HRP,HRPG:Switching Power Supply with PFC Function

100 products

MEAN WELL HRP & HRPG Series Single Output Power Supply

Complete Portfolio: 75W to 1000W | Active PFC | 5 Years Warranty | Parallel Functions

  • Family Overview
  • HRP vs. HRPG Series
  • 75W~200W Specifications
  • 300W~1000W Specifications
  • Dimensions & Ordering

General Family Features

The MEAN WELL HRP and HRPG series represent a premium, highly reliable line of enclosed power supplies featuring active Power Factor Correction (PFC) across the entire range.

Robust & Reliable

  • All models are meticulously built using 105°C long life electrolytic capacitors.
  • They are capable of withstanding a 300VAC surge input for 5 seconds.
  • The entire product family provides peace of mind with a comprehensive 5 years warranty.

Efficient & Safe

  • They feature a Universal AC input / Full range.
  • Comprehensive protections include Short circuit / Overload / Over voltage / Over temperature.
  • Built-in remote ON-OFF control is standard.
  • A constant current limiting circuit is employed for reliable overload protection.

Understanding the HRPG "Green Power" Advantage

While the HRP series serves as a standard premium power supply, the HRPG series introduces advanced energy-saving "Green" functions designed for high-efficiency, eco-friendly systems.

  • Ultra-Low Standby Power: HRPG models (from 150W up to 600W) feature an exceptionally low no-load power consumption, typically < 0.5W to < 0.75W depending on the wattage.
  • Auxiliary Standby Output: HRPG models are exclusively equipped with a 5V@0.3A standby output. This ensures continuous power is supplied to essential control circuits even when the main output is turned off.
  • Parallel Function (Current Sharing): The high-power HRPG series is designed for scalability. The HRPG-600 supports parallel operation up to 2400W (3+1) for its 24V, 36V, and 48V models. The flagship HRPG-1000 supports parallel operation up to 4000W (3+1).

Mid-Power Specifications (75W ~ 200W)

The lower wattage ranges in this family are cooled entirely by free air convection, ensuring silent operation, and maintain a 1U low profile height of just 38mm.

Series Model HRP-75 HRP-100 HRP/HRPG-150 HRP/HRPG-200
Max Rated Power Up to 76.8W Up to 108W Up to 158.4W Up to 206.4W
DC Voltages Available 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V
Max Efficiency (Typ.) Up to 89% Up to 90% Up to 89% Up to 89%
Remote Sense N/A N/A Built-in Built-in

High-Power Specifications (300W ~ 1000W)

The higher power models utilize a built-in cooling fan with fan ON/OFF control to manage thermals effectively. Furthermore, they are equipped with a built-in remote sense function and output a DC OK signal.

Series Model HRP/HRPG-300 HRP/HRPG-450 HRP/HRPG-600 HRPG-1000
Max Rated Power Up to 336W Up to 456W Up to 648W Up to 1008W
DC Voltages Available 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V 12V, 15V, 24V, 48V
Max Efficiency (Typ.) Up to 89% Up to 89.5% Up to 89% Up to 94%
Parallel Function N/A N/A Up to 2400W (HRPG only) Up to 4000W

Dimensions & Ordering Guide

Physical Dimensions (L*W*H)

The HRP family maintains a standardized, compact form factor even at high wattages. Impressively, the 600W and 1000W models share the exact same enclosure dimensions.

  • 75W: 129 * 98 * 38 mm
  • 100W / 150W: 159 * 97 * 38 mm
  • 200W: 199 * 98 * 38 mm
  • 300W: 199 * 105 * 41 mm
  • 450W: 218 * 105 * 41 mm
  • 600W / 1000W: 218 * 105 * 63.5 mm

Product Ordering Code Breakdown

No. Item Code / Value Description
1 Series Name HRP / HRPG HRP = Standard; HRPG = Green Power (Standby function & Low no-load power)
2 Rated Wattage 75 / 100 / 150 / 200 / 300 / 450 / 600 / 1000 Approximate output power rating in Watts
3 Output Voltage 3.3 / 5 / 7.5 / 12 / 15 / 24 / 36 / 48 DC Voltage Output
Example 1: HRP-100-12 represents a standard 100W power supply with a 12V DC output.
Example 2: HRPG-600-24 represents a 600W Green power supply (with parallel capability) and a 24V DC output.
Example 3: HRPG-1000-48 represents the flagship 1000W Green power supply featuring parallel capability and a 48V DC output.
  • HRPG-150-12

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-12

    MEAN WELL HRPG-150-12 is a 156 W enclosed AC/DC power supply with a 12 V, 13 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-12 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 12: nominal 12 V main output. Model-specific rating 156 W at 12 V and 13 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 12 V Rated current 13 A Current range 0 to 13 A Rated output power 156 W Output voltage adjustment 10.2 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 87% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 14.4 to 16.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-12; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $142.93

  • HRPG-150-7.5

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-7.5

    MEAN WELL HRPG-150-7.5 is a 150 W enclosed AC/DC power supply with a 7.5 V, 20 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-7.5 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 7.5: nominal 7.5 V main output. Model-specific rating 150 W at 7.5 V and 20 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 7.5 V Rated current 20 A Current range 0 to 20 A Rated output power 150 W Output voltage adjustment 6.8 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 86% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 9.4 to 10.9 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-7.5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $147.36

  • HRPG-150-5

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-5

    MEAN WELL HRPG-150-5 is a 130 W enclosed AC/DC power supply with a 5 V, 26 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-5 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 5: nominal 5 V main output. Model-specific rating 130 W at 5 V and 26 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 5 V Rated current 26 A Current range 0 to 26 A Rated output power 130 W Output voltage adjustment 4.3 to 5.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 84% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 6 to 7 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $147.36

  • HRPG-150-3.3

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-3.3

    MEAN WELL HRPG-150-3.3 is a 99 W enclosed AC/DC power supply with a 3.3 V, 30 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-3.3 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 3.3: nominal 3.3 V main output. Model-specific rating 99 W at 3.3 V and 30 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 3.3 V Rated current 30 A Current range 0 to 30 A Rated output power 99 W Output voltage adjustment 2.8 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 78.5% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 3.96 to 4.62 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-3.3; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $147.36

  • HRP-150-48

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-48

    MEAN WELL HRP-150-48 is a 158.4 W enclosed AC/DC power supply with a 48 V, 3.3 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-48 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 48: nominal 48 V main output. Model-specific rating 158.4 W at 48 V and 3.3 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 48 V Rated current 3.3 A Current range 0 to 3.3 A Rated output power 158.4 W Output voltage adjustment 40.8 to 55.2 V Ripple and noise, maximum 240 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 57.6 to 67.2 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $126.17

  • HRP-150-36

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-36

    MEAN WELL HRP-150-36 is a 154.8 W enclosed AC/DC power supply with a 36 V, 4.3 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-36 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 36: nominal 36 V main output. Model-specific rating 154.8 W at 36 V and 4.3 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 36 V Rated current 4.3 A Current range 0 to 4.3 A Rated output power 154.8 W Output voltage adjustment 28.8 to 39.6 V Ripple and noise, maximum 200 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 41.4 to 48.6 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $126.17

  • HRP-150-24

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-24

    MEAN WELL HRP-150-24 is a 156 W enclosed AC/DC power supply with a 24 V, 6.5 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-24 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 24: nominal 24 V main output. Model-specific rating 156 W at 24 V and 6.5 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 24 V Rated current 6.5 A Current range 0 to 6.5 A Rated output power 156 W Output voltage adjustment 21.6 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 30 to 34.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $117.30

  • HRP-150-15

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-15

    MEAN WELL HRP-150-15 is a 150 W enclosed AC/DC power supply with a 15 V, 10 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-15 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 15: nominal 15 V main output. Model-specific rating 150 W at 15 V and 10 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 15 V Rated current 10 A Current range 0 to 10 A Rated output power 150 W Output voltage adjustment 13.5 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 18.8 to 21.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-15; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $126.17

  • HRP-150-12

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-12

    MEAN WELL HRP-150-12 is a 156 W enclosed AC/DC power supply with a 12 V, 13 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-12 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 12: nominal 12 V main output. Model-specific rating 156 W at 12 V and 13 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 12 V Rated current 13 A Current range 0 to 13 A Rated output power 156 W Output voltage adjustment 10.2 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 14.4 to 16.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-12; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $126.17

  • HRP-150-7.5

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-7.5

    MEAN WELL HRP-150-7.5 is a 150 W enclosed AC/DC power supply with a 7.5 V, 20 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-7.5 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 7.5: nominal 7.5 V main output. Model-specific rating 150 W at 7.5 V and 20 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 7.5 V Rated current 20 A Current range 0 to 20 A Rated output power 150 W Output voltage adjustment 6.8 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 87% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 9.4 to 10.9 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-7.5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $126.17

  • HRP-150-5

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-5

    MEAN WELL HRP-150-5 is a 130 W enclosed AC/DC power supply with a 5 V, 26 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-5 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 5: nominal 5 V main output. Model-specific rating 130 W at 5 V and 26 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 5 V Rated current 26 A Current range 0 to 26 A Rated output power 130 W Output voltage adjustment 4.3 to 5.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 85% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 6 to 7 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-5; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $126.17

  • HRP-150-3.3

    MEAN WELL HRP-150 series: Enclosed AC/DC Power Supply with Active PFC - HRP-150-3.3

    MEAN WELL HRP-150-3.3 is a 99 W enclosed AC/DC power supply with a 3.3 V, 30 A main output, active PFC and free-air convection cooling. Remote sensing is provided; full-load temperature limits differ with and without the cover. Product Datasheet Download MEAN WELL HRP-150 Datasheet (PDF) The HRP-150 section is on PDF pages 5, 6. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-150-3.3 Series HRP-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 3.3: nominal 3.3 V main output. Model-specific rating 99 W at 3.3 V and 30 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 3.3 V Rated current 30 A Current range 0 to 30 A Rated output power 99 W Output voltage adjustment 2.8 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 78.5% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 100 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 3.96 to 4.62 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pins 3 to 6 NC; leave unconnected CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote sensing is explicitly provided on pins 1 and 2. These HRP-150 pages do not specify a numerical compensation limit; do not borrow the HRPG-150 limit. Pins 3 to 6 are NC, so this connector does not provide HRPG standby or remote ON/OFF functions. Functional Scope This model provides remote sensing but has no documented 5 V standby, remote ON/OFF, DC-OK or active current-sharing function in its pin table. These functions must not be inferred from higher-power HRP/HRPG models. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -50 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1742.7K hours, Telcordia SR-332 (Bellcore); 238.9K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.61 kg (610 g); not a separately measured net weight Full packing entry 0.61 kg; 24 pcs / 15.6 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 5, 6 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRP-150-3.3; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.

    $126.17

  • HRP-100-48

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-48

    MEAN WELL HRP-100-48 is a 105.6 W enclosed AC/DC power supply with a 48 V, 2.2 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-48 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 48: nominal 48 V main output. Model-specific rating 105.6 W at 48 V and 2.2 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 48 V Rated current 2.2 A Current range 0 to 2.2 A Rated output power 105.6 W Output voltage adjustment 45.6 to 55.2 V Ripple and noise, maximum 240 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 90% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 57.6 to 67.2 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $105.96

  • HRP-100-36

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-36

    MEAN WELL HRP-100-36 is a 104.4 W enclosed AC/DC power supply with a 36 V, 2.9 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-36 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 36: nominal 36 V main output. Model-specific rating 104.4 W at 36 V and 2.9 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 36 V Rated current 2.9 A Current range 0 to 2.9 A Rated output power 104.4 W Output voltage adjustment 34.2 to 39.6 V Ripple and noise, maximum 200 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 41.4 to 48.6 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $103.50

  • HRP-100-24

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-24

    MEAN WELL HRP-100-24 is a 108 W enclosed AC/DC power supply with a 24 V, 4.5 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-24 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 24: nominal 24 V main output. Model-specific rating 108 W at 24 V and 4.5 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 24 V Rated current 4.5 A Current range 0 to 4.5 A Rated output power 108 W Output voltage adjustment 22.8 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88.5% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 30 to 34.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

  • HRP-100-15

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-15

    MEAN WELL HRP-100-15 is a 105 W enclosed AC/DC power supply with a 15 V, 7 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-15 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 15: nominal 15 V main output. Model-specific rating 105 W at 15 V and 7 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 15 V Rated current 7 A Current range 0 to 7 A Rated output power 105 W Output voltage adjustment 14.25 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.8% Efficiency, typical 88% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 18.8 to 21.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $105.96

  • HRP-100-12

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-12

    MEAN WELL HRP-100-12 is a 102 W enclosed AC/DC power supply with a 12 V, 8.5 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-12 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 12: nominal 12 V main output. Model-specific rating 102 W at 12 V and 8.5 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 12 V Rated current 8.5 A Current range 0 to 8.5 A Rated output power 102 W Output voltage adjustment 11.4 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.8% Efficiency, typical 87.5% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 14.4 to 16.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $105.96

  • HRP-100-7.5

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-7.5

    MEAN WELL HRP-100-7.5 is a 101.3 W enclosed AC/DC power supply with a 7.5 V, 13.5 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-7.5 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 7.5: nominal 7.5 V main output. Model-specific rating 101.3 W at 7.5 V and 13.5 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 7.5 V Rated current 13.5 A Current range 0 to 13.5 A Rated output power 101.3 W Output voltage adjustment 7.1 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.5% Efficiency, typical 84% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. The catalog prints 101.3 W; nominal 7.5 V x 13.5 A equals 101.25 W before rounding. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 9.4 to 10.9 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $105.96

  • HRP-100-5

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-5

    MEAN WELL HRP-100-5 is a 85 W enclosed AC/DC power supply with a 5 V, 17 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-5 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 5: nominal 5 V main output. Model-specific rating 85 W at 5 V and 17 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 5 V Rated current 17 A Current range 0 to 17 A Rated output power 85 W Output voltage adjustment 4.75 to 5.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±2.0% Efficiency, typical 83% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 6 to 7 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $103.50

  • HRP-100-3.3

    MEAN WELL HRP-100 series: Enclosed AC/DC Power Supply with Active PFC - HRP-100-3.3

    MEAN WELL HRP-100-3.3 is a 66 W enclosed AC/DC power supply with a 3.3 V, 20 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-100 Datasheet (PDF) The HRP-100 section is on PDF pages 3, 4. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-100-3.3 Series HRP-100: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 3.3: nominal 3.3 V main output. Model-specific rating 66 W at 3.3 V and 20 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 3.3 V Rated current 20 A Current range 0 to 20 A Rated output power 66 W Output voltage adjustment 3.1 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance +2.5/-3.5% Line regulation ±0.5% Load regulation ±2.0% Efficiency, typical 78% Setup / rise time 2500 ms / 100 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.98 at 115 VAC, full load Input current, typical 1.1 A at 115 VAC; 0.6 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting is specified for output voltage from 50% to 100% of rated voltage; automatic recovery after the fault is removed. No additional below-50% behavior is stated here. Over-voltage trip range 3.96 to 4.62 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 60 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -40°C to 40°C; derate linearly to 50% at 60°C. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2344.3K hours, Telcordia SR-332 (Bellcore); 295.8K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.56 kg (560 g); not a separately measured net weight Full packing entry 0.56 kg; 24 pcs / 15 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 3, 4 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $105.96

  • HRP-75-48

    MEAN WELL HRP-75 series: Enclosed AC/DC Power Supply with Active PFC - HRP-75-48

    MEAN WELL HRP-75-48 is a 76.8 W enclosed AC/DC power supply with a 48 V, 1.6 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-75 Datasheet (PDF) The HRP-75 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-75-48 Series HRP-75: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 48: nominal 48 V main output. Model-specific rating 76.8 W at 48 V and 1.6 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 48 V Rated current 1.6 A Current range 0 to 1.6 A Rated output power 76.8 W Output voltage adjustment 45 to 55.2 V Ripple and noise, maximum 240 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% Setup / rise time 1800 ms / 25 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.9 at 230 VAC; >0.95 at 115 VAC, full load Input current, typical 0.9 A at 115 VAC; 0.5 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; switches to hiccup mode when output voltage is below 50% of rated voltage. Automatic recovery after the fault is removed. Over-voltage trip range 57.6 to 67.2 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminal 4 DC output -V Terminal 5 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.03%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -20°C to 40°C; derate linearly to 30% at 70°C. The -40°C to -20°C extension is marked for 230 VAC input only, and the note permits -40°C startup at 230 VAC. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 129 x 98 x 38 mm Drawing case and tolerance Case 903D; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=5; drawing spacing 33 mm, 73.5 mm from the left fixing reference and 31 mm from the top edge Side-view threaded holes 3-M3, L=5; drawing dimensions include 32 mm offset and 77 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 122.5 x 85.5 mm; side span 120 mm Terminal-side projection 12 mm maximum, separately dimensioned from the 129 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2385.6K hours, Telcordia SR-332 (Bellcore); 352.7K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.47 kg (470 g); not a separately measured net weight Full packing entry 0.47 kg; 30 pcs / 15 kg / 0.97 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 1, 2 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. Setup time is measured at cold first start; repeated input ON/OFF operation may increase setup time.

  • HRP-75-36

    MEAN WELL HRP-75 series: Enclosed AC/DC Power Supply with Active PFC - HRP-75-36

    MEAN WELL HRP-75-36 is a 75.6 W enclosed AC/DC power supply with a 36 V, 2.1 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-75 Datasheet (PDF) The HRP-75 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-75-36 Series HRP-75: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 36: nominal 36 V main output. Model-specific rating 75.6 W at 36 V and 2.1 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 36 V Rated current 2.1 A Current range 0 to 2.1 A Rated output power 75.6 W Output voltage adjustment 32 to 39.6 V Ripple and noise, maximum 200 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% Setup / rise time 1800 ms / 25 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.9 at 230 VAC; >0.95 at 115 VAC, full load Input current, typical 0.9 A at 115 VAC; 0.5 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; switches to hiccup mode when output voltage is below 50% of rated voltage. Automatic recovery after the fault is removed. Over-voltage trip range 41.4 to 48.6 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminal 4 DC output -V Terminal 5 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.03%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -20°C to 40°C; derate linearly to 30% at 70°C. The -40°C to -20°C extension is marked for 230 VAC input only, and the note permits -40°C startup at 230 VAC. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 129 x 98 x 38 mm Drawing case and tolerance Case 903D; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=5; drawing spacing 33 mm, 73.5 mm from the left fixing reference and 31 mm from the top edge Side-view threaded holes 3-M3, L=5; drawing dimensions include 32 mm offset and 77 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 122.5 x 85.5 mm; side span 120 mm Terminal-side projection 12 mm maximum, separately dimensioned from the 129 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2385.6K hours, Telcordia SR-332 (Bellcore); 352.7K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.47 kg (470 g); not a separately measured net weight Full packing entry 0.47 kg; 30 pcs / 15 kg / 0.97 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 1, 2 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. Setup time is measured at cold first start; repeated input ON/OFF operation may increase setup time.

  • HRP-75-24

    MEAN WELL HRP-75 series: Enclosed AC/DC Power Supply with Active PFC - HRP-75-24

    MEAN WELL HRP-75-24 is a 76.8 W enclosed AC/DC power supply with a 24 V, 3.2 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-75 Datasheet (PDF) The HRP-75 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-75-24 Series HRP-75: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 24: nominal 24 V main output. Model-specific rating 76.8 W at 24 V and 3.2 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 24 V Rated current 3.2 A Current range 0 to 3.2 A Rated output power 76.8 W Output voltage adjustment 21.6 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88.5% Setup / rise time 1800 ms / 25 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.9 at 230 VAC; >0.95 at 115 VAC, full load Input current, typical 0.9 A at 115 VAC; 0.5 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; switches to hiccup mode when output voltage is below 50% of rated voltage. Automatic recovery after the fault is removed. Over-voltage trip range 30 to 34.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminal 4 DC output -V Terminal 5 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.03%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -20°C to 40°C; derate linearly to 30% at 70°C. The -40°C to -20°C extension is marked for 230 VAC input only, and the note permits -40°C startup at 230 VAC. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 129 x 98 x 38 mm Drawing case and tolerance Case 903D; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=5; drawing spacing 33 mm, 73.5 mm from the left fixing reference and 31 mm from the top edge Side-view threaded holes 3-M3, L=5; drawing dimensions include 32 mm offset and 77 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 122.5 x 85.5 mm; side span 120 mm Terminal-side projection 12 mm maximum, separately dimensioned from the 129 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2385.6K hours, Telcordia SR-332 (Bellcore); 352.7K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.47 kg (470 g); not a separately measured net weight Full packing entry 0.47 kg; 30 pcs / 15 kg / 0.97 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 1, 2 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. Setup time is measured at cold first start; repeated input ON/OFF operation may increase setup time.

  • HRP-75-15

    MEAN WELL HRP-75 series: Enclosed AC/DC Power Supply with Active PFC - HRP-75-15

    MEAN WELL HRP-75-15 is a 75 W enclosed AC/DC power supply with a 15 V, 5 A main output, active PFC and free-air convection cooling. Remote ON/OFF control is provided; over-temperature protection is an optional configuration, and the stated operating range requires derating. Product Datasheet Download MEAN WELL HRP-75 Datasheet (PDF) The HRP-75 section is on PDF pages 1, 2. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRP-75-15 Series HRP-75: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 15: nominal 15 V main output. Model-specific rating 75 W at 15 V and 5 A; use the individual rating rather than the series number. Configuration boundary No additional option suffix is present in this SKU. Optional protection must be confirmed as fitted; a feature from another HRP/HRPG power class is not implied. Main Output Nominal DC voltage 15 V Rated current 5 A Current range 0 to 5 A Rated output power 75 W Output voltage adjustment 14.2 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 1800 ms / 25 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 50 ms at 230 VAC; 20 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.9 at 230 VAC; >0.95 at 115 VAC, full load Input current, typical 0.9 A at 115 VAC; 0.5 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 65 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) No-load power consumption <0.5 W, as listed for this series Capacitor feature The series feature list specifies 105°C long-life electrolytic capacitors; this is not an ambient operating-temperature rating. Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; switches to hiccup mode when output voltage is below 50% of rated voltage. Automatic recovery after the fault is removed. Over-voltage trip range 18.8 to 21.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Optional, not assumed fitted to this unsuffixed SKU. When fitted, output shuts down and recovers automatically after temperature falls. An operating-temperature range does not confirm that optional over-temperature protection has been fitted. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminal 4 DC output -V Terminal 5 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Remote ON/OFF and Mating Connector CN100 pin 1 RC- CN100 pin 2 RC+ Power ON 0 to 0.8 V between RC+ and RC- Power OFF 4 to 10 V between RC+ and RC- CN100 connector, as printed JST B-XH or equivalent Mating housing, as printed JST XHP or equivalent Crimp contact JST SXH-001T or equivalent The catalog prints shortened B-XH and XHP identifiers; confirm the exact two-position ordering variants before procurement. A mating cable, connector kit or default jumper is not stated as included. No remote-sense terminals, standby output, DC-OK output or active current-sharing terminals are specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.03%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting: 100% load from -20°C to 40°C; derate linearly to 30% at 70°C. The -40°C to -20°C extension is marked for 230 VAC input only, and the note permits -40°C startup at 230 VAC. Low-input derating At 60 Hz, allow 80% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Dimensions and Installation Body dimensions, L x W x H 129 x 98 x 38 mm Drawing case and tolerance Case 903D; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=5; drawing spacing 33 mm, 73.5 mm from the left fixing reference and 31 mm from the top edge Side-view threaded holes 3-M3, L=5; drawing dimensions include 32 mm offset and 77 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 122.5 x 85.5 mm; side span 120 mm Terminal-side projection 12 mm maximum, separately dimensioned from the 129 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; AS/NZS62368.1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 2385.6K hours, Telcordia SR-332 (Bellcore); 352.7K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.47 kg (470 g); not a separately measured net weight Full packing entry 0.47 kg; 30 pcs / 15 kg / 0.97 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 1, 2 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. Setup time is measured at cold first start; repeated input ON/OFF operation may increase setup time.


You have seen 96 out of 100 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC