  • Product Features
  • General Specifications
  • Output Models Overview
  • Product Ordering Code

Product Features

  • Medical Safety Certified: 2 x MOPP (Primary to Secondary) compliant with IEC/EN60601-1 and ANSI/AAMI ES60601-1.
  • Multi-Channel Output: Supports Dual (RPD), Triple (RPT), and Quad (MPQ) output configurations for complex system requirements.
  • High Efficiency & PFC: Features active PFC function (for higher wattage models) and high-efficiency circuit design.
  • Low Leakage: Ultra-low leakage current (<100µA to <160µA), ideal for BF (Body Floating) medical equipment.
  • Flexible Cooling: Supports dual power ratings (natural convection vs. forced air cooling with CFM ratings).
  • Advanced Control: Select models (RPT-160G) include 5V auxiliary standby and PS-ON control signal.
  • Diverse Mounting: Compact bare PCB designs with optional enclosed (-C) covers.
  • Comprehensive Protection: Built-in short circuit, overload, over voltage, and over temperature (on select models) protections.

General Specifications

Item Specification Description
Input Voltage 90 ~ 264VAC / 127 ~ 370VDC (Universal Input)
Frequency 47 ~ 63Hz
Isolation I/P-O/P: 2xMOPP; I/P-FG: 1xMOPP; O/P-FG: 1xMOPP
Withstand Voltage I/P-O/P: 4KVAC; I/P-FG: 2KVAC; O/P-FG: 1.5KVAC
Working Temp. -20°C ~ +70°C (Refer to specific model derating curve)
Safety Standards IEC 60601-1, TUV/EN 60601-1, ANSI/AAMI ES60601-1, EAC, UL62368-1
EMC Emission BS EN/EN55011 (CISPR11) Class B

Output Models Overview

RPD & RPT Series (50W - 160W)

Series Configuration Max Power
RPD-60/65/75 Dual Output (e.g., 5V/12V, 24V) 50W - 75W
RPT-60/65/75 Triple Output (e.g., 5V/12V/-5V) 40W - 75W
RPT-160 Triple Output (w/ PFC/Standby) 98W (Conv.) / 145W (CFM)

MPQ-200 Series (200W Quad Output)

Model CH1 CH2 CH3 CH4
MPQ-200B 5V/15A 12V/7A -5V/2A -12V/2A
MPQ-200D 5V/15A 24V/3A 12V/2A -12V/2A
Note: MPQ-200 series requires 25CFM forced air cooling to achieve rated output currents.

Product Ordering Code

No. Item Description
1 Series RPD (Dual), RPT (Triple), MPQ (Quad)
2 Control Option Blank (Standard); G (w/ 5Vsb & PS-ON for RPT-160)
3 Rated Power 60W, 65W, 75W, 160W, 200W
4 Config Voltage combination identifier (A, B, C, D, F, etc.)
5 Enclosure Blank (Bare PCB); -C (Enclosed w/ cover)
Example: RPTG-160B-C (160W Triple Output, 5Vsb/PS-ON, Enclosed).
  • RPT-75C

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75C

    MEAN WELL RPT-75C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 2.3 A. Current range 0.1–3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75B

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75B

    MEAN WELL RPT-75B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75B

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75B

    MEAN WELL RPT-75B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75B

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75B

    MEAN WELL RPT-75B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 72 W combined rated output power. The higher 100 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 72 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 72 W. Higher output with forced cooling 100 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 77%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75A

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75A

    MEAN WELL RPT-75A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 68.5 W combined rated output power. The higher 93 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 68.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 68.5 W. Higher output with forced cooling 93 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 76%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75A

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75A

    MEAN WELL RPT-75A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 68.5 W combined rated output power. The higher 93 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 68.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 68.5 W. Higher output with forced cooling 93 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 76%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-75A

    MEAN WELL RPT-75 series: Triple-Output Medical AC/DC Power Supply - RPT-75A

    MEAN WELL RPT-75A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 68.5 W combined rated output power. The higher 93 W rating requires 23.5 CFM forced airflow; apply the model-specific output limits and thermal curves. Product Datasheet Download MEAN WELL RPT-75 Datasheet (PDF) The RPT-75 section is on PDF pages 14, 15, 16, 17, 18. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-75A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 5 × 3-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 68.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 6 A. Current range 0.6–8 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.2–4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±1.0%. Output Loading and Measurement Combined rated output power 68.5 W. Higher output with forced cooling 93 W total with 23.5 CFM airflow. The specification labels this row “PEAK LOAD (23.5 CFM)”; use it with the forced-air thermal curve. Efficiency, typical 76%. CH1 voltage adjustment 4.75–5.5 V. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The higher rating is cooling-dependent. No 10-second or 33% duty rule is stated for this series; do not substitute another series’ peak-time rule. The family thermal diagram uses 72 W and 100 W reference labels; use this exact model’s combined wattages above. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 ms / 30 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 140–180% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.7–6.8 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 70°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 60°C. The natural-convection curve ends at 60°C. 23.5 CFM thermal curve The family diagram holds the 133% reference level from −20°C through 50°C, then slopes to 50% at 70°C. Apply the exact model’s higher wattage limit and all channel limits as well. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope Design refers to BS EN/EN 60335-1 by request; not represented as an unconditional approval. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 127 × 76.2 × 31 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.8 mm; 115.8 × 64.75 mm centre spacing; 5.6 mm and 5.7 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2, HS3. Input fuses FS1 and FS2: T2.5 A / 250 V AC. For the higher forced-air rating, the mechanical drawing places a fan delivering at least 23.5 CFM 15 cm from the PCB and centred along its long side. Follow the illustrated airflow arrangement. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B8P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = COM; pin 6 = V2; pin 7 = V2; pin 8 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 2305.8 thousand hours, Telcordia SR-332; 521.3 thousand hours, MIL-HDBK-217F at 25°C. Series lifetime feature The catalogue lists a lifetime greater than 140,000 hours; this feature is separate from the stated MTBF methods. Catalogue single-unit weight 250 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.25 kg per unit; 63 pieces / 17.3 kg / 1.28 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-6003

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-6003

    MEAN WELL RPT-6003 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 39.9 W combined rated output power. Its 43.89 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-6003. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 39.9 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.5–5.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.3–3.3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.7 A. Current range 0.1–0.77 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation +5.5/-5%. Output Loading and Measurement Combined rated output power 39.9 W. Short-time peak output 43.89 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 39.9 W. Efficiency, typical 75%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.45 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-6003

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-6003

    MEAN WELL RPT-6003 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 39.9 W combined rated output power. Its 43.89 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-6003. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 39.9 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.5–5.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.3–3.3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.7 A. Current range 0.1–0.77 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation +5.5/-5%. Output Loading and Measurement Combined rated output power 39.9 W. Short-time peak output 43.89 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 39.9 W. Efficiency, typical 75%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.45 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-6003

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-6003

    MEAN WELL RPT-6003 is a triple-output, open-frame medical AC/DC power supply with 3.3 V / 5 V / 12 V outputs and 39.9 W combined rated output power. Its 43.89 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-6003. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 39.9 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 3.3 V relative to COM; retain the indicated polarity. Rated current 5 A. Current range 0.5–5.5 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3 A. Current range 0.3–3.3 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.7 A. Current range 0.1–0.77 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation +5.5/-5%. Output Loading and Measurement Combined rated output power 39.9 W. Short-time peak output 43.89 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 39.9 W. Efficiency, typical 75%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 3.8–4.45 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60D

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60D

    MEAN WELL RPT-60D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 47.5 W combined rated output power. Its 52.25 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 47.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3.5 A. Current range 0.5–3.85 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1.1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 47.5 W. Short-time peak output 52.25 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 47.5 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60D

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60D

    MEAN WELL RPT-60D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 47.5 W combined rated output power. Its 52.25 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 47.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3.5 A. Current range 0.5–3.85 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1.1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 47.5 W. Short-time peak output 52.25 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 47.5 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60D

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60D

    MEAN WELL RPT-60D is a triple-output, open-frame medical AC/DC power supply with 5 V / 24 V / 12 V outputs and 47.5 W combined rated output power. Its 52.25 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60D. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 47.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 3.5 A. Current range 0.5–3.85 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 24 V relative to COM; retain the indicated polarity. Rated current 1 A. Current range 0.1–1.1 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 47.5 W. Short-time peak output 52.25 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 47.5 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60C

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60C

    MEAN WELL RPT-60C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–1.65 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60C

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60C

    MEAN WELL RPT-60C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–1.65 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60C

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60C

    MEAN WELL RPT-60C is a triple-output, open-frame medical AC/DC power supply with 5 V / 15 V / -15 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60C. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 15 V relative to COM; retain the indicated polarity. Rated current 1.5 A. Current range 0.1–1.65 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±3.0%. CH3 Output Nominal DC voltage -15 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±8.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±4.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 79%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60B

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60B

    MEAN WELL RPT-60B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±5.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 78%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60B

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60B

    MEAN WELL RPT-60B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±5.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 78%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60B

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60B

    MEAN WELL RPT-60B is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -12 V outputs and 50 W combined rated output power. Its 55 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60B. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 50 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -12 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 100 mVp-p. Voltage tolerance +10/-6%, including set-up tolerance, line regulation and load regulation. Line regulation ±2.0%. Load regulation ±5.0%. Output Loading and Measurement Combined rated output power 50 W. Short-time peak output 55 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 50 W. Efficiency, typical 78%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60A

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60A

    MEAN WELL RPT-60A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 46.5 W combined rated output power. Its 51.15 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 46.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +9/-8%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-7%. Output Loading and Measurement Combined rated output power 46.5 W. Short-time peak output 51.15 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 46.5 W. Efficiency, typical 77%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60A

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60A

    MEAN WELL RPT-60A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 46.5 W combined rated output power. Its 51.15 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 46.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +9/-8%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-7%. Output Loading and Measurement Combined rated output power 46.5 W. Short-time peak output 51.15 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 46.5 W. Efficiency, typical 77%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPT-60A

    MEAN WELL RPT-60 series: Triple-Output Medical AC/DC Power Supply - RPT-60A

    MEAN WELL RPT-60A is a triple-output, open-frame medical AC/DC power supply with 5 V / 12 V / -5 V outputs and 46.5 W combined rated output power. Its 51.15 W short-time peak requires the stated 10-second and duty-cycle limits. Product Datasheet Download MEAN WELL RPT-60 Datasheet (PDF) The RPT-60 section is on PDF pages 9, 10, 11, 12, 13. Refer to the complete mechanical drawings and notes when planning installation. Model and Selection Complete model RPT-60A. The suffix identifies the three-output voltage combination; all three channels belong to one power supply. Construction and use 4 × 2-inch PCB footprint; Class I installation with protective earth. Medical applications include oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. BF use requires appropriate consideration in the complete system. Combined power limit 46.5 W total across CH1–CH3 at rated conditions. Respect each channel current, its minimum load, the combined power limit and the derating curves simultaneously. CH1 Output Nominal DC voltage 5 V relative to COM; retain the indicated polarity. Rated current 4 A. Current range 0.5–4.4 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +3/-2%, including set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal DC voltage 12 V relative to COM; retain the indicated polarity. Rated current 2 A. Current range 0.1–2.2 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±6.0%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation ±2.0%. CH3 Output Nominal DC voltage -5 V relative to COM; retain the indicated polarity. Rated current 0.5 A. Current range 0.1–0.55 A. The lower bound is the specified minimum load; the upper bound does not override the combined power or cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance +9/-8%, including set-up tolerance, line regulation and load regulation. Line regulation ±1.0%. Load regulation +5/-7%. Output Loading and Measurement Combined rated output power 46.5 W. Short-time peak output 51.15 W total; maximum 10 seconds, 33% duty within every 30-second period, and average power no greater than 46.5 W. Efficiency, typical 77%. CH1 voltage adjustment No adjustment range is specified for this model in the output table. Values are measured at 230 VAC, rated load and 25°C unless otherwise stated. Ripple/noise is measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. The power limits are for the complete three-output unit, not separate wattage allowances for each channel. A maximum current printed for one output does not permit all channels to exceed the combined rating. Input and Timing Input voltage and frequency 90–264 VAC or 127–370 VDC; 47–63 Hz AC. Apply the input derating curve. Input current, typical 1.1 A at 115 VAC; 0.7 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. Set-up / rise time 300 ms / 15 ms at both 230 VAC and 115 VAC, full load. Hold-up time, typical 70 ms at 230 VAC; 15 ms at 115 VAC, full load. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC, measured from primary input to DC output. Set-up and rise-time figures use a cold first start. Repeated rapid on/off operation can increase the set-up time. Protection Short circuit and overload Overload at 115–150% of rated output power. Hiccup protection recovers automatically after the fault is removed. CH1 overvoltage 5.75–6.75 V; output shuts down and requires re-power on to recover. Cooling and Environment Temperature operating range −20 to 65°C, subject to the cooling and load curves. Horizontal natural-convection curve 100% load from −20°C through 40°C, decreasing to 50% at 65°C. Input-voltage curve at 60 Hz 80% load at 90 VAC, rising to 100% at 115 VAC and remaining at 100% through 264 VAC. Operating altitude Up to 3000 m. Above 2000 m, reduce the permissible ambient temperature by 3.5°C per 1000 m for fanless operation or 5°C per 1000 m for fan-cooled operation. Humidity Operating: 20–90% RH, non-condensing. Storage: −40 to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes along each of the X, Y and Z axes. Apply input-voltage, ambient-temperature and combined-output limits together. Do not interpret one curve as permission to exceed another applicable limit. Safety and Insulation Medical safety approvals IEC 60601-1:2005 + A1 + A2; TUV BS EN/EN 60601-1:2006 + A1 + A12 + A2; ANSI/AAMI ES60601-1:2005 + A2; CAN/CSA-C22.2 No. 60601-1:2014 + A2; EAC TP TC 004. Other safety scope IEC 62368-1:2014; UL 62368-1, 2nd Edition; CSA C22.2 No. 62368-1-14, 2nd Edition; TUV BS EN/EN 62368-1:2014 + A11. Isolation level Primary to secondary: 2 MOPP; primary to earth: 1 MOPP; secondary to earth: 1 MOPP. Withstand voltage Input/output: 4 kVAC; input/FG: 2 kVAC; output/FG: 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH for input/output, input/FG and output/FG. These are power-supply component ratings. Medical BF suitability and regulatory compliance must be assessed in the finished equipment and its actual installation. Electromagnetic Compatibility Emissions BS EN/EN 55011 Class B conducted and radiated emissions; BS EN/EN 61000-3-2 Class A harmonic current; BS EN/EN 61000-3-3 voltage fluctuations and flicker. Immunity framework BS EN/EN 55035 and BS EN/EN 60601-1-2. Electrostatic discharge IEC 61000-4-2: 15 kV air / 8 kV contact, level 4. Radiated RF IEC 61000-4-3: 10 V/m, 80 MHz–2.7 GHz, level 3; the medical table-9 tests use 9–28 V/m at 385 MHz–5.78 GHz. EFT and surge IEC 61000-4-4: 2 kV, level 3. IEC 61000-4-5: 4 kV line-to-FG / 2 kV line-to-line, level 4. Conducted RF and magnetic field IEC 61000-4-6: 10 V, level 3. IEC 61000-4-8: 30 A/m, level 4. Dips and interruptions IEC 61000-4-11: voltage dips of 100% for 1 period and 30% for 25 periods; interruptions of 100% for 250 periods. The EMC test mounts the power supply on a 360 × 360 × 1 mm metal plate. Reconfirm EMC in the complete equipment; the component test does not replace finished-system testing. Mechanical Installation Overall dimensions 101.6 × 50.8 × 29 mm (L × W × H). General drawing tolerance: ±1 mm. Mounting holes 4 × Ø3.3 mm; 95.25 × 44.45 mm centre spacing; 3.175 mm edge offsets. Use the full mechanical drawing for locations; the underside drawing shows 3 mm maximum. Protective earth M1 is the safety-grounding point. M1 and M2 should have secure electrical contact with chassis ground for better EMC. Heat-sink caution Do not short HS1, HS2. Input fuses FS1 and FS2: T2.5 A / 250 V AC. Connections and Mating Components CN1 AC input JST B3P-VH or equivalent. pin 1 = AC/N; pin 2 = No pin; pin 3 = AC/L. CN2 DC output JST B6P-VH or equivalent. pin 1 = V1; pin 2 = V1; pin 3 = COM; pin 4 = COM; pin 5 = V2; pin 6 = V3. Mating housings JST VHR or equivalent (family code as printed). Mating terminals JST SVH-21T-P1.1 or equivalent. Connector and terminal references identify the mating components shown in the catalogue. They are not a statement that loose housings, terminals, cables or an external fan are included. Select the full VHR housing reference to match the circuit count and wire assembly shown in the drawing. Reliability and Weight MTBF 4415.3 thousand hours, Telcordia SR-332; 677.8 thousand hours, MIL-HDBK-217F at 25°C. Catalogue single-unit weight 150 g, taken from the first per-unit value in PACKING; a catalogue reference, not a measured shipping weight. Packing reference 0.15 kg per unit; 96 pieces / 15.4 kg / 0.89 CUFT. Manufacturer warranty The manufacturer datasheet lists a three-year warranty. Applicable manufacturer terms govern; this is not an additional seller warranty promise.

  • RPD-75B

    MEAN WELL RPD-75 series: Dual-Output Medical AC/DC Power Supply - RPD-75B

    MEAN WELL RPD-75B is a PCB-type dual-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V. The rated combined output is 73 W. The catalogue 98.8 W higher-load rating requires 23.5 CFM forced airflow and the applicable thermal limits. Product Datasheet Download MEAN WELL RPD-75 Datasheet (PDF) The RPD-75 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model RPD-75B Output arrangement 2 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Rated combined output 73 W; both channels share this total. Catalogue higher-load rating 98.8 W with 23.5 CFM forced air, labelled peak load in the catalogue. CH1 voltage adjustment 4.75–5.5 V. No independent CH2 adjustment range is specified. The RPD-75 higher-load rating requires 23.5 CFM forced cooling. A separate timed-pulse operating rating is not specified for this family. Meet each channel minimum load and its current limit while respecting the combined wattage limit. The upper current-range values do not replace the continuous total-power rating. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 5 A. Minimum load 1 A. Specified current range 1–6.8 A; observe the total-power and forced-cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2 A. Minimum load 0.2 A. Specified current range 0.2–2.7 A; observe the total-power and forced-cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Switching-frequency reference 65 kHz. Set-up time is measured at cold start; repeated ON/OFF operation may increase it. Protection Short circuit / overload Hiccup protection at 140–180% rated output power, with automatic recovery after the fault is removed. Overvoltage protection CH1: 5.7–6.8 V. Output shuts down; re-power to recover. Protection thresholds are fault limits, not additional operating ratings. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal natural convection: 100% through 40°C, falling to 50% at 60°C. With 23.5 CFM forced air, the family plot shows 133% through 50°C and 50% at 70°C. Apply the separate exact model wattage and current ratings as well; the convection curve does not extend to 70°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 100 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Operating altitude up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.8 mm on 115.8 × 64.75 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references 5.6 mm and 5.7 mm edge references; M1 is safety ground. Secure electrical connection between M1, M2 and chassis ground for EMC. Forced-air installation At least 23.5 CFM, fan 15 cm from the illustrated board edge; fan centre reference 63.5 mm. Heat sinks and fuses HS1, HS2 and HS3 must not be shorted. The AC fuses FS1/FS2 are marked T2.5/250V; no complete replacement-fuse ordering code is supplied. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. These RPD models require a Class I installation with protective ground (FG). Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent: pins 1–2 V1, 3–5 COM, 6–7 V2, 8 NC. NC means no connection, not a third output. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP; primary–earth: 1 MOPP. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional standard-product approval. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 (CISPR11) Class B for the specified Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Immunity framework: BS EN/EN55035 and BS EN/EN60601-1-2. The listed immunity tests are EN61000-4-2 ESD Level 4, 15 kV air / 8 kV contact; EN61000-4-3 RF Level 3, 10 V/m at 80 MHz–2.7 GHz and Table 9, 9–28 V/m at 385 MHz–5.78 GHz; EN61000-4-4 EFT Level 3, 2 kV; EN61000-4-5 surge Level 3, 4 kV line–FG / 2 kV line–line; EN61000-4-6 conducted susceptibility Level 3, 10 V; EN61000-4-8 magnetic field Level 4, 30 A/m; EN61000-4-11 100% dip for 1 period, 30% dip for 25 periods and 100% interruption for 250 periods. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.25 kg = 250 g per unit, from the PACKING entry. Carton reference 63 pieces / 17.3 kg / 1.28 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 2575.6 K hours, Telcordia SR-332 (Bellcore); 569.9 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition RPD-75-SPEC 2024-11-22; combined PDF pages 5–8. The RPD-75 features list a lifetime greater than 140,000 hours; this is a catalogue reliability statement, distinct from MTBF and not an unconditional service-life guarantee. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

  • RPD-75B

    MEAN WELL RPD-75 series: Dual-Output Medical AC/DC Power Supply - RPD-75B

    MEAN WELL RPD-75B is a PCB-type dual-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V. The rated combined output is 73 W. The catalogue 98.8 W higher-load rating requires 23.5 CFM forced airflow and the applicable thermal limits. Product Datasheet Download MEAN WELL RPD-75 Datasheet (PDF) The RPD-75 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model RPD-75B Output arrangement 2 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Rated combined output 73 W; both channels share this total. Catalogue higher-load rating 98.8 W with 23.5 CFM forced air, labelled peak load in the catalogue. CH1 voltage adjustment 4.75–5.5 V. No independent CH2 adjustment range is specified. The RPD-75 higher-load rating requires 23.5 CFM forced cooling. A separate timed-pulse operating rating is not specified for this family. Meet each channel minimum load and its current limit while respecting the combined wattage limit. The upper current-range values do not replace the continuous total-power rating. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 5 A. Minimum load 1 A. Specified current range 1–6.8 A; observe the total-power and forced-cooling limits. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2 A. Minimum load 0.2 A. Specified current range 0.2–2.7 A; observe the total-power and forced-cooling limits. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up / rise time 500 / 30 ms at 230 VAC; 500 / 30 ms at 115 VAC, full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, full load. Switching-frequency reference 65 kHz. Set-up time is measured at cold start; repeated ON/OFF operation may increase it. Protection Short circuit / overload Hiccup protection at 140–180% rated output power, with automatic recovery after the fault is removed. Overvoltage protection CH1: 5.7–6.8 V. Output shuts down; re-power to recover. Protection thresholds are fault limits, not additional operating ratings. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal natural convection: 100% through 40°C, falling to 50% at 60°C. With 23.5 CFM forced air, the family plot shows 133% through 50°C and 50% at 70°C. Apply the separate exact model wattage and current ratings as well; the convection curve does not extend to 70°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 100 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Operating altitude up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.8 mm on 115.8 × 64.75 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references 5.6 mm and 5.7 mm edge references; M1 is safety ground. Secure electrical connection between M1, M2 and chassis ground for EMC. Forced-air installation At least 23.5 CFM, fan 15 cm from the illustrated board edge; fan centre reference 63.5 mm. Heat sinks and fuses HS1, HS2 and HS3 must not be shorted. The AC fuses FS1/FS2 are marked T2.5/250V; no complete replacement-fuse ordering code is supplied. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. These RPD models require a Class I installation with protective ground (FG). Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent: pins 1–2 V1, 3–5 COM, 6–7 V2, 8 NC. NC means no connection, not a third output. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP; primary–earth: 1 MOPP. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional standard-product approval. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 (CISPR11) Class B for the specified Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Immunity framework: BS EN/EN55035 and BS EN/EN60601-1-2. The listed immunity tests are EN61000-4-2 ESD Level 4, 15 kV air / 8 kV contact; EN61000-4-3 RF Level 3, 10 V/m at 80 MHz–2.7 GHz and Table 9, 9–28 V/m at 385 MHz–5.78 GHz; EN61000-4-4 EFT Level 3, 2 kV; EN61000-4-5 surge Level 3, 4 kV line–FG / 2 kV line–line; EN61000-4-6 conducted susceptibility Level 3, 10 V; EN61000-4-8 magnetic field Level 4, 30 A/m; EN61000-4-11 100% dip for 1 period, 30% dip for 25 periods and 100% interruption for 250 periods. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.25 kg = 250 g per unit, from the PACKING entry. Carton reference 63 pieces / 17.3 kg / 1.28 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 2575.6 K hours, Telcordia SR-332 (Bellcore); 569.9 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition RPD-75-SPEC 2024-11-22; combined PDF pages 5–8. The RPD-75 features list a lifetime greater than 140,000 hours; this is a catalogue reliability statement, distinct from MTBF and not an unconditional service-life guarantee. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.