PSC Series: Security Battery Charger , ADS Series: AC/DC Power Supply , AD Series: Switching Power Supply with Battery Charger , ADD Series: Dual Output Switching Power Supply with Battery Charger

67 products

MEAN WELL Security Power & Battery Backup Series

  • Series Features
  • Key Specifications
  • Series Overview
  • Selection Guide

Security Power & Backup Features

These series are engineered to support critical security and surveillance installations. They integrate power supply and battery charging functions to ensure continuous operation during grid failure.

  • UPS Function: Integrated battery charging and backup capability ensures equipment remains powered during AC power outages.
  • Dual/Single Output Options: Available in both single (AD/PSC/ADS) and dual-output (ADD) configurations to power various camera, sensor, and control systems simultaneously.
  • Compact Form Factor: Small, reliable, and cost-effective designs suitable for security enclosures and control cabinets.
  • Essential Protections: Includes battery low protection (prevents deep discharge), short circuit, and overload protection.
  • LED Status Indicators: Provides clear diagnostic feedback for AC input and DC output status.

Technical Specifications

Parameter Specification Detail
Input Voltage Universal AC Input (varies by model)
UPS Function Integrated battery charging & switching
Operating Temp. -10°C to +50°C (Refer to derating)
Protections Short circuit / Overload / Over voltage / Battery low
Compliance UL, CB, CE (Standard safety approvals)

Series Range Overview

Series Output Type Description
PSC Single Security power supply with battery charger (UPS).
AD Single Security power with built-in UPS function.
ADS Single General industrial security power.
ADD Dual Dual output security power with UPS function.
Note: The "ADD" series is particularly useful for systems where you need one rail for the control unit and a second, isolated rail for security cameras or sensors.

Selection Guide

Choose the series based on your output requirements and the need for backup battery management.

Requirement Recommended Series
Simple Backup PSC or AD
Dual Rails (e.g., Main + Sensors) ADD (Dual Output)
Basic Security Power (No UPS) ADS
Design Tips: 1. Always calculate the total power consumption (Watts) of all connected cameras and sensors. 2. Ensure the battery capacity (Ah) selected is sufficient to maintain system runtime during your required outage period. 3. Battery connection cables are usually included; ensure the battery matches the voltage specification of the unit.
  • ADD-155C

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155C

    MEAN WELL ADD-155C is a dual-output power supply with battery charger with 54 V / 5 V / 53.5 V channels and a total rated output of 149.9 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155C Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 149.9 W CH1 voltage adjustment 48–58 V CH1 function Main regulated output CH1 output voltage 54 V CH1 rated current 2.3 A CH1 current range 0–2.5 A CH1 ripple and noise maximum 240 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±5% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 53.5 V CH3 rated current 0.2 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 62.1–72.9 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 39 V ±2 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155C

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155C

    MEAN WELL ADD-155C is a dual-output power supply with battery charger with 54 V / 5 V / 53.5 V channels and a total rated output of 149.9 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155C Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 149.9 W CH1 voltage adjustment 48–58 V CH1 function Main regulated output CH1 output voltage 54 V CH1 rated current 2.3 A CH1 current range 0–2.5 A CH1 ripple and noise maximum 240 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±5% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 53.5 V CH3 rated current 0.2 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 62.1–72.9 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 39 V ±2 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155C

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155C

    MEAN WELL ADD-155C is a dual-output power supply with battery charger with 54 V / 5 V / 53.5 V channels and a total rated output of 149.9 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155C Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 149.9 W CH1 voltage adjustment 48–58 V CH1 function Main regulated output CH1 output voltage 54 V CH1 rated current 2.3 A CH1 current range 0–2.5 A CH1 ripple and noise maximum 240 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±5% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 53.5 V CH3 rated current 0.2 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 62.1–72.9 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 39 V ±2 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155B

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155B

    MEAN WELL ADD-155B is a dual-output power supply with battery charger with 27.6 V / 5 V / 27.1 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155B Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 4.5 A CH1 current range 0–5 A CH1 ripple and noise maximum 200 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 27.1 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 19.5 V (+1.5 V / −1 V) Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155B

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155B

    MEAN WELL ADD-155B is a dual-output power supply with battery charger with 27.6 V / 5 V / 27.1 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155B Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 4.5 A CH1 current range 0–5 A CH1 ripple and noise maximum 200 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 27.1 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 19.5 V (+1.5 V / −1 V) Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155B

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155B

    MEAN WELL ADD-155B is a dual-output power supply with battery charger with 27.6 V / 5 V / 27.1 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155B Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 4.5 A CH1 current range 0–5 A CH1 ripple and noise maximum 200 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 27.1 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 81% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 19.5 V (+1.5 V / −1 V) Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155A

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155A

    MEAN WELL ADD-155A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.3 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155A Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 9.5 A CH1 current range 0–10.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±2% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 13.3 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 78% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 10 V ±0.8 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific input derating plot at 60 Hz shows 80% load at 88 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply input and temperature limits together. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155A

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155A

    MEAN WELL ADD-155A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.3 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155A Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 9.5 A CH1 current range 0–10.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±2% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 13.3 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 78% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 10 V ±0.8 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific input derating plot at 60 Hz shows 80% load at 88 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply input and temperature limits together. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-155A

    MEAN WELL ADD-155 series: Dual-Output Power Supply with Battery Charger - ADD-155A

    MEAN WELL ADD-155A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.3 V channels and a total rated output of 152.75 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-155 Datasheet (PDF) The ADD-155 section is on PDF pages 25, 26. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-155A Series ADD-155 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 152.75 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 9.5 A CH1 current range 0–10.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±2% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–3 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±2% CH3 function Battery-charging output CH3 output voltage 13.3 V CH3 rated current 0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 78% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 10 V ±0.8 V Battery-polarity protection Provided CH3 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 +5V Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on the +5 V output Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific input derating plot at 60 Hz shows 80% load at 88 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply input and temperature limits together. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1744.5K hours minimum MTBF, MIL-HDBK-217F 221.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 1000 g Catalogue packing 1 kg; 16 pcs / 16 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $174.47

  • ADD-55B

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55B

    MEAN WELL ADD-55B is a dual-output power supply with battery charger with 27.6 V / 5 V / 26.5 V channels and a total rated output of 55.12 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55B Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 55.12 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 1.3 A CH1 current range 0–2 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 150 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 26.5 V CH3 rated current 0.16 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 74% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 28.98–37.26 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • ADD-55B

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55B

    MEAN WELL ADD-55B is a dual-output power supply with battery charger with 27.6 V / 5 V / 26.5 V channels and a total rated output of 55.12 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55B Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 55.12 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 1.3 A CH1 current range 0–2 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 150 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 26.5 V CH3 rated current 0.16 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 74% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 28.98–37.26 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • ADD-55B

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55B

    MEAN WELL ADD-55B is a dual-output power supply with battery charger with 27.6 V / 5 V / 26.5 V channels and a total rated output of 55.12 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55B Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 55.12 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 1.3 A CH1 current range 0–2 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 150 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 26.5 V CH3 rated current 0.16 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 74% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 28.98–37.26 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • ADD-55A

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55A

    MEAN WELL ADD-55A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.4 V channels and a total rated output of 52.58 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55A Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 52.58 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 2.5 A CH1 current range 0–3.5 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 13.4 V CH3 rated current 0.23 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 71% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 14.49–18.63 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific static-characteristics graph plots output voltage and ripple against 60 Hz AC input. It is not an additional load-versus-input curve or permission to operate outside the 88–264 VAC input range. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • ADD-55A

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55A

    MEAN WELL ADD-55A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.4 V channels and a total rated output of 52.58 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55A Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 52.58 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 2.5 A CH1 current range 0–3.5 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 13.4 V CH3 rated current 0.23 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 71% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 14.49–18.63 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific static-characteristics graph plots output voltage and ripple against 60 Hz AC input. It is not an additional load-versus-input curve or permission to operate outside the 88–264 VAC input range. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • ADD-55A

    MEAN WELL ADD-55 series: Dual-Output Power Supply with Battery Charger - ADD-55A

    MEAN WELL ADD-55A is a dual-output power supply with battery charger with 13.8 V / 5 V / 13.4 V channels and a total rated output of 52.58 W. The main load, 5 V auxiliary load and battery-charging channel share the unit’s power budget. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL ADD-55 Datasheet (PDF) The ADD-55 section is on PDF pages 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code ADD-55A Series ADD-55 Output arrangement Dual-Output Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the main DC load, CH2 supplies a separate 5 V load, and CH3 is the battery-charging channel. An external battery can provide the catalogue UPS function. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 52.58 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 2.5 A CH1 current range 0–3.5 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±1% CH1 load regulation ±1% CH2 function 5 V auxiliary output CH2 output voltage 5 V CH2 rated current 3 A CH2 current range 0–4 A CH2 ripple and noise maximum 100 mVp-p CH2 voltage tolerance ±3% CH2 line regulation ±0.5% CH2 load regulation ±0.5% CH3 function Battery-charging output CH3 output voltage 13.4 V CH3 rated current 0.23 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 71% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 14.49–18.63 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection Provided; numeric cutoff is not specified The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 DC/DC OUTPUT +5V Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific static-characteristics graph plots output voltage and ripple against 60 Hz AC input. It is not an additional load-versus-input curve or permission to operate outside the 88–264 VAC input range. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2002.7K hours minimum MTBF, MIL-HDBK-217F 373.8K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 570 g Catalogue packing 0.57 kg; 24 pcs / 13.7 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • AD-155C

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155C

    MEAN WELL AD-155C is a power supply with battery charger with 54 V / 53.5 V channels and a total rated output of 156.5 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155C Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 156.5 W CH1 voltage adjustment 48–58 V CH1 function Main regulated output CH1 output voltage 54 V CH1 rated current 2.7 A CH1 current range 0–2.7 A CH1 ripple and noise maximum 240 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 53.5 V CH2 rated current 0.2 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 84% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 62.1–72.9 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 39 V ±2 V Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-155C

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155C

    MEAN WELL AD-155C is a power supply with battery charger with 54 V / 53.5 V channels and a total rated output of 156.5 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155C Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 156.5 W CH1 voltage adjustment 48–58 V CH1 function Main regulated output CH1 output voltage 54 V CH1 rated current 2.7 A CH1 current range 0–2.7 A CH1 ripple and noise maximum 240 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 53.5 V CH2 rated current 0.2 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 84% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 62.1–72.9 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 39 V ±2 V Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-155B

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155B

    MEAN WELL AD-155B is a power supply with battery charger with 27.6 V / 27.1 V channels and a total rated output of 151.55 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155B Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 151.55 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 5 A CH1 current range 0–5.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 27.1 V CH2 rated current 0.5 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 84% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 19.5 V (+1.5 V / −1 V) Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-155B

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155B

    MEAN WELL AD-155B is a power supply with battery charger with 27.6 V / 27.1 V channels and a total rated output of 151.55 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155B Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 151.55 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 5 A CH1 current range 0–5.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 27.1 V CH2 rated current 0.5 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 84% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 19.5 V (+1.5 V / −1 V) Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-155A

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155A

    MEAN WELL AD-155A is a power supply with battery charger with 13.8 V / 13.3 V channels and a total rated output of 151.55 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155A Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 151.55 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 10.5 A CH1 current range 0–11.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±2% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 13.3 V CH2 rated current 0.5 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 80% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 10 V ±0.8 V Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific input derating plot at 60 Hz shows 80% load at 88 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply input and temperature limits together. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-155A

    MEAN WELL AD-155 series: Power Supply with Battery Charger - AD-155A

    MEAN WELL AD-155A is a power supply with battery charger with 13.8 V / 13.3 V channels and a total rated output of 151.55 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-155 Datasheet (PDF) The AD-155 section is on PDF pages 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-155A Series AD-155 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 151.55 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 10.5 A CH1 current range 0–11.5 A CH1 ripple and noise maximum 150 mVp-p CH1 voltage tolerance ±2% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 13.3 V CH2 rated current 0.5 A CH2 current range 0–0.5 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 80% Typical AC input current 2.5 A at 115 VAC; 1.5 A at 230 VAC Typical cold-start inrush current 23 A at 115 VAC; 45 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 1000 / 90 ms at 230 VAC; 2000 / 90 ms at 115 VAC, full load Typical hold-up time 24 ms at 230 VAC; 20 ms at 115 VAC, full load Switching frequency PFC 67 kHz; PWM 134 kHz Typical power factor >0.92 at full load Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Active PFC is built in. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–135% of rated output power Overload recovery AC charging mode: constant-current limiting with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Output shutdown; reapply power to recover Battery-low protection 10 V ±0.8 V Battery-polarity protection Provided CH2 overload threshold 0.51–0.9 A The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 NC Terminal 5 BAT. + Terminal 6 BAT.−/COM Terminal 7 DC OUTPUT COM Terminal 8 DC OUTPUT +V CN1 function, pins 1 and 2 RESET SW CN1 board connector JST B2B-XH or equivalent CN1 mating housing series JST XHP or equivalent CN1 contact JST SXH-001T-P0.6 or equivalent Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. CN1 is the reset-switch connection. Select a mating XHP housing for the illustrated two-position connector and the specified contact. Confirm reset-switch operation for the supplied unit before using the interface. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 50°C, decreasing to 50% at 60°C. With at least 21.6 CFM external airflow arranged 10 cm from the unit as shown, it permits 100% from −10 to 50°C and 80% at 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific input derating plot at 60 Hz shows 80% load at 88 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Apply input and temperature limits together. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 1818.3K hours minimum MTBF, MIL-HDBK-217F 229.9K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 199 × 110 × 50 mm (L × W × H) Case reference 906 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 880 g Catalogue packing 0.88 kg; 16 pcs / 15 kg / 0.95 CUFT The mechanical drawing marks 192 mm and 172 mm longitudinal references, a 97 mm vertical reference, 5-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. The specified JST board connector, mating housing series and contact are connection references. Confirm the complete mating housing and wire assembly before ordering installation parts. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

    $154.26

  • AD-55B

    MEAN WELL AD-55 series: Power Supply with Battery Charger - AD-55B

    MEAN WELL AD-55B is a power supply with battery charger with 27.6 V / 26.5 V channels and a total rated output of 53.92 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-55 Datasheet (PDF) The AD-55 section is on PDF pages 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-55B Series AD-55 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 53.92 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 1.8 A CH1 current range 0–2 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 26.5 V CH2 rated current 0.16 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 74% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection 20–22 V The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 NC Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2380.9K hours minimum MTBF, MIL-HDBK-217F 548.7K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 500 g Catalogue packing 0.5 kg; 24 pcs / 12.6 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • AD-55B

    MEAN WELL AD-55 series: Power Supply with Battery Charger - AD-55B

    MEAN WELL AD-55B is a power supply with battery charger with 27.6 V / 26.5 V channels and a total rated output of 53.92 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-55 Datasheet (PDF) The AD-55 section is on PDF pages 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-55B Series AD-55 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 53.92 W CH1 voltage adjustment 24–29 V CH1 function Main regulated output CH1 output voltage 27.6 V CH1 rated current 1.8 A CH1 current range 0–2 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 26.5 V CH2 rated current 0.16 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 74% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 31.74–37.26 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection 20–22 V The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 NC Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2380.9K hours minimum MTBF, MIL-HDBK-217F 548.7K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 500 g Catalogue packing 0.5 kg; 24 pcs / 12.6 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.

  • AD-55A

    MEAN WELL AD-55 series: Power Supply with Battery Charger - AD-55A

    MEAN WELL AD-55A is a power supply with battery charger with 13.8 V / 13.4 V channels and a total rated output of 51.38 W. The main load and battery-charging channel have distinct current limits. Apply the specified cooling and load limits. Product Datasheet Download MEAN WELL AD-55 Datasheet (PDF) The AD-55 section is on PDF pages 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Architecture Complete order code AD-55A Series AD-55 Output arrangement Power Supply with Battery Charger Input selection Universal AC input; no manual range-selection switch CH1 supplies the DC load and CH2 charges an external battery for the catalogue UPS function. The charging channel is not a second independently regulated load supply. Use the complete order code to select the voltage combination. The channel numbers identify circuits within one power supply, not separate products. Electrical Output Ratings Total rated output power 51.38 W CH1 voltage adjustment 12–14.5 V CH1 function Main regulated output CH1 output voltage 13.8 V CH1 rated current 3.5 A CH1 current range 0–4 A CH1 ripple and noise maximum 100 mVp-p CH1 voltage tolerance ±1% CH1 line regulation ±0.5% CH1 load regulation ±0.5% CH2 function Battery-charging output CH2 output voltage 13.4 V CH2 rated current 0.23 A The total rated power is shared by all listed channels. Observe the total-power, individual-current, adjustment and cooling limits together; the maximum values of different current ranges are not a simultaneous-output guarantee. CH1 adjustment does not establish an independently adjustable voltage range for the other channels. Check the connected load and, where used, the battery charging requirements before adjustment. Voltage tolerance includes setting tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted-pair lead terminated with 0.1 µF and 47 µF capacitors in parallel. Unlisted battery-channel ripple, regulation or current-range values are not specified as zero. Input and Timing AC input voltage 88–264 VAC DC input voltage 124–370 VDC AC input frequency 47–63 Hz Typical efficiency 71% Typical AC input current 1.6 A at 115 VAC; 1 A at 230 VAC Typical cold-start inrush current 20 A at 115 VAC; 40 A at 230 VAC Leakage current <1 mA at 240 VAC Set-up / rise time 800 / 50 ms at 230 VAC; 1600 / 50 ms at 115 VAC, full load Typical hold-up time 80 ms at 230 VAC; 16 ms at 115 VAC, full load Switching frequency 45 kHz Unless otherwise stated, catalogue parameters are measured at 230 VAC input, rated load and 25°C ambient. Timing values retain their stated input and load conditions. Connect the protective-earth terminal marked FG as shown in the wiring drawing. Protection and Battery Operation Short-circuit protection Provided Main-output overload threshold 105–150% of rated output power Overload recovery AC charging mode: hiccup with automatic recovery after fault removal; UPS mode: internal-fuse protection CH1 over-voltage threshold 15.87–18.63 V Over-voltage recovery Hiccup mode; automatic recovery after fault removal Battery-low protection 9.5–11 V The over-voltage threshold is specified for CH1. It is not a separately guaranteed over-voltage threshold for every auxiliary or charging channel. AC charging and battery-backup operation have different overload protection mechanisms. An internal-fuse response is not an automatic electronic restart. Check battery polarity and the battery manufacturer’s charging requirements before connection. Optional Alarm Output Alarm availability Optional configuration CN1 pin 1 Battery-low alarm below 82.5% ±2% of charge voltage CN1 pin 2 AC-fail alarm Normal alarm level 0.8 V maximum Abnormal alarm level 5 V ±0.5 V Order and confirm the alarm-equipped configuration when these signals are required. The alarm threshold is distinct from battery-discharge cutoff. Obtain the mating arrangement and signal reference for the supplied option before wiring. Terminal Assignments and Mating Parts Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG Terminal 4 DC OUTPUT COM Terminal 5 DC OUTPUT +V Terminal 6 BAT. + Terminal 7 BAT.−/COM Terminal 8 NC Use the numbered terminal view for this exact series. NC means no connection. DC COM is the output return; FG is protective earth. Do not interchange them. Connect the external battery only to BAT.+ and BAT.−/COM. The battery return and output common are identified in the terminal and block diagrams. Select wiring and battery protection for the actual installation. Environment, Cooling and Derating Working ambient temperature −10 to +60°C, subject to the applicable cooling curve Working humidity 20–90% RH, non-condensing Storage temperature −20 to +85°C Storage humidity 10–95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C on CH1 Vibration 10–500 Hz, 2G; 10 minutes/cycle, 60 minutes each along X, Y and Z For horizontal mounting without a fan, the curve permits 70% load from −10 to 40°C, decreasing to 50% at 50°C. The no-fan curve ends at 50°C. With at least 18.2 CFM external airflow arranged 10 cm from the unit as shown, the curve rises from 80% at −10°C to 100% at 0°C and remains at 100% through 60°C. Natural-convection operation does not mean unrestricted full rated power. Provide the specified external airflow when using the forced-air curve, and keep the ventilation path clear. Above 2000 m altitude, apply an additional ambient-temperature derating of 3.5°C per 1000 m for fanless models or 5°C per 1000 m for fan models, as specified in the catalogue installation note. The model-specific static-characteristics graph plots output voltage and ripple against 60 Hz AC input. It is not an additional load-versus-input curve or permission to operate outside the 88–264 VAC input range. Safety, EMC and Reliability Safety standards UL 62368-1; TÜV BS EN/EN 62368-1; AS/NZS 62368.1; EAC TP TC 004 approved Input-to-output withstand voltage 3 kVAC Input-to-FG withstand voltage 2 kVAC Output-to-FG withstand voltage 0.5 kVAC Isolation resistance 100 MΩ between I/P–O/P, I/P–FG and O/P–FG at 500 VDC, 25°C, 70% RH EMC emission BS EN/EN 55032 (CISPR 32), Class B; BS EN/EN 61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN 61000-4-2, -3, -4, -5, -6, -8, -11; BS EN/EN 55035, light-industry level; EAC TP TC 020 MTBF, Telcordia SR-332 2380.9K hours minimum MTBF, MIL-HDBK-217F 548.7K hours minimum at 25°C This power supply is a component for installation in final equipment. The catalogue EMC tests use a 360 × 360 mm metal plate, 1 mm thick. Verify EMC compliance again in the completed equipment. The catalogue lists 100% full-load burn-in testing and a two-year warranty. MTBF is a reliability calculation, not a guaranteed operating lifetime. Mechanical Installation and Related Equipment Catalogue dimensions 159 × 97 × 38 mm (L × W × H) Case reference 901 Drawing dimensional tolerance ±1 mm Catalogue unit-weight reference 500 g Catalogue packing 0.5 kg; 24 pcs / 12.6 kg / 0.83 CUFT The mechanical drawing marks a 152.5 mm longitudinal mounting reference, 84.5 mm vertical reference, 2-M3 bottom holes, 3-M3 side holes and Ø3.5 mm holes. Use the exact drawing positions and keep clearance around the terminal block. The unit weight is the catalogue PACKING reference per unit, not a measured net or shipping weight. Carton quantities and carton weight are separate packing references. Select external wiring, ventilation and installation hardware to suit the actual load and enclosure. The cooling fan illustrated in the airflow setup is external; the drawing does not establish an included fan or a separate fan order code. An external battery is required for backup operation. Choose it for the stated charging voltage and current and the required backup duration; the catalogue does not prescribe a complete battery order code or guarantee a backup time.


You have seen 24 out of 67 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa