RSP:PFC Power Supply,Single Output Power Supply

59 products

MEAN WELL RSP Series Single Output Power Supply

Power Range: 75W to 500W | Active PFC Function | High Reliability

  • Product Features
  • Specifications Overview
  • Dimensions & Details
  • Product Ordering Code

General Product Features

  • Active PFC: The RSP series is characterized by its built-in Power Factor Correction (PFC) function across all models. For the RSP-75, RSP-100, RSP-150, and RSP-500, the typical Power Factor is greater than 0.93 at 230VAC and greater than 0.98 at 115VAC at full load. For the RSP-200 and RSP-320, the typical Power Factor is greater than 0.95 at 230VAC and greater than 0.98 at 115VAC at full load.
  • AC Input Range: The RSP-75, RSP-100, RSP-150, RSP-200, and RSP-500 accept an input voltage range of 85 ~ 264VAC or 120 ~ 370VDC. However, the RSP-200 notes a range of 88 ~ 264VAC or 124 ~ 370VDC. The RSP-320 specifies an input range of 88 ~ 264VAC or 124 ~ 370VDC.
  • Safety Protections: All models within the series feature built-in protections against overload, over voltage, and over temperature conditions.
  • Control Functions: The RSP-75, RSP-100, and RSP-150 feature a remote control function (CN1: < 0~0.8VDC power on, 4~10VDC power off). The RSP-500 offers Remote Control (RC+/RC-: 0~0.8V power on; 4~10V power off), Remote Sense (compensating for load wire voltage drop up to 0.3V), and Fan Control (RTH2≥50°C fan on; RTH2≤40°C fan off; 3.3~5V fan always on, 12~48V fan on/off control).
  • Durability Testing: The power supplies are designed to withstand a 10 ~ 500Hz, 2G 10 min./1 cycle, period for 60 min. each along X, Y, Z axes vibration test.

Specifications Overview

Series Model RSP-75 RSP-100 RSP-150 RSP-200 RSP-320 RSP-500
Rated Power Up to 76.8W Up to 102.6W Up to 153.6W Up to 201.6W Up to 321.6W Up to 504W
DC Voltages Available 3.3V to 48V 3.3V to 48V 3.3V to 48V 2.5V to 48V 2.5V to 48V 3.3V to 48V
Max Efficiency (Typ.) Up to 89% Up to 88% Up to 90% Up to 90% Up to 90% Up to 90.5%

Dimensions & Environment Details

Model Dimensions (L*W*H) Working Temperature Range Operating Altitude
RSP-75 159*97*30mm -25 ~ +70°C Up to 2000m
RSP-100 179*99*30mm -30 ~ +70°C Up to 2000m
RSP-150 199*99*30mm -30 ~ +70°C Up to 2000m (EN61558); Up to 5000m (UL/IEC/EN 62368)
RSP-200 215*115*30mm -30 ~ +70°C N/A
RSP-320 215*115*30mm -30 ~ +70°C 5000m
RSP-500 230*127*40.5mm -30 ~ +70°C N/A

Product Ordering Code Breakdown

No. Item Code / Value Description
1 Series Name RSP Standard Single Output Power Supply with PFC
2 Rated Wattage 75 / 100 / 150 / 200 / 320 / 500 Approximate output power rating in Watts
3 Output Voltage 2.5 / 3.3 / 4 / 5 / 7.5 / 12 / 13.5 / 15 / 24 / 27 / 36 / 48 DC Voltage Output (Availability depends on wattage series)
Example 1: RSP-75-5 represents a 75W power supply with PFC and a 5V DC output.
Example 2: RSP-200-24 represents a 200W power supply with PFC and a 24V DC output.
Example 3: RSP-500-12 represents a 500W power supply with PFC and a 12V DC output.
  • RSP-200-27

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-27

    MEAN WELL RSP-200-27 is an enclosed single-output AC/DC switching power supply rated at 27 V DC, 7.5 A and 202.5 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-27 Nominal DC output 27 V Rated output current 7.5 A Current range 0 to 7.5 A Rated output power 202.5 W Maximum ripple and noise 200 mVp-p Output voltage adjustment 26 to 31.5 V Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 32.9 to 38.3 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; Dekra EN61558-1/2-16; IEC61558-1/2-16; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 27 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 12 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-24

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-24

    MEAN WELL RSP-200-24 is an enclosed single-output AC/DC switching power supply rated at 24 V DC, 8.4 A and 201.6 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-24 Nominal DC output 24 V Rated output current 8.4 A Current range 0 to 8.4 A Rated output power 201.6 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 20 to 26.4 V Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Typical efficiency 89.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 27.6 to 32.4 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; Dekra EN61558-1/2-16; IEC61558-1/2-16; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 24 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 12 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-15

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-15

    MEAN WELL RSP-200-15 is an enclosed single-output AC/DC switching power supply rated at 15 V DC, 13.4 A and 201 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-15 Nominal DC output 15 V Rated output current 13.4 A Current range 0 to 13.4 A Rated output power 201 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 13.5 to 18 V Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Typical efficiency 89.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 18.8 to 21.8 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; Dekra EN61558-1/2-16; IEC61558-1/2-16; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 15 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 12 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-13.5

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-13.5

    MEAN WELL RSP-200-13.5 is an enclosed single-output AC/DC switching power supply rated at 13.5 V DC, 14.9 A and 201.15 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-13.5 Nominal DC output 13.5 V Rated output current 14.9 A Current range 0 to 14.9 A Rated output power 201.15 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 12 to 15 V Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 15.7 to 18.4 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; Dekra EN61558-1/2-16; IEC61558-1/2-16; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 13.5 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 12 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-12

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-12

    MEAN WELL RSP-200-12 is an enclosed single-output AC/DC switching power supply rated at 12 V DC, 16.7 A and 200.4 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-12 Nominal DC output 12 V Rated output current 16.7 A Current range 0 to 16.7 A Rated output power 200.4 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 10 to 13.2 V Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 13.8 to 16.2 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; Dekra EN61558-1/2-16; IEC61558-1/2-16; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 12 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-7.5

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-7.5

    MEAN WELL RSP-200-7.5 is an enclosed single-output AC/DC switching power supply rated at 7.5 V DC, 26.7 A and 200.25 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-7.5 Nominal DC output 7.5 V Rated output current 26.7 A Current range 0 to 26.7 A Rated output power 200.25 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 6 to 9 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 9.4 to 10.9 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 7.5 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-5

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-5

    MEAN WELL RSP-200-5 is an enclosed single-output AC/DC switching power supply rated at 5 V DC, 40 A and 200 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-5 Nominal DC output 5 V Rated output current 40 A Current range 0 to 40 A Rated output power 200 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 4.5 to 5.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 85.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2.5 A at 115 VAC; 1.3 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 5.75 to 7 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 45°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1; KN32 (5 V model only) EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 5 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-4

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-4

    MEAN WELL RSP-200-4 is an enclosed single-output AC/DC switching power supply rated at 4 V DC, 40 A and 160 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-4 Nominal DC output 4 V Rated output current 40 A Current range 0 to 40 A Rated output power 160 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 3.7 to 4.3 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 84% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2 A at 115 VAC; 1.1 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 4.5 to 5.6 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 50°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 4 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-3.3

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-3.3

    MEAN WELL RSP-200-3.3 is an enclosed single-output AC/DC switching power supply rated at 3.3 V DC, 40 A and 132 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-3.3 Nominal DC output 3.3 V Rated output current 40 A Current range 0 to 40 A Rated output power 132 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 2.97 to 3.8 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.5% Typical efficiency 81.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2 A at 115 VAC; 1.1 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 3.8 to 4.62 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 50°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1; BIS IS13252(Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. The datasheet notes that some models may not carry the BIS logo; confirm the required marking with MEAN WELL sales. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 3.3 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-200-2.5

    MEAN WELL RSP-200 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-200-2.5

    MEAN WELL RSP-200-2.5 is an enclosed single-output AC/DC switching power supply rated at 2.5 V DC, 40 A and 100 W. It accepts 88 to 264 VAC or 124 to 370 VDC and includes active power-factor correction. Cooling is by free air convection. Output availability depends on the model-specific input and temperature limits. Product Datasheet Download MEAN WELL RSP-200 Datasheet (PDF) The RSP-200 section is on PDF pages 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Specifications Complete model RSP-200-2.5 Nominal DC output 2.5 V Rated output current 40 A Current range 0 to 40 A Rated output power 100 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 2.35 to 2.85 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.5% Typical efficiency 79.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise are measured with 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the specified current and power ratings for this complete model. The series number is a family power class, not a substitute for this model-specific output rating. Apply the input-voltage and temperature derating curves. AC/DC Input, PFC and Timing AC input range 88 to 264 VAC, universal full-range input DC input range 124 to 370 VDC Input frequency 47 to 63 Hz Power-factor correction Built-in active PFC Typical power factor at full load >0.95 at 230 VAC; >0.98 at 115 VAC Typical AC input current 2 A at 115 VAC; 1.1 A at 230 VAC Typical inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Setup / rise time at full load 1500 / 50 ms at 230 VAC; 3000 / 50 ms at 115 VAC Typical hold-up time at full load 8 ms at 230 VAC and 115 VAC Input block-diagram function Active inrush-current limiting At low input voltage, reduce the output load according to the input curve. The 60 Hz graph reaches 100% load at 100 VAC and remains at 100% through 264 VAC; its 88 VAC endpoint is approximately 75%. These are graphical load limits, not extra input-voltage ratings. Protection and Recovery Listed protections Short circuit, overload, overvoltage and overtemperature Overload threshold 105 to 135% of rated output power Overload recovery Hiccup; automatic recovery after the fault is removed. Overvoltage threshold 2.88 to 3.5 V Overvoltage recovery Output shuts down; reapply power to recover. Overtemperature recovery Output shuts down; automatic recovery after the temperature falls. The overload range is a protection threshold, not an additional continuous rating or an authorized peak-power operating mode. Cooling, Operating Conditions and Derating Cooling method Free air convection Working ambient temperature -30 to +70°C, subject to derating Temperature-curve mounting orientation Horizontal Full-load temperature plateau for this model Through 50°C; reduce load above this temperature Upper-temperature curve endpoint 50% load at 70°C Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 45°C Vibration 10 to 500 Hz, 2 G; 10 min/cycle; 60 min each along X, Y and Z The upper working temperature is not a full-load rating. Apply thermal and input-voltage restrictions together and use the complete manufacturer curves for intermediate conditions. For this fanless model, apply additional ambient-temperature derating of 3.5°C per 1,000 m above 2,000 m. The RSP-200 pages do not specify a maximum operating altitude. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 215 × 115 × 30 mm Case number 207B Mechanical drawing tolerance ±1 mm Base mounting threads 4-M4 L=3mm Side mounting threads 4-M4 (Both Sides) L=5mm Base threaded-hole centre spacing 150 × 50 mm Longitudinal first-hole offset 32.5 mm Side-thread centre height 12.5 mm Mounting-tab hole centre span 135 mm Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG, protective earth Terminals 4 to 6 DC output -V Terminals 7 to 9 DC output +V Power and adjustment indication LED power-on indicator and +V ADJ control Follow the complete drawing for mounting tabs, hole positions and clearance. Thread counts and L dimensions are drawing callouts, not supplied screw quantities. Do not infer a tightening torque or conductor size from the drawing. The +V and -V groups are connections to the same single output, not independently rated output channels. Connect FG to protective earth and follow the specified AC and DC polarity. Options and Connection Scope Conformal coating Optional, as listed by the manufacturer The family pages do not provide a complete order code or suffix for the conformal-coating option. Confirm the required ordering designation before selecting it; do not assume coating is included in this standard model. No separate complete order code for a mounting bracket, terminal cover or connector kit is stated in these pages. Mounting features do not establish that such accessories are included. The documented interface is the 9-position AC/DC power terminal block. No remote ON/OFF, remote-sense or DC-OK signal connection is specified for this model in these family pages. Application Conditions For charging-related applications, consult MEAN WELL for application-specific guidance. For this model, the manufacturer strongly recommends that external output capacitance should not exceed 5,000 µF. Safety, EMC and Reliability Safety standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS60950.1 Withstand voltage I/P-O/P: 3 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH; I/P-O/P, I/P-FG and O/P-FG EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936; GB9254 Class B; GB17625.1 EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020 Minimum MTBF, Telcordia SR-332 2078.1 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 224.5 thousand hours The power supply is a component for installation in final equipment. The family EMC test note specifies a 360 × 360 × 1 mm metal plate. Reconfirm EMC compliance in the completed equipment; component approvals do not certify the whole end product. Safety and EMC statements here follow the linked datasheet revision and its model restrictions. MTBF values are reliability estimates, not a guaranteed operating life. Catalog Weight and Warranty Per-unit catalog PACKING reference 720 g (0.72 kg) Carton packing reference 15 units / 11.8 kg / 0.67 CUFT Manufacturer warranty reference 3 years The per-unit value is from the catalog PACKING row. It is not a measured net mass or an individual customer parcel weight. Manufacturer warranty terms determine actual coverage. Model Encoding and Datasheet Scope Series name RSP Family power class 200 W class; use the complete model rating above Output-voltage suffix 2.5 V Family section RSP 75–500 W combined PDF, pages 10 to 13 Model specification page 11 Datasheet revision 2025-01-10 Read the complete model-specific specifications, mechanical drawing and derating curves in the linked manufacturer PDF before installation.

  • RSP-150-48

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-48

    MEAN WELL RSP-150-48 is a single-output enclosed AC/DC power supply rated at 48 V DC, 3.2 A and 153.6 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-48 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 153.6 W 48 Nominal DC output voltage: 48 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 48 V Rated output current 3.2 A Output current range 0 to 3.2 A Rated output power 153.6 W Maximum ripple and noise 250 mVp-p Output voltage adjustment 45.6 to 52.8 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 90% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 52.8 to 64.8 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. The IS13252 / IEC60950-1 approval statement excludes this output-voltage version; it is not claimed here. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-27

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-27

    MEAN WELL RSP-150-27 is a single-output enclosed AC/DC power supply rated at 27 V DC, 5.6 A and 151.2 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-27 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 151.2 W 27 Nominal DC output voltage: 27 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 27 V Rated output current 5.6 A Output current range 0 to 5.6 A Rated output power 151.2 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 25.7 to 29.7 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 89.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 29.7 to 36.45 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; IS13252 (Part 1) / IEC60950-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-24

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-24

    MEAN WELL RSP-150-24 is a single-output enclosed AC/DC power supply rated at 24 V DC, 6.3 A and 151.2 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-24 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 151.2 W 24 Nominal DC output voltage: 24 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 24 V Rated output current 6.3 A Output current range 0 to 6.3 A Rated output power 151.2 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 22.8 to 26.4 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 26.4 to 32.4 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; IS13252 (Part 1) / IEC60950-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-15

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-15

    MEAN WELL RSP-150-15 is a single-output enclosed AC/DC power supply rated at 15 V DC, 10 A and 150 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-15 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 150 W 15 Nominal DC output voltage: 15 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 15 V Rated output current 10 A Output current range 0 to 10 A Rated output power 150 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 14.3 to 16.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 88.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 16.5 to 20.25 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; IS13252 (Part 1) / IEC60950-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-13.5

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-13.5

    MEAN WELL RSP-150-13.5 is a single-output enclosed AC/DC power supply rated at 13.5 V DC, 11.2 A and 151.2 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-13.5 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 151.2 W 13.5 Nominal DC output voltage: 13.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 13.5 V Rated output current 11.2 A Output current range 0 to 11.2 A Rated output power 151.2 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 12.8 to 14.9 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 87.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 14.85 to 18.2 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. The IS13252 / IEC60950-1 approval statement excludes this output-voltage version; it is not claimed here. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-12

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-12

    MEAN WELL RSP-150-12 is a single-output enclosed AC/DC power supply rated at 12 V DC, 12.5 A and 150 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-12 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 150 W 12 Nominal DC output voltage: 12 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 12 V Rated output current 12.5 A Output current range 0 to 12.5 A Rated output power 150 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 11.4 to 13.2 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 89% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 13.2 to 16.2 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; IS13252 (Part 1) / IEC60950-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-7.5

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-7.5

    MEAN WELL RSP-150-7.5 is a single-output enclosed AC/DC power supply rated at 7.5 V DC, 20 A and 150 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-7.5 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 150 W 7.5 Nominal DC output voltage: 7.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 7.5 V Rated output current 20 A Output current range 0 to 20 A Rated output power 150 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 7.13 to 8.25 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 88.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 8.25 to 10.13 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 40°C under the applicable input conditions High-temperature derating endpoint 60% load at 60°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. The IS13252 / IEC60950-1 approval statement excludes this output-voltage version; it is not claimed here. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-150-5

    MEAN WELL RSP-150 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-150-5

    MEAN WELL RSP-150-5 is a single-output enclosed AC/DC power supply rated at 5 V DC, 30 A and 150 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-150 Datasheet (PDF) The RSP-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-150-5 RSP Single-output enclosed AC/DC power supply series with active PFC 150 Series output-power designation; this model is rated at 150 W 5 Nominal DC output voltage: 5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 5 V Rated output current 30 A Output current range 0 to 30 A Rated output power 150 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 4.75 to 5.5 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 87% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.6 A at 115 VAC; 0.8 A at 230 VAC Typical cold-start inrush 45 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 67 / 67 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 5.5 to 6.75 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 40°C under the applicable input conditions High-temperature derating endpoint 60% load at 60°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Overvoltage category II Up to 5,000 m under UL/IEC/EN62368 Maximum operating altitude listed 5,000 m, subject to the applicable overvoltage category and altitude derating Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 199 × 99 × 30 mm Mechanical case 215A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; AS/NZS 62368.1; IS13252 (Part 1) / IEC60950-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2253.9 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 290.7 thousand hours The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 600 g (0.6 kg) Carton packing reference 24 units / 15.4 kg / 0.89 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 7, 8, 9 Model specification page 8 Mechanical and curve page 9 Specification revision 2025-09-22 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-48

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-48

    MEAN WELL RSP-100-48 is a single-output enclosed AC/DC power supply rated at 48 V DC, 2.1 A and 100.8 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-48 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 100.8 W 48 Nominal DC output voltage: 48 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 48 V Rated output current 2.1 A Output current range 0 to 2.1 A Rated output power 100.8 W Maximum ripple and noise 250 mVp-p Output voltage adjustment 45.6 to 52.8 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 88% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 52.8 to 64.8 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. The IS13252 / IEC60950-1 approval statement excludes this output-voltage version; it is not claimed here. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-27

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-27

    MEAN WELL RSP-100-27 is a single-output enclosed AC/DC power supply rated at 27 V DC, 3.8 A and 102.6 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-27 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 102.6 W 27 Nominal DC output voltage: 27 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 27 V Rated output current 3.8 A Output current range 0 to 3.8 A Rated output power 102.6 W Maximum ripple and noise 150 mVp-p Output voltage adjustment 25.7 to 29.7 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 87% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 29.7 to 36.45 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-15

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-15

    MEAN WELL RSP-100-15 is a single-output enclosed AC/DC power supply rated at 15 V DC, 6.7 A and 100.5 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-15 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 100.5 W 15 Nominal DC output voltage: 15 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 15 V Rated output current 6.7 A Output current range 0 to 6.7 A Rated output power 100.5 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 14.3 to 16.5 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 87% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 16.5 to 20.25 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-13.5

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-13.5

    MEAN WELL RSP-100-13.5 is a single-output enclosed AC/DC power supply rated at 13.5 V DC, 7.5 A and 101.25 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-13.5 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 101.25 W 13.5 Nominal DC output voltage: 13.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 13.5 V Rated output current 7.5 A Output current range 0 to 7.5 A Rated output power 101.25 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 12.8 to 14.9 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 86.5% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 14.85 to 18.23 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-12

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-12

    MEAN WELL RSP-100-12 is a single-output enclosed AC/DC power supply rated at 12 V DC, 8.5 A and 102 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-12 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 102 W 12 Nominal DC output voltage: 12 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 12 V Rated output current 8.5 A Output current range 0 to 8.5 A Rated output power 102 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 11.4 to 13.2 V Voltage tolerance ±1.0% Line regulation ±0.5% Load regulation ±0.5% Typical efficiency 86% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 13.2 to 16.2 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 50°C under the applicable input conditions High-temperature derating endpoint 60% load at 70°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.

  • RSP-100-7.5

    MEAN WELL RSP-100 series: single-output enclosed AC/DC switching power supply with active PFC - RSP-100-7.5

    MEAN WELL RSP-100-7.5 is a single-output enclosed AC/DC power supply rated at 7.5 V DC, 13.5 A and 101.25 W. It uses active PFC and free-air convection in a 30 mm-high enclosure; available load depends on input voltage and ambient temperature. Product Datasheet Download MEAN WELL RSP-100 Datasheet (PDF) The RSP-100 section is on PDF pages 4, 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model RSP-100-7.5 RSP Single-output enclosed AC/DC power supply series with active PFC 100 Series output-power designation; this model is rated at 101.25 W 7.5 Nominal DC output voltage: 7.5 V Cooling Free-air convection Enclosure profile 30 mm height The printed model encoding defines series, power designation and output voltage. It does not define a separate remote-control option suffix for this model. Remote-control connector information is listed separately below. Output Specifications Nominal DC output voltage 7.5 V Rated output current 13.5 A Output current range 0 to 13.5 A Rated output power 101.25 W Maximum ripple and noise 100 mVp-p Output voltage adjustment 7.13 to 8.25 V Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Typical efficiency 87% Unless otherwise specified, parameters are measured at 230 VAC input, rated load and 25°C ambient. Ripple and noise: 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes setup tolerance, line regulation and load regulation. Use the voltage-adjustment control shown in the mechanical drawing within the stated range. Adjustment does not authorize exceeding the listed current or power ratings. For this output-voltage version, the datasheet strongly recommends that external output capacitance should not exceed 5,000 µF. Input and Timing AC input range 85 to 264 VAC, universal full range DC input range 120 to 370 VDC Input frequency 47 to 63 Hz Typical power factor at full load >0.93 at 230 VAC; >0.98 at 115 VAC Typical AC input current 1.1 A at 115 VAC; 0.55 A at 230 VAC Typical cold-start inrush 30 A at 230 VAC Leakage current <2 mA at 240 VAC Setup / rise time 600 / 30 ms at full load Typical hold-up time 16 ms at full load PFC / PWM switching frequency 100 / 100 kHz The input-voltage derating graph is specified at 60 Hz: 80% load at 85 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply this limit together with temperature derating; the full input range is not a full-power rating at every voltage. Protection Listed protection functions Short circuit, overload, overvoltage and overtemperature Overload threshold 105% to 135% of rated output power Overload response Constant-current limiting; automatic recovery after the fault condition is removed. Overvoltage threshold 8.25 to 10.13 V Overvoltage recovery Output shutdown; reapply input power to recover. Overtemperature recovery Output shutdown; automatic recovery after temperature decreases. The overload threshold is a protection characteristic, not a continuous overload or short-duration peak-power operating rating. Operating Conditions and Derating Working ambient temperature -30 to 70 °C; apply model-specific derating Cooling Free-air convection; horizontal mounting in the derating graph Full-load temperature plateau Through 45°C under the applicable input conditions High-temperature derating endpoint 60% load at 65°C for this output-voltage group Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C; 10% to 95% RH, non-condensing Temperature coefficient ±0.05%/°C over 0 to 50°C Vibration 10 to 500 Hz; 2 G; 10 min/cycle; 60 min each along X, Y and Z axes. Overvoltage category III Up to 2,000 m under EN61558, EN50178, EN60664-1 and EN62477-1 Follow the complete temperature curve between the stated plateau and endpoint. The working-temperature range does not mean full load at every temperature; do not extend the voltage-group curve beyond its plotted endpoint. Above 2,000 m, reduce ambient-temperature limits by 3.5°C per additional 1,000 m for these fanless models. These pages specify overvoltage category III up to 2,000 m but do not state a separate maximum operating altitude. Do not extend the category III claim above 2,000 m. Dimensions, Mounting and Terminal Wiring Housing dimensions, L × W × H 179 × 99 × 30 mm Mechanical case 227A Drawing tolerance ±1 mm Base mounting callout 2-M4 L=4 mm Side mounting callout 4-M4 (both sides) L=4 mm Width including projecting mounting tabs in the top view 119 mm; distinct from the 99 mm housing width Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG (protective earth) Terminal 4 DC OUTPUT -V Terminal 5 DC OUTPUT -V Terminal 6 DC OUTPUT +V Terminal 7 DC OUTPUT +V Use the complete mechanical drawing for hole positions and clearances. Mounting callouts are not quantities of included screws. L=4 mm is the printed thread-depth callout; these pages do not specify tightening torque or wire gauge. FG is protective earth. Observe the separately assigned AC input and DC output terminals; repeated -V or +V terminals belong to the same single output. Remote Control and Optional Connector Information Remote-control function The datasheet feature list states built-in remote ON-OFF control CN1 power ON level 0 to 0.8 VDC CN1 power OFF level 4 to 10 VDC CN1 pin 1 RC+ CN1 pin 2 RC- CN1 header designation as printed JST S2B-XH or equivalent Mating housing designation as printed JST XHP or equivalent Contact-terminal designation as printed JST SXH-001T-P0.6 or equivalent The mechanical drawing marks the remote-control connector as optional. Confirm the actual connector provision before wiring; do not assume that a mating housing, crimp terminals or a cable assembly is included. The connector names above are transcribed as printed. These pages do not provide any additional pole-count suffix, exact supplied quantity, open-circuit default, permitted control current or maximum cable length. Do not complete abbreviated part numbers by borrowing codes from another series. No separate dedicated bracket, terminal-cover or cable-kit order code is specified in these pages. Use only separately verified compatible accessories; the mounting drawing alone does not establish their supply or compatibility. Safety, EMC and Reliability Safety approvals listed for this model UL62368-1; TUV BS EN/EN62368-1; BS EN/EN61558-1; BS EN/EN61558-2-16; EAC TP TC 004; CCC GB4943.1; BSMI CNS15598-1; BIS IS13252 (Part 1):2010 / IEC60950-1:2005 Withstand voltage I/P-O/P: 4 kVAC; I/P-FG: 2 kVAC; O/P-FG: 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC / 25°C / 70% RH for I/P-O/P, I/P-FG and O/P-FG. EMC emission, datasheet statement BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020; CNS15936 Class B; GB9254 Class B; GB17625.1. EMC immunity, datasheet statement BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035, light-industry level; EAC TP TC 020. Minimum MTBF, Telcordia SR-332 (Bellcore) 2325.2 thousand hours Minimum MTBF, MIL-HDBK-217F at 25°C 288.5 thousand hours AS/NZS 62368.1 statement Design reference; not listed as an approval in this specification row The power supply is a component for installation in final equipment. EMC compliance must be reconfirmed on the completed equipment. The listed approvals and standards apply to this model and datasheet revision. They do not establish compliance of an entire installation. MTBF figures are reliability-model results, not guaranteed service life or warranty duration. Catalog Weight and Product Features Per-unit catalog PACKING reference 520 g (0.52 kg) Carton packing reference 24 units / 14.5 kg / 0.81 CUFT Power indicator LED power-on indicator Application examples Factory automation, test and measurement, laser-related machines, burn-in facilities and RF equipment The per-unit figure is the catalog PACKING reference, not a measured net mass or a customer parcel weight. Carton totals must not be used as the single-product weight. The manufacturer datasheet lists a 3-year warranty; coverage is governed by the applicable manufacturer warranty terms. Datasheet Scope Series section Combined RSP catalog, PDF pages 4, 5, 6 Model specification page 5 Mechanical and curve page 6 Specification revision 2025-01-10 Refer to the linked manufacturer PDF for the complete mechanical drawing, connector information and derating curves before installation.


You have seen 48 out of 59 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa