HDR:DIN Rail Power Supply

31 products

MEAN WELL HDR Series Ultra-Slim Step Shape DIN Rail Power Supply

Complete Portfolio: 15W to 150W | Class II Isolation | OVC III | Smart Building Automation

  • Series Overview
  • Low Power (15W~60W)
  • Mid Power (100W~150W)
  • Safety & Protections
  • Dimensions (SU)

Designed for Building Automation & Household Systems

The MEAN WELL HDR Series is an economical, ultra-slim, step-shaped DIN rail power supply family. Designed specifically for distribution boards and smart home integration, the series scales perfectly from 15W up to 150W.

Core Architectural Advantages

  • Ultra-Slim Step Shape: The compact, plastic-housed design mimics the profile of standard circuit breakers, allowing it to fit perfectly inside consumer units and distribution cabinets. Width ranges from 1SU (17.5mm) to 6SU (105mm).
  • Class II Isolation: Double-insulated design with no ground (FG) pin required, enhancing safety for residential and commercial building installations.
  • OVC III Compliance: Meets Overvoltage Category III standards (EN61558), ensuring high reliability in electrical environments subject to surges.
  • Energy Efficient: Features ultra-low no-load power consumption (generally <0.3W) making it highly suitable for "always-on" smart home systems.

HDR-15, HDR-30, & HDR-60 Specifications

The ultra-compact low-power tier is perfect for single-sensor, IoT gateway, or localized lighting applications. These units easily snap onto standard TS-35/7.5 or TS-35/15 DIN rails.

Model Series Max Rated Power DC Output Voltages Efficiency (Max) Width
HDR-15 15.2W 5V, 12V, 15V, 24V, 48V 87% 1 SU (17.5mm)
HDR-30 36W 5V, 12V, 15V, 24V, 48V 90% 2 SU (35mm)
HDR-60 60W 5V, 12V, 15V, 24V, 48V 91% 3 SU (52.5mm)
Universal Input: All models accept a wide input range of 85 ~ 264VAC (or 120 ~ 370VDC), ensuring compatibility with global power grids.

HDR-100 & HDR-150 Specifications

For more robust automation systems, security networks, and LED lighting arrays, the 100W and 150W models provide higher capacity while maintaining the step-shape profile.

Model Series Max Rated Power DC Output Voltages Efficiency (Max) Width
HDR-100 92W 12V, 15V, 24V, 48V 90% 4 SU (70mm)
HDR-100-xxN 100.8W 12V, 15V, 24V, 48V 90% 4 SU (70mm)
HDR-150 153.6W 12V, 15V, 24V, 48V 90.5% 6 SU (105mm)
Note on HDR-100 variants: The standard HDR-100 complies with LPS (Limited Power Source) requirements. The "N" variants (e.g., HDR-100-24N) offer a slightly higher output wattage and do not have LPS restrictions. Notice that 5V models are not available in the 100W/150W tiers.

System Protections & Certifications

Built-In Protections

  • Over Load (Overcurrent): Utilizes a dual-mode protection strategy. It operates in constant current limiting mode when voltage drops (e.g., 50%~100%), and switches to hiccup mode for severe drops (<50%). Recovers automatically.
  • Over Voltage: Circuit safeguards prevent the output voltage from spiking and damaging connected sensitive electronics (shut down output voltage, clamped by zener diode).
  • Short Circuit: Hiccup mode protection ensures the power supply remains safe during a dead short and recovers automatically once the fault is cleared.

Global Safety Compliance

  • Approvals: UL62368-1, UL508 (Industrial Control Equipment), TUV EN61558-2-16, IEC62368-1.
  • Isolation: I/P-O/P: 4KVAC (Class II double insulation).
  • Operating Temperature: Wide functional range from -30°C up to +70°C (refer to derating curves for high-temperature performance).

Standard Unit (SU) Dimensions

The HDR series is sized according to standard DIN rail breaker widths (1 SU = 17.5mm), making panel layout calculations incredibly straightforward.

Physical Dimensions (W * H * D)

  • HDR-15 (1 SU): 17.5 * 90 * 54.5 mm
  • HDR-30 (2 SU): 35 * 90 * 54.5 mm
  • HDR-60 (3 SU): 52.5 * 90 * 54.5 mm
  • HDR-100 (4 SU): 70 * 90 * 54.5 mm
  • HDR-150 (6 SU): 105 * 90 * 54.5 mm
Installation: All units are housed in a fully isolated UL94V-0 flame-retardant plastic case. They are designed to clip easily onto standard TS-35/7.5 or TS-35/15 DIN rails without the need for additional mounting brackets.
  • HDR-30-24

    MEAN WELL HDR-30 series: Ultra-Slim DIN Rail Power Supply - HDR-30-24

    MEAN WELL HDR-30-24 is an ultra-slim single-output DIN rail power supply rated at 24 V DC, 1.5 A and 36 W. Its plastic housing is 35 mm wide (2 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-30 Datasheet (PDF) The HDR-30 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-30-24; HDR-30 catalogue revision 2026-04-03. The final code identifies the nominal 24 V output. Rated output 24 V DC / 1.5 A / 36 W; current range 0–1.5 A. Voltage adjustment 21.6–29 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 89% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 36 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 0.88 A at 115 VAC; 0.48 A at 230 VAC. Typical cold-start inrush 25 A at 115 VAC; 45 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 30–36 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +50°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is listed for this voltage; the family’s 48 V version is excluded. Design reference TUV BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 35 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-30. Width: 2 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1: +V; pin 2: −V; pin 3: AC/L; pin 4: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 130 g per unit. Complete PACKING entry: 0.13 kg; 96 pcs / 14.2 kg / 1.04 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 8 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-30 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3670.4 K hours minimum, Telcordia SR-332 (Bellcore); 968.1 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • MEAN WELL HDR-15 series: Ultra-Slim DIN Rail Power Supply - HDR-15-5 MEAN WELL HDR-15 series: Ultra-Slim DIN Rail Power Supply - HDR-15-5

    MEAN WELL HDR-15 series: Ultra-Slim DIN Rail Power Supply - HDR-15-5

    MEAN WELL HDR-15-5 is an ultra-slim single-output DIN rail power supply rated at 5 V DC, 2.4 A and 12 W. Its plastic housing is 17.5 mm wide (1 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-15 Datasheet (PDF) The HDR-15 section is on PDF pages 1, 2, 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-15-5; HDR-15 catalogue revision 2026-04-03. The final code identifies the nominal 5 V output. Rated output 5 V DC / 2.4 A / 12 W; current range 0–2.4 A. Voltage adjustment 4.5–5.5 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 80 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 80% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 12 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 0.5 A at 115 VAC; 0.25 A at 230 VAC. Typical cold-start inrush 25 A at 115 VAC; 45 A at 230 VAC. Setup / rise at full load 2000 / 80 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 110–145% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 5.75–6.75 V. Overvoltage response Shut off output voltage, clamping by zener diode. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +50°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is listed for this voltage; the family’s 48 V version is excluded. Design reference TUV BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 17.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-15. Width: 1 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1: +V; pin 2: −V; pin 3: AC/N; pin 4: AC/L. Terminal torque shown on drawing DC terminals: 5 lb-in; AC terminals: 5 lb-in. These values are printed on the representative label in the mechanical drawing; follow the supplied unit’s marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 74 g per unit. Complete PACKING entry: 74 g; 160 pcs / 12.9 kg / 1.09 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 4 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-15 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3724.3 K hours minimum, Telcordia SR-332 (Bellcore); 1166.1 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-150-48

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-48

    MEAN WELL HDR-150-48 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 48 V DC at 3.2 A / 153.6 W with 230 VAC input, or 2.72 A / 130.6 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-48 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 48 output code 48 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 48 V DC At 115 VAC input 2.72 A; catalogue-rated power 130.6 W. At 230 VAC input 3.2 A; catalogue-rated power 153.6 W. Voltage adjustment 43.2–55.2 V DC. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 90.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 56.5–64.8 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 48 V branch starts at 75% load at 85 VAC, reaches 85% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. The catalogue excludes the 48 V model from its BIS IS13252 listing. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-24

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-24

    MEAN WELL HDR-150-24 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 24 V DC at 6.25 A / 150 W with 230 VAC input, or 5.31 A / 127.4 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-24 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 24 output code 24 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 24 V DC At 115 VAC input 5.31 A; catalogue-rated power 127.4 W. At 230 VAC input 6.25 A; catalogue-rated power 150 W. Voltage adjustment 21.6–29 V DC. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 90.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 30–36 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 24 V branch starts at 75% load at 85 VAC, reaches 85% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-15

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-15

    MEAN WELL HDR-150-15 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 15 V DC at 9.5 A / 142.5 W with 230 VAC input, or 8.55 A / 128.3 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-15 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 15 output code 15 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 15 V DC At 115 VAC input 8.55 A; catalogue-rated power 128.3 W. At 230 VAC input 9.5 A; catalogue-rated power 142.5 W. Voltage adjustment 13.5–18 V DC. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 89.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 18.8–22.5 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 15 V branch starts at 75% load at 85 VAC, reaches 90% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-12

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-12

    MEAN WELL HDR-150-12 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 12 V DC at 11.3 A / 135.6 W with 230 VAC input, or 10.2 A / 122.4 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-12 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 12 output code 12 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 12 V DC At 115 VAC input 10.2 A; catalogue-rated power 122.4 W. At 230 VAC input 11.3 A; catalogue-rated power 135.6 W. Voltage adjustment 10.8–13.8 V DC. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 89% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 14.2–16.2 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 12 V branch starts at 75% load at 85 VAC, reaches 90% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The representative HDR-150-12 label in the mechanical drawing specifies copper wire only and a pollution degree 2 environment; follow the supplied unit’s marking and installation instructions. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-48

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-48

    MEAN WELL HDR-150-48 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 48 V DC at 3.2 A / 153.6 W with 230 VAC input, or 2.72 A / 130.6 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-48 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 48 output code 48 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 48 V DC At 115 VAC input 2.72 A; catalogue-rated power 130.6 W. At 230 VAC input 3.2 A; catalogue-rated power 153.6 W. Voltage adjustment 43.2–55.2 V DC. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 90.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 56.5–64.8 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 48 V branch starts at 75% load at 85 VAC, reaches 85% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. The catalogue excludes the 48 V model from its BIS IS13252 listing. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-24

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-24

    MEAN WELL HDR-150-24 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 24 V DC at 6.25 A / 150 W with 230 VAC input, or 5.31 A / 127.4 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-24 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 24 output code 24 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 24 V DC At 115 VAC input 5.31 A; catalogue-rated power 127.4 W. At 230 VAC input 6.25 A; catalogue-rated power 150 W. Voltage adjustment 21.6–29 V DC. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 90.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 30–36 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 24 V branch starts at 75% load at 85 VAC, reaches 85% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-15

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-15

    MEAN WELL HDR-150-15 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 15 V DC at 9.5 A / 142.5 W with 230 VAC input, or 8.55 A / 128.3 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-15 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 15 output code 15 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 15 V DC At 115 VAC input 8.55 A; catalogue-rated power 128.3 W. At 230 VAC input 9.5 A; catalogue-rated power 142.5 W. Voltage adjustment 13.5–18 V DC. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 89.5% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 18.8–22.5 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 15 V branch starts at 75% load at 85 VAC, reaches 90% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-150-12

    MEAN WELL HDR-150 series: DIN Rail AC/DC Power Supply - HDR-150-12

    MEAN WELL HDR-150-12 is a Class II DIN rail AC/DC power supply for household, building and industrial control. It delivers 12 V DC at 11.3 A / 135.6 W with 230 VAC input, or 10.2 A / 122.4 W with 115 VAC input. Select the load for the actual input voltage and ambient-temperature derating. Product Datasheet Download MEAN WELL HDR-150 Datasheet (PDF) The HDR-150 section is on PDF pages 17, 18, 19, 20. Refer to the complete mechanical drawings and notes when planning installation. Model Identification Complete model HDR-150-12 HDR Series name; slim step-shaped DIN rail power supply. 150 Nominal series wattage designation; use this model’s input-dependent ratings below. 12 output code 12 V nominal DC output. Configuration The published HDR-150 model code specifies series, nominal wattage and output voltage; no input-range selector or N suffix is defined for this model. DC Output Ratings Nominal output voltage 12 V DC At 115 VAC input 10.2 A; catalogue-rated power 122.4 W. At 230 VAC input 11.3 A; catalogue-rated power 135.6 W. Voltage adjustment 10.8–13.8 V DC. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%. Efficiency, typical 89% under the catalogue’s default test conditions. Observe both the applicable current and power ratings when adjusting the output. The 115 VAC and 230 VAC ratings are operating conditions of this complete model, not different SKU suffixes. Ripple and noise are measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF plus 47 µF capacitors connected in parallel at the termination. AC/DC Input and Starting AC input 85–264 VAC universal input; 277 VAC is specified as operational. DC input 120–370 VDC; 390 VDC is specified as operational. Input frequency 47–63 Hz. AC input current, typical 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Setup / rise time 500 ms / 60 ms at either 230 VAC or 115 VAC, at full load. Hold-up time, typical 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load consumption Less than 0.3 W. Protection and Status Short-circuit / overload protection Overload threshold: 105–135% of rated output power. Overload below 50% output voltage Hiccup mode when output voltage is below 50% of rated output voltage; automatic recovery after the fault is removed. Overload at 50–100% output voltage Constant-current limiting within 50–100% of rated output voltage; automatic recovery after the fault is removed. Overvoltage protection 14.2–16.2 V. Output shuts down; re-power to recover. Power indication Power-on LED, shown on the mechanical drawing. Cooling, Derating and Environment Cooling / operating temperature Free-air convection; -30 to +70°C, subject to the vertical-mounting derating curve. Vertical temperature curve 100% load from -30°C to 45°C; reduce along the plotted line to 50% at 70°C. The 70°C limit does not permit full load. Input-voltage curve, 60 Hz The 12 V branch starts at 75% load at 85 VAC, reaches 90% at 100 VAC, stays at that plateau below 120 VAC, then steps to 100% at 120 VAC. The full-load line continues to 277 VAC, marked operational. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–45°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting complies with IEC60068-2-6. Operating altitude 2000 m is the specified operating-altitude rating. Altitude note The catalogue additionally states a 3.5°C ambient derating per 1000 m above 2000 m for fanless models. This note does not by itself extend the listed 2000 m operating or overvoltage-category rating. Apply temperature and input-voltage limits together, using the complete graphs for intermediate operating points. The individual current and wattage ratings in the specification table remain the selection limits at 115 VAC and 230 VAC. Dimensions, Terminals and DIN Rail Installation Rated dimensions 105 × 90 × 54.5 mm (W × H × D); 105 mm width equals 6 SU. Plastic housing; case HDR-150. Drawing tolerance ±0.5 mm. The side drawing additionally marks 58.4, 63.65 and 45.15 mm; use their actual drawing locations when checking cabinet clearance. Compatible mounting rails TS-35/7.5 or TS-35/15; the rail illustration marks 35 mm width. AC input terminals 1 = AC/N; 2 = AC/L. DC output terminals 3 and 4 = -V; 5 and 6 = +V. Installation orientation Use the vertical orientation corresponding to the thermal curve; preserve the natural-convection path. The representative HDR-150-12 label in the mechanical drawing specifies copper wire only and a pollution degree 2 environment; follow the supplied unit’s marking and installation instructions. The illustrated rails identify compatible mounting profiles; the catalogue does not specify a supplied rail, bracket kit, connector kit or separate accessory ordering code for this model. Refer to the complete mechanical drawing and the manufacturer installation manual for the final installation. Safety and Insulation Insulation class Class II. Overvoltage category Category III according to EN62368, EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m altitude. Catalogue-listed approvals IEC62368-1; UL62368-1; UL61010; TUV BS EN/EN61558-2-16 and BS EN/EN61558-1; EAC TP TC004. BIS IS13252 (Part 1):2010 / IEC60950-1:2005 is also listed for this voltage model. Design references BS EN/EN50178 and TUV BS EN/EN62368-1; distinguish design references from listed approvals. Withstand voltage Input–output: 4 kVAC. Insulation resistance Input–output: 100 MΩ at 500 VDC, 25°C and 70% RH. Class II insulation is the specified classification; do not treat it as a Class 2 or LPS rating. EMC and Final-System Conditions Conducted emissions BS EN/EN55032 (CISPR32), Class B. Radiated emissions BS EN/EN55032 (CISPR32): Class B at 230 VAC; the catalogue note specifies Class A at 110 VAC. Harmonic current BS EN/EN61000-3-2 Class A, tested at 70% load. Voltage flicker BS EN/EN61000-3-3. Immunity standards BS EN/EN55024 and BS EN/EN61000-6-2. ESD BS EN/EN61000-4-2: Level 3, 8 kV air; Level 2, 4 kV contact; criterion A. Radiated susceptibility / EFT-burst / conducted immunity BS EN/EN61000-4-3, -4 and -6 respectively: Level 3, criterion A. Surge BS EN/EN61000-4-5: Level 4, 2 kV L–N, criterion A. Magnetic field BS EN/EN61000-4-8: Level 4, criterion A. Voltage dips and interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The datasheet treats this supply as an independent unit, but still requires EMC compliance to be reconfirmed for the complete final equipment. Weight, Reliability and Reference Conditions Catalogue unit weight 310 g: 0.31 kg in PACKING, a catalogue packing reference per unit, not a measured net weight or a shipment weight. MTBF 3046.3 K hours minimum, Telcordia SR-332 (Bellcore); 535.9 K hours minimum, MIL-HDBK-217F at 25°C. Reliability reference values are not guaranteed service life. Manufacturer warranty statement The manufacturer catalogue lists a three-year warranty, subject to the applicable manufacturer terms. Default measurement conditions Unless otherwise specified: 230 VAC input, rated load and 25°C ambient temperature. Applicable datasheet HDR-150-SPEC, 2026-04-03; combined HDR catalogue pages 17–20.

  • HDR-100-48N

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-48N

    MEAN WELL HDR-100-48N is a 48 VDC, 2.1 A, 100.8 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This N-suffix version is non-LPS, with a 43.2–55.2 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-48N code selects the 48 V output and the N-suffix configuration. Non-LPS; its permitted voltage adjustment is 43.2–55.2 V. Rated DC output 48 V; 2.1 A; 100.8 W. Output current range: 0–2.1 A. Use these exact model ratings with the derating limits below. Voltage adjustment 43.2–55.2 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 240 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 90% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Non-LPS. Do not apply the blank-suffix LPS statement to this N model. Short circuit / overload Short-circuit and overload protection; overload threshold 105–150% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 56.5–64.8 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. For this N configuration, the harmonic-current test is at 90% load, as specified in note 4. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-24N

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-24N

    MEAN WELL HDR-100-24N is a 24 VDC, 4.2 A, 100.8 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This N-suffix version is non-LPS, with a 21.6–29 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-24N code selects the 24 V output and the N-suffix configuration. Non-LPS; its permitted voltage adjustment is 21.6–29 V. Rated DC output 24 V; 4.2 A; 100.8 W. Output current range: 0–4.2 A. Use these exact model ratings with the derating limits below. Voltage adjustment 21.6–29 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 90% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Non-LPS. Do not apply the blank-suffix LPS statement to this N model. Short circuit / overload Short-circuit and overload protection; overload threshold 105–150% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 30–36 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. For this N configuration, the harmonic-current test is at 90% load, as specified in note 4. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-15N

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-15N

    MEAN WELL HDR-100-15N is a 15 VDC, 6.5 A, 97.5 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This N-suffix version is non-LPS, with a 13.5–18 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-15N code selects the 15 V output and the N-suffix configuration. Non-LPS; its permitted voltage adjustment is 13.5–18 V. Rated DC output 15 V; 6.5 A; 97.5 W. Output current range: 0–6.5 A. Use these exact model ratings with the derating limits below. Voltage adjustment 13.5–18 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 89% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Non-LPS. Do not apply the blank-suffix LPS statement to this N model. Short circuit / overload Short-circuit and overload protection; overload threshold 105–150% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 18.8–22.5 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. For this N configuration, the harmonic-current test is at 90% load, as specified in note 4. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-12N

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-12N

    MEAN WELL HDR-100-12N is a 12 VDC, 7.5 A, 90 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This N-suffix version is non-LPS, with a 12–13.8 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-12N code selects the 12 V output and the N-suffix configuration. Non-LPS; its permitted voltage adjustment is 12–13.8 V. Rated DC output 12 V; 7.5 A; 90 W. Output current range: 0–7.5 A. Use these exact model ratings with the derating limits below. Voltage adjustment 12–13.8 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±2.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 88% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Non-LPS. Do not apply the blank-suffix LPS statement to this N model. Short circuit / overload Short-circuit and overload protection; overload threshold 105–150% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 14.2–16.2 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. For this N configuration, the harmonic-current test is at 90% load, as specified in note 4. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-48

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-48

    MEAN WELL HDR-100-48 is a 48 VDC, 1.92 A, 92.2 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This blank-suffix version is LPS, with a 48–48.7 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-48 code selects the 48 V output and the blank-suffix configuration. Passes LPS (Limited Power Source); its permitted voltage adjustment is 48–48.7 V. Rated DC output 48 V; 1.92 A; 92.2 W. Output current range: 0–1.92 A. Use these exact model ratings with the derating limits below. Voltage adjustment 48–48.7 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 240 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 90% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Passes LPS (Limited Power Source). The narrower adjustment range is the range specified for this configuration. Short circuit / overload Short-circuit and overload protection; overload threshold 102–110% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 56.5–64.8 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-24

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-24

    MEAN WELL HDR-100-24 is a 24 VDC, 3.83 A, 92 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This blank-suffix version is LPS, with a 24–25.5 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-24 code selects the 24 V output and the blank-suffix configuration. Passes LPS (Limited Power Source); its permitted voltage adjustment is 24–25.5 V. Rated DC output 24 V; 3.83 A; 92 W. Output current range: 0–3.83 A. Use these exact model ratings with the derating limits below. Voltage adjustment 24–25.5 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 90% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Passes LPS (Limited Power Source). The narrower adjustment range is the range specified for this configuration. Short circuit / overload Short-circuit and overload protection; overload threshold 102–110% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 30–36 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-15

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-15

    MEAN WELL HDR-100-15 is a 15 VDC, 6.13 A, 92 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This blank-suffix version is LPS, with a 15–17 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-15 code selects the 15 V output and the blank-suffix configuration. Passes LPS (Limited Power Source); its permitted voltage adjustment is 15–17 V. Rated DC output 15 V; 6.13 A; 92 W. Output current range: 0–6.13 A. Use these exact model ratings with the derating limits below. Voltage adjustment 15–17 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±1.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 89% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Passes LPS (Limited Power Source). The narrower adjustment range is the range specified for this configuration. Short circuit / overload Short-circuit and overload protection; overload threshold 102–110% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 18.8–22.5 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-100-12

    MEAN WELL HDR-100 series: DIN Rail AC/DC Power Supply - HDR-100-12

    MEAN WELL HDR-100-12 is a 12 VDC, 7.1 A, 85.2 W single-output DIN rail AC/DC power supply. Its 70 mm-wide plastic Class II housing mounts on TS-35/7.5 or TS-35/15 rails and cools by free-air convection. This blank-suffix version is LPS, with a 12–13 V adjustment range, power-ON LED and model-specific protection limits. Product Datasheet Download MEAN WELL HDR-100 Datasheet (PDF) The HDR-100 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Complete model / suffix The complete HDR-100-12 code selects the 12 V output and the blank-suffix configuration. Passes LPS (Limited Power Source); its permitted voltage adjustment is 12–13 V. Rated DC output 12 V; 7.1 A; 85.2 W. Output current range: 0–7.1 A. Use these exact model ratings with the derating limits below. Voltage adjustment 12–13 V. Observe the rated current and power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth, a 12-inch twisted pair and parallel 0.1 µF / 47 µF capacitors. Accuracy / regulation Voltage tolerance ±2.0%; line regulation ±1.0%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 88% at the default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. HDR-100 is the family designation; use the exact voltage, current and wattage for this model. Input, Timing and Low-load Operation Rated input range 85–264 VAC or 120–370 VDC; 47–63 Hz AC. The catalogue additionally states operation at 277 VAC and 390 VDC. Typical AC current 3 A at 115 VAC; 1.6 A at 230 VAC. Cold-start inrush 35 A at 115 VAC; 70 A at 230 VAC, typical. Setup / rise time 500 ms / 60 ms at 230 VAC and 500 ms / 60 ms at 115 VAC, at full load. Typical hold-up time 30 ms at 230 VAC; 12 ms at 115 VAC, at full load. No-load power Less than 0.3 W. The N suffix changes output performance and LPS status; it does not select a different AC/DC input-voltage range. Follow the actual unit marking and the applicable installation requirements for the approved installation. Protection and Output Classification LPS configuration Passes LPS (Limited Power Source). The narrower adjustment range is the range specified for this configuration. Short circuit / overload Short-circuit and overload protection; overload threshold 102–110% of rated output power. Overload response Below 50% of rated output voltage: hiccup operation, with automatic recovery after the fault is removed. Within 50–100% of rated output voltage: constant-current limiting, with automatic recovery after the fault is removed. Overvoltage 14.2–16.2 V threshold; output shutdown, with re-powering required to recover. Insulation class Class II insulation with a plastic housing. This insulation classification is separate from the limited-power-source classification. Protection thresholds describe fault response, not permitted continuous overload or an additional peak-power rating. Cooling and Load Derating Cooling / orientation Free-air convection; the published curves are for vertical installation. Keep ventilation paths clear. Ambient operating range −30°C to +70°C, subject to the input-specific thermal curve. At 230 VAC input 100% load through +50°C, then decreasing linearly to 50% at +70°C. At 110 VAC input 100% load through +45°C, then decreasing linearly to 50% at +70°C. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 115 VAC, and stays at 100% through the 277 VAC operational point. Altitude / overvoltage category Operating altitude: 2000 m. Overvoltage category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Apply input and ambient limits together. The catalogue’s general altitude note gives a 3.5°C ambient reduction per additional 1000 m for fanless models above 2000 m; this note does not by itself extend the stated 2000 m operating-altitude or category rating. Confirm the permitted load for the actual enclosure, input voltage and unit marking. The maximum temperature is not a full-load guarantee. DIN Rail, Terminals and Installation Compatible rail profiles TS-35/7.5 or TS-35/15, both 35 mm DIN rails. These are mounting profiles, not a supplied rail quantity or a separate MEAN WELL accessory order code. Body / mounting space 70 × 90 × 54.5 mm (W × H × D); 70 mm width equals 4SU. The dimension drawing has a general tolerance of ±0.5 mm and a 58.4 mm overall side-profile extent including the rear rail-mounting feature. AC terminals Terminal 1: AC/L. Terminal 2: AC/N. DC terminals Terminals 3 and 4: −V. Terminals 5 and 6: +V. Local indication / adjustment Power-ON LED indicator and adjustable DC output voltage. Accessories / external controls These pages identify the compatible rail profiles but no dedicated bracket, rail-adapter, cable or connector-kit order code. No remote-control, remote-sense, auxiliary-output or current-sharing interface is specified. Use the complete mounting and terminal drawing on PDF page 16. Follow the actual unit label and manufacturer installation manual for conductor type, terminal torque and approved installation conditions; illustrated label values must not be assumed to apply to every output variant. The catalogue does not specify included rails or installation-hardware quantities. Installation and wiring clearance must keep ventilation and terminal access unobstructed. Environment and Mechanical Reliability Humidity Operating: 20–90% RH, non-condensing. Storage: 10–95% RH, non-condensing. Storage temperature −40°C to +85°C. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Mounting compliance: IEC60068-2-6. Catalogue unit weight 270 g (0.27 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Bulk packing reference 48 pieces / 13.74 kg / 0.96 CUFT. The carton mass is not the individual unit weight or the quantity supplied with one product. MTBF reference 3271.9 K hours minimum, Telcordia SR-332 (Bellcore); 856.5 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not guaranteed service life. Safety and EMC Conditions Safety standards listed UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004, BSMI CNS15598-1, and BIS IS13252(Part1):2010 / IEC60950-1:2005 are listed as approved. Design reference: TUV BS EN/EN62368-1. BIS marking condition The catalogue notes that some models may not carry the BIS logo. Confirm the required marking for the exact model and supplied unit. Withstand / insulation Input-to-output: 4 kVAC; 100 MΩ insulation resistance at 500 VDC, 25°C and 70% RH. Conducted / radiated emissions BS EN/EN55032 (CISPR32) and CNS15936, Class B. Harmonic current / flicker BS EN/EN61000-3-2, Class A; BS EN/EN61000-3-3 for voltage flicker. Immunity standards BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. ESD BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criteria A. Radiated / burst immunity BS EN/EN61000-4-3 and -4: level 3, criteria A. Surge immunity BS EN/EN61000-4-5: level 4, 2 kV line-to-neutral, criteria A. Conducted / magnetic immunity BS EN/EN61000-4-6: level 3, criteria A. BS EN/EN61000-4-8: level 4, criteria A. Voltage dips / interruptions BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is treated as an independent unit in the catalogue; the completed equipment must still be reconfirmed for compliance with the applicable EMC directives. Component-level listings do not certify the finished installation. Application and Manufacturer Information Typical applications Household control systems, building automation, industrial control, factory automation and electro-mechanical apparatus. Warranty statement The manufacturer catalogue lists a three-year warranty, subject to applicable manufacturer terms. Catalogue reference HDR-100, revision 2026-04-03, PDF pages 13–16.

  • HDR-60-48

    MEAN WELL HDR-60 series: Ultra-Slim DIN Rail Power Supply - HDR-60-48

    MEAN WELL HDR-60-48 is an ultra-slim single-output DIN rail power supply rated at 48 V DC, 1.25 A and 60 W. Its plastic housing is 52.5 mm wide (3 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-60 Datasheet (PDF) The HDR-60 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-60-48; HDR-60 catalogue revision 2026-04-03. The final code identifies the nominal 48 V output. Rated output 48 V DC / 1.25 A / 60 W; current range 0–1.25 A. Voltage adjustment 43.2–55.2 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 240 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 91% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 60 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 1.2 A at 115 VAC; 0.8 A at 230 VAC. Typical cold-start inrush 30 A at 115 VAC; 60 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 56.5–64.8 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +45°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue lists BIS IS13252 (Part 1):2010 / IEC60950-1:2005 with note 6: some models may not carry the BIS logo. Confirm the applicable model with MEAN WELL. Design reference BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 52.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-60. Width: 3 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1,2: −V; pin 3,4: +V; pin 5: AC/L; pin 6: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 190 g per unit. Complete PACKING entry: 190 g; 60 pcs / 13 kg / 0.91 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 12 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-60 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3524.8 K hours minimum, Telcordia SR-332 (Bellcore); 927.6 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-60-24

    MEAN WELL HDR-60 series: Ultra-Slim DIN Rail Power Supply - HDR-60-24

    MEAN WELL HDR-60-24 is an ultra-slim single-output DIN rail power supply rated at 24 V DC, 2.5 A and 60 W. Its plastic housing is 52.5 mm wide (3 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-60 Datasheet (PDF) The HDR-60 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-60-24; HDR-60 catalogue revision 2026-04-03. The final code identifies the nominal 24 V output. Rated output 24 V DC / 2.5 A / 60 W; current range 0–2.5 A. Voltage adjustment 21.6–29 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 150 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 90% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 60 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 1.2 A at 115 VAC; 0.8 A at 230 VAC. Typical cold-start inrush 30 A at 115 VAC; 60 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 30–36 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +45°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue lists BIS IS13252 (Part 1):2010 / IEC60950-1:2005 with note 6: some models may not carry the BIS logo. Confirm the applicable model with MEAN WELL. Design reference BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 52.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-60. Width: 3 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1,2: −V; pin 3,4: +V; pin 5: AC/L; pin 6: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 190 g per unit. Complete PACKING entry: 190 g; 60 pcs / 13 kg / 0.91 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 12 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-60 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3524.8 K hours minimum, Telcordia SR-332 (Bellcore); 927.6 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-60-15

    MEAN WELL HDR-60 series: Ultra-Slim DIN Rail Power Supply - HDR-60-15

    MEAN WELL HDR-60-15 is an ultra-slim single-output DIN rail power supply rated at 15 V DC, 4 A and 60 W. Its plastic housing is 52.5 mm wide (3 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-60 Datasheet (PDF) The HDR-60 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-60-15; HDR-60 catalogue revision 2026-04-03. The final code identifies the nominal 15 V output. Rated output 15 V DC / 4 A / 60 W; current range 0–4 A. Voltage adjustment 13.5–18 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 120 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 89% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 60 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 1.2 A at 115 VAC; 0.8 A at 230 VAC. Typical cold-start inrush 30 A at 115 VAC; 60 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 18.8–22.5 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +45°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue lists BIS IS13252 (Part 1):2010 / IEC60950-1:2005 with note 6: some models may not carry the BIS logo. Confirm the applicable model with MEAN WELL. Design reference BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 52.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-60. Width: 3 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1,2: −V; pin 3,4: +V; pin 5: AC/L; pin 6: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 190 g per unit. Complete PACKING entry: 190 g; 60 pcs / 13 kg / 0.91 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 12 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-60 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3524.8 K hours minimum, Telcordia SR-332 (Bellcore); 927.6 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-60-12

    MEAN WELL HDR-60 series: Ultra-Slim DIN Rail Power Supply - HDR-60-12

    MEAN WELL HDR-60-12 is an ultra-slim single-output DIN rail power supply rated at 12 V DC, 4.5 A and 54 W. Its plastic housing is 52.5 mm wide (3 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-60 Datasheet (PDF) The HDR-60 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-60-12; HDR-60 catalogue revision 2026-04-03. The final code identifies the nominal 12 V output. Rated output 12 V DC / 4.5 A / 54 W; current range 0–4.5 A. Voltage adjustment 10.8–13.8 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 120 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 88% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 54 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 1.2 A at 115 VAC; 0.8 A at 230 VAC. Typical cold-start inrush 30 A at 115 VAC; 60 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 14.2–16.2 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +45°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue lists BIS IS13252 (Part 1):2010 / IEC60950-1:2005 with note 6: some models may not carry the BIS logo. Confirm the applicable model with MEAN WELL. Design reference BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 52.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-60. Width: 3 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1,2: −V; pin 3,4: +V; pin 5: AC/L; pin 6: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 190 g per unit. Complete PACKING entry: 190 g; 60 pcs / 13 kg / 0.91 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 12 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-60 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3524.8 K hours minimum, Telcordia SR-332 (Bellcore); 927.6 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-60-5

    MEAN WELL HDR-60 series: Ultra-Slim DIN Rail Power Supply - HDR-60-5

    MEAN WELL HDR-60-5 is an ultra-slim single-output DIN rail power supply rated at 5 V DC, 6.5 A and 32.5 W. Its plastic housing is 52.5 mm wide (3 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-60 Datasheet (PDF) The HDR-60 section is on PDF pages 9, 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-60-5; HDR-60 catalogue revision 2026-04-03. The final code identifies the nominal 5 V output. Rated output 5 V DC / 6.5 A / 32.5 W; current range 0–6.5 A. Voltage adjustment 5.0–5.5 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 80 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 85% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 32.5 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 1.2 A at 115 VAC; 0.8 A at 230 VAC. Typical cold-start inrush 30 A at 115 VAC; 60 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 5.75–6.75 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +45°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue lists BIS IS13252 (Part 1):2010 / IEC60950-1:2005 with note 6: some models may not carry the BIS logo. Confirm the applicable model with MEAN WELL. Design reference BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 52.5 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-60. Width: 3 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1,2: −V; pin 3,4: +V; pin 5: AC/L; pin 6: AC/N. Terminal torque shown on drawing DC terminals: 5 lb-in; AC terminals: 4.5–6.0 lb-in. These values are printed on the representative label in the mechanical drawing; follow the supplied unit’s marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 190 g per unit. Complete PACKING entry: 190 g; 60 pcs / 13 kg / 0.91 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 12 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-60 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3524.8 K hours minimum, Telcordia SR-332 (Bellcore); 927.6 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.

  • HDR-30-48

    MEAN WELL HDR-30 series: Ultra-Slim DIN Rail Power Supply - HDR-30-48

    MEAN WELL HDR-30-48 is an ultra-slim single-output DIN rail power supply rated at 48 V DC, 0.75 A and 36 W. Its plastic housing is 35 mm wide (2 SU). Class II isolation, limited power source (LPS), adjustable DC output, a power-on LED and free-air convection suit household control, building automation, industrial control, factory automation and electromechanical equipment. Product Datasheet Download MEAN WELL HDR-30 Datasheet (PDF) The HDR-30 section is on PDF pages 5, 6, 7, 8. Refer to the complete mechanical drawings and notes when planning installation. Model and DC Output Complete model HDR-30-48; HDR-30 catalogue revision 2026-04-03. The final code identifies the nominal 48 V output. Rated output 48 V DC / 0.75 A / 36 W; current range 0–0.75 A. Voltage adjustment 43.2–55.2 V using the Vo Adj. control. Keep output current and power within the model ratings when adjusting voltage. Ripple and noise 240 mVp-p maximum; measured at 20 MHz bandwidth using a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1%, including setup tolerance, line regulation and load regulation. Line / load regulation ±1.0% / ±1.0%, respectively. Typical efficiency 90% at the default 230 VAC, rated-load and 25°C test conditions. The series designation is not a uniform output-power guarantee for all voltages. Use the published 36 W model rating and the input and temperature derating curves together. Input and Timing AC / DC input 85–264 VAC, with 277 VAC operational; 120–370 VDC, with 390 VDC operational. AC frequency: 47–63 Hz. Typical AC current 0.88 A at 115 VAC; 0.48 A at 230 VAC. Typical cold-start inrush 25 A at 115 VAC; 45 A at 230 VAC. Setup / rise at full load 500 / 50 ms at both 115 VAC and 230 VAC. Typical hold-up at full load 30 ms at 230 VAC; 12 ms at 115 VAC. No-load consumption Less than 0.3 W. Unless otherwise specified, the manufacturer measures parameters at 230 VAC input, rated load and 25°C ambient. Protection Short circuit / overload 105–160% of rated output power. Hiccup mode when output voltage is below 50% of rated voltage; constant-current limiting within 50–100% of rated output voltage. Both modes recover automatically after the fault is removed. Overvoltage threshold 57.6–67.2 V. Overvoltage response Shut down output voltage; re-power on to recover. Overload thresholds describe fault protection, not a permitted continuous or peak output rating. Cooling, Derating and Environment Cooling / orientation Free-air convection; the published temperature curve is for vertical mounting. Ambient temperature curve −30 to +70°C subject to derating. The curve permits 100% load from −30 to +50°C, then decreases linearly to 50% at +70°C. Input-voltage curve At 60 Hz AC, the curve shows 80% load at 85 VAC, rising to 100% at 100 VAC; the 100% plateau continues through 264 VAC and the 277 VAC operational point. Apply this limit together with the temperature limit. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C, non-condensing conditions. Operating altitude 2000 m. Overvoltage category III also applies only up to 2000 m under the listed standards. Vibration 10–500 Hz, 2G, 10 min/cycle for 60 min on each X, Y and Z axis; mounting in accordance with IEC60068-2-6. The general altitude footnote specifies an additional ambient-temperature reduction of 3.5°C per 1000 m above 2000 m for fanless supplies. It does not extend this model’s explicit 2000 m operating-altitude rating. Isolation, Safety and EMC Isolation / limited power Class II isolation and LPS (limited power source), as specified by the manufacturer. Listed approvals UL62368-1, UL508, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, IEC62368-1, EAC TP TC004 and BSMI CNS15598-1. BIS scope The catalogue explicitly excludes the 48 V model from BIS IS13252 (Part 1):2010 / IEC60950-1:2005. Design reference TUV BS EN/EN62368-1 is listed as a design reference, separately from the approved standards. Overvoltage category Category III according to EN61558, EN50178, EN60664-1 and EN62477-1, up to 2000 m. Withstand / insulation Input–output: 4 kVAC. Insulation resistance: 100 MΩ at 500 VDC, 25°C and 70% RH. EMC emissions BS EN/EN55032 (CISPR32) and CNS15936 Class B for conducted and radiated emissions. Harmonics / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. EMC immunity framework BS EN/EN55035, BS EN/EN61000-6-2 and BS EN/EN61204-3. BS EN/EN61000-4-2: level 3, 8 kV air; level 2, 4 kV contact; criterion A. BS EN/EN61000-4-3: level 3, criterion A. BS EN/EN61000-4-4: level 3, criterion A. BS EN/EN61000-4-5: level 4, 2 kV L–N, criterion A. BS EN/EN61000-4-6: level 3, criterion A. BS EN/EN61000-4-8: level 4, criterion A. BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The supply is a component of final equipment. Reconfirm EMC compliance in the completed equipment; component test results do not certify the entire system. DIN Rail Installation, Terminals and Weight Body size / case 35 × 90 × 54.5 mm (W × H × D); general drawing tolerance ±0.5 mm; case HDR-30. Width: 2 SU. Drawing clearances The side drawing also marks a 58.4 mm depth span and 63.65 / 45.15 mm step-height references. Use the full mechanical drawing for the DIN latch and connection clearances. Admissible DIN rails TS-35/7.5 or TS-35/15; the mechanical drawing identifies a 35 mm rail width. Terminal assignment pin 1: +V; pin 2: −V; pin 3: AC/L; pin 4: AC/N. Terminal torque shown on drawing Follow the supplied unit’s terminal-torque marking and installation instructions. Front controls Vo Adj. sets the output voltage; an LED indicates power on. Single-unit packing reference 130 g per unit. Complete PACKING entry: 0.13 kg; 96 pcs / 14.2 kg / 1.04 CUFT. Carton mass is not the individual-unit weight. Refer to PDF page 8 for the exact terminal numbering and rail-latch geometry. Rail compatibility does not mean a rail is included. These HDR-30 pages do not list a separately orderable MEAN WELL rail, bracket, cover or connector accessory code. Reliability and Manufacturer Information MTBF reference 3670.4 K hours minimum, Telcordia SR-332 (Bellcore); 968.1 K hours minimum, MIL-HDBK-217F at 25°C. These are calculated reliability references, not a guaranteed service life. Warranty statement The manufacturer’s catalogue lists a three-year warranty, subject to the applicable manufacturer terms.


You have seen 24 out of 31 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa