GP Series: Triple Output Industrial Power Adapter

36 products

MEAN WELL UHP Series Low Profile Slim Power Supply (200W~1500W)

  • Product Features
  • General Specifications
  • Series Overview
  • Product Ordering Code

Product Features

  • Ultra-Slim Design: 1U low-profile form factor, perfectly suited for space-constrained industrial equipment.
  • Fanless & Conduction Cooled: Fanless design (for UHP-200/350/500) allows for silent operation and avoids dust accumulation issues.
  • High Efficiency: Extremely high efficiency up to 96%, reducing heat dissipation requirements.
  • Universal AC Input: Full-range input (90~264VAC) with active PFC (Power Factor Correction).
  • Rugged Performance: Wide operating temperature range (-30°C to +70°C) and capable of operating at altitudes up to 5000m.
  • Advanced Protections: Built-in short circuit, overload, over voltage, and over temperature protections.
  • Global Safety Standards: Approved for UL/EN/IEC 62368-1 standards.

General Specifications

Item Specification Detail
Input Voltage 90 ~ 264VAC / 127 ~ 370VDC
Operating Temp. -30°C to +70°C (Refer to derating curves)
Isolation Voltage I/P-O/P: 3KVAC, I/P-FG: 2KVAC, O/P-FG: 0.5KVAC
Safety Standards UL 62368-1, TUV EN 62368-1, EAC TP TC 004
EMC Emission BS EN/EN55032 Class B, EN61000-3-2
Altitude Up to 5000m (operating)
Protections Short circuit, Overload, Over voltage, Over temperature

Series Overview

Series Rated Power Profile Height Cooling Method
UHP-200 200W 26mm (1U) Conduction Cooling
UHP-350 350W 31mm (1U) Conduction Cooling
UHP-500 500W 31mm (1U) Conduction Cooling
UHP-750 750W 41mm (1.6U) Built-in DC Fan
UHP-1000 1000W 41mm (1.6U) Built-in DC Fan
UHP-1500 1500W 41mm (1.6U) Built-in DC Fan
Note: UHP-200/350/500 series are designed as fanless, conduction-cooled models. UHP-750/1000/1500 models feature built-in smart fan cooling systems.

Product Ordering Code

No. Item Code Description
1 Series Name UHP Ultra High Performance Slim Power Supply
2 Rated Power 200 ~ 1500 200W, 350W, 500W, 750W, 1000W, 1500W
3 Output Voltage 12 ~ 48 12V, 24V, 36V, 48V (Availability depends on specific wattage)
Example:
UHP-200-12 : 200W Series, 12V Output.
UHP-1500-48 : 1500W Series, 48V Output.
  • GP50A58F-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A58F-R1B

    MEAN WELL GP50A58F-R1B is a Class I desktop AC/DC adapter with three outputs: +16 V / +48 V / −16 V DC. It supplies 71.2 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Confirm the manufacturer-specific output pin assignment for this optional voltage set before wiring. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A58F-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +16 V / +48 V / −16 V DC, referenced to COM. Combined rated output power 71.2 W across all three outputs; subject to input and temperature derating. Efficiency, typical 86%. Configuration Optional ±16 V / +48 V video-system version, ordered as GP50A58F-R1B. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 58F identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 71.2 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +48 VDC relative to COM. Rated set current 0.15 A. Operating current range 0.03–0.15 A. Minimum load 0.03 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. For CH2, 0.15 A rated is 150 mA, with a 30 mA minimum load. CH3 Output Nominal voltage −16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Model-specific wiring Obtain the manufacturer-confirmed pin assignment for GP50A58F-R1B before connection. The +16 V / +48 V / −16 V model must not be wired from the generic +5 V pin table. Connector shell AC FG is identified on the connector drawing. The standard connector type is specified, but the combined sheet does not provide a separate pin table for this voltage set. Confirm every output pin and COM with the manufacturer before connecting the load. For a factory-requested stripped/tinned-lead version of GP50A58F-R1B, obtain the manufacturer-confirmed voltage-to-wire mapping for this exact model. Do not use the generic +5 V/red-wire assignment for the +16 V / +48 V / −16 V output set. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004 are listed. GP50A58F-R1B is explicitly excluded from the listed BS EN/EN62368-1 approval. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A58F-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A58F-R1B

    MEAN WELL GP50A58F-R1B is a Class I desktop AC/DC adapter with three outputs: +16 V / +48 V / −16 V DC. It supplies 71.2 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Confirm the manufacturer-specific output pin assignment for this optional voltage set before wiring. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A58F-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +16 V / +48 V / −16 V DC, referenced to COM. Combined rated output power 71.2 W across all three outputs; subject to input and temperature derating. Efficiency, typical 86%. Configuration Optional ±16 V / +48 V video-system version, ordered as GP50A58F-R1B. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 58F identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 71.2 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +48 VDC relative to COM. Rated set current 0.15 A. Operating current range 0.03–0.15 A. Minimum load 0.03 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. For CH2, 0.15 A rated is 150 mA, with a 30 mA minimum load. CH3 Output Nominal voltage −16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Model-specific wiring Obtain the manufacturer-confirmed pin assignment for GP50A58F-R1B before connection. The +16 V / +48 V / −16 V model must not be wired from the generic +5 V pin table. Connector shell AC FG is identified on the connector drawing. The standard connector type is specified, but the combined sheet does not provide a separate pin table for this voltage set. Confirm every output pin and COM with the manufacturer before connecting the load. For a factory-requested stripped/tinned-lead version of GP50A58F-R1B, obtain the manufacturer-confirmed voltage-to-wire mapping for this exact model. Do not use the generic +5 V/red-wire assignment for the +16 V / +48 V / −16 V output set. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004 are listed. GP50A58F-R1B is explicitly excluded from the listed BS EN/EN62368-1 approval. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A58F-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A58F-R1B

    MEAN WELL GP50A58F-R1B is a Class I desktop AC/DC adapter with three outputs: +16 V / +48 V / −16 V DC. It supplies 71.2 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Confirm the manufacturer-specific output pin assignment for this optional voltage set before wiring. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A58F-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +16 V / +48 V / −16 V DC, referenced to COM. Combined rated output power 71.2 W across all three outputs; subject to input and temperature derating. Efficiency, typical 86%. Configuration Optional ±16 V / +48 V video-system version, ordered as GP50A58F-R1B. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 58F identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 71.2 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +48 VDC relative to COM. Rated set current 0.15 A. Operating current range 0.03–0.15 A. Minimum load 0.03 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. For CH2, 0.15 A rated is 150 mA, with a 30 mA minimum load. CH3 Output Nominal voltage −16 VDC relative to COM. Rated set current 2 A. Operating current range 0.4–2 A. Minimum load 0.4 A. Ripple and noise, maximum 180 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Model-specific wiring Obtain the manufacturer-confirmed pin assignment for GP50A58F-R1B before connection. The +16 V / +48 V / −16 V model must not be wired from the generic +5 V pin table. Connector shell AC FG is identified on the connector drawing. The standard connector type is specified, but the combined sheet does not provide a separate pin table for this voltage set. Confirm every output pin and COM with the manufacturer before connecting the load. For a factory-requested stripped/tinned-lead version of GP50A58F-R1B, obtain the manufacturer-confirmed voltage-to-wire mapping for this exact model. Do not use the generic +5 V/red-wire assignment for the +16 V / +48 V / −16 V output set. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC 004 are listed. GP50A58F-R1B is explicitly excluded from the listed BS EN/EN62368-1 approval. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A14E-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A14E-R1B

    MEAN WELL GP50A14E-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +15 V / −15 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A14E-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +15 V / −15 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 14E identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +15 VDC relative to COM. Rated set current 1.5 A. Operating current range 0.3–1.5 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance −5% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −15 VDC (CH3). Pin 5 +15 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −15 V (CH3); wire 5 yellow is +15 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A14E-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A14E-R1B

    MEAN WELL GP50A14E-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +15 V / −15 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A14E-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +15 V / −15 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 14E identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +15 VDC relative to COM. Rated set current 1.5 A. Operating current range 0.3–1.5 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance −5% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −15 VDC (CH3). Pin 5 +15 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −15 V (CH3); wire 5 yellow is +15 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A14E-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A14E-R1B

    MEAN WELL GP50A14E-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +15 V / −15 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A14E-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +15 V / −15 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 14E identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +15 VDC relative to COM. Rated set current 1.5 A. Operating current range 0.3–1.5 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance −5% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −15 VDC (CH3). Pin 5 +15 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −15 V (CH3); wire 5 yellow is +15 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13D-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13D-R1B

    MEAN WELL GP50A13D-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −12 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13D-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −12 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13D identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +8%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −12 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −12 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13D-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13D-R1B

    MEAN WELL GP50A13D-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −12 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13D-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −12 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13D identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +8%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −12 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −12 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13D-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13D-R1B

    MEAN WELL GP50A13D-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −12 V DC. It supplies 50 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13D-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −12 V DC, referenced to COM. Combined rated output power 50 W across all three outputs; subject to input and temperature derating. Efficiency, typical 84%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13D identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 50 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −12 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +8%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −12 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −12 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13A-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13A-R1B

    MEAN WELL GP50A13A-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −5 V DC. It supplies 46.5 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13A-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −5 V DC, referenced to COM. Combined rated output power 46.5 W across all three outputs; subject to input and temperature derating. Efficiency, typical 83.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13A identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 46.5 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −5 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −5 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13A-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13A-R1B

    MEAN WELL GP50A13A-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −5 V DC. It supplies 46.5 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13A-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −5 V DC, referenced to COM. Combined rated output power 46.5 W across all three outputs; subject to input and temperature derating. Efficiency, typical 83.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13A identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 46.5 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −5 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −5 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP50A13A-R1B

    MEAN WELL GP50A series: Triple-Output Desktop AC/DC Adapter - GP50A13A-R1B

    MEAN WELL GP50A13A-R1B is a Class I desktop AC/DC adapter with three outputs: +5 V / +12 V / −5 V DC. It supplies 46.5 W combined at the rated channel currents, subject to minimum loads and derating. The standard R1B five-pin DIN connector and IEC320-C14 input suit industrial, telecommunications and electronic equipment. Product Datasheet Download MEAN WELL GP50A Datasheet (PDF) The GP50A section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and Combined Output Complete model GP50A13A-R1B. Product type Triple-output desktop AC/DC industrial adapter; Class I with protective earth. Output set +5 V / +12 V / −5 V DC, referenced to COM. Combined rated output power 46.5 W across all three outputs; subject to input and temperature derating. Efficiency, typical 83.5%. Configuration Standard three-output R1B version. Model code GP identifies the series; 50 is the nominal series wattage class; A identifies the IEC320-C14 three-pin AC format; 13A identifies the output-voltage set; R1B identifies the standard power DIN 5-pin connector. These three channels form one complete adapter. Keep every channel within its minimum and maximum current and keep the combined output within 46.5 W. The per-channel current limits are not independent extra-power allowances. CH1 Output Nominal voltage +5 VDC relative to COM. Rated set current 4 A. Operating current range 0–4 A. Minimum load 0 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output Nominal voltage +12 VDC relative to COM. Rated set current 2 A. Operating current range 0.3–2 A. Minimum load 0.3 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −5 VDC relative to COM. Rated set current 0.5 A. Operating current range 0.1–0.5 A. Minimum load 0.1 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance −5% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input and Energy AC input 90–264 VAC; 47–63 Hz. DC input 135–370 VDC. AC connection IEC320-C14 three-pole inlet with protective earth. Input current 1.6 A at 100 VAC; 0.8 A at 230 VAC. Cold-start inrush, maximum 35 A at 115 VAC; 65 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up At full load: 1500 / 50 / 20 ms at 230 VAC; 2500 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA 2007/DoE. Select a suitable mains lead for the C14 inlet and the installation outlet. Confirm mains-lead supply with the order; the datasheet does not state that an AC cord is included. The no-load-consumption rating does not replace the minimum channel loads required for regulated operation. Protection Short circuit / overload 120–200% of rated output power; hiccup mode with automatic recovery after the fault condition is removed. Overvoltage Zener-diode clamp with output short-circuit protection. No numerical trip threshold is specified. Cooling, Derating and Environment Working ambient −20 to +70°C, subject to derating. Temperature derating, horizontal 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage derating, 60 Hz 90% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the temperature and input-voltage limits together. Use the horizontal orientation shown in the derating curve and leave room for heat dissipation around the enclosure. Mechanical Details and Weight Nominal dimensions, L × W × H 146 × 75.5 × 43 mm. Enclosure Fully enclosed 94V-0 flame-retardant plastic case, power-on LED and four rubber feet. DC cable UL2464, 18 AWG × 5 conductors; 1000 mm with +150 / −0 mm tolerance. R1B mechanical dimensions The connector drawing marks 54.8 mm overall length, 10.2 mm tip length and 13.2 mm diameter; follow the drawing for orientation and clearance. Catalogue single-unit weight 550 g from the explicit PACKING value of 0.55 kg per unit; a catalogue packing reference, not a measured net or shipping weight. Packing 36 pieces / 21 kg per carton. Use the full drawing on PDF page 11 for the cable exit, connector, feet and nameplate positions. Body dimensions do not include the attached cable or plug. Output Connector and Optional Cable Standard connector R1B power DIN 5-pin male. Pins 1 and 2 COM. Pin 3 +5 VDC (CH1). Pin 4 −5 VDC (CH3). Pin 5 +12 VDC (CH2). Connector shell AC FG is identified on the connector drawing. Use the pin numbers and viewing direction in the PDF drawing. Confirm the mating connector and load polarity before connection; do not substitute another adapter merely because it has a five-pin DIN plug. For a factory-requested stripped/tinned-lead configuration, wire 1 black and wire 2 blue are COM; wire 3 red is +5 V (CH1); wire 4 white is −5 V (CH3); wire 5 yellow is +12 V (CH2); the drain wire is FG. Stripped and tinned leads are a customer-requested configuration, not an additional connector supplied with the standard R1B version. The illustrated lead length L is 70 mm and stripped length L1 is 10 mm; both can be specified by request. No complete alternate order code or separate mating-socket part number is given in these pages. Dual-output configurations are available by request. They are separate from this three-output model and require confirmation of the complete order code and electrical ratings. Safety and EMC Applicable safety standards IEC62368-1, UL62368-1, CSA22.2, BS EN/EN62368-1 and EAC TP TC 004 are listed as approved. Withstand voltage Input/output: 4242 VDC; input/FG: 2121 VDC. Isolation resistance Input/output and input/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2: Class A. Voltage flicker BS EN/EN61000-3-3. Immunity: BS EN/EN61000-4-2 ESD, level 3 at 8 kV air and level 2 at 4 kV contact; -4-3 RF, level 2 at 3 V/m; -4-4 EFT, level 2 at 1 kV; -4-5 surge, level 3 at 1 kV L–N and 2 kV L,N–PE; -4-6 conducted susceptibility, level 2 at 3 V. Under -4-11: >95% dip for 0.5 periods, 30% dip for 25 periods and >95% interruption for 250 periods. This is an independent power adapter. Reconfirm whole-system EMC compliance in the final equipment with its actual cabling and installation. Measurement Conditions and Reliability Test conditions Unless otherwise stated: 230 VAC input, rated load, 25°C and 70% RH. Voltage set point Measured at the plug terminal with 50% load. Ripple and noise method 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Life reference 3 years at 100% load, 40°C and 8 hours/day. MTBF, minimum 280 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3-year warranty, subject to applicable manufacturer terms. Catalogue revision GP50A-SPEC, 2026-01-09; combined PDF pages 9–12. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The channel-specific load-regulation values are listed above; Note 6 additionally states load regulation within ±5% and cross regulation within ±15% when measured from light load (20% of rated load) to full load. Meet all three minimum-load requirements, especially when loads change independently. The combined rating and individual rail ratings apply together.

    $155.74

  • GP25B58F-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B58F-R1B

    MEAN WELL GP25B58F-R1B provides +16 V, +48 V, −16 V outputs with a catalogue-rated total of 37.77 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B58F-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 58F the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 37.77 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 85%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +48 VDC. Rated current 0.087 A. Operating current range 0.017–0.087 A. Equivalent to 17–87 mA. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Provide the load protection required for the +16 V, +48 V and −16 V outputs. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B wiring for this output set Confirm the supplied-unit pin assignment for +16 V, +48 V, −16 V and common before connecting the load. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Match the mating connector and harness to the supplied ±16 V / +48 V configuration. Obtain its specific wiring assignment with the order. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. GP25B58F-R1B is excepted from the BS EN/EN62368-1 entry. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B58F-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B58F-R1B

    MEAN WELL GP25B58F-R1B provides +16 V, +48 V, −16 V outputs with a catalogue-rated total of 37.77 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B58F-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 58F the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 37.77 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 85%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +48 VDC. Rated current 0.087 A. Operating current range 0.017–0.087 A. Equivalent to 17–87 mA. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Provide the load protection required for the +16 V, +48 V and −16 V outputs. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B wiring for this output set Confirm the supplied-unit pin assignment for +16 V, +48 V, −16 V and common before connecting the load. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Match the mating connector and harness to the supplied ±16 V / +48 V configuration. Obtain its specific wiring assignment with the order. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. GP25B58F-R1B is excepted from the BS EN/EN62368-1 entry. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B58F-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B58F-R1B

    MEAN WELL GP25B58F-R1B provides +16 V, +48 V, −16 V outputs with a catalogue-rated total of 37.77 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B58F-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 58F the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 37.77 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 85%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +48 VDC. Rated current 0.087 A. Operating current range 0.017–0.087 A. Equivalent to 17–87 mA. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −16 VDC. Rated current 1.05 A. Operating current range 0.2–1.05 A. Ripple and noise, maximum 200 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Provide the load protection required for the +16 V, +48 V and −16 V outputs. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B wiring for this output set Confirm the supplied-unit pin assignment for +16 V, +48 V, −16 V and common before connecting the load. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Match the mating connector and harness to the supplied ±16 V / +48 V configuration. Obtain its specific wiring assignment with the order. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. GP25B58F-R1B is excepted from the BS EN/EN62368-1 entry. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B14E-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B14E-R1B

    MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B14E-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 14E the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 29 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80.5%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +15 VDC. Rated current 0.8 A. Operating current range 0.1–0.8 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance -5.0% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −15 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −15 VDC. R1B pin 5 CH2, +15 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −15 V; yellow: +15 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B14E-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B14E-R1B

    MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B14E-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 14E the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 29 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80.5%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +15 VDC. Rated current 0.8 A. Operating current range 0.1–0.8 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance -5.0% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −15 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −15 VDC. R1B pin 5 CH2, +15 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −15 V; yellow: +15 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B14E-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B14E-R1B

    MEAN WELL GP25B14E-R1B provides +5 V, +15 V, −15 V outputs with a catalogue-rated total of 29 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B14E-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 14E the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 29 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80.5%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +15 VDC. Rated current 0.8 A. Operating current range 0.1–0.8 A. Ripple and noise, maximum 150 mVp-p. Voltage tolerance -5.0% to +15%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −15 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −15 VDC. R1B pin 5 CH2, +15 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −15 V; yellow: +15 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13D-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13D-R1B

    MEAN WELL GP25B13D-R1B provides +5 V, +12 V, −12 V outputs with a catalogue-rated total of 28 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13D-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13D the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1 A. Operating current range 0.2–1 A. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5.0% to +5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −12 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −12 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −12 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13D-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13D-R1B

    MEAN WELL GP25B13D-R1B provides +5 V, +12 V, −12 V outputs with a catalogue-rated total of 28 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13D-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13D the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1 A. Operating current range 0.2–1 A. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5.0% to +5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −12 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −12 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −12 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13D-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13D-R1B

    MEAN WELL GP25B13D-R1B provides +5 V, +12 V, −12 V outputs with a catalogue-rated total of 28 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13D-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13D the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1 A. Operating current range 0.2–1 A. Ripple and noise, maximum 120 mVp-p. Voltage tolerance -5.0% to +5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −12 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −12 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −12 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13A-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13A-R1B

    MEAN WELL GP25B13A-R1B provides +5 V, +12 V, −5 V outputs with a catalogue-rated total of 28.5 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13A-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13A the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28.5 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1.2 A. Operating current range 0.2–1.2 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −5 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −5 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −5 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13A-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13A-R1B

    MEAN WELL GP25B13A-R1B provides +5 V, +12 V, −5 V outputs with a catalogue-rated total of 28.5 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13A-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13A the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28.5 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1.2 A. Operating current range 0.2–1.2 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −5 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −5 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −5 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96

  • GP25B13A-R1B

    MEAN WELL GP25B series: Triple-Output Desktop AC/DC Power Adapter - GP25B13A-R1B

    MEAN WELL GP25B13A-R1B provides +5 V, +12 V, −5 V outputs with a catalogue-rated total of 28.5 W. The Class II desktop adapter uses an IEC320-C8 inlet and an R1B male DIN connector. Select loads within the channel-current, total-power and derating limits. Product Datasheet Download MEAN WELL GP25B Datasheet (PDF) The GP25B section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and Three-Output Rating Complete model GP25B13A-R1B. Series and format GP25B triple-output desktop AC/DC adapter; Class II without FG and an IEC320-C8 two-pole inlet. Model code GP identifies the adapter series; 25 the power family; B the Class II C8 input format; 13A the output-voltage set; R1B the standard five-pin male DIN connector. Catalogue-rated total output power 28.5 W, subject to input-voltage and ambient-temperature derating. Efficiency, typical 80%. Select the load to remain within each channel current range and the total output-power rating simultaneously. Maintain the stated minimum loads for the specified regulation; the current-range maxima are not separate additional power allowances. CH1 Output DC output voltage +5 VDC. Rated current 2.5 A. Operating current range 0.5–2.5 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH2 Output DC output voltage +12 VDC. Rated current 1.2 A. Operating current range 0.2–1.2 A. Ripple and noise, maximum 100 mVp-p. Voltage tolerance -5.0% to +10%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Output DC output voltage −5 VDC. Rated current 0.3 A. Operating current range 0.1–0.3 A. Ripple and noise, maximum 50 mVp-p. Voltage tolerance ±3.0%. Line regulation ±1.0%. Load regulation ±3.0%. Input, Start-Up and Energy Input range 90–264 VAC or 135–370 VDC; AC frequency 47–63 Hz. AC connection IEC320-C8 two-pole inlet; Class II construction without a protective-earth connection. Input current 0.8 A at 100 VAC; 0.4 A at 230 VAC. Cold-start inrush, maximum 30 A at 115 VAC; 60 A at 230 VAC. Leakage current, maximum 0.75 mA at 240 VAC. Set-up / rise / hold-up times At full load: 800 / 50 / 20 ms at 230 VAC; 1200 / 50 / 16 ms at 115 VAC. No-load consumption <0.3 W. Energy efficiency Level VI; EISA2007/DoE. Choose a mains lead suitable for the C8 inlet and the local supply. Confirm mains-lead inclusion with the order. Protection Short circuit / overload 110–160% of rated total output power; hiccup mode, with automatic recovery after the fault is removed. Overvoltage on the 5 V output Zener-diode clamp with output shorting; the listed overvoltage function is limited to the 5 V output. Temperature, Input Derating and Environment Working ambient −20 to +70°C, subject to the derating curve. Horizontal temperature curve 100% load from −20°C through 40°C; 70% at 50°C, 50% at 60°C and 40% at 70°C. Input-voltage curve, 60 Hz 90% load at 90 VAC; 100% from 100 through 264 VAC. Operating humidity 20–90% RH, non-condensing. Storage −20 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over −20 to +40°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Apply the input and ambient limits together and allow unobstructed heat dissipation around the enclosure. Mechanical Details and Installation Dimensions, L × W × H 107.5 × 67 × 36 mm. Enclosure and indicator Fully enclosed 94V-0 flame-retardant plastic case; power-on LED indicator and four rubber feet. Output cable UL2464, 18 AWG × 3 conductors and 20 AWG × 2 conductors; length 1530 mm, tolerance +150/−0 mm. Standard output plug R1B five-pin male DIN; use the connector drawing to identify the viewing direction and contact positions. Catalogue single-unit weight 300 g from the explicit 0.3 kg single-unit PACKING entry; a catalogue reference, not a measured parcel weight. Packing 54 pieces / 20 kg. Allow clearance for the inlet, cable and connector. Use the full mechanical drawing for connector orientation and installation dimensions. Output Connection and Optional Leads R1B pins 1 / 2 COM / COM. R1B pin 3 CH1, +5 VDC. R1B pin 4 CH3, −5 VDC. R1B pin 5 CH2, +12 VDC. Optional stripped and tinned output Lead-end configuration by customer request; standard exposed-lead dimension L = 70 mm and tinned length L1 = 10 mm, with other lengths available by request. Optional lead colour code Black and blue: COM; red: +5 V; white: −5 V; yellow: +12 V. Check the drawing view before wiring the male DIN connector. Select a mating connector and harness rated for every output and common return. Configuration Options The ordered -R1B model has the standard five-pin male DIN output. Stripped and tinned leads and dual-output configurations are separate options to agree with the manufacturer; they are not additional outputs or supplied loose accessories for this model. The GP25B58F-R1B configuration provides +16 V, +48 V and −16 V for suitable video-system loads. Select by the complete model code and the required load currents. Safety and EMC Safety standards IEC62368-1, UL62368-1, CSA22.2 and EAC TP TC004 are listed. BS EN/EN62368-1 is also listed for this model. Input-to-output withstand 4242 VDC. Input-to-output insulation 100 MΩ at 500 VDC, 25°C and 70% RH. Conducted and radiated emissions BS EN/EN55032 (CISPR32), FCC Part 15 / CISPR22 and CAN ICES-3(B) / NMB-3(B): Class B. Harmonic current BS EN/EN61000-3-2, Class A. Voltage fluctuations and flicker BS EN/EN61000-3-3. ESD immunity BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact. Radiated RF immunity BS EN/EN61000-4-3: Level 2, 3 V/m. Electrical fast transient / burst BS EN/EN61000-4-4: Level 2, 1 kV. Surge immunity BS EN/EN61000-4-5: Level 3, 1 kV line-to-neutral. Conducted RF immunity BS EN/EN61000-4-6: Level 2, 3 V. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 period; 30% dip for 25 periods; >95% interruption for 250 periods. The adapter is a component of the final equipment. Confirm EMC compliance in the completed installation. Reliability and Measurement Conditions MTBF 620,000 hours minimum, MIL-HDBK-217F at 25°C. Design-life condition 3 years at 100% load, 40°C and 8 operating hours per day. Manufacturer warranty The series datasheet lists a 3-year warranty, subject to the manufacturer’s terms. Unless otherwise stated, specifications use 230 VAC input, rated load, 25°C and 70% RH. Output voltage is set at the plug terminal with 50% load. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Line regulation is measured from low line to high line at rated load. The measurement note specifies load regulation over 20% to 100% rated load and cross regulation within ±15%; observe the individual channel limits and minimum-load ranges above.

    $105.96


You have seen 24 out of 36 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa