUX suffix when ordering. Output and DIP settings Output mode and rating Constant-current output; rated power 60.3 W. The current and voltage limits below apply together; a family wattage does not authorize extra voltage or current. Current accuracy and ripple Current tolerance ±5%; maximum current ripple 5% at rated current. Ripple is measured at 60–100% of maximum output voltage and under rated power. Current selection DIP positions are listed as 1/2/3/4/5/6; ON and OFF refer to the marked switch positions. Select a current compatible with the LED module rating before energizing. 500 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP OFF/OFF/OFF/OFF/OFF/OFF. 600 mA LED operating window 2–90 V; maximum open-circuit voltage 95 V; DIP ON/OFF/OFF/OFF/OFF/OFF. 700 mA — default LED operating window 2–86 V; maximum open-circuit voltage 95 V; DIP ON/ON/OFF/OFF/OFF/OFF. 900 mA LED operating window 2–67 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/OFF/OFF/ON. 1050 mA LED operating window 2–57 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/OFF/ON. 1400 mA LED operating window 2–42 V; maximum open-circuit voltage 73 V; DIP ON/ON/ON/ON/ON/ON. Other output currents Contact MEAN WELL for other current settings; undocumented DIP combinations are not specified here. Auxiliary output No auxiliary DC output on this exact model; the separately specified AUX version is required for that function. Standby power <0.5 W, measured at 180–230 VAC; standard non-AUX configuration. Input and electrical performance Input voltage and frequency 180–295 VAC, 47–63 Hz; 254–392 VDC. Power factor and harmonics Built-in active PFC. Power factor ≥0.975 at 230 VAC and ≥0.95 at 277 VAC, full load. THD <20% at load ≥75%. Typical efficiency 92% at 900 mA / 67 V. Typical input current 0.32 A at 230 VAC; 0.27 A at 277 VAC (typical). Setup time 500 ms at 230 VAC. Measured at first cold start; repeated ON/OFF operation can increase setup time. The 0.5-second setup requires a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 second under IEC 62386-101/102. Inrush and breaker loading Cold-start inrush 20 A at 230 VAC, width 270 µs at 50% Ipeak, per NEMA 410. Catalog maximum on a 16 A breaker at 230 VAC: B type 25 units / C type 32 units; assess actual circuit conditions. Leakage current <0.5 mA at 240 VAC. Input/load derating At 60 Hz: 80% load at 180 VAC, increasing to 100% at 200 VAC; the plotted full-load region continues to 295 VAC. Control and temperature compensation Digital dimming DALI-2 interface on DA+/DA−, with selectable linear or logarithmic dimming curve. 16 groups and 64 addresses; the first output-current dimming step is fixed at 6%. PUSH wiring For DA2 PUSH mode, connect a button between DA+ and AC/L, and connect DA− to AC/N. Use the separate DALI bus wiring for DALI-2 mode; do not connect a DALI bus to the mains-wired PUSH arrangement. PUSH operation Short push 0.1–1 s: on/off. Long push 1.5–10 s: increase/decrease brightness; the direction reverses for the next long push. Reset push >11 s: return to 100% dimming level. Pushes shorter than 0.05 s cause no change. Factory dimming level is 100%. PUSH limits Up to 10 drivers per pushbutton; maximum button-to-last-driver cable length 20 m. Synchronization Up to 10 drivers (1 master + 9 slaves), with a 10–100% synchronization range. Set all units to 100% dimming before connecting the sync cable. Use a flat 22–24 AWG (0.2–0.3 mm²) cable shorter than 5 m; minimum dimming depends on the dimmer. External NTC temperature compensation An external NTC across +NTC/−NTC senses the luminaire or its environment. Without an NTC, current follows the selected DIP setting. Reference THINKING TTC03 series: 220 kΩ keeps 100% current below 60°C, 330 kΩ below 70°C, or 470 kΩ below 80°C; above the corresponding threshold current is reduced according to the catalog curve. MEAN WELL does not supply the NTC; verify other brands against the curve. NTC/control interlock Dimming and synchronization are invalid while NTC temperature compensation is in use. Protection and operating conditions Protection Short circuit: constant-current limiting with automatic recovery after the fault is removed. Overvoltage: 105–125 V, shutdown; reapply power to recover. Overtemperature: shutdown; reapply power to recover. Case temperature Working case-temperature range −30 to +90°C; maximum Tcase +90°C. Case temperature is not ambient temperature. Cooling/load derating Free-air convection, horizontal mounting. The ambient-temperature plot labels 1050 mA and 1400 mA as full load only through +40°C, where that curve ends. The curve labelled “Others” is 100% through +50°C, falling to 60% at +60°C. Follow the matching current-setting curve; do not extrapolate beyond its endpoint. The Tcase curve is 100% through +90°C. Altitude derating For fanless operation above 2,000 m, reduce allowable ambient temperature by 3.5°C for each additional 1,000 m. Humidity and storage Operating humidity: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to +50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle, 60 minutes each along X, Y and Z axes. Safety and compliance Construction and safety Class II plastic enclosure; no FG connection; SELV. CSA C22.2 No. 250.13-12; ENEC BS EN/EN 61347-1 and 61347-2-13; BS EN/EN 62384, independent controlgear; GB/T 19510.1 and GB/T 19510.213; EAC TP TC 004. The catalog excludes DA2 from UL 8750 and BIS approvals. Emergency-lighting scope DA2 emergency-lighting (EL) requirements under BS EN/EN 61347-2-13 Appendix J apply at 200–240 VAC. DALI standards The family specification lists IEC 62386-101, -102, -207 and -251; use the exact DALI-2 interface of this model. Insulation tests I/P–O/P: 3.75 kVAC; I/P–DA: 1.5 kVAC; O/P–DA: 1.5 kVAC. I/P–O/P insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC and system integration BS EN/EN 55015; BS EN/EN 61000-3-2 Class C (load ≥40%); BS EN/EN 61000-3-3; GB/T 17743, GB/T 17625.1; EAC TP TC 020. Immunity: BS EN/EN 61000-4-2/-3/-4/-5/-6/-8/-11 and BS EN/EN 61547, light-industry level; line-to-line surge 2 kV. These are component results; reconfirm EMC in the final equipment. ErP installation condition For the catalog’s latest ErP lighting-fixture compliance condition, use the driver behind a switch rather than permanently connected to mains. Installation and reference information Dimensions and mounting 123.5 × 81.5 × 23 mm (L × W × H), tolerance ±1 mm. Use the mounting drawing: top-view Ø4.2 mm fixing holes on 110 × 68 mm centers; the side-view tabs are marked 2 × Ø4 mm. Maintain the stated horizontal cooling orientation. Terminal assignment TB1: 1 AC/L, 2 AC/N, 3 DA+, 4 DA−. TB5: 1 +V, 2 −V. TB3: 1 +FAN/+AUX, 2 −FAN/−AUX, 3 +NTC, 4 −NTC. The fan/auxiliary output is active only on the AUX version. Sync connector parts CN100/CN101: JST B2B-XH or equivalent; pins 1/3 positive and 2/4 negative. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. These are specified connector components, not an included MEAN WELL cable. Installation Disconnect power before wiring or changing DIP settings. Match LED polarity and the complete current/voltage/power envelope, and use the exact terminal diagram for this interface. Apply the installation instructions in the linked manual. Per-unit weight reference 240 g (0.24 kg), the catalog PACKING reference per unit; not a shipment weight. Reliability and warranty MTBF 2270.7K / 193.7K hours, respectively Telcordia SR-332 / MIL-HDBK-217F at 25°C. Manufacturer catalog warranty: 3 years, subject to its terms. Specification conditions Unless otherwise stated, parameters are measured at 230 VAC input, rated current and 25°C ambient. Performance plots use Tcase 80°C; the plotted examples do not replace the model limits. Manufacturer installation instructions Installation and clearance Install indoors by a qualified electrician. Keep at least 50 mm of ventilation clearance around the driver. Follow the dedicated installation manual and the model-specific load and temperature derating limits. LED load connection Do not connect a DC/DC converter or constant-current driver between this driver and the LED load. The selected output voltage and total output power must remain within the rated limits. Ambient installation limit The dedicated installation manual limits ambient temperature to 60°C. This is separate from the case-temperature rating; also obey the current model-specific load derating curve. PUSH button specification Use only a normally open pushbutton without an indicator light. Follow the model-specific PUSH-to-line diagram; never wire the PUSH button to neutral. Push-terminal wiring For AC input, LED output and the applicable PUSH/DALI push terminals, the manual specifies 14–18 AWG stranded wire, 0.823–2.08 mm², or solid-wire diameter 1.024–1.628 mm. Strip 10 mm. Suggested push-down force 3–4 kp (6.61–8.81 lbf); no screw-tightening torque is specified for these push terminals. Small screw-terminal wiring For the fitted FAN/NTC screw terminals: 22–26 AWG stranded wire, 0.129–0.326 mm², or solid-wire diameter 0.404–0.643 mm; strip 7 mm. Use a 3 mm Phillips screwdriver; recommended tightening torque 2.88 kgf·cm (2.5 lbf·in). Apply these values only to the fitted small screw terminals, not the mains/output push terminals or the KNX bus connector. Cover and tools The manual specifies a 6 mm Phillips screwdriver and 4.6 kgf·cm (4 lbf·in) for the cover screws. Its terminal-tool table specifies a 3 mm Phillips screwdriver; the connection drawing shows pressing the release button with a slotted screwdriver to insert/remove the wire. Use a suitable tool for the actual release mechanism. DALI wiring length Maximum DALI cable length 300 m, based on the manual’s stated 1.5 mm² or 14 AWG cable reference. This is separate from the 20 m PUSH-cable limit. Circuit-breaker reference Maximum units on a 230 VAC breaker according to the installation manual: B10: 15; B16: 25; C10: 27; C16: 32. These are calculated references for ABB S201 miniature circuit breakers; select protection for the actual installation.

    $107.94


You have seen 24 out of 122 products