The GEM series represents MEAN WELL's highly reliable, eco-friendly wall-mounted medical power adapters. Designed with an innovative interchangeable AC plug system, these adapters are the ultimate solution for portable medical devices intended for the global market.

  • Medical Grade Certified: Complies with international medical safety regulations (2xMOPP) with extremely low leakage current (<100μA), making it suitable for BF (Body Floating) patient contact applications.
  • Global Adaptability: Features a modular AC plug design. Manufacturers can ship a single power supply body and simply attach the appropriate regional plug, vastly simplifying global inventory.
  • Class II Power: Designed without an earth ground pin, utilizing double insulation to ensure maximum patient and operator safety.
  • Compact & Portable: The space-saving wall-mount design does not block adjacent power outlets, making it highly convenient for home healthcare and mobile clinical use.

Technical Highlights

  • Ultra-Low Power Consumption: Features an exceptionally low no-load power consumption (typically <0.075W to <0.15W), meeting stringent EISA 2007/DoE and EU ErP Level VI energy efficiency standards (GEM06I meets Level V).
  • Wide Operating Temperature: Capable of reliable operation in varied environments ranging from -20°C to +70°C.
  • Comprehensive Protections: Built-in safeguards against short circuits, overloads, and over-voltage scenarios ensure continuous, risk-free operation.
  • Durable Enclosure: Housed in a fully enclosed, flame-retardant plastic case (IP21/IP22 rated) to protect against dust and minor moisture ingress.
  • Warranty: Backed by a standard 3-year manufacturer warranty.

Power Range & Ideal Applications

The GEM series scales across multiple wattages to support a wide variety of medical and home healthcare electronics.

Series Models Standard Output Voltages Target Applications
GEM06I, GEM12I, GEM18I (6W - 18W) 5V, 7.5V, 9V, 12V, 15V, 18V, 24V, 48V Blood glucose meters, blood pressure monitors, nebulizers, inhalers, and small portable diagnostic devices.
GEM30I, GEM40I, GEM60I (30W - 60W) Sleep apnea devices (CPAP), medical computer tablets, larger portable oxygen concentrators, and clinical diagnostic carts.

Interchangeable AC Plugs (Accessories)

The core advantage of the GEM series is its interchangeable AC plug interface. These modular plugs slide and lock securely into the main adapter body, transforming it instantly for any regional power grid. Plugs are ordered separately or as a complete mixed set.

Plug Model Region / Style Description
AC PLUG-US2 North America / USA Standard 2-pin American plug. Fits standard NEMA 1-15 wall outlets.
AC PLUG-EU2 Europe Standard 2-pin European (Europlug) style. Fits standard CEE 7/16 sockets.
AC PLUG-UK2 United Kingdom Standard UK 3-pin style (utilizing only 2 pins for Class II power transmission). Fits BS 1363 sockets.
AC PLUG-AU2 Australia / New Zealand Standard 2-pin Australian angled plug. Fits AS/NZS 3112 sockets.
AC PLUG-MIX2 Global Kit A complete combination package containing all four regional plugs (US, EU, UK, AU) for ultimate travel or global deployment flexibility.
Logistics Advantage: Purchasing the main adapter body and the required regional plugs as separate line items allows medical device manufacturers to dynamically allocate their power supply inventory based on real-time global shipping destinations.
  • MEAN WELL GEM series: Interchangeable AC Plug Set - AC PLUG-MIX2

    MEAN WELL GEM series: Interchangeable AC Plug Set - AC PLUG-MIX2

    MEAN WELL AC PLUG-MIX2 is a four-region interchangeable AC plug set for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I adapters. It provides Australian, UK, European and US plug types. It is ordered separately from the adapter main body. Product Datasheet Download MEAN WELL GEM Datasheet (PDF) The GEM section is on PDF pages 2, 7, 12, 15, 18, 21. Refer to the complete mechanical drawings and notes when planning installation. Accessory Identification Complete order model AC PLUG-MIX2. Accessory type Four-region interchangeable AC plug set. Compatible adapter families GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I. Order arrangement The interchangeable AC plug accessory is ordered separately from the GEM adapter main body. The power adapter is not included. Regional Configuration and Contents Regional plug format Australian, UK, European and US types. Contents Four plug types: AC PLUG-AU2, AC PLUG-UK2, AC PLUG-EU2, AC PLUG-US2. Select the plug form for the destination and the exact compatible GEM adapter. Use the corresponding GEM-series AC plug code; other plug families are not interchangeable merely because the regional pin shape appears similar. Compatibility and Use Applicable equipment Use with the compatible MEAN WELL GEM adapter families listed above. Supply function This is an interchangeable mains-plug accessory, not a power-conversion unit or a DC output connector. Adapter electrical limits The selected adapter main body determines the input range, DC output voltage, current, power and operating limits. A plug change does not increase those ratings. The compatible GEM adapters use Class II construction without functional ground. Plug shape does not establish an earth-connection function. The accessory itself is not assigned the adapter body’s output ratings, medical isolation approval or ingress-protection rating. Catalogue Reference Ordering evidence GEM-series combined PDF, pages 2, 7, 12, 15, 18 and 21. These ordering tables show the corresponding AU2, UK2, EU2, US2 and MIX2 plug types. The adapter main body and matching interchangeable AC plug are separate order items. Use the linked catalogue to match the adapter series and plug-selection drawing.

  • MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-US2

    MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-US2

    MEAN WELL AC PLUG-US2 is a US interchangeable AC plug for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I adapters. It is ordered separately from the adapter main body. Product Datasheet Download MEAN WELL GEM Datasheet (PDF) The GEM section is on PDF pages 2, 7, 12, 15, 18, 21. Refer to the complete mechanical drawings and notes when planning installation. Accessory Identification Complete order model AC PLUG-US2. Accessory type US interchangeable AC plug. Compatible adapter families GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I. Order arrangement The interchangeable AC plug accessory is ordered separately from the GEM adapter main body. The power adapter is not included. Regional Configuration and Contents Regional plug format US type. Contents One US interchangeable AC plug head. Select the plug form for the destination and the exact compatible GEM adapter. Use the corresponding GEM-series AC plug code; other plug families are not interchangeable merely because the regional pin shape appears similar. Compatibility and Use Applicable equipment Use with the compatible MEAN WELL GEM adapter families listed above. Supply function This is an interchangeable mains-plug accessory, not a power-conversion unit or a DC output connector. Adapter electrical limits The selected adapter main body determines the input range, DC output voltage, current, power and operating limits. A plug change does not increase those ratings. The compatible GEM adapters use Class II construction without functional ground. Plug shape does not establish an earth-connection function. The accessory itself is not assigned the adapter body’s output ratings, medical isolation approval or ingress-protection rating. Catalogue Reference Ordering evidence GEM-series combined PDF, pages 2, 7, 12, 15, 18 and 21. These ordering tables show the corresponding AU2, UK2, EU2, US2 and MIX2 plug types. The adapter main body and matching interchangeable AC plug are separate order items. Use the linked catalogue to match the adapter series and plug-selection drawing.

  • MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-EU2

    MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-EU2

    MEAN WELL AC PLUG-EU2 is a European interchangeable AC plug for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I adapters. It is ordered separately from the adapter main body. Product Datasheet Download MEAN WELL GEM Datasheet (PDF) The GEM section is on PDF pages 2, 7, 12, 15, 18, 21. Refer to the complete mechanical drawings and notes when planning installation. Accessory Identification Complete order model AC PLUG-EU2. Accessory type European interchangeable AC plug. Compatible adapter families GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I. Order arrangement The interchangeable AC plug accessory is ordered separately from the GEM adapter main body. The power adapter is not included. Regional Configuration and Contents Regional plug format European type. Contents One European interchangeable AC plug head. Select the plug form for the destination and the exact compatible GEM adapter. Use the corresponding GEM-series AC plug code; other plug families are not interchangeable merely because the regional pin shape appears similar. Compatibility and Use Applicable equipment Use with the compatible MEAN WELL GEM adapter families listed above. Supply function This is an interchangeable mains-plug accessory, not a power-conversion unit or a DC output connector. Adapter electrical limits The selected adapter main body determines the input range, DC output voltage, current, power and operating limits. A plug change does not increase those ratings. The compatible GEM adapters use Class II construction without functional ground. Plug shape does not establish an earth-connection function. The accessory itself is not assigned the adapter body’s output ratings, medical isolation approval or ingress-protection rating. Catalogue Reference Ordering evidence GEM-series combined PDF, pages 2, 7, 12, 15, 18 and 21. These ordering tables show the corresponding AU2, UK2, EU2, US2 and MIX2 plug types. The adapter main body and matching interchangeable AC plug are separate order items. Use the linked catalogue to match the adapter series and plug-selection drawing.

  • MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-UK2

    MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-UK2

    MEAN WELL AC PLUG-UK2 is a UK interchangeable AC plug for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I adapters. It is ordered separately from the adapter main body. Product Datasheet Download MEAN WELL GEM Datasheet (PDF) The GEM section is on PDF pages 2, 7, 12, 15, 18, 21. Refer to the complete mechanical drawings and notes when planning installation. Accessory Identification Complete order model AC PLUG-UK2. Accessory type UK interchangeable AC plug. Compatible adapter families GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I. Order arrangement The interchangeable AC plug accessory is ordered separately from the GEM adapter main body. The power adapter is not included. Regional Configuration and Contents Regional plug format UK type. Contents One UK interchangeable AC plug head. Select the plug form for the destination and the exact compatible GEM adapter. Use the corresponding GEM-series AC plug code; other plug families are not interchangeable merely because the regional pin shape appears similar. Compatibility and Use Applicable equipment Use with the compatible MEAN WELL GEM adapter families listed above. Supply function This is an interchangeable mains-plug accessory, not a power-conversion unit or a DC output connector. Adapter electrical limits The selected adapter main body determines the input range, DC output voltage, current, power and operating limits. A plug change does not increase those ratings. The compatible GEM adapters use Class II construction without functional ground. Plug shape does not establish an earth-connection function. The accessory itself is not assigned the adapter body’s output ratings, medical isolation approval or ingress-protection rating. Catalogue Reference Ordering evidence GEM-series combined PDF, pages 2, 7, 12, 15, 18 and 21. These ordering tables show the corresponding AU2, UK2, EU2, US2 and MIX2 plug types. The adapter main body and matching interchangeable AC plug are separate order items. Use the linked catalogue to match the adapter series and plug-selection drawing.

  • MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-AU2

    MEAN WELL GEM series: Interchangeable AC Plug - AC PLUG-AU2

    MEAN WELL AC PLUG-AU2 is an Australian interchangeable AC plug for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I adapters. It is ordered separately from the adapter main body. Product Datasheet Download MEAN WELL GEM Datasheet (PDF) The GEM section is on PDF pages 2, 7, 12, 15, 18, 21. Refer to the complete mechanical drawings and notes when planning installation. Accessory Identification Complete order model AC PLUG-AU2. Accessory type Australian interchangeable AC plug. Compatible adapter families GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I. Order arrangement The interchangeable AC plug accessory is ordered separately from the GEM adapter main body. The power adapter is not included. Regional Configuration and Contents Regional plug format Australian type. Contents One Australian interchangeable AC plug head. Select the plug form for the destination and the exact compatible GEM adapter. Use the corresponding GEM-series AC plug code; other plug families are not interchangeable merely because the regional pin shape appears similar. Compatibility and Use Applicable equipment Use with the compatible MEAN WELL GEM adapter families listed above. Supply function This is an interchangeable mains-plug accessory, not a power-conversion unit or a DC output connector. Adapter electrical limits The selected adapter main body determines the input range, DC output voltage, current, power and operating limits. A plug change does not increase those ratings. The compatible GEM adapters use Class II construction without functional ground. Plug shape does not establish an earth-connection function. The accessory itself is not assigned the adapter body’s output ratings, medical isolation approval or ingress-protection rating. Catalogue Reference Ordering evidence GEM-series combined PDF, pages 2, 7, 12, 15, 18 and 21. These ordering tables show the corresponding AU2, UK2, EU2, US2 and MIX2 plug types. The adapter main body and matching interchangeable AC plug are separate order items. Use the linked catalogue to match the adapter series and plug-selection drawing.

  • GEM60I48-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I48-P1J

    MEAN WELL GEM60I48-P1J is a Class II medical AC/DC power adapter providing 48 VDC at 1.25 A, with a 60 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I48-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 48 identifies 48 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 48 VDC. Rated current / load range 1.25 A rated; 0–1.25 A operating range. Rated power, maximum 60 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 150 mVp-p under the measurement conditions below. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 90% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level VI for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 18 AWG; 1500 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I24-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I24-P1J

    MEAN WELL GEM60I24-P1J is a Class II medical AC/DC power adapter providing 24 VDC at 2.5 A, with a 60 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I24-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 24 identifies 24 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 24 VDC. Rated current / load range 2.5 A rated; 0–2.5 A operating range. Rated power, maximum 60 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 120 mVp-p under the measurement conditions below. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level VI for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 18 AWG; 1500 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I18-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I18-P1J

    MEAN WELL GEM60I18-P1J is a Class II medical AC/DC power adapter providing 18 VDC at 3.33 A, with a 60 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I18-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 18 identifies 18 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 18 VDC. Rated current / load range 3.33 A rated; 0–3.33 A operating range. Rated power, maximum 60 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 120 mVp-p under the measurement conditions below. Voltage tolerance ±3%. Line regulation ±1%. Load regulation ±2%. Efficiency, typical 88% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level VI for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I15-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I15-P1J

    MEAN WELL GEM60I15-P1J is a Class II medical AC/DC power adapter providing 15 VDC at 4 A, with a 60 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I15-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 15 identifies 15 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 15 VDC. Rated current / load range 4 A rated; 0–4 A operating range. Rated power, maximum 60 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 120 mVp-p under the measurement conditions below. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level VI for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I12-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I12-P1J

    MEAN WELL GEM60I12-P1J is a Class II medical AC/DC power adapter providing 12 VDC at 4.5 A, with a 54 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I12-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 12 identifies 12 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 12 VDC. Rated current / load range 4.5 A rated; 0–4.5 A operating range. Rated power, maximum 54 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 100 mVp-p under the measurement conditions below. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±3%. Efficiency, typical 88% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level VI for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I09-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I09-P1J

    MEAN WELL GEM60I09-P1J is a Class II medical AC/DC power adapter providing 9 VDC at 5.5 A, with a 50 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I09-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 09 identifies 9 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 9 VDC. Rated current / load range 5.5 A rated; 0–5.5 A operating range. Rated power, maximum 50 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 100 mVp-p under the measurement conditions below. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 87% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level V for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry the full 5.5 A rated output of this model: limit the load through those adapters to 5 A or choose a connection with a suitable higher current rating. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I07-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I07-P1J

    MEAN WELL GEM60I07-P1J is a Class II medical AC/DC power adapter providing 7.5 VDC at 6 A, with a 45 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I07-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 07 identifies 7.5 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 7.5 VDC. Rated current / load range 6 A rated; 0–6 A operating range. Rated power, maximum 45 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 100 mVp-p under the measurement conditions below. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 85% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level V for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry the full 6 A rated output of this model: limit the load through those adapters to 5 A or choose a connection with a suitable higher current rating. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM60I05-P1J

    MEAN WELL GEM60I series: Interchangeable-Plug Medical AC/DC Power Adapter - GEM60I05-P1J

    MEAN WELL GEM60I05-P1J is a Class II medical AC/DC power adapter providing 5 VDC at 6 A, with a 30 W maximum rated output and a center-positive P1J DC plug. It provides 2 × MOPP primary-to-secondary isolation and is suitable for BF applications within an appropriately evaluated medical system. The interchangeable AC plug is ordered separately. Product Datasheet Download MEAN WELL GEM60I Datasheet (PDF) The GEM60I section is on PDF pages 20, 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model and Configuration Complete order model GEM60I05-P1J. Series and voltage code GEM60I interchangeable-plug medical AC/DC adapter; code 05 identifies 5 VDC. Construction Class II construction without functional ground, in a fully enclosed 94V-0 flame-retardant plastic case. Standard DC plug P1J tuning-fork plug; 5.5 mm outside diameter, 2.1 mm inside diameter, 11 ± 0.5 mm length. Center positive; outer sleeve negative. Mains plug The adapter main body and interchangeable AC plug are ordered separately. A compatible AC plug is required for use. Output Ratings DC output voltage 5 VDC. Rated current / load range 6 A rated; 0–6 A operating range. Rated power, maximum 30 W; observe both the current limit and rated power, together with applicable derating. Ripple and noise, maximum 100 mVp-p under the measurement conditions below. Voltage tolerance ±5%. Line regulation ±1%. Load regulation ±5%. Efficiency, typical 80% under the general test conditions below. Input and Timing Input range 80–264 VAC or 113–370 VDC; AC frequency 47–63 Hz. AC input current 1.5 A at 115 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 50 A at 115 VAC; 100 A at 230 VAC. Touch current Less than 100 µA at 264 VAC. Set-up / rise / hold-up time 500 ms / 30 ms / 10 ms at 115 VAC and 230 VAC, full load. No-load power Less than 0.15 W. Energy efficiency Level V for this voltage model. The GEM60I 5–9 V models are Level V; 12–48 V models are Level VI. Protection Short circuit / overload Overload protection at 105–160% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage 110–140% of rated output voltage; Zener-diode clamp, output short. Medical Safety and Application Patient-protection isolation Primary-to-secondary isolation: 2 × MOPP (means of patient protection). Application suitability Suitable for BF-type medical applications, subject to evaluation in the final equipment. Listed safety approvals TUV BS EN/EN60601-1 and BS EN/EN60601-1-11; ANSI/AAMI ES60601-1 and ES60601-1-11 (3.1 version); CAN/CSA-C22.2 No. 60601-1, 3rd edition; EAC TP TC 004. Ingress protection IP22, as specified for the GEM60I adapter. Dielectric withstand Input to output: 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. The adapter approvals and isolation rating do not certify the complete medical system or its applied parts. Confirm the equipment-level safety, leakage-current and EMC requirements for the intended application. Operating Conditions and Derating Operating temperature −30 to +70°C; apply the ambient-temperature derating curve. Temperature curve 100% load from −30 to +40°C; the marked points are 70% at +50°C and 50% at +70°C. Follow the plotted curve between these points. Input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% load from 115 to 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage temperature / humidity −30 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each on X, Y and Z axes. Observe both input-voltage and ambient-temperature limits. The maximum operating temperature does not imply full rated output. Mechanical Details and Cable Main-body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Allow clearance for the selected AC plug and DC cable. DC cable UL2468 16 AWG; 1000 +150/−0 mm for this output-voltage version. Catalogue unit weight 200 g, catalogue packing reference per unit; not a measured net or shipping weight. Use the mechanical drawing on PDF page 22 for the body and cable arrangement. Check the equipment socket dimensions and polarity before connection. Separately Ordered AC Plugs Australian type AC PLUG-AU2. UK type AC PLUG-UK2. European type AC PLUG-EU2. US type AC PLUG-US2. Four-region set AC PLUG-MIX2: Australian AU2, UK2, EU2 and US2 plug types. These AC plug heads are listed for GEM06I / GEM12I / GEM18I / GEM30I / GEM40I / GEM60I and are ordered separately from the main body. The AC plug head and optional DC output connector are different parts. Optional DC Connectors and Quick Adapters Tuning-fork plugs P1I: 5.5 / 2.1 / 9.5; P1L: 5.5 / 2.5 / 9.5; P1M: 5.5 / 2.5 / 11; P1IR: 5.5 / 2.1 / 9.5; P1JR: 5.5 / 2.1 / 11; P1LR: 5.5 / 2.5 / 9.5; P1MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. Quick adapters: 7.5 A maximum. Barrel plugs P2I: 5.5 / 2.1 / 9.5; P2J: 5.5 / 2.1 / 11; P2L: 5.5 / 2.5 / 9.5; P2M: 5.5 / 2.5 / 11; P2IR: 5.5 / 2.1 / 9.5; P2JR: 5.5 / 2.1 / 11; P2LR: 5.5 / 2.5 / 9.5; P2MR: 5.5 / 2.5 / 11 mm (outside diameter / inside diameter / length). Codes ending in R are right-angled; the others are straight. No quick adapter is listed for these codes. Locking plugs P2S (S761K): 5.53 / 2.03 / 12.06; P2K (761K): 5.53 / 2.54 / 12.06; P2C (S760K): 5.53 / 2.03 / 9.52; P2D (760K): 5.53 / 2.54 / 9.52 mm (outside diameter / inside diameter / length). SWITCHCRAFT original or equivalent. No quick adapter is listed. Minimum-pin plugs P3A: 2.35 / 0.7 / 11; P3B: 4.0 / 1.7 / 11; P3C: 4.75 / 1.7 / 11 mm (outside diameter / inside diameter / length). EIAJ equivalent; quick adapters: 5 A maximum. P3A / P3B / P3C quick adapters cannot carry the full 6 A rated output of this model: limit the load through those adapters to 5 A or choose a connection with a suitable higher current rating. Center-pin plugs P4A: 5.5 / 3.4 / 11; P4B: 6.5 / 4.4 / 11; P4C: 7.4 / 5.1 / 11 mm (outside diameter / inside diameter / length). Center-pin diameters: P4A 1.0 mm, P4B 1.4 mm, P4C 0.6 mm. Quick adapters: 7.5 A maximum. R6B, locking 3-pin male KYCON KPPX-3P equivalent; pins 1 and 3 = +Vo, pin 2 = −Vo. Quick adapter: 7.5 A maximum. R7B, locking 4-pin male KYCON KPPX-4P equivalent; pins 1 and 4 = +Vo, pins 2 and 3 = −Vo. Quick adapter: 7.5 A maximum. Stripped and tinned leads Lead 1, ribbed or white = +Vo; lead 2, lettered or black = −Vo. Illustrated lengths: L = 25 mm, L1 = 10 mm; other lengths can be requested. No quick adapter is listed. The listed order model has the standard P1J DC plug. Alternative connectors may be factory-customized subject to a minimum order quantity, or selected as separately purchased quick adapters where listed; quick adapters have no minimum order quantity. They are not automatically included. A connector change does not increase the power supply output. Use the lowest applicable adapter, cable and connector current limit, and confirm mating dimensions and polarity before connection. EMC Conducted / radiated emissions BS EN/EN55011 (CISPR11), FCC Part 18: Class B. Harmonics / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3. Immunity framework BS EN/EN55011 and BS EN/EN60601-1-2. ESD immunity BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9: 9–28 V/m at 385 MHz–6 GHz. EFT bursts BS EN/EN61000-4-4: Level 3, 2 kV line-to-line and 1 kV on interconnecting lines, at 100 kHz repetition rate. Surge immunity BS EN/EN61000-4-5: Level 3, 2 kV line-to-line. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Magnetic-field immunity BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. Final equipment EMC performance depends on the complete installation and must be checked with the connected equipment. Measurement Conditions and Reliability General test conditions Unless otherwise specified: 230 VAC input, rated load, 25°C and 70% RH. DC voltage set point Measured at the output plug at 50% load. Ripple/noise measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. MTBF, minimum 400 thousand hours, MIL-HDBK-217F at 25°C. Catalogue life condition 3 years at 100% load, 40°C and 8 hours/day. Manufacturer warranty 3 years, subject to manufacturer warranty terms. Catalogue revision 2021-12-08; combined PDF pages 20–24. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high input voltage at rated load; load regulation is measured from 10% to 100% rated load. Applications and Selection Application examples include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Select the correct output voltage, current capacity, polarity and regional AC plug for the equipment.

    $101.53

  • GEM40I48-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I48-P1J

    MEAN WELL GEM40I48-P1J delivers 48 V at a rated 0.83 A, with a catalogue-rated maximum output of 40 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I48-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 48: 48 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I48 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 48 V Rated current / current range 0.83 A rated; 0 to 0.83 A range. Catalogue-rated maximum power 40 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 200 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 90.5% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I24-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I24-P1J

    MEAN WELL GEM40I24-P1J delivers 24 V at a rated 1.66 A, with a catalogue-rated maximum output of 40 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I24-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 24: 24 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I24 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 24 V Rated current / current range 1.66 A rated; 0 to 1.66 A range. Catalogue-rated maximum power 40 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 120 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 89% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I18-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I18-P1J

    MEAN WELL GEM40I18-P1J delivers 18 V at a rated 2.22 A, with a catalogue-rated maximum output of 40 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I18-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 18: 18 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I18 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 18 V Rated current / current range 2.22 A rated; 0 to 2.22 A range. Catalogue-rated maximum power 40 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 120 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 88% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I15-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I15-P1J

    MEAN WELL GEM40I15-P1J delivers 15 V at a rated 2.66 A, with a catalogue-rated maximum output of 40 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I15-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 15: 15 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I15 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 15 V Rated current / current range 2.66 A rated; 0 to 2.66 A range. Catalogue-rated maximum power 40 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 120 mVp-p Voltage tolerance ±3.0% Line / load regulation ±1.0% / ±3.0% Typical efficiency 88% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 16 AWG, 1000 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I12-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I12-P1J

    MEAN WELL GEM40I12-P1J delivers 12 V at a rated 3.33 A, with a catalogue-rated maximum output of 40 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I12-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 12: 12 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I12 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 12 V Rated current / current range 3.33 A rated; 0 to 3.33 A range. Catalogue-rated maximum power 40 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±3.0% Line / load regulation ±1.0% / ±3.0% Typical efficiency 88% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 16 AWG, 1000 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I09-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I09-P1J

    MEAN WELL GEM40I09-P1J delivers 9 V at a rated 4 A, with a catalogue-rated maximum output of 36 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I09-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 09: 9 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I09 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 9 V Rated current / current range 4 A rated; 0 to 4 A range. Catalogue-rated maximum power 36 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line / load regulation ±1.0% / ±5.0% Typical efficiency 87% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 16 AWG, 1000 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM40I05-P1J

    MEAN WELL GEM40I series: GEM40I Medical AC/DC Adapter - GEM40I05-P1J

    MEAN WELL GEM40I05-P1J delivers 5 V at a rated 5 A, with a catalogue-rated maximum output of 25 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM40I Datasheet (PDF) The GEM40I section is on PDF pages 17, 18, 19. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM40I05-P1J Series and product GEM40I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 40: nominal family class; I: interchangeable AC plug; 05: 5 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM40I05 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 5 V Rated current / current range 5 A rated; 0 to 5 A range. Catalogue-rated maximum power 25 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±5.0% Line / load regulation ±1.0% / ±5.0% Typical efficiency 84% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 30 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 105–160% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -25 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL1571, 14 AWG, 1000 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 200 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-11

  • GEM30I48-P1J

    MEAN WELL GEM30I series: GEM30I Medical AC/DC Adapter - GEM30I48-P1J

    MEAN WELL GEM30I48-P1J delivers 48 V at a rated 0.625 A, with a catalogue-rated maximum output of 30 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM30I Datasheet (PDF) The GEM30I section is on PDF pages 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM30I48-P1J Series and product GEM30I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 30: nominal family class; I: interchangeable AC plug; 48: 48 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM30I48 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 48 V Rated current / current range 0.625 A rated; 0 to 0.625 A range. Catalogue-rated maximum power 30 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 90% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 100 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 120–200% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -20 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 24 AWG, 1800 mm (+50/-0 mm length tolerance). Single-unit catalogue weight 192 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-14

  • GEM30I24-P1J

    MEAN WELL GEM30I series: GEM30I Medical AC/DC Adapter - GEM30I24-P1J

    MEAN WELL GEM30I24-P1J delivers 24 V at a rated 1.25 A, with a catalogue-rated maximum output of 30 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM30I Datasheet (PDF) The GEM30I section is on PDF pages 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM30I24-P1J Series and product GEM30I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 30: nominal family class; I: interchangeable AC plug; 24: 24 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM30I24 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 24 V Rated current / current range 1.25 A rated; 0 to 1.25 A range. Catalogue-rated maximum power 30 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 88.5% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 100 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 120–200% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -20 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 192 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-14

  • GEM30I18-P1J

    MEAN WELL GEM30I series: GEM30I Medical AC/DC Adapter - GEM30I18-P1J

    MEAN WELL GEM30I18-P1J delivers 18 V at a rated 1.66 A, with a catalogue-rated maximum output of 30 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM30I Datasheet (PDF) The GEM30I section is on PDF pages 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM30I18-P1J Series and product GEM30I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 30: nominal family class; I: interchangeable AC plug; 18: 18 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM30I18 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 18 V Rated current / current range 1.66 A rated; 0 to 1.66 A range. Catalogue-rated maximum power 30 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line / load regulation ±1.0% / ±2.0% Typical efficiency 88% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 100 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 120–200% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -20 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 192 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-14

  • GEM30I15-P1J

    MEAN WELL GEM30I series: GEM30I Medical AC/DC Adapter - GEM30I15-P1J

    MEAN WELL GEM30I15-P1J delivers 15 V at a rated 2 A, with a catalogue-rated maximum output of 30 W. This Class II medical adapter has an interchangeable AC plug interface and a centre-positive P1J DC lead; the AC plug kit is sold separately. Product Datasheet Download MEAN WELL GEM30I Datasheet (PDF) The GEM30I section is on PDF pages 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and configuration Full ordering code GEM30I15-P1J Series and product GEM30I single-output medical AC/DC adapter with interchangeable AC plugs. Code meaning GEM: medical adapter series; 30: nominal family class; I: interchangeable AC plug; 15: 15 V output; P1J: standard centre-positive tuning-fork DC plug. Safety model GEM30I15 Supply configuration P1J DC output lead is the standard configuration. The interchangeable AC plug kit is sold separately. Output specifications DC output voltage 15 V Rated current / current range 2 A rated; 0 to 2 A range. Catalogue-rated maximum power 30 W. Select the load within both the rated current and rated power limits. Ripple and noise, maximum 100 mVp-p Voltage tolerance ±3.0% Line / load regulation ±1.0% / ±3.0% Typical efficiency 87% No-load consumption / efficiency level <0.1 W; Level VI. EISA 2007 / DoE and EU ErP. Input and start-up Input range / frequency 80–264 VAC or 113–370 VDC; 47–63 Hz. AC input current 1 A at 115 VAC; 0.6 A at 230 VAC. Maximum inrush current 30 A at 115 VAC; 65 A at 230 VAC. Set-up / rise / hold-up time 500 / 100 / 16 ms at full load, at both 115 VAC and 230 VAC. Input class Class II, without an earth pin. Touch current <100 µA at 264 VAC. Protection Short circuit and overload Short-circuit protection is listed. Overload: 120–200% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage 110–140% of rated output voltage; zener-diode clamping with the output-short protection mode stated in the datasheet. Temperature and input derating Working ambient range -25 to +70°C, subject to the load curve. Thermal curve 100% load from -25 to +40°C; reduce along the plotted line to 50% at +70°C. Low-input-voltage curve 80% load at 80 VAC, increasing to 100% at 115 VAC; 100% from 115 to 264 VAC. Working humidity 20–90% RH, non-condensing. Storage -20 to +85°C; 10–95% RH. Temperature coefficient ±0.03%/°C from 0 to 40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Apply both temperature and input-voltage derating when selecting the permitted load. The wider working range does not mean full-load operation at every temperature. Medical safety and system integration Isolation / patient environment 2 × MOPP between primary and secondary. Suitable for BF applications with appropriate system consideration. Safety approvals in this catalogue ANSI/AAMI ES60601-1 / 60601-1-11 and TUV EN60601-1 / 60601-1-11 approved. Input-to-output withstand 5656 VDC. Insulation resistance Input to output: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions EN55011 Class B; EN61000-3-2,3; FCC PART15 / CISPR22 Class B. EMC immunity EN61000-4-2,3,4,5,6,8,11; light-industry level, criteria A. The adapter's medical isolation and BF suitability must be assessed within the complete equipment. The finished system must be checked again for EMC compliance. Typical applications listed for this family include blood-glucose and blood-pressure meters, nebulizers, inhalers, portable medical devices and sleep-apnea devices. Dimensions, DC connection and installation Body dimensions 75.5 × 39.1 × 56.2 mm (L × W × H). Construction Fully enclosed 94V-0 flame-retardant plastic case; wall-mounted adapter format. Standard P1J DC plug Tuning-fork type; 2.1 mm ID × 5.5 mm OD; insertion length 11 ±0.5 mm. Centre positive, outside negative. Output cable for this model UL2468, 20 AWG, 1500 mm (+150/-0 mm length tolerance). Single-unit catalogue weight 192 g, the individual weight listed in PACKING; a reference value for this catalogue configuration. Fit the required regional AC plug to the interchangeable interface and match the equipment's DC connector and polarity. Follow the full mechanical drawing and the manufacturer's installation instructions. Compatible options and ordering AC plug-AU2 Australian type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-UK2 U.K. type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-EU2 European type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-US2 US type; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. AC plug-MIX2 Mixed set of all four listed types; compatible interchangeable AC plug for GEM18I / GEM30I / GEM40I. Optional locking DC plug P2S; SWITCHCRAFT S761K plug equivalent. Specify this option when ordering; the present -P1J model uses P1J. Other plug or cable configurations Available by customer request; confirm the exact configuration with the supplier. The AC plug kit is sold separately. P2S is an alternative DC connector configuration, not an additional plug included with the standard P1J unit. Reliability and measurement conditions Burn-in / manufacturer warranty 100% full-load burn-in test; the manufacturer's datasheet lists a 3-year warranty. Life rating 3 years at 100% load, 40°C, 12 operating hours per day. MTBF 400,000 hours minimum, MIL-HDBK-217F at 25°C. Default measurement conditions 230 VAC input, rated load, 25°C and 70% RH, unless otherwise stated. Voltage set point Measured at the plug terminals at 50% load. Ripple measurement 20 MHz bandwidth; 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors. Regulation definitions Tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low to high line at rated load; load regulation from 10% to 100% rated load. Catalogue revision 2016-07-14