RSP:PFC Power Supply,Single Output Power Supply

59 products

MEAN WELL RSP Series Single Output Power Supply

Power Range: 75W to 500W | Active PFC Function | High Reliability

  • Product Features
  • Specifications Overview
  • Dimensions & Details
  • Product Ordering Code

General Product Features

  • Active PFC: The RSP series is characterized by its built-in Power Factor Correction (PFC) function across all models. For the RSP-75, RSP-100, RSP-150, and RSP-500, the typical Power Factor is greater than 0.93 at 230VAC and greater than 0.98 at 115VAC at full load. For the RSP-200 and RSP-320, the typical Power Factor is greater than 0.95 at 230VAC and greater than 0.98 at 115VAC at full load.
  • AC Input Range: The RSP-75, RSP-100, RSP-150, RSP-200, and RSP-500 accept an input voltage range of 85 ~ 264VAC or 120 ~ 370VDC. However, the RSP-200 notes a range of 88 ~ 264VAC or 124 ~ 370VDC. The RSP-320 specifies an input range of 88 ~ 264VAC or 124 ~ 370VDC.
  • Safety Protections: All models within the series feature built-in protections against overload, over voltage, and over temperature conditions.
  • Control Functions: The RSP-75, RSP-100, and RSP-150 feature a remote control function (CN1: < 0~0.8VDC power on, 4~10VDC power off). The RSP-500 offers Remote Control (RC+/RC-: 0~0.8V power on; 4~10V power off), Remote Sense (compensating for load wire voltage drop up to 0.3V), and Fan Control (RTH2≥50°C fan on; RTH2≤40°C fan off; 3.3~5V fan always on, 12~48V fan on/off control).
  • Durability Testing: The power supplies are designed to withstand a 10 ~ 500Hz, 2G 10 min./1 cycle, period for 60 min. each along X, Y, Z axes vibration test.

Specifications Overview

Series Model RSP-75 RSP-100 RSP-150 RSP-200 RSP-320 RSP-500
Rated Power Up to 76.8W Up to 102.6W Up to 153.6W Up to 201.6W Up to 321.6W Up to 504W
DC Voltages Available 3.3V to 48V 3.3V to 48V 3.3V to 48V 2.5V to 48V 2.5V to 48V 3.3V to 48V
Max Efficiency (Typ.) Up to 89% Up to 88% Up to 90% Up to 90% Up to 90% Up to 90.5%

Dimensions & Environment Details

Model Dimensions (L*W*H) Working Temperature Range Operating Altitude
RSP-75 159*97*30mm -25 ~ +70°C Up to 2000m
RSP-100 179*99*30mm -30 ~ +70°C Up to 2000m
RSP-150 199*99*30mm -30 ~ +70°C Up to 2000m (EN61558); Up to 5000m (UL/IEC/EN 62368)
RSP-200 215*115*30mm -30 ~ +70°C N/A
RSP-320 215*115*30mm -30 ~ +70°C 5000m
RSP-500 230*127*40.5mm -30 ~ +70°C N/A

Product Ordering Code Breakdown

No. Item Code / Value Description
1 Series Name RSP Standard Single Output Power Supply with PFC
2 Rated Wattage 75 / 100 / 150 / 200 / 320 / 500 Approximate output power rating in Watts
3 Output Voltage 2.5 / 3.3 / 4 / 5 / 7.5 / 12 / 13.5 / 15 / 24 / 27 / 36 / 48 DC Voltage Output (Availability depends on wattage series)
Example 1: RSP-75-5 represents a 75W power supply with PFC and a 5V DC output.
Example 2: RSP-200-24 represents a 200W power supply with PFC and a 24V DC output.
Example 3: RSP-500-12 represents a 500W power supply with PFC and a 12V DC output.
  • RSP-100-5

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-5

    MEAN WELL RSP-100-5 is a single-output enclosed AC/DC power supply rated at 5 V DC, 20 A and 100 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-5 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 100 W 5 Nominal DC output voltage: 5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 5 V Rated output current 20 A Output current range 0 to 20 A Rated output power 100 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 4.75 to 5.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 86% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 5.5 to 6.75 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 45°C under the applicable input conditions High-temperature derating endpoint 60% load at 65°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-3.3

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-3.3

    MEAN WELL RSP-100-3.3 is a single-output enclosed AC/DC power supply rated at 3.3 V DC, 20 A and 66 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-3.3 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 66 W 3.3 Nominal DC output voltage: 3.3 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 3.3 V Rated output current 20 A Output current range 0 to 20 A Rated output power 66 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 3.14 to 3.63 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 83% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 3.63 to 4.46 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 45°C under the applicable input conditions High-temperature derating endpoint 60% load at 65°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-48

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-48

    MEAN WELL RSP-75-48 is a single-output enclosed AC/DC power supply rated at 48 V DC, 1.6 A and 76.8 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-48 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 76.8 W 48 Nominal DC output voltage: 48 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 48 V Rated output current 1.6 A Output current range 0 to 1.6 A Rated output power 76.8 W Maximum ripple and noise 200 mVp-p Output voltage adjustment 45.6 to 52.8 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 52.8 to 64.8 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. The IS13252 / IEC60950-1 approval statement excludes this output-voltage version; it is not claimed here. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-27

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-27

    MEAN WELL RSP-75-27 is a single-output enclosed AC/DC power supply rated at 27 V DC, 2.8 A and 75.6 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-27 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75.6 W 27 Nominal DC output voltage: 27 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 27 V Rated output current 2.8 A Output current range 0 to 2.8 A Rated output power 75.6 W Maximum ripple and noise 120 mVp-p Output voltage adjustment 25.7 to 29.7 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 88% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 29.7 to 36.45 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-24

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-24

    MEAN WELL RSP-75-24 is a single-output enclosed AC/DC power supply rated at 24 V DC, 3.2 A and 76.8 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-24 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 76.8 W 24 Nominal DC output voltage: 24 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 24 V Rated output current 3.2 A Output current range 0 to 3.2 A Rated output power 76.8 W Maximum ripple and noise 120 mVp-p Output voltage adjustment 22.8 to 26.4 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 87% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 26.4 to 32.4 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-15

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-15

    MEAN WELL RSP-75-15 is a single-output enclosed AC/DC power supply rated at 15 V DC, 5 A and 75 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-15 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75 W 15 Nominal DC output voltage: 15 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 15 V Rated output current 5 A Output current range 0 to 5 A Rated output power 75 W Maximum ripple and noise 120 mVp-p Output voltage adjustment 14.3 to 16.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 86% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 16.5 to 20.25 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-13.5

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-13.5

    MEAN WELL RSP-75-13.5 is a single-output enclosed AC/DC power supply rated at 13.5 V DC, 5.6 A and 75.6 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-13.5 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75.6 W 13.5 Nominal DC output voltage: 13.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 13.5 V Rated output current 5.6 A Output current range 0 to 5.6 A Rated output power 75.6 W Maximum ripple and noise 120 mVp-p Output voltage adjustment 12.8 to 14.9 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 85% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 14.85 to 18.23 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-12

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-12

    MEAN WELL RSP-75-12 is a single-output enclosed AC/DC power supply rated at 12 V DC, 6.3 A and 75.6 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-12 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75.6 W 12 Nominal DC output voltage: 12 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 12 V Rated output current 6.3 A Output current range 0 to 6.3 A Rated output power 75.6 W Maximum ripple and noise 120 mVp-p Output voltage adjustment 11.4 to 13.2 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 85% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 13.2 to 16.2 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-7.5

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-7.5

    MEAN WELL RSP-75-7.5 is a single-output enclosed AC/DC power supply rated at 7.5 V DC, 10 A and 75 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-7.5 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75 W 7.5 Nominal DC output voltage: 7.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 7.5 V Rated output current 10 A Output current range 0 to 10 A Rated output power 75 W Maximum ripple and noise 80 mVp-p Output voltage adjustment 7.13 to 8.25 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 84% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 8.25 to 10.13 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 40°C under the applicable input conditions High-temperature derating endpoint 60% load at 60°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-5

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-5

    MEAN WELL RSP-75-5 is a single-output enclosed AC/DC power supply rated at 5 V DC, 15 A and 75 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-5 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 75 W 5 Nominal DC output voltage: 5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 5 V Rated output current 15 A Output current range 0 to 15 A Rated output power 75 W Maximum ripple and noise 80 mVp-p Output voltage adjustment 4.75 to 5.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 82% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 5.5 to 6.75 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 40°C under the applicable input conditions High-temperature derating endpoint 60% load at 60°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-75-3.3

    MEAN WELL RSP-75 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-75-3.3

    MEAN WELL RSP-75-3.3 is a single-output enclosed AC/DC power supply rated at 3.3 V DC, 15 A and 49.5 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-75 Datasheet (PDF) The RSP-75 section is on PDF pages 1, 2, 3. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-75-3.3 RSP Single-output enclosed AC/DC power supply series with active PFC 75 Series output-power designation; this model is rated at 49.5 W 3.3 Nominal DC output voltage: 3.3 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 3.3 V Rated output current 15 A Output current range 0 to 15 A Rated output power 49.5 W Maximum ripple and noise 80 mVp-p Output voltage adjustment 3.14 to 3.63 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 76% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 0.9 A at 115 VAC; 0.5 A at 230 VAC Typical cold-start inrush 35 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 65 / 80 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 3.63 to 4.46 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -25 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 40°C under the applicable input conditions High-temperature derating endpoint 60% load at 60°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. The -25 to -20°C region is marked 230 VAC input only. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 159 × 97 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M3 L=4 mm Side mounting callout 3-M3 (both sides) L=4 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2171.5 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 296.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 440 g (0.44 kg) Carton packing reference 30 units / 14.2 kg / 0.9 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 1, 2, 3 Model specification page 2 Mechanical and curve page 3 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.