APC Series, APV Series: Switching Power Supply

37 products

MEAN WELL APV & APC Series LED Power Supplies

  • Series Overview
  • Technical Specifications
  • Selection: APV vs APC
  • Design Benefits

Series Overview

The APV and APC series are MEAN WELL’s foundational "economical" LED power supplies. They are specifically designed for indoor LED lighting applications where compact size and cost-efficiency are critical.

  • Class II Design: These units utilize a plastic enclosure with a Class II design (no earth pin), making them safe and easy to install in a variety of indoor environments.
  • Compact Footprint: Designed for small-space integration, such as inside light boxes, small signboards, or narrow LED channels.
  • Reliable Protection: Equipped with industry-standard protections, including Short circuit, Overload, and Over voltage.
  • Convection Cooling: Fanless design ensures silent operation and high reliability without the risk of mechanical fan failure.

Technical Specifications

Parameter Specification Detail
Input Voltage 90 ~ 264VAC (Universal Input)
Cooling Free air convection (Fanless)
IP Rating IP30 (Suitable for dry indoor locations)
Safety Standards UL, CB, CE, EAC, UKCA
Operating Temp. -30°C to +70°C (Refer to derating)

Selection Guide: APV vs. APC

Understanding the difference is critical for ensuring your LED system functions correctly.

Series Mode Best For
APV Series Constant Voltage (CV) LED Strips, LED modules with built-in resistors, signage with multiple parallel LEDs.
APC Series Constant Current (CC) Direct driving of LED chips or high-power LED strings that require a specific current (mA) to operate.
Important Note: If your LED load has its own driver or resistor, use the APV (Voltage) series. If you are powering bare LEDs or strings that require a specific current limit, use the APC (Current) series.

Design Benefits

Why choose APV/APC for your project?

  • Cost-Effectiveness: These series utilize a streamlined circuit design to offer the best value for budget-conscious projects.
  • Maintenance-Free: With no moving parts like cooling fans, these units are ideal for hard-to-reach installations where maintenance would be difficult.
  • Global Versatility: The universal AC input (90-264VAC) allows these units to be deployed in almost any region in the world without modification.
  • Certifications: Despite their economical focus, they retain essential global safety certifications, ensuring compliance with building codes and international standards.
Usage Tip: Ensure adequate ventilation around the power supply. Even though they are conduction-cooled, heat buildup can shorten the lifespan of electronic components. Avoid installing them in completely sealed, unventilated boxes.
  • MEAN WELL APV-25 series: constant voltage LED power supply - APV-25-12 MEAN WELL APV-25 series: constant voltage LED power supply - APV-25-12

    MEAN WELL APV-25 series: constant voltage LED power supply - APV-25-12

    MEAN WELL APV-25-12 Constant Voltage LED Power Supply The MEAN WELL APV-25-12 is a single-output AC/DC constant voltage LED power supply providing 12 V DC, 2.1 A rated output, with a catalog rated power of 25.2 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 12 V constant-voltage operation and keep total current within 0-2.1 A and power within 25.2 W, with input and temperature derating applied. Download MEAN WELL APV-25 Datasheet (PDF) See PDF pages 8-9 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-25-12 Series and model code APV-25 is the product series. The final code 12 identifies the 12 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 12 V constant-voltage operation and keep total current within 0-2.1 A and power within 25.2 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 12 V Rated output current 2.1 A Current range 0-2.1 A Rated output power 25.2 W Ripple and noise, maximum 150 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 82% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection Above 105% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 13.8-16.2 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • MEAN WELL APC-25 series: constant current LED power supply - APC-25-500 MEAN WELL APC-25 series: constant current LED power supply - APC-25-500

    MEAN WELL APC-25 series: constant current LED power supply - APC-25-500

    MEAN WELL APC-25-500 Constant Current LED Power Supply The MEAN WELL APC-25-500 is a single-output AC/DC constant current LED power supply providing 500 mA constant current over a 15-50 V DC operating range, with a catalog rated power of 25.2 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 500 mA and having a total operating voltage within 15-50 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-25 Datasheet (PDF) See PDF pages 20-21 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-25-500 Series and model code APC-25 is the product series. The final code 500 identifies the 500 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 500 mA and having a total operating voltage within 15-50 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 500 mA Operating DC voltage range 15-50 V Catalog rated power 25.2 W; retain the 15-50 V operating window and 500 mA current limit when selecting the load. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 55-68 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Limited power source LPS is listed for this model. Class II insulation design is shown separately; these identify different safety characteristics. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • MEAN WELL APC-12 series: constant current LED power supply - APC-12-700 MEAN WELL APC-12 series: constant current LED power supply - APC-12-700

    MEAN WELL APC-12 series: constant current LED power supply - APC-12-700

    MEAN WELL APC-12-700 Constant Current LED Power Supply The MEAN WELL APC-12-700 is a single-output AC/DC constant current LED power supply providing 700 mA constant current over a 9-18 V DC operating range, with a catalog rated power of 12.6 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 700 mA and having a total operating voltage within 9-18 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-12 Datasheet (PDF) See PDF pages 15-16 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-12-700 Series and model code APC-12 is the product series. The final code 700 identifies the 700 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 700 mA and having a total operating voltage within 9-18 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 700 mA Operating DC voltage range 9-18 V Catalog rated power 12.6 W. Current accuracy ±8.0%. Voltage tolerance ±5.0%; the catalog note includes setup tolerance. This is separate from the ±8.0% output-current accuracy. Setup and rise time 3000 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 15 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.2 A at 230 VAC; 0.35 A at 115 VAC Efficiency, typical 80% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 150 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 17 units on a Type B 16 A circuit breaker, or 29 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 20.7-24.3 V; output shutoff with zener-diode clamping. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 77 x 40 x 29 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 90 mm overall length across mounting tabs and 82.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 80 g per unit (0.08 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • MEAN WELL APV-8 series: constant voltage LED power supply - APV-8-24 MEAN WELL APV-8 series: constant voltage LED power supply - APV-8-24

    MEAN WELL APV-8 series: constant voltage LED power supply - APV-8-24

    MEAN WELL APV-8-24 Constant Voltage LED Power Supply The MEAN WELL APV-8-24 is a single-output AC/DC constant voltage LED power supply providing 24 V DC, 0.34 A rated output, with a catalog rated power of 8.16 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 24 V constant-voltage operation and keep total current within 0-0.34 A and power within 8.16 W, with input and temperature derating applied. Download MEAN WELL APV-8 Datasheet (PDF) See PDF pages 2-3 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-8-24 Series and model code APV-8 is the product series. The final code 24 identifies the 24 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 24 V constant-voltage operation and keep total current within 0-0.34 A and power within 8.16 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 24 V Rated output current 0.34 A Current range 0-0.34 A Rated output power 8.16 W Ripple and noise, maximum 300 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 500 ms setup / 30 ms rise at 230 VAC; 1500 ms setup / 30 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.15 A at 230 VAC; 0.3 A at 115 VAC Efficiency, typical 81% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 120 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. No-load input power Less than 0.5 W. Protection and fault behavior Parameter Details Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overload protection Above 105% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 27.6-32.4 V; output shutoff with zener-diode clamping. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 45°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. The series description specifies 94V-0 flame-retardant plastic. Dimensions, leads and installation Parameter Details Body dimensions 60 x 30 x 23.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 73.1 mm overall length across mounting tabs and 65.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. BIS regional qualification The main BIS approval excludes the 5 V model. A separate BIS IS 15885 registration R-62002178 is listed for products made in India only; verify the actual manufacturing origin and markings rather than assuming this condition applies to every unit. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 50 g per unit (0.05 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS logos. Check the actual unit markings for the required market.

  • APC-35-1050

    MEAN WELL APC-35 series: constant current LED power supply - APC-35-1050

    MEAN WELL APC-35-1050 Constant Current LED Power Supply The MEAN WELL APC-35-1050 is a single-output AC/DC constant current LED power supply providing 1050 mA constant current over a 11-33 V DC operating range, with a catalog rated power of 34.7 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 1050 mA and having a total operating voltage within 11-33 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-35 Datasheet (PDF) See PDF pages 22-23 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-35-1050 Series and model code APC-35 is the product series. The final code 1050 identifies the 1050 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 1050 mA and having a total operating voltage within 11-33 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 1050 mA Operating DC voltage range 11-33 V Catalog rated power 34.7 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 490 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 5 units on a Type B 16 A circuit breaker, or 9 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 36-43 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Limited power source LPS is listed for this model. Class II insulation design is shown separately; these identify different safety characteristics. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-35-700

    MEAN WELL APC-35 series: constant current LED power supply - APC-35-700

    MEAN WELL APC-35-700 Constant Current LED Power Supply The MEAN WELL APC-35-700 is a single-output AC/DC constant current LED power supply providing 700 mA constant current over a 15-50 V DC operating range, with a catalog rated power of 35 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 700 mA and having a total operating voltage within 15-50 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-35 Datasheet (PDF) See PDF pages 22-23 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-35-700 Series and model code APC-35 is the product series. The final code 700 identifies the 700 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 700 mA and having a total operating voltage within 15-50 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 700 mA Operating DC voltage range 15-50 V Catalog rated power 35 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 490 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 5 units on a Type B 16 A circuit breaker, or 9 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 55-65 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Limited power source LPS is listed for this model. Class II insulation design is shown separately; these identify different safety characteristics. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-35-500

    MEAN WELL APC-35 series: constant current LED power supply - APC-35-500

    MEAN WELL APC-35-500 Constant Current LED Power Supply The MEAN WELL APC-35-500 is a single-output AC/DC constant current LED power supply providing 500 mA constant current over a 25-70 V DC operating range, with a catalog rated power of 35 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 500 mA and having a total operating voltage within 25-70 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-35 Datasheet (PDF) See PDF pages 22-23 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-35-500 Series and model code APC-35 is the product series. The final code 500 identifies the 500 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 500 mA and having a total operating voltage within 25-70 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 500 mA Operating DC voltage range 25-70 V Catalog rated power 35 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 490 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 5 units on a Type B 16 A circuit breaker, or 9 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 77-91 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals EAC TP TC 004, BS EN/EN 62368-1. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-35-350

    MEAN WELL APC-35 series: constant current LED power supply - APC-35-350

    MEAN WELL APC-35-350 Constant Current LED Power Supply The MEAN WELL APC-35-350 is a single-output AC/DC constant current LED power supply providing 350 mA constant current over a 28-100 V DC operating range, with a catalog rated power of 35 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 350 mA and having a total operating voltage within 28-100 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-35 Datasheet (PDF) See PDF pages 22-23 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-35-350 Series and model code APC-35 is the product series. The final code 350 identifies the 350 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 350 mA and having a total operating voltage within 28-100 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 350 mA Operating DC voltage range 28-100 V Catalog rated power 35 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 490 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 5 units on a Type B 16 A circuit breaker, or 9 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 110-130 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals EAC TP TC 004, BS EN/EN 62368-1. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-25-1050

    MEAN WELL APC-25 series: constant current LED power supply - APC-25-1050

    MEAN WELL APC-25-1050 Constant Current LED Power Supply The MEAN WELL APC-25-1050 is a single-output AC/DC constant current LED power supply providing 1050 mA constant current over a 9-24 V DC operating range, with a catalog rated power of 25.2 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 1050 mA and having a total operating voltage within 9-24 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-25 Datasheet (PDF) See PDF pages 20-21 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-25-1050 Series and model code APC-25 is the product series. The final code 1050 identifies the 1050 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 1050 mA and having a total operating voltage within 9-24 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 1050 mA Operating DC voltage range 9-24 V Catalog rated power 25.2 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 27-35 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Limited power source LPS is listed for this model. Class II insulation design is shown separately; these identify different safety characteristics. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-25-700

    MEAN WELL APC-25 series: constant current LED power supply - APC-25-700

    MEAN WELL APC-25-700 Constant Current LED Power Supply The MEAN WELL APC-25-700 is a single-output AC/DC constant current LED power supply providing 700 mA constant current over a 11-36 V DC operating range, with a catalog rated power of 25.2 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 700 mA and having a total operating voltage within 11-36 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-25 Datasheet (PDF) See PDF pages 20-21 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-25-700 Series and model code APC-25 is the product series. The final code 700 identifies the 700 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 700 mA and having a total operating voltage within 11-36 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 700 mA Operating DC voltage range 11-36 V Catalog rated power 25.2 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 41-49 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Limited power source LPS is listed for this model. Class II insulation design is shown separately; these identify different safety characteristics. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-25-350

    MEAN WELL APC-25 series: constant current LED power supply - APC-25-350

    MEAN WELL APC-25-350 Constant Current LED Power Supply The MEAN WELL APC-25-350 is a single-output AC/DC constant current LED power supply providing 350 mA constant current over a 25-70 V DC operating range, with a catalog rated power of 24.5 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 350 mA and having a total operating voltage within 25-70 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-25 Datasheet (PDF) See PDF pages 20-21 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-25-350 Series and model code APC-25 is the product series. The final code 350 identifies the 350 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 350 mA and having a total operating voltage within 25-70 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 350 mA Operating DC voltage range 25-70 V Catalog rated power 24.5 W. Current accuracy ±8.0%. Current ripple 5.0%, as listed in the model specification. This current-ripple figure is not a voltage-ripple rating or a guarantee of a particular visible-flicker metric. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 76-94 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals EAC TP TC 004, BS EN/EN 62368-1. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-16-700

    MEAN WELL APC-16 series: constant current LED power supply - APC-16-700

    MEAN WELL APC-16-700 Constant Current LED Power Supply The MEAN WELL APC-16-700 is a single-output AC/DC constant current LED power supply providing 700 mA constant current over a 9-24 V DC operating range, with a catalog rated power of 16.8 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 700 mA and having a total operating voltage within 9-24 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-16 Datasheet (PDF) See PDF pages 18-19 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-16-700 Series and model code APC-16 is the product series. The final code 700 identifies the 700 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 700 mA and having a total operating voltage within 9-24 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 700 mA Operating DC voltage range 9-24 V Catalog rated power 16.8 W. Current accuracy ±8.0%. Voltage tolerance ±5.0%; the catalog note includes setup tolerance. This is separate from the ±8.0% output-current accuracy. Setup and rise time 3000 ms setup / 200 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.3 A at 230 VAC; 0.5 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 210 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 13 units on a Type B 16 A circuit breaker, or 23 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 27.6-33.5 V; output shutoff with zener-diode clamping. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 77 x 40 x 29 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 90 mm overall length across mounting tabs and 82.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 100 g per unit (0.1 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-16-350

    MEAN WELL APC-16 series: constant current LED power supply - APC-16-350

    MEAN WELL APC-16-350 Constant Current LED Power Supply The MEAN WELL APC-16-350 is a single-output AC/DC constant current LED power supply providing 350 mA constant current over a 12-48 V DC operating range, with a catalog rated power of 16.8 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 350 mA and having a total operating voltage within 12-48 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-16 Datasheet (PDF) See PDF pages 18-19 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-16-350 Series and model code APC-16 is the product series. The final code 350 identifies the 350 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 350 mA and having a total operating voltage within 12-48 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 350 mA Operating DC voltage range 12-48 V Catalog rated power 16.8 W. Current accuracy ±8.0%. Voltage tolerance ±5.0%; the catalog note includes setup tolerance. This is separate from the ±8.0% output-current accuracy. Setup and rise time 3000 ms setup / 200 ms rise at both 230 VAC and 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.3 A at 230 VAC; 0.5 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 210 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 13 units on a Type B 16 A circuit breaker, or 23 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 50.4-60 V; output shutoff with zener-diode clamping. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 77 x 40 x 29 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 90 mm overall length across mounting tabs and 82.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 100 g per unit (0.1 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-12-350

    MEAN WELL APC-12 series: constant current LED power supply - APC-12-350

    MEAN WELL APC-12-350 Constant Current LED Power Supply The MEAN WELL APC-12-350 is a single-output AC/DC constant current LED power supply providing 350 mA constant current over a 9-36 V DC operating range, with a catalog rated power of 12.6 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 350 mA and having a total operating voltage within 9-36 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-12 Datasheet (PDF) See PDF pages 15-16 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-12-350 Series and model code APC-12 is the product series. The final code 350 identifies the 350 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 350 mA and having a total operating voltage within 9-36 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 350 mA Operating DC voltage range 9-36 V Catalog rated power 12.6 W. Current accuracy ±8.0%. Voltage tolerance ±5.0%; the catalog note includes setup tolerance. This is separate from the ±8.0% output-current accuracy. Setup and rise time 3000 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC; 15 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.2 A at 230 VAC; 0.35 A at 115 VAC Efficiency, typical 82% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 150 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 17 units on a Type B 16 A circuit breaker, or 29 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overvoltage protection 39.6-46.8 V; output shutoff with zener-diode clamping. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 77 x 40 x 29 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 90 mm overall length across mounting tabs and 82.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 80 g per unit (0.08 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-8-700

    MEAN WELL APC-8 series: constant current LED power supply - APC-8-700

    MEAN WELL APC-8-700 Constant Current LED Power Supply The MEAN WELL APC-8-700 is a single-output AC/DC constant current LED power supply providing 700 mA constant current over a 6-11 V DC operating range, with a catalog rated power of 7.7 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 700 mA and having a total operating voltage within 6-11 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-8 Datasheet (PDF) See PDF pages 13-14 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-8-700 Series and model code APC-8 is the product series. The final code 700 identifies the 700 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 700 mA and having a total operating voltage within 6-11 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 700 mA Operating DC voltage range 6-11 V Catalog rated power 7.7 W. Current accuracy ±8.0%. No-load output voltage 17 V; this is not the normal constant-current operating voltage. Constant-current operating region The catalog describes constant-current operation within 50-100% of rated output voltage. Use the model-specific voltage range above and reconfirm special electrical requirements for the intended LED system. Setup and rise time 500 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.15 A at 230 VAC; 0.3 A at 115 VAC Efficiency, typical 80% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 120 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. No-load input power Less than 0.5 W. Protection and fault behavior Parameter Details Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Protection scope The APC-8 specification lists short-circuit protection; it does not specify overvoltage protection. Do not rely on an overvoltage-protection function for this model. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -15 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 45°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. The series description specifies 94V-0 flame-retardant plastic. Dimensions, leads and installation Parameter Details Body dimensions 60 x 30 x 23.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 73.1 mm overall length across mounting tabs and 65.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 50 g per unit (0.05 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-8-500

    MEAN WELL APC-8 series: constant current LED power supply - APC-8-500

    MEAN WELL APC-8-500 Constant Current LED Power Supply The MEAN WELL APC-8-500 is a single-output AC/DC constant current LED power supply providing 500 mA constant current over a 8-16 V DC operating range, with a catalog rated power of 8 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 500 mA and having a total operating voltage within 8-16 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-8 Datasheet (PDF) See PDF pages 13-14 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-8-500 Series and model code APC-8 is the product series. The final code 500 identifies the 500 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 500 mA and having a total operating voltage within 8-16 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 500 mA Operating DC voltage range 8-16 V Catalog rated power 8 W. Current accuracy ±8.0%. No-load output voltage 24 V; this is not the normal constant-current operating voltage. Constant-current operating region The catalog describes constant-current operation within 50-100% of rated output voltage. Use the model-specific voltage range above and reconfirm special electrical requirements for the intended LED system. Setup and rise time 500 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.15 A at 230 VAC; 0.3 A at 115 VAC Efficiency, typical 81% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 120 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. No-load input power Less than 0.5 W. Protection and fault behavior Parameter Details Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Protection scope The APC-8 specification lists short-circuit protection; it does not specify overvoltage protection. Do not rely on an overvoltage-protection function for this model. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -15 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 45°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. The series description specifies 94V-0 flame-retardant plastic. Dimensions, leads and installation Parameter Details Body dimensions 60 x 30 x 23.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 73.1 mm overall length across mounting tabs and 65.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 50 g per unit (0.05 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-8-350

    MEAN WELL APC-8 series: constant current LED power supply - APC-8-350

    MEAN WELL APC-8-350 Constant Current LED Power Supply The MEAN WELL APC-8-350 is a single-output AC/DC constant current LED power supply providing 350 mA constant current over a 11-23 V DC operating range, with a catalog rated power of 8.05 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 350 mA and having a total operating voltage within 11-23 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-8 Datasheet (PDF) See PDF pages 13-14 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-8-350 Series and model code APC-8 is the product series. The final code 350 identifies the 350 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 350 mA and having a total operating voltage within 11-23 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 350 mA Operating DC voltage range 11-23 V Catalog rated power 8.05 W. Current accuracy ±8.0%. No-load output voltage 29 V; this is not the normal constant-current operating voltage. Constant-current operating region The catalog describes constant-current operation within 50-100% of rated output voltage. Use the model-specific voltage range above and reconfirm special electrical requirements for the intended LED system. Setup and rise time 500 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.15 A at 230 VAC; 0.3 A at 115 VAC Efficiency, typical 81.5% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 120 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. No-load input power Less than 0.5 W. Protection and fault behavior Parameter Details Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Protection scope The APC-8 specification lists short-circuit protection; it does not specify overvoltage protection. Do not rely on an overvoltage-protection function for this model. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -15 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 45°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. The series description specifies 94V-0 flame-retardant plastic. Dimensions, leads and installation Parameter Details Body dimensions 60 x 30 x 23.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 73.1 mm overall length across mounting tabs and 65.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 50 g per unit (0.05 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APC-8-250

    MEAN WELL APC-8 series: constant current LED power supply - APC-8-250

    MEAN WELL APC-8-250 Constant Current LED Power Supply The MEAN WELL APC-8-250 is a single-output AC/DC constant current LED power supply providing 250 mA constant current over a 16-32 V DC operating range, with a catalog rated power of 8 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Select an LED load requiring 250 mA and having a total operating voltage within 16-32 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Download MEAN WELL APC-8 Datasheet (PDF) See PDF pages 13-14 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APC-8-250 Series and model code APC-8 is the product series. The final code 250 identifies the 250 mA output current. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant current. Select an LED load requiring 250 mA and having a total operating voltage within 16-32 V DC. The supply regulates current; do not select it as a fixed-voltage supply. Keep within the stated operating-voltage, power and derating limits. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Rated output current 250 mA Operating DC voltage range 16-32 V Catalog rated power 8 W. Current accuracy ±8.0%. No-load output voltage 38 V; this is not the normal constant-current operating voltage. Constant-current operating region The catalog describes constant-current operation within 50-100% of rated output voltage. Use the model-specific voltage range above and reconfirm special electrical requirements for the intended LED system. Setup and rise time 500 ms setup / 180 ms rise at 230 VAC; 3000 ms setup / 150 ms rise at 115 VAC, at full load. Hold-up time, typical 20 ms at 230 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.15 A at 230 VAC; 0.3 A at 115 VAC Efficiency, typical 82.5% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 70 A at 230 VAC; pulse width 120 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. No-load input power Less than 0.5 W. Protection and fault behavior Parameter Details Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Protection scope The APC-8 specification lists short-circuit protection; it does not specify overvoltage protection. Do not rely on an overvoltage-protection function for this model. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -15 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +45°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.2%/°C over 0 to 45°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. The series description specifies 94V-0 flame-retardant plastic. Dimensions, leads and installation Parameter Details Body dimensions 60 x 30 x 23.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline The drawing shows 73.1 mm overall length across mounting tabs and 65.5 mm longitudinal mounting-center spacing. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 20 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity When using DC input, connect the brown L lead to the positive side and the blue N lead to the negative side. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-08, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Insulation classification Class II insulation design with no FG connection. Withstand voltage Input-to-output: 3.75 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 50 g per unit (0.05 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.

  • APV-35-36

    MEAN WELL APV-35 series: constant voltage LED power supply - APV-35-36

    MEAN WELL APV-35-36 Constant Voltage LED Power Supply The MEAN WELL APV-35-36 is a single-output AC/DC constant voltage LED power supply providing 36 V DC, 1 A rated output, with a catalog rated power of 36 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 36 V constant-voltage operation and keep total current within 0-1 A and power within 36 W, with input and temperature derating applied. Download MEAN WELL APV-35 Datasheet (PDF) See PDF pages 10-11 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-35-36 Series and model code APV-35 is the product series. The final code 36 identifies the 36 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 36 V constant-voltage operation and keep total current within 0-1 A and power within 36 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 36 V Rated output current 1 A Current range 0-1 A Rated output power 36 W Ripple and noise, maximum 180 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 85% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 440 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 6 units on a Type B 16 A circuit breaker, or 10 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection 110-160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 41.4-48.6 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS/CCC logos. Check the actual unit markings for the required market.

  • APV-35-24

    MEAN WELL APV-35 series: constant voltage LED power supply - APV-35-24

    MEAN WELL APV-35-24 Constant Voltage LED Power Supply The MEAN WELL APV-35-24 is a single-output AC/DC constant voltage LED power supply providing 24 V DC, 1.5 A rated output, with a catalog rated power of 36 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 24 V constant-voltage operation and keep total current within 0-1.5 A and power within 36 W, with input and temperature derating applied. Download MEAN WELL APV-35 Datasheet (PDF) See PDF pages 10-11 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-35-24 Series and model code APV-35 is the product series. The final code 24 identifies the 24 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 24 V constant-voltage operation and keep total current within 0-1.5 A and power within 36 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 24 V Rated output current 1.5 A Current range 0-1.5 A Rated output power 36 W Ripple and noise, maximum 180 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 440 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 6 units on a Type B 16 A circuit breaker, or 10 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection 110-160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 27-32.4 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS/CCC logos. Check the actual unit markings for the required market.

  • APV-35-15

    MEAN WELL APV-35 series: constant voltage LED power supply - APV-35-15

    MEAN WELL APV-35-15 Constant Voltage LED Power Supply The MEAN WELL APV-35-15 is a single-output AC/DC constant voltage LED power supply providing 15 V DC, 2.4 A rated output, with a catalog rated power of 36 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 15 V constant-voltage operation and keep total current within 0-2.4 A and power within 36 W, with input and temperature derating applied. Download MEAN WELL APV-35 Datasheet (PDF) See PDF pages 10-11 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-35-15 Series and model code APV-35 is the product series. The final code 15 identifies the 15 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 15 V constant-voltage operation and keep total current within 0-2.4 A and power within 36 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 15 V Rated output current 2.4 A Current range 0-2.4 A Rated output power 36 W Ripple and noise, maximum 150 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 440 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 6 units on a Type B 16 A circuit breaker, or 10 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection 110-160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 17.25-21 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS/CCC logos. Check the actual unit markings for the required market.

  • APV-35-12

    MEAN WELL APV-35 series: constant voltage LED power supply - APV-35-12

    MEAN WELL APV-35-12 Constant Voltage LED Power Supply The MEAN WELL APV-35-12 is a single-output AC/DC constant voltage LED power supply providing 12 V DC, 3 A rated output, with a catalog rated power of 36 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 12 V constant-voltage operation and keep total current within 0-3 A and power within 36 W, with input and temperature derating applied. Download MEAN WELL APV-35 Datasheet (PDF) See PDF pages 10-11 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-35-12 Series and model code APV-35 is the product series. The final code 12 identifies the 12 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 12 V constant-voltage operation and keep total current within 0-3 A and power within 36 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 12 V Rated output current 3 A Current range 0-3 A Rated output power 36 W Ripple and noise, maximum 150 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 83% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 440 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 6 units on a Type B 16 A circuit breaker, or 10 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection 110-160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 13.8-16.2 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS/CCC logos. Check the actual unit markings for the required market.

  • APV-35-5

    MEAN WELL APV-35 series: constant voltage LED power supply - APV-35-5

    MEAN WELL APV-35-5 Constant Voltage LED Power Supply The MEAN WELL APV-35-5 is a single-output AC/DC constant voltage LED power supply providing 5 V DC, 5 A rated output, with a catalog rated power of 25 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 5 V constant-voltage operation and keep total current within 0-5 A and power within 25 W, with input and temperature derating applied. Download MEAN WELL APV-35 Datasheet (PDF) See PDF pages 10-11 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-35-5 Series and model code APV-35 is the product series. The final code 5 identifies the 5 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 5 V constant-voltage operation and keep total current within 0-5 A and power within 25 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 5 V Rated output current 5 A Current range 0-5 A Rated output power 25 W Ripple and noise, maximum 120 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 40 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.5 A at 230 VAC; 0.75 A at 115 VAC Efficiency, typical 76.5% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 440 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 6 units on a Type B 16 A circuit breaker, or 10 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection 110-160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 5.75-6.95 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 180 g per unit (0.18 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test. Regional markings The datasheet notes that units sourced from the Americas may not carry ENEC/BIS/CCC logos. Check the actual unit markings for the required market.

  • APV-25-36

    MEAN WELL APV-25 series: constant voltage LED power supply - APV-25-36

    MEAN WELL APV-25-36 Constant Voltage LED Power Supply The MEAN WELL APV-25-36 is a single-output AC/DC constant voltage LED power supply providing 36 V DC, 0.7 A rated output, with a catalog rated power of 25.2 W. It accepts 90-264 VAC or 127-370 VDC and uses a fully isolated IP42 plastic enclosure cooled by free-air convection. Use a load designed for 36 V constant-voltage operation and keep total current within 0-0.7 A and power within 25.2 W, with input and temperature derating applied. Download MEAN WELL APV-25 Datasheet (PDF) See PDF pages 8-9 for this model column, its connection drawing and derating curves. Download MEAN WELL LED Installation Manual (PDF) Model and application Parameter Details Full model APV-25-36 Series and model code APV-25 is the product series. The final code 36 identifies the 36 V output. The series wattage designation is not a substitute for this model's actual rated output power. Operating mode Constant voltage. Use a load designed for 36 V constant-voltage operation and keep total current within 0-0.7 A and power within 25.2 W, with input and temperature derating applied. Intended application LED-related fixtures or appliances, such as decoration or advertising devices. The manufacturer states that this product is not intended for LED lighting luminaire applications in the EU and China. Application qualification Use the supply as a component in the final equipment. The equipment manufacturer must assess the complete installation and re-qualify EMC performance with the load, wiring and enclosure. Output and dynamic performance Parameter Details Nominal DC voltage 36 V Rated output current 0.7 A Current range 0-0.7 A Rated output power 25.2 W Ripple and noise, maximum 150 mV peak-to-peak. Measured at 20 MHz bandwidth using a 12-inch twisted-pair wire terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±5.0%, including setup tolerance, line regulation and load regulation. Line / load regulation Line regulation: ±1.0%; load regulation: ±2.0%. Setup and rise time 1500 ms setup / 30 ms rise at both 230 VAC and 115 VAC, at full load. Setup time is measured at the first cold start; repeated ON/OFF operation may increase it. Hold-up time, typical 20 ms at 230 VAC; 12 ms at 115 VAC, at full load. Measurement basis Unless otherwise specified: 230 VAC input, rated load and 25°C ambient. Typical values depend on operating conditions. Input and supply planning Parameter Details Input range 90-264 VAC, 47-63 Hz; alternatively 127-370 VDC. Apply the input-voltage derating curve. AC input current 0.4 A at 230 VAC; 0.8 A at 115 VAC Efficiency, typical 84% at the catalog measurement conditions; not a guaranteed efficiency at every input and load. Cold-start inrush, typical 45 A at 230 VAC; pulse width 310 µs measured at 50% of peak current. Leakage current 0.25 mA at 240 VAC. Input-voltage derating At 60 Hz, the static-characteristic curve shows 80% load at 90 VAC, rising to 100% at 100 VAC; 100% is shown from 100 to 264 VAC. Apply the more restrictive thermal/load condition at the same time. Short-duration input withstand Withstands 300 VAC surge input for 5 seconds. This is a brief input-withstand specification, not a continuous input rating or an output peak-power allowance. 16 A circuit-breaker reference At 230 VAC the catalog lists up to 9 units on a Type B 16 A circuit breaker, or 15 units on a Type C 16 A circuit breaker. Use this reference with the actual circuit and installation requirements. Protection and fault behavior Parameter Details Short-circuit protection Short-circuit protection is listed among the model features. Overload protection Above 105% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage protection 41.4-48.6 V; output shutdown; re-power on to recover. Thermal operating limits Maintain the required ventilation and derate load as ambient temperature rises. Do not treat the upper ambient rating as a full-load rating. Environment and derating Parameter Details Working ambient temperature -30 to +70°C, subject to the derating curve. Cooling and temperature derating Free-air convection, with the horizontal orientation shown in the drawing. Full load is shown up to +40°C, then decreases linearly to 60% load at +70°C. Keep the input-voltage derating limit at the same time. Altitude derating Above 2000 m (6500 ft), reduce the allowable ambient temperature by 3.5°C per 1000 m for this fanless design. Working humidity 20-90% RH, non-condensing. Storage temperature / humidity -40 to +80°C; 10-95% RH. Temperature coefficient ±0.03%/°C over 0 to 50°C. Vibration 10-500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Enclosure Fully isolated plastic case, IP42 design. Observe the manufacturer installation instructions for the intended enclosure and environment. Dimensions, leads and installation Parameter Details Body dimensions 84 x 57 x 29.5 mm (L x W x H); drawing tolerance ±1 mm. Mounting outline Case PCD16A; two mounting features are marked Ø3.6 mm with Ø8.9 mm surrounding features. Use the mechanical drawing for the offset mounting positions. Input leads UL1569, 18 AWG; 150 ±10 mm. Brown = AC/L; blue = AC/N. Output leads UL1569, 18 AWG; 150 ±10 mm. Red = +V; black = -V. Match output polarity to the load. DC-input polarity DC input is rated 127-370 VDC. Before DC connection, obtain the manufacturer polarity instructions for this exact model; do not assume the L/N-to-positive/negative mapping from another model. Installation Class II design with no FG connection. Before installation or maintenance, disconnect the supply from the utility and prevent inadvertent reconnection. Keep proper ventilation around the unit and do not stack objects on it. When an adjacent device is a heat source, maintain 10-15 cm clearance. Keep lead-wire connections insulated and mechanically secured, and select approved cables rated for at least the unit current. Nonstandard mounting orientations or high ambient temperature require output-current derating. The installation manual limits APC/APV to equipment with a primary use other than lighting, such as copiers or overhead projectors, or to scale and display lighting; also observe the regional luminaire restriction above. Case-temperature point The mechanical drawing identifies the tc / T case measurement point. Its location dimensions are not temperature limits. Connection and mounting items This is a wired power-supply module. Select suitable connection and mounting hardware for the final equipment using the lead specifications and mechanical drawing above. Standards and catalog references Parameter Details Listed safety approvals UL 8750, CSA C22.2 No.250.0-13, EAC TP TC 004, BS EN/EN 62368-1, BIS IS 15885. Select the actual supplied regional version and required markings for the installation. Power-unit classification Class II insulation design; Class 2 power unit; LPS, as listed in the series features. Class II and Class 2 are different classifications. Withstand voltage Input-to-output: 3 kVAC. Insulation resistance Input-to-output: greater than 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions Compliance listed to BS EN/EN 55032, BS EN/EN 61000-3-2 Class A, BS EN/EN 61000-3-3 and EAC TP TC 020. EMC immunity Compliance listed to BS EN/EN 55035 and BS EN/EN 61000-4-2, -3, -4, -5, -6, -8 and -11; light-industry level with 2 kV surge. The completed installation still requires assessment. Catalog mass reference 130 g per unit (0.13 kg), from the PACKING field. This is the catalog packing reference per unit, not a measured net weight or a complete shipping-package weight. Manufacturer catalog statement The manufacturer datasheet lists a two-year warranty and a 100% full-load burn-in test.


You have seen 24 out of 37 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa