RPD , RPT , RPTG : Medical Open Frame Power Supply ; MPQ : Medical Grade Output Power Supply

102 products

MEAN WELL Medical Multi-Output Power Supply (RPD/RPT/MPQ Series)

  • Product Features
  • General Specifications
  • Output Models Overview
  • Product Ordering Code

Product Features

  • Medical Safety Certified: 2 x MOPP (Primary to Secondary) compliant with IEC/EN60601-1 and ANSI/AAMI ES60601-1.
  • Multi-Channel Output: Supports Dual (RPD), Triple (RPT), and Quad (MPQ) output configurations for complex system requirements.
  • High Efficiency & PFC: Features active PFC function (for higher wattage models) and high-efficiency circuit design.
  • Low Leakage: Ultra-low leakage current (<100µA to <160µA), ideal for BF (Body Floating) medical equipment.
  • Flexible Cooling: Supports dual power ratings (natural convection vs. forced air cooling with CFM ratings).
  • Advanced Control: Select models (RPT-160G) include 5V auxiliary standby and PS-ON control signal.
  • Diverse Mounting: Compact bare PCB designs with optional enclosed (-C) covers.
  • Comprehensive Protection: Built-in short circuit, overload, over voltage, and over temperature (on select models) protections.

General Specifications

Item Specification Description
Input Voltage 90 ~ 264VAC / 127 ~ 370VDC (Universal Input)
Frequency 47 ~ 63Hz
Isolation I/P-O/P: 2xMOPP; I/P-FG: 1xMOPP; O/P-FG: 1xMOPP
Withstand Voltage I/P-O/P: 4KVAC; I/P-FG: 2KVAC; O/P-FG: 1.5KVAC
Working Temp. -20°C ~ +70°C (Refer to specific model derating curve)
Safety Standards IEC 60601-1, TUV/EN 60601-1, ANSI/AAMI ES60601-1, EAC, UL62368-1
EMC Emission BS EN/EN55011 (CISPR11) Class B

Output Models Overview

RPD & RPT Series (50W - 160W)

Series Configuration Max Power
RPD-60/65/75 Dual Output (e.g., 5V/12V, 24V) 50W - 75W
RPT-60/65/75 Triple Output (e.g., 5V/12V/-5V) 40W - 75W
RPT-160 Triple Output (w/ PFC/Standby) 98W (Conv.) / 145W (CFM)

MPQ-200 Series (200W Quad Output)

Model CH1 CH2 CH3 CH4
MPQ-200B 5V/15A 12V/7A -5V/2A -12V/2A
MPQ-200D 5V/15A 24V/3A 12V/2A -12V/2A
Note: MPQ-200 series requires 25CFM forced air cooling to achieve rated output currents.

Product Ordering Code

No. Item Description
1 Series RPD (Dual), RPT (Triple), MPQ (Quad)
2 Control Option Blank (Standard); G (w/ 5Vsb & PS-ON for RPT-160)
3 Rated Power 60W, 65W, 75W, 160W, 200W
4 Config Voltage combination identifier (A, B, C, D, F, etc.)
5 Enclosure Blank (Bare PCB); -C (Enclosed w/ cover)
Example: RPTG-160B-C (160W Triple Output, 5Vsb/PS-ON, Enclosed).
  • RPTG-160C

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160C

    MEAN WELL RPTG-160C is a PCB open-frame triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 143 W with 20.5 CFM airflow and 99 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160C. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 143 W, as printed in the model table. Combined rated power, convection 99 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.6 A. Load-current range, 20.5 CFM 0.1–3.6 A. Load-current range, convection 0.1–2.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPT-160C

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160C

    MEAN WELL RPT-160C is a PCB open-frame triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 143 W with 20.5 CFM airflow and 99 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160C. Configuration Standard pcb type. No G: basic-function model. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 143 W, as printed in the model table. Combined rated power, convection 99 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.6 A. Load-current range, 20.5 CFM 0.1–3.6 A. Load-current range, convection 0.1–2.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160C

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160C

    MEAN WELL RPT-160C is a PCB open-frame triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 143 W with 20.5 CFM airflow and 99 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160C. Configuration Standard pcb type. No G: basic-function model. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 143 W, as printed in the model table. Combined rated power, convection 99 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.6 A. Load-current range, 20.5 CFM 0.1–3.6 A. Load-current range, convection 0.1–2.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160C

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160C

    MEAN WELL RPT-160C is a PCB open-frame triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 143 W with 20.5 CFM airflow and 99 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160C. Configuration Standard pcb type. No G: basic-function model. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 143 W, as printed in the model table. Combined rated power, convection 99 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.6 A. Load-current range, 20.5 CFM 0.1–3.6 A. Load-current range, convection 0.1–2.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPTG-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160B

    MEAN WELL RPTG-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160B. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160B

    MEAN WELL RPTG-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160B. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160B

    MEAN WELL RPTG-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160B. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPT-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160B

    MEAN WELL RPT-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160B. Configuration Standard pcb type. No G: basic-function model. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160B

    MEAN WELL RPT-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160B. Configuration Standard pcb type. No G: basic-function model. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160B

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160B

    MEAN WELL RPT-160B is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −12 V rails. The catalogue combined ratings are 146 W with 20.5 CFM airflow and 98.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160B. Configuration Standard pcb type. No G: basic-function model. Output code B: CH1 / CH2 / CH3 = 5 V / 12 V / −12 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 146 W, as printed in the model table. Combined rated power, convection 98.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5 A. Load-current range, 20.5 CFM 0.2–5 A. Load-current range, convection 0.2–3.4 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.8 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -4% / +5%. Line regulation ±1.0%. Load regulation -4% / +5%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPTG-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160A

    MEAN WELL RPTG-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160A. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160A

    MEAN WELL RPTG-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160A. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPTG-160A

    MEAN WELL RPTG-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160A. Configuration Standard pcb type. G: green model with standby and PS-ON. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPT-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160A

    MEAN WELL RPT-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160A. Configuration Standard pcb type. No G: basic-function model. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160A

    MEAN WELL RPT-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160A. Configuration Standard pcb type. No G: basic-function model. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160A

    MEAN WELL RPT-160 series: Open-Frame Triple Output Medical AC/DC Power Supply - RPT-160A

    MEAN WELL RPT-160A is a PCB open-frame triple-output AC/DC power supply with 5 V / 12 V / −5 V rails. The catalogue combined ratings are 145 W with 20.5 CFM airflow and 98.6 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160A. Configuration Standard pcb type. No G: basic-function model. Output code A: CH1 / CH2 / CH3 = 5 V / 12 V / −5 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The listed component approvals do not certify the finished medical equipment. Combined Output and Test Conditions Combined rated power, 20.5 CFM 145 W, as printed in the model table. Combined rated power, convection 98.6 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 84%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. The 98.6 W figure is the catalogue combined rating; it does not permit exceeding the individual current limits. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 14 A. Load-current range, 20.5 CFM 0.6–14 A. Load-current range, convection 0.6–9 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 5.5 A. Load-current range, 20.5 CFM 0.2–5.5 A. Load-current range, convection 0.2–3.8 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 V relative to COM. Rated current, 20.5 CFM 1 A. Load-current range, 20.5 CFM 0.1–1 A. Load-current range, convection 0.1–0.6 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5% / +7%. Line regulation ±1.0%. Load regulation -5% / +6%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve The PCB convection curve is 100% through 40°C and falls to 40% at 60°C; with 20.5 CFM it is 100% through 50°C and falls to 40% at 70°C. Apply each curve to its stated cooling mode and retain the individual channel and combined-power limits. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 127 × 76.2 × 34.6 mm. Drawing PDF page 23; dimensions in millimetres. Board mounting Four Ø3.5 mm holes on a 117 × 66.2 mm pattern, with 5 mm edge offsets. Height and underside 34.6 mm body height; maximum underside projection 3 mm. Provide the full clearance shown in the drawing. External airflow placement At least 20.5 CFM external fan, 5 cm from the PCB, blowing in the shown direction; fan centre is referenced 63.5 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional additional approval. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the PCB EMI note specifies Class I with FG, and both safety-ground points must be connected. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 330 g (0.33 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 36 pieces / 12.9 kg / 0.96 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-7503

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-7503

    MEAN WELL RPT-7503 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 61.8 W combined rated output power. The higher 81.1 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-7503. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 61.8 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.7–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +3/-4%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-4%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0–1.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.5%. Load regulation ±6.0%. Output Loading and Measurement Combined rated output power 61.8 W. Higher output with forced cooling 81.1 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 74%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.5 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-7503

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-7503

    MEAN WELL RPT-7503 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 61.8 W combined rated output power. The higher 81.1 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-7503. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 61.8 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.7–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +3/-4%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-4%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0–1.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.5%. Load regulation ±6.0%. Output Loading and Measurement Combined rated output power 61.8 W. Higher output with forced cooling 81.1 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 74%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.5 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-7503

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-7503

    MEAN WELL RPT-7503 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 61.8 W combined rated output power. The higher 81.1 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-7503. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 61.8 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.7–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +3/-4%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-4%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0–1.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.5%. Load regulation ±6.0%. Output Loading and Measurement Combined rated output power 61.8 W. Higher output with forced cooling 81.1 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 74%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.5 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75D

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75D

    MEAN WELL RPT-75D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 73 W combined rated output power. The higher 95 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 73 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.6–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. Output Loading and Measurement Combined rated output power 73 W. Higher output with forced cooling 95 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 79%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75D

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75D

    MEAN WELL RPT-75D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 73 W combined rated output power. The higher 95 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 73 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.6–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. Output Loading and Measurement Combined rated output power 73 W. Higher output with forced cooling 95 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 79%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75D

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75D

    MEAN WELL RPT-75D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 73 W combined rated output power. The higher 95 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 73 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.6–7 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. Output Loading and Measurement Combined rated output power 73 W. Higher output with forced cooling 95 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 79%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75C

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75C

    MEAN WELL RPT-75C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 2.3 A. Current range 0.1–3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75C

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75C

    MEAN WELL RPT-75C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 2.3 A. Current range 0.1–3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.