xln

84 products

  • XLC-60-H-DA2SN

    MEAN WELL XLC-60 series: constant-power LED driver with DALI-2 and PUSH dimming - XLC-60-H-DA2SN

    MEAN WELL XLC-60-H-DA2SN XLC-60-H-DA2SN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-DA2SN; Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. For the IEC 62386-101/102 timing test, use a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 seconds. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces loading to 75%; stage 2 to 50%. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-BSN

    MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-BSN

    MEAN WELL XLC-60-H-BSN XLC-60-H-BSN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Independent type with strain-relief caps (S). 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-BSN; Independent type with strain-relief caps (S). 3-in-1 dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-SN

    MEAN WELL XLC-60 series: constant-power LED driver - XLC-60-H-SN

    MEAN WELL XLC-60-H-SN XLC-60-H-SN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Independent type with strain-relief caps (S). Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-SN; Independent type with strain-relief caps (S). Non-dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification Control function Non-dimming Blank function. Output current is configured by NFC. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-DA2N

    MEAN WELL XLC-60 series: constant-power LED driver with DALI-2 and PUSH dimming - XLC-60-H-DA2N

    MEAN WELL XLC-60-H-DA2N XLC-60-H-DA2N is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-DA2N; Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. For the IEC 62386-101/102 timing test, use a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 seconds. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces loading to 75%; stage 2 to 50%. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-BN

    MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-BN

    MEAN WELL XLC-60-H-BN XLC-60-H-BN is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Built-in type without strain-relief caps. 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-BN; Built-in type without strain-relief caps. 3-in-1 dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-N

    MEAN WELL XLC-60 series: constant-power LED driver - XLC-60-H-N

    MEAN WELL XLC-60-H-N XLC-60-H-N is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by NFC, with a 1400 mA factory setting. Built-in type without strain-relief caps. Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF)Download MEAN WELL NFC User Manual Output specifications Parameter Specification Model and configuration XLC-60-H-N; Built-in type without strain-relief caps. Non-dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting NFC setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. 1050 mA 9–54 V recommended operating window. 1200 mA 9–50 V recommended operating window. 1300 mA 9–46 V recommended operating window. 1400 mA (default) 9–43 V recommended operating window. 1500 mA 9–40 V recommended operating window. 1600 mA 9–38 V recommended operating window. 1700 mA 9–36 V recommended operating window. N suffix: program current using an NFC-capable phone and the MEAN WELL app / PowerNFC; Android 4.1 or later, or iOS 12 or later. Read and write only with input AC power disconnected. Enable NFC and hold the phone antenna less than 5 cm from the driver’s NFC mark; read the driver, adjust its permitted current, write the setting and confirm “Success”. Read again to verify the stored value. The catalog NFC note specifies set-current versus actual-current error within 2%; the main output current tolerance remains ±5%. NFC password: the factory default is no password. A user password may contain up to 8 case-sensitive English letters or digits, without special characters, and is required for subsequent writes. The password cannot be reset by external means. The app’s “Default” function restores output current to its factory value; it is not a password reset. Control and dimming Parameter Specification Control function Non-dimming Blank function. Output current is configured by NFC. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-DA2S

    MEAN WELL XLC-60 series: constant-power LED driver with DALI-2 and PUSH dimming - XLC-60-H-DA2S

    MEAN WELL XLC-60-H-DA2S XLC-60-H-DA2S is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H-DA2S; Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. For the IEC 62386-101/102 timing test, use a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 seconds. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces loading to 75%; stage 2 to 50%. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-BS

    MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-BS

    MEAN WELL XLC-60-H-BS XLC-60-H-BS is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Independent type with strain-relief caps (S). 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H-BS; Independent type with strain-relief caps (S). 3-in-1 dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-S

    MEAN WELL XLC-60 series: constant-power LED driver - XLC-60-H-S

    MEAN WELL XLC-60-H-S XLC-60-H-S is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Independent type with strain-relief caps (S). Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H-S; Independent type with strain-relief caps (S). Non-dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification Control function Non-dimming Blank function. Output current is configured by DIP switch. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-DA2

    MEAN WELL XLC-60 series: constant-power LED driver with DALI-2 and PUSH dimming - XLC-60-H-DA2

    MEAN WELL XLC-60-H-DA2 XLC-60-H-DA2 is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H-DA2; Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. For the IEC 62386-101/102 timing test, use a DALI controller supporting the DALI power-on function; otherwise startup may exceed 0.5 seconds. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Stage 1 reduces loading to 75%; stage 2 to 50%. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H-B

    MEAN WELL XLC-60 series: constant-power LED driver with 3-in-1 dimming - XLC-60-H-B

    MEAN WELL XLC-60-H-B XLC-60-H-B is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Built-in type without strain-relief caps. 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H-B; Built-in type without strain-relief caps. 3-in-1 dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-H

    MEAN WELL XLC-60 series: constant-power LED driver - XLC-60-H

    MEAN WELL XLC-60-H XLC-60-H is a 60 W multiple-stage constant-power LED driver. Its 0.9–1.7 A output is configured by DIP switch, with a 1400 mA factory setting. Built-in type without strain-relief caps. Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-H; Built-in type without strain-relief caps. Non-dimming. Output mode Multiple-stage constant-power H type with selectable constant-current operating points. Rated output power 60 W (catalog rating) Output current 0.9–1.7 A adjustable Default current 1400 mA Constant-current region 9–54 V overall envelope. The usable LED-string voltage depends on the selected current; use the corresponding operating window below and the 60 W power limit. Open-circuit voltage 60 V; the output hiccups under no-load conditions. Current ripple <4%; measured at 50–100% of maximum voltage under rated power delivery. Current tolerance ±5% (main output specification). Current setting DIP switch setting, selected by this model suffix. Typical efficiency 90%; measured at 1050 mA / 54 V output set by DIP switch. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Output-current configuration Match the LED-string forward voltage to the selected current and the catalog I–V operating area. The rounded operating-window endpoints do not increase the 60 W product rating. Parameter Specification 900 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / OFF. 1050 mA 9–54 V recommended operating window. DIP 1/2/3: OFF / OFF / ON. 1200 mA 9–50 V recommended operating window. DIP 1/2/3: OFF / ON / OFF. 1300 mA 9–46 V recommended operating window. DIP 1/2/3: OFF / ON / ON. 1400 mA (default) 9–43 V recommended operating window. DIP 1/2/3: ON / OFF / OFF. 1500 mA 9–40 V recommended operating window. DIP 1/2/3: ON / OFF / ON. 1600 mA 9–38 V recommended operating window. DIP 1/2/3: ON / ON / OFF. 1700 mA 9–36 V recommended operating window. DIP 1/2/3: ON / ON / ON. Control and dimming Parameter Specification Control function Non-dimming Blank function. Output current is configured by DIP switch. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 100 ms at 230 VAC; 1000 ms / 100 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overtemperature protection Derates to the lowest output level. Automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-48-DA2S

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-48-DA2S

    MEAN WELL XLC-60-48-DA2S XLC-60-48-DA2S is a 60 W constant-voltage LED driver. It supplies 48 VDC at 1.25 A. Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-48-DA2S; Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 48 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 1.25 A Typical efficiency 88%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 52–63 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-24-DA2S

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-24-DA2S

    MEAN WELL XLC-60-24-DA2S XLC-60-24-DA2S is a 60 W constant-voltage LED driver. It supplies 24 VDC at 2.5 A. Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-24-DA2S; Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 24 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 2.5 A Typical efficiency 87%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 26–35 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-12-DA2S

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-12-DA2S

    MEAN WELL XLC-60-12-DA2S XLC-60-12-DA2S is a 60 W constant-voltage LED driver. It supplies 12 VDC at 5 A. Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-12-DA2S; Independent type with strain-relief caps (S). DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 12 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 5 A Typical efficiency 86%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 14–17 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-48-BS

    MEAN WELL XLC-60 series: constant-voltage LED driver with 3-in-1 dimming - XLC-60-48-BS

    MEAN WELL XLC-60-48-BS XLC-60-48-BS is a 60 W constant-voltage LED driver. It supplies 48 VDC at 1.25 A. Independent type with strain-relief caps (S). 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-48-BS; Independent type with strain-relief caps (S). 3-in-1 dimming. Output mode Fixed 48 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 1.25 A Typical efficiency 88%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Output PWM waveform 4 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 52–63 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-24-BS

    MEAN WELL XLC-60 series: constant-voltage LED driver with 3-in-1 dimming - XLC-60-24-BS

    MEAN WELL XLC-60-24-BS XLC-60-24-BS is a 60 W constant-voltage LED driver. It supplies 24 VDC at 2.5 A. Independent type with strain-relief caps (S). 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-24-BS; Independent type with strain-relief caps (S). 3-in-1 dimming. Output mode Fixed 24 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 2.5 A Typical efficiency 87%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Output PWM waveform 4 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 26–35 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-12-BS

    MEAN WELL XLC-60 series: constant-voltage LED driver with 3-in-1 dimming - XLC-60-12-BS

    MEAN WELL XLC-60-12-BS XLC-60-12-BS is a 60 W constant-voltage LED driver. It supplies 12 VDC at 5 A. Independent type with strain-relief caps (S). 3-in-1 dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-12-BS; Independent type with strain-relief caps (S). 3-in-1 dimming. Output mode Fixed 12 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 5 A Typical efficiency 86%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Dimming interface 3-in-1 control between DIM+ and DIM−: 0–10 VDC, external 10 V PWM at 300 Hz–3 kHz, or resistance 0–100 kΩ. For N synchronized drivers, the resistance scale is 100 kΩ/N. Dimming source current: 100 μA typical. Dimming limits Minimum dimming level is about 8%; output below 8% and above 0% is undefined. Dim-to-off is available with approximately 0 VDC, 0 kΩ or a 10 V PWM control signal at 0% duty cycle. Dimming connection Do not connect DIM− to output −V. Direct LED connection is recommended; the driver is not intended for use with additional drivers. Output PWM waveform 4 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 14–17 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Pin 3 DIM+; pin 4 DIM−. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-48-S

    MEAN WELL XLC-60 series: constant-voltage LED driver - XLC-60-48-S

    MEAN WELL XLC-60-48-S XLC-60-48-S is a 60 W constant-voltage LED driver. It supplies 48 VDC at 1.25 A. Independent type with strain-relief caps (S). Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-48-S; Independent type with strain-relief caps (S). Non-dimming. Output mode Fixed 48 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 1.25 A Typical efficiency 88%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Control function Non-dimming Blank function. Fixed-voltage output; no adjustable-current H function. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 52–63 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-24-S

    MEAN WELL XLC-60 series: constant-voltage LED driver - XLC-60-24-S

    MEAN WELL XLC-60-24-S XLC-60-24-S is a 60 W constant-voltage LED driver. It supplies 24 VDC at 2.5 A. Independent type with strain-relief caps (S). Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-24-S; Independent type with strain-relief caps (S). Non-dimming. Output mode Fixed 24 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 2.5 A Typical efficiency 87%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Control function Non-dimming Blank function. Fixed-voltage output; no adjustable-current H function. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 26–35 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-12-S

    MEAN WELL XLC-60 series: constant-voltage LED driver - XLC-60-12-S

    MEAN WELL XLC-60-12-S XLC-60-12-S is a 60 W constant-voltage LED driver. It supplies 12 VDC at 5 A. Independent type with strain-relief caps (S). Non-dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-12-S; Independent type with strain-relief caps (S). Non-dimming. Output mode Fixed 12 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 5 A Typical efficiency 86%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification Control function Non-dimming Blank function. Fixed-voltage output; no adjustable-current H function. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 14–17 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; the S independent control gear is Non-IC classified and is not suitable for residential installations. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 176 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 390 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60-S; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.75–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief S configuration includes strain-relief caps. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-48-DA2

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-48-DA2

    MEAN WELL XLC-60-48-DA2 XLC-60-48-DA2 is a 60 W constant-voltage LED driver. It supplies 48 VDC at 1.25 A. Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-48-DA2; Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 48 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 1.25 A Typical efficiency 88%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 52–63 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +50°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-24-DA2

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-24-DA2

    MEAN WELL XLC-60-24-DA2 XLC-60-24-DA2 is a 60 W constant-voltage LED driver. It supplies 24 VDC at 2.5 A. Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-24-DA2; Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 24 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 2.5 A Typical efficiency 87%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 26–35 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.

  • XLC-60-12-DA2

    MEAN WELL XLC-60 series: constant-voltage LED driver with DALI-2 and PUSH dimming - XLC-60-12-DA2

    MEAN WELL XLC-60-12-DA2 XLC-60-12-DA2 is a 60 W constant-voltage LED driver. It supplies 12 VDC at 5 A. Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Download MEAN WELL XLC-60 Datasheet (PDF) Output specifications Parameter Specification Model and configuration XLC-60-12-DA2; Built-in type without strain-relief caps. DALI-2 DT6 and primary-side PUSH dimming. Output mode Fixed 12 VDC constant-voltage output. Rated output power 60 W (catalog rating) Output current 5 A Typical efficiency 86%. Measurement basis Unless stated otherwise: 230 VAC input, rated current and 25°C ambient. Control and dimming Parameter Specification DALI-2 interface DALI-2 DT6; IEC62386-101, -102 and -207. Minimum dimming level 0.1%; dimming range to 100% with off control. Use TB1 DA+/PUSH and DA−/N for the DALI bus as shown in the DALI wiring diagram. Primary-side PUSH wiring For the separate PUSH wiring arrangement: connect the push button between AC/L and DA+/PUSH; connect DA−/N to AC/N. Follow the correct DALI or PUSH diagram for the installation; do not apply mains to a DALI bus. PUSH operation Factory dimming level 100%. A press shorter than 0.05 s causes no change. Short press 0.1–1 s: on/off; double click twice within 1.5 s: 100%; long press 1.5–10 s: alternates dim-up and dim-down direction. PUSH limits At most 10 drivers on one common push button; maximum cable length from the button to the last driver is 20 m. Output PWM waveform 3.2 kHz fixed typical output PWM frequency. Brightness is adjusted by varying output duty cycle; this output waveform is distinct from an external PWM control input. Input and protection Parameter Specification AC and DC input 100–305 VAC; 155–400 VDC. AC frequency 47–63 Hz. Verify the manufacturer’s DC wiring instructions before connecting a DC source. Power factor Active PFC. Full-load PF ≥0.95 at 115/230 VAC and ≥0.9 at 277 VAC. Total harmonic distortion <20% at load ≥60% / 230 VAC or ≥75% / 277 VAC; <10% at 100% load / 230 VAC. AC input current 0.75 A / 115 VAC; 0.35 A / 230 VAC; 0.3 A / 277 VAC. Cold-start inrush 15 A; width 310 μs measured at 50% Ipeak, 230 VAC; per NEMA 410. 16 A circuit breaker loading 25 / 36 units on type B / type C respectively at 230 VAC, as catalog reference conditions. Verify the actual breaker and installation. Leakage current <0.75 mA at 277 VAC. Setup and rise time 800 ms / 180 ms at 230 VAC; 1000 ms / 180 ms at 115 VAC. Setup time is measured at the first cold start; switching the driver ON/OFF may increase setup time. Standby consumption <0.5 W at 230 VAC with dimming off; specified for standard B/DA2 versions. Short circuit Hiccup mode; automatically recovers after the fault is removed. Overload protection 105–200% of rated output power; hiccup mode with automatic recovery after fault removal. Overvoltage protection 14–17 V; output shuts down; reapply power to recover. Overtemperature protection Output shuts down; automatically recovers after the fault is removed. Thermal and environmental limits Parameter Specification Cooling and ambient limits Free-air convection; horizontal mounting for the published load curves. At 110 VAC: 100% load from −25°C to +40°C ambient. At 230 VAC: 100% load from −25°C to +45°C ambient. The corresponding curves stop at these limits; do not infer operation beyond them. Case temperature Tcase −25 to +90°C; maximum +90°C at the designated tc point. This case-temperature limit is not an ambient-temperature rating. Input/load derating At 60 Hz: 80% load at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Apply the temperature and voltage limits together. Altitude derating Above 2000 m, reduce permitted ambient temperature by 3.5°C per additional 1000 m for this fanless driver. Humidity and storage Operating: 20–90% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X/Y/Z axis. Lifetime and warranty 50,000 hours typical life when Tcase at the tc point is about 75°C or lower. Manufacturer catalog states a 5-year warranty, subject to its terms; life expectancy is not a warranty duration. MTBF 4130.5 / 317.7 thousand hours minimum: Telcordia SR-332 / MIL-HDBK-217F at 25°C, respectively. Safety and compliance conditions Parameter Specification Construction Class II plastic housing with active PFC; catalog identifies UL8750 Class 2 / Class P and SELV. Safety standards ENEC BS EN/EN61347-1 and BS EN/EN61347-2-13 (EL), Appendix J; BS EN/EN62384; BIS IS15885 Part 2/Sec 13; GB/T19510.1 and GB/T19510.213; EAC TP TC 004; UL8750 Class P; CSA C22.2 No. 250.13-12. AS/NZS61347-1 and -2-13 are design references. Emergency-lighting condition The EL / Appendix J emergency-installation condition is 176–280 VDC input; this is distinct from the normal DC input range. RCM and regional marks Catalog RCM note: voluntary RCM; relevant IEC or AS/NZS standards with AS/NZS4417.1. Products sourced from China and some India models may lack the BIS logo; confirm the actual certificate and region. Insulation Input–output withstand 3.75 kVAC; insulation resistance >100 MΩ at 500 VDC, 25°C / 70% RH. EMC emissions BS EN/EN55015 (CISPR15), GB/T17743; BS EN/EN61000-3-2 and GB17625.1 Class C at load ≥60%; voltage flicker BS EN/EN61000-3-3. EMC immunity BS EN/EN61547; EN61000-4-2: level 3 / 8 kV air and level 2 / 4 kV contact; -4-3, -4-4, -4-6 and -4-8: level 2; -4-5: level 3, 1 kV line-to-line; -4-11: 70% residual voltage for 10 periods and 0% for 0.5 periods. Light flicker PstLM ≤1 and SVM ≤0.4, measured at full load using the light source supplied by MEAN WELL. ErP and final equipment For the stated ErP application, install behind a switch; do not permanently connect the driver to the mains. The final equipment manufacturer must requalify EMC for the complete installation. Mechanical and installation details Parameter Specification Dimensions 136 × 45 × 32 mm (L × W × H); drawing tolerance ±1 mm. Unit weight 320 g, catalog individual-unit PACKING value. Mounting and case Case XLC-60; two Ø3.6 mm mounting holes, 128 mm longitudinal spacing. Follow the full drawing for mounting orientation and clearances. Terminal assignment TB1: pin 1 AC/N; pin 2 AC/L. Pin 3 DA+/PUSH; pin 4 DA−/N. TB2: pin 1 +V; pin 2 −V. Wiring size TB1 input: 0.5–1.5 mm²; TB2 output: 0.5–1.5 mm². Strip 8–9 mm; follow the terminal drawing. Strain relief Built-in configuration has no strain-relief caps. The catalog lists an optional strain-relief cap set with printed order reference 1**3XLC-SET; one bag contains 50 pieces, two pieces per set. Confirm the complete ordering reference and fit with MEAN WELL; the printed asterisks must not be expanded by guesswork. Use the drawing for this casing and control option. Match the LED load to the specified output, observe terminal polarity and conductor size, and provide the free-air-convection conditions used by the load curves. Check the tc point in the completed installation and requalify final-equipment EMC. Catalog reference: XLC-60, pages 53–63 of the combined XLN/XLC PDF. Use the exact model, suffix and applicable wiring drawing when designing the installation.


You have seen 24 out of 84 products