MSP:Single Output Medical Grade Switching Power Supply

44 products

MEAN WELL MSP Series Premium Medical Power Supply

Complete Portfolio: 100W to 1600W | MOOP/MOPP Safety | Ultra-Low Leakage Current | 5-Year Warranty

  • Medical Overview
  • Low-Mid Power (100W~300W)
  • High Power (450W~1600W)
  • Smart Control Features
  • Safety & Dimensions

Engineered for Critical Medical Applications

The MEAN WELL MSP Series represents the highest standard in medical-grade enclosed power supplies. Ranging from 100W to 1600W, this family is rigorously tested and certified to international medical safety standards, ensuring maximum patient and operator protection in clinical environments.

Core Medical Advantages

  • Strict Safety Isolation: Achieves basic medical safety levels (MOOP), with the flagship MSP-1600 achieving 2xMOPP (Means of Patient Protection) primary-to-secondary isolation.
  • Ultra-Low Leakage Current: Engineered for safety with earth leakage current typically below 300μA (or <500μA on highest power models) and touch current below 100μA.
  • High Reliability Design: Built with 105°C long-life electrolytic capacitors, high efficiency topologies (up to 92%), and backed by a comprehensive 5-year warranty.
  • Surge Immunity: Capable of withstanding a 300VAC input surge for 5 seconds without damage.

MSP-100, MSP-200, & MSP-300 Specifications

The lower wattage segments are highly compact (1U low profile, 38mm~41mm height) and designed for quieter operation. The 100W and 200W models rely completely on free air convection cooling.

Model Series Max Power Available DC Voltages Max Efficiency Cooling Method
MSP-100 100W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 90% Free Air Convection
MSP-200 200W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% Free Air Convection
MSP-300 300W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% Built-in Fan (Speed Controlled)
Energy Saving: All models in this tier feature exceptionally low no-load power consumption (< 0.5W), making them compliant with eco-design requirements.

MSP-450, MSP-600, MSP-1000 & MSP-1600 Specifications

For demanding medical imaging, lab automation, and high-power diagnostic equipment, the mid-to-high wattage MSP series delivers robust power with active thermal management and active PFC.

Model Series Max Power Available DC Voltages Max Efficiency Active PFC
MSP-450 450W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89.5% PF > 0.95
MSP-600 600W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% PF > 0.93
MSP-1000 1000W 12V, 15V, 24V, 48V Up to 94% PF > 0.95
MSP-1600 1600W 12V, 24V, 36V, 48V Up to 92% PF > 0.97

Advanced Controls & System Integration

Starting from the MSP-200 series and up, MEAN WELL has integrated extensive auxiliary functions to serve modern, digitized medical equipment.

Auxiliary & Diagnostic Signals

  • Remote ON/OFF: Standard on all models, allowing the main power to be toggled electronically via a remote signal.
  • 5V Standby Output: Models from 200W~1000W include an independent 5V@0.3A (or 5V@0.3A~0.5A depending on model) standby circuit to keep logic controllers awake. (Note: MSP-1600 features 12V@0.8A Aux).
  • DC OK Signal: Provides a TTL or relay contact signal to notify the system motherboard that the power output is stable.
  • Remote Sense: Compensates for voltage drops across the output wiring (compensates up to 0.5V).

Flagship Capabilities (MSP-1000 / MSP-1600)

  • Current Sharing (Paralleling): The MSP-600 (up to 2400W) and MSP-1000 (up to 4000W) support active current sharing to scale power seamlessly.
  • Programmable Voltage (PV): The MSP-1600 allows output voltage to be trimmed dynamically from 15% to 115% via an external signal.
  • Digital Communication: The MSP-1600 is equipped with built-in CANBus (PMBus optional) for deep system diagnostics, control, and remote monitoring.

Medical Certifications & Physical Dimensions

Medical Standards Compliance

  • Global Safety: Approved to IEC 60601-1, ANSI/AAMI ES60601-1, TUV EN60601-1.
  • Isolation Level: General series operates at MOOP (Means of Operator Protection). The flagship MSP-1600 operates at the strictest 2xMOPP (Primary to Secondary).
  • EMC Immunity: Meets rigorous medical EMC standards (EN55011 Class B).

Dimensions (L * W * H)

Model Length Width Height (Profile)
MSP-100 159 mm 97 mm 38 mm (1U)
MSP-200 199 mm 98 mm 38 mm (1U)
MSP-300 199 mm 105 mm 41 mm
MSP-450 218 mm 105 mm 41 mm
MSP-600 218 mm 105 mm 63.5 mm
MSP-1000 218 mm 105 mm 63.5 mm
MSP-1600 310 mm 85 mm 41 mm
  • MSP-300-12

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-12

    MEAN WELL MSP-300-12 is a single-output enclosed medical-type AC/DC power supply rated 12 VDC, 27 A and 324 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-12: MSP-300 single-output enclosed medical-type AC/DC power supply; -12 identifies the nominal 12 VDC output. Catalogue revision 2026-02-09. Rated output 12 VDC; 27 A; 324 W. Current range: 0–27 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 10.2–13.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 88%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 14.4–16.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-7.5

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-7.5

    MEAN WELL MSP-300-7.5 is a single-output enclosed medical-type AC/DC power supply rated 7.5 VDC, 40 A and 300 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-7.5: MSP-300 single-output enclosed medical-type AC/DC power supply; -7.5 identifies the nominal 7.5 VDC output. Catalogue revision 2026-02-09. Rated output 7.5 VDC; 40 A; 300 W. Current range: 0–40 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 6.8–9 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 100 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 86%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 9.4–10.9 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-5

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-5

    MEAN WELL MSP-300-5 is a single-output enclosed medical-type AC/DC power supply rated 5 VDC, 60 A and 300 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-5: MSP-300 single-output enclosed medical-type AC/DC power supply; -5 identifies the nominal 5 VDC output. Catalogue revision 2026-02-09. Rated output 5 VDC; 60 A; 300 W. Current range: 0–60 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 4.3–5.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 90 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 82%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 6–7 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-3.3

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-3.3

    MEAN WELL MSP-300-3.3 is a single-output enclosed medical-type AC/DC power supply rated 3.3 VDC, 60 A and 198 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-3.3: MSP-300 single-output enclosed medical-type AC/DC power supply; -3.3 identifies the nominal 3.3 VDC output. Catalogue revision 2026-02-09. Rated output 3.3 VDC; 60 A; 198 W. Current range: 0–60 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 2.8–3.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 80 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.5%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 80%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 3.96–4.62 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-200-48

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-48

    MEAN WELL MSP-200-48 is a single-output medical-type power supply rated at 48 V DC, 4.3 A and 206.4 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-48; MSP-200 revision 2024-10-30. The final code identifies the nominal 48 V output. Rated DC output 48 V / 4.3 A / 206.4 W. Current range at nominal voltage: 0–4.3 A. Voltage adjustment 40.8–55.2 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 250 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 89%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 206.4 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 57.6–67.2 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-36

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-36

    MEAN WELL MSP-200-36 is a single-output medical-type power supply rated at 36 V DC, 5.7 A and 205.2 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-36; MSP-200 revision 2024-10-30. The final code identifies the nominal 36 V output. Rated DC output 36 V / 5.7 A / 205.2 W. Current range at nominal voltage: 0–5.7 A. Voltage adjustment 28.8–39.6 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 250 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 89%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 205.2 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 41.4–48.6 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-24

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-24

    MEAN WELL MSP-200-24 is a single-output medical-type power supply rated at 24 V DC, 8.4 A and 201.6 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-24; MSP-200 revision 2024-10-30. The final code identifies the nominal 24 V output. Rated DC output 24 V / 8.4 A / 201.6 W. Current range at nominal voltage: 0–8.4 A. Voltage adjustment 21.6–28.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 88%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 201.6 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 30–34.8 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-15

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-15

    MEAN WELL MSP-200-15 is a single-output medical-type power supply rated at 15 V DC, 13.4 A and 201 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-15; MSP-200 revision 2024-10-30. The final code identifies the nominal 15 V output. Rated DC output 15 V / 13.4 A / 201 W. Current range at nominal voltage: 0–13.4 A. Voltage adjustment 13.5–18 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.5%, respectively. Typical efficiency 88%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 201 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 18.8–21.8 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-12

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-12

    MEAN WELL MSP-200-12 is a single-output medical-type power supply rated at 12 V DC, 16.7 A and 200.4 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-12; MSP-200 revision 2024-10-30. The final code identifies the nominal 12 V output. Rated DC output 12 V / 16.7 A / 200.4 W. Current range at nominal voltage: 0–16.7 A. Voltage adjustment 10.2–13.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.5%, respectively. Typical efficiency 88%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 200.4 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 14.4–16.8 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-7.5

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-7.5

    MEAN WELL MSP-200-7.5 is a single-output medical-type power supply rated at 7.5 V DC, 26.7 A and 200.3 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-7.5; MSP-200 revision 2024-10-30. The final code identifies the nominal 7.5 V output. Rated DC output 7.5 V / 26.7 A / 200.3 W. Current range at nominal voltage: 0–26.7 A. Voltage adjustment 6.8–9 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 100 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%, respectively. Typical efficiency 86%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 200.3 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 9.4–10.9 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-5

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-5

    MEAN WELL MSP-200-5 is a single-output medical-type power supply rated at 5 V DC, 35 A and 175 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-5; MSP-200 revision 2024-10-30. The final code identifies the nominal 5 V output. Rated DC output 5 V / 35 A / 175 W. Current range at nominal voltage: 0–35 A. Voltage adjustment 4.3–5.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 90 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%, respectively. Typical efficiency 84%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 175 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 6–7 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-200-3.3

    MEAN WELL MSP-200 series: Single-Output Medical Power Supply with PFC - MSP-200-3.3

    MEAN WELL MSP-200-3.3 is a single-output medical-type power supply rated at 3.3 V DC, 40 A and 132 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. This MSP-200 model also provides remote sense and a separate 5 V standby output. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-200 Datasheet (PDF) The MSP-200 section is on PDF pages 3, 4, 5. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-200-3.3; MSP-200 revision 2024-10-30. The final code identifies the nominal 3.3 V output. Rated DC output 3.3 V / 40 A / 132 W. Current range at nominal voltage: 0–40 A. Voltage adjustment 2.8–3.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 80 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5%, respectively. Typical efficiency 80%, under the default 230 VAC, rated-load and 25°C test conditions. The 200 series designation is not a promise of that wattage at every output voltage. Use this model’s 132 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.99 at 115 VAC, at full load. Typical AC input current 2.2 A at 115 VAC; 1.1 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 70 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 1000 / 50 ms; 115 VAC: 2500 / 50 ms. Typical hold-up at full load 16 ms at 230 VAC; 16 ms at 115 VAC. No-load input power <0.5 W with RC+ and RC− shorted so that the main output is OFF, as specified in note 6. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting, with automatic recovery after the fault is removed. Over-voltage 3.96–4.62 V; output shutdown, with re-powering required to recover. Over-temperature Output shutdown with automatic recovery after temperature decreases. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic CN100 pin 1 RC+ and pin 2 RC−: 4–10 VDC or open = ON; 0–0.8 VDC or short = OFF. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC+; 2 RC−; 3 AUX; 4 AUXG; 5 +S; 6 −S. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Remote Sense and Auxiliary Output Remote sense CN100 pin 5 +S connects to the positive load terminal; pin 6 −S connects to the negative load terminal. Twist +S and −S together to reduce noise pickup. Maximum line-drop compensation: 0.5 V. Standby specification 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum. The function table states 4.75–5.25 V. Auxiliary connections Pin 3 AUX is referenced to pin 4 AUXG. AUXG is isolated from the main +V and −V output terminals. Auxiliary behavior The auxiliary output includes built-in ORing diodes and is not controlled by the main-output remote ON/OFF function. Connect sensing leads at the load as shown on PDF page 5. The auxiliary ORing statement does not establish a main-output active-current-sharing function for MSP-200. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +70°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 40% at +70°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The MSP-200 isolation-level row does not assign a separate secondary-to-earth MOOP level. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. Mechanical Installation, Connectors and Weight Body dimensions / case 199 × 98 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 902E. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 13 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 4-M3; 3-M3. No thread-depth number is given beside these MSP-200 callouts; select mounting screws from the applicable drawing and installation requirements. Adjustment / indicator SVR1 and the LED location are shown in the mechanical drawing. Control connector as printed CN100: HRS DF11-6DP-2DS or equivalent. Mating housing: HRS DF11-6DS or equivalent. Contact: HRS DF11-**SC or equivalent. Connector selection Mating housing is a printed abbreviated code; the contact has a literal ** placeholder. Final order codes require contact/wire and connector selection. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.77 kg per unit = 770 g. The complete PACKING entry is 0.77 kg; 18 pcs / 14.9 kg / 0.87 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 4 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-200 pages. Reliability and Manufacturer Information MTBF reference 1609.5 K hours minimum under Telcordia SR-332 (Bellcore); 186.2 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Switching block diagram PWM frequency: 70 kHz, as marked on the MSP-200 block diagram.

    $203.06

  • MSP-100-48

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-48

    MEAN WELL MSP-100-48 is a single-output medical-type power supply rated at 48 V DC, 2.2 A and 105.6 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-48; MSP-100 revision 2025-03-17. The final code identifies the nominal 48 V output. Rated DC output 48 V / 2.2 A / 105.6 W. Current range at nominal voltage: 0–2.2 A. Voltage adjustment 45.6–55.2 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 240 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 90%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 105.6 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 57.6–67.2 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-36

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-36

    MEAN WELL MSP-100-36 is a single-output medical-type power supply rated at 36 V DC, 2.9 A and 104.4 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-36; MSP-100 revision 2025-03-17. The final code identifies the nominal 36 V output. Rated DC output 36 V / 2.9 A / 104.4 W. Current range at nominal voltage: 0–2.9 A. Voltage adjustment 34.2–39.6 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 200 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 89%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 104.4 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 41.4–48.6 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-24

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-24

    MEAN WELL MSP-100-24 is a single-output medical-type power supply rated at 24 V DC, 4.5 A and 108 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-24; MSP-100 revision 2025-03-17. The final code identifies the nominal 24 V output. Rated DC output 24 V / 4.5 A / 108 W. Current range at nominal voltage: 0–4.5 A. Voltage adjustment 22.8–28.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5%, respectively. Typical efficiency 88.5%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 108 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 30–34.8 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-15

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-15

    MEAN WELL MSP-100-15 is a single-output medical-type power supply rated at 15 V DC, 7 A and 105 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-15; MSP-100 revision 2025-03-17. The final code identifies the nominal 15 V output. Rated DC output 15 V / 7 A / 105 W. Current range at nominal voltage: 0–7 A. Voltage adjustment 14.25–18 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.8%, respectively. Typical efficiency 88%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 105 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 18.8–21.8 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-12

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-12

    MEAN WELL MSP-100-12 is a single-output medical-type power supply rated at 12 V DC, 8.5 A and 102 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-12; MSP-100 revision 2025-03-17. The final code identifies the nominal 12 V output. Rated DC output 12 V / 8.5 A / 102 W. Current range at nominal voltage: 0–8.5 A. Voltage adjustment 11.4–13.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.8%, respectively. Typical efficiency 87.5%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 102 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 14.4–16.8 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-7.5

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-7.5

    MEAN WELL MSP-100-7.5 is a single-output medical-type power supply rated at 7.5 V DC, 13.5 A and 101.3 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-7.5; MSP-100 revision 2025-03-17. The final code identifies the nominal 7.5 V output. Rated DC output 7.5 V / 13.5 A / 101.3 W. Current range at nominal voltage: 0–13.5 A. Voltage adjustment 7.1–9 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 100 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5%, respectively. Typical efficiency 84%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 101.3 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 9.4–10.9 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-5

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-5

    MEAN WELL MSP-100-5 is a single-output medical-type power supply rated at 5 V DC, 17 A and 85 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-5; MSP-100 revision 2025-03-17. The final code identifies the nominal 5 V output. Rated DC output 5 V / 17 A / 85 W. Current range at nominal voltage: 0–17 A. Voltage adjustment 4.75–5.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 80 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance +2.5 / −3.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±2.0%, respectively. Typical efficiency 83%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 85 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 6–7 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71

  • MSP-100-3.3

    MEAN WELL MSP-100 series: Single-Output Medical Power Supply with PFC - MSP-100-3.3

    MEAN WELL MSP-100-3.3 is a single-output medical-type power supply rated at 3.3 V DC, 20 A and 66 W. The 38 mm low-profile enclosure uses free-air convection. Universal AC input, active PFC and remote ON/OFF are provided. Over-temperature protection is an optional configuration on MSP-100, not an assumed feature of every unit. Medical isolation levels and leakage test conditions are specified below; final-equipment suitability requires integration assessment. Product Datasheet Download MEAN WELL MSP-100 Datasheet (PDF) The MSP-100 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model / catalogue MSP-100-3.3; MSP-100 revision 2025-03-17. The final code identifies the nominal 3.3 V output. Rated DC output 3.3 V / 20 A / 66 W. Current range at nominal voltage: 0–20 A. Voltage adjustment 3.1–3.8 V using SVR1. Observe rated current and power when adjusting voltage. Ripple and noise 80 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance +2.5 / −3.5%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±2.0%, respectively. Typical efficiency 78%, under the default 230 VAC, rated-load and 25°C test conditions. The 100 series designation is not a promise of that wattage at every output voltage. Use this model’s 66 W rating together with its current limit and both derating curves. Input, Timing and Low-load Consumption Input / frequency 85–264 VAC or 120–370 VDC; 47–63 Hz AC. Full-range input with built-in active PFC. Typical power factor >0.95 at 230 VAC and >0.98 at 115 VAC, at full load. Typical AC input current 1.2 A at 115 VAC; 0.6 A at 230 VAC. Typical inrush current 35 A at 115 VAC; 65 A at 230 VAC. The block diagram includes active inrush-current limiting. Short-duration input withstand 300 VAC surge input for 5 seconds, as the feature list states. This does not extend the continuous 264 VAC input limit. Setup / rise at full load 230 VAC: 2500 / 100 ms; 115 VAC: 2500 / 100 ms. Typical hold-up at full load 50 ms at 230 VAC; 20 ms at 115 VAC. No-load input power <0.5 W, as stated in the MSP-100 feature list. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload Short-circuit and overload protection; threshold 105–135% of rated output power. Constant-current limiting for output voltage at 50–100% of nominal, with automatic recovery after the fault is removed. Over-voltage 3.96–4.62 V; output shutdown, with re-powering required to recover. Over-temperature Optional on MSP-100. When this protection is fitted, the specified action is output shutdown with automatic recovery after temperature decreases. Confirm the required configuration when ordering. Protection thresholds are fault-response limits, not continuous or peak-output ratings. Remote Control and Power Connections Remote ON/OFF logic Across RC+ and RC−: 0–0.8 VDC = ON; 4–10 VDC = OFF. CN100 pin 1 is RC− and pin 2 is RC+. AC / earth terminals Terminal 1: AC/L; terminal 2: AC/N; terminal 3: FG protective earth. DC output terminals Terminals 4–5: −V; terminals 6–7: +V. Use the numbered mechanical drawing for polarity. CN100 signals 1 RC−; 2 RC+. These control pins are distinct from the AC and DC power terminals. Use the remote-control logic specified for this family; it must not be inferred from another MSP series. Cooling, Derating and Environment Cooling Free-air convection; keep ventilation openings unobstructed. The specified curves are for horizontal mounting. Working temperature / thermal load −40°C to +60°C, subject to derating. The horizontal curve shows 100% load through +40°C, then falls to 50% at +60°C. Input-voltage load curve At 60 Hz, the graph rises from 80% load at 85 VAC to its full-load plateau at 100 VAC, continuing to 264 VAC. Apply this percentage to the model’s own output rating. Altitude derating For this fanless model, reduce allowable ambient temperature by 3.5°C per additional 1000 m above 2000 m. This adjustment is not an independently specified maximum operating altitude. Humidity / storage Working: 20–90% RH, non-condensing. Storage: −40°C to +85°C, 10–95% RH. Temperature coefficient ±0.04%/°C over 0–50°C. Vibration 10–500 Hz, 5G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Input and ambient derating apply together. The maximum working temperature is not a full-load guarantee. Medical Isolation, Leakage and EMC Listed medical safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004 approved, as listed in this catalogue. Isolation levels Primary to secondary: 2×MOOP; primary to earth: 1×MOOP; secondary to earth: 1×MOOP. Leakage-current limits Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Touch current is measured from primary input to DC output. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Other design references BS EN/EN60335-1 and BS EN/EN62368-1 are design references by request; they are distinct from the listed medical approvals. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. These MOOP and leakage statements describe the supply under the stated tests; they do not establish MOPP, a patient-applied-part classification, or compliance of a complete medical device. The manufacturer’s EMC tests mount the unit on a 360 × 360 mm metal plate, 1 mm thick. As this supply is a component of final equipment, reconfirm EMC compliance after integration. At input below 40 VAC, performance can degrade; the final-equipment manufacturer must verify that this abnormal-input behavior does not affect basic safety or essential performance. This note does not extend the rated 85 VAC operating range. Mechanical Installation, Connectors and Weight Body dimensions / case 159 × 97 × 38 mm (L × W × H), general tolerance ±1 mm; case drawing 901I. The 38 mm height is the low-profile / 1U feature stated by the manufacturer. Terminal projection The mechanical drawing marks a terminal projection of 10 mm maximum beyond the body; allow this additional connection clearance. Mounting-hole callouts 2-M3 L=4; 6-M3 (Both Sides) L=6. The L values are drawing thread-length labels in mm. They do not identify an included screw kit. Adjustment / indicator SVR1 and CN100 are located in the mechanical drawing. Control connector as printed CN100: JST B-XH or equivalent. Mating housing: JST XHP or equivalent. Contact: JST SXH-001T or equivalent. Connector selection Header and mating-housing names are printed prefixes; do not infer unprinted order-code suffixes. The printed mating-part references identify compatible connector families; they do not state that a mating housing, contacts or cable are supplied. Catalogue unit packing reference 0.55 kg per unit = 550 g. The complete PACKING entry is 0.55 kg; 24 pcs / 14.3 kg / 0.9 CUFT; the carton weight is not the individual unit weight. Use the full case drawing on PDF page 2 for hole positions, slots and terminal layout. No separate MEAN WELL bracket, cover or cable order code is listed on these MSP-100 pages. Reliability and Manufacturer Information MTBF reference 2272.8 K hours minimum under Telcordia SR-332 (Bellcore); 352.4 K hours minimum under MIL-HDBK-217F at 25°C. These are reliability calculations, not a guaranteed operating lifetime. Manufacturer warranty statement The catalogue lists a five-year warranty, subject to applicable manufacturer terms. Capacitor specification The MSP-100 feature list specifies 105°C long-life electrolytic capacitors.

    $123.71