General Family Features

The MEAN WELL HRP and HRPG series represent a premium, highly reliable line of enclosed power supplies featuring active Power Factor Correction (PFC) across the entire range.

Robust & Reliable

  • All models are meticulously built using 105°C long life electrolytic capacitors.
  • They are capable of withstanding a 300VAC surge input for 5 seconds.
  • The entire product family provides peace of mind with a comprehensive 5 years warranty.

Efficient & Safe

  • They feature a Universal AC input / Full range.
  • Comprehensive protections include Short circuit / Overload / Over voltage / Over temperature.
  • Built-in remote ON-OFF control is standard.
  • A constant current limiting circuit is employed for reliable overload protection.

Understanding the HRPG "Green Power" Advantage

While the HRP series serves as a standard premium power supply, the HRPG series introduces advanced energy-saving "Green" functions designed for high-efficiency, eco-friendly systems.

  • Ultra-Low Standby Power: HRPG models (from 150W up to 600W) feature an exceptionally low no-load power consumption, typically < 0.5W to < 0.75W depending on the wattage.
  • Auxiliary Standby Output: HRPG models are exclusively equipped with a 5V@0.3A standby output. This ensures continuous power is supplied to essential control circuits even when the main output is turned off.
  • Parallel Function (Current Sharing): The high-power HRPG series is designed for scalability. The HRPG-600 supports parallel operation up to 2400W (3+1) for its 24V, 36V, and 48V models. The flagship HRPG-1000 supports parallel operation up to 4000W (3+1).

Mid-Power Specifications (75W ~ 200W)

The lower wattage ranges in this family are cooled entirely by free air convection, ensuring silent operation, and maintain a 1U low profile height of just 38mm.

Series Model HRP-75 HRP-100 HRP/HRPG-150 HRP/HRPG-200
Max Rated Power Up to 76.8W Up to 108W Up to 158.4W Up to 206.4W
DC Voltages Available 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V
Max Efficiency (Typ.) Up to 89% Up to 90% Up to 89% Up to 89%
Remote Sense N/A N/A Built-in Built-in

High-Power Specifications (300W ~ 1000W)

The higher power models utilize a built-in cooling fan with fan ON/OFF control to manage thermals effectively. Furthermore, they are equipped with a built-in remote sense function and output a DC OK signal.

Series Model HRP/HRPG-300 HRP/HRPG-450 HRP/HRPG-600 HRPG-1000
Max Rated Power Up to 336W Up to 456W Up to 648W Up to 1008W
DC Voltages Available 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V (No 7.5V) 3.3V ~ 48V 12V, 15V, 24V, 48V
Max Efficiency (Typ.) Up to 89% Up to 89.5% Up to 89% Up to 94%
Parallel Function N/A N/A Up to 2400W (HRPG only) Up to 4000W

Dimensions & Ordering Guide

Physical Dimensions (L*W*H)

The HRP family maintains a standardized, compact form factor even at high wattages. Impressively, the 600W and 1000W models share the exact same enclosure dimensions.

  • 75W: 129 * 98 * 38 mm
  • 100W / 150W: 159 * 97 * 38 mm
  • 200W: 199 * 98 * 38 mm
  • 300W: 199 * 105 * 41 mm
  • 450W: 218 * 105 * 41 mm
  • 600W / 1000W: 218 * 105 * 63.5 mm

Product Ordering Code Breakdown

No. Item Code / Value Description
1 Series Name HRP / HRPG HRP = Standard; HRPG = Green Power (Standby function & Low no-load power)
2 Rated Wattage 75 / 100 / 150 / 200 / 300 / 450 / 600 / 1000 Approximate output power rating in Watts
3 Output Voltage 3.3 / 5 / 7.5 / 12 / 15 / 24 / 36 / 48 DC Voltage Output
Example 1: HRP-100-12 represents a standard 100W power supply with a 12V DC output.
Example 2: HRPG-600-24 represents a 600W Green power supply (with parallel capability) and a 24V DC output.
Example 3: HRPG-1000-48 represents the flagship 1000W Green power supply featuring parallel capability and a 48V DC output.
  • HRP-300-12

    MEAN WELL HRP-300 series: Single-Output AC/DC Power Supply with Active PFC - HRP-300-12

    MEAN WELL HRP-300-12 is an enclosed single-output AC/DC power supply rated at 12 V, 27 A and 324 W, with active PFC and remote sensing. It uses a built-in cooling fan with ON/OFF control and provides a DC-OK output-status signal. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-300 Datasheet (PDF) The HRP-300 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-300-12 Rated DC output 12 V / 27 A / 324 W Output current range 0 to 27 A Local voltage adjustment 10.2 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRP-300 is the series designation; the final 12 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 324 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 3.5 A at 115 VAC; 1.8 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 14.4 to 16.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Built-in cooling fan with ON/OFF control Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +50°C, then declines to 50% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 5°C ambient-temperature derating per 1000 m for this fan-cooled model. This note does not establish an independent maximum operating-altitude rating. The typical fan-ON condition is load 35±15% or internal RTH2 temperature at least 50°C. RTH2 is an internal sensing point, not the ambient-temperature threshold. Preserve the fan airflow path toward the end opposite the connection terminals. Remote Sense CN100 pin 7 / pin 8 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. DC-OK Output Status DC-OK / signal return CN100 pin 3 / pin 5 GND PSU ON indication 3.3 to 5.6 V PSU OFF indication 0 to 1 V Use the dedicated DC-OK and GND connections shown in the connector table. The signal is an output-status indication, not a power output. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 DC-OK; pin 4 NC; pin 5 GND; pin 6 NC; pin 7 +S; pin 8 -S CN100 header reference HRS DF11-08DP-2DS or equivalent Mating-housing reference HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 105 × 41 mm Case / drawing tolerance 980A / ±1 mm Terminal projection / flange envelope 17 mm maximum terminal projection; 125 mm width across the mounting flanges Mounting callouts 4-M4 L=5 on the bottom and 4-M4 L=6 on each indicated side view Selected hole-centre dimensions Bottom: 120 × 75 mm; separately drawn longitudinal pitches: 168.5 and 167.5 mm Power-terminal drawing dimensions The terminal drawing labels 11 mm and 9.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.95 kg / 950 g Catalogue carton data 15 pieces / 15.3 kg / 0.83 CUFT MTBF, minimum prediction 1487.1K hours, Telcordia SR-332; 200.4K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $178.91

  • HRP-300-7.5

    MEAN WELL HRP-300 series: Single-Output AC/DC Power Supply with Active PFC - HRP-300-7.5

    MEAN WELL HRP-300-7.5 is an enclosed single-output AC/DC power supply rated at 7.5 V, 40 A and 300 W, with active PFC and remote sensing. It uses a built-in cooling fan with ON/OFF control and provides a DC-OK output-status signal. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-300 Datasheet (PDF) The HRP-300 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-300-7.5 Rated DC output 7.5 V / 40 A / 300 W Output current range 0 to 40 A Local voltage adjustment 6.8 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 86% at 230 VAC, rated load and 25°C HRP-300 is the series designation; the final 7.5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 300 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 3.5 A at 115 VAC; 1.8 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 9.4 to 10.9 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Built-in cooling fan with ON/OFF control Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +50°C, then declines to 50% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 5°C ambient-temperature derating per 1000 m for this fan-cooled model. This note does not establish an independent maximum operating-altitude rating. The typical fan-ON condition is load 35±15% or internal RTH2 temperature at least 50°C. RTH2 is an internal sensing point, not the ambient-temperature threshold. Preserve the fan airflow path toward the end opposite the connection terminals. Remote Sense CN100 pin 7 / pin 8 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. DC-OK Output Status DC-OK / signal return CN100 pin 3 / pin 5 GND PSU ON indication 3.3 to 5.6 V PSU OFF indication 0 to 1 V Use the dedicated DC-OK and GND connections shown in the connector table. The signal is an output-status indication, not a power output. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 DC-OK; pin 4 NC; pin 5 GND; pin 6 NC; pin 7 +S; pin 8 -S CN100 header reference HRS DF11-08DP-2DS or equivalent Mating-housing reference HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 105 × 41 mm Case / drawing tolerance 980A / ±1 mm Terminal projection / flange envelope 17 mm maximum terminal projection; 125 mm width across the mounting flanges Mounting callouts 4-M4 L=5 on the bottom and 4-M4 L=6 on each indicated side view Selected hole-centre dimensions Bottom: 120 × 75 mm; separately drawn longitudinal pitches: 168.5 and 167.5 mm Power-terminal drawing dimensions The terminal drawing labels 11 mm and 9.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.95 kg / 950 g Catalogue carton data 15 pieces / 15.3 kg / 0.83 CUFT MTBF, minimum prediction 1487.1K hours, Telcordia SR-332; 200.4K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $196.65

  • HRP-300-5

    MEAN WELL HRP-300 series: Single-Output AC/DC Power Supply with Active PFC - HRP-300-5

    MEAN WELL HRP-300-5 is an enclosed single-output AC/DC power supply rated at 5 V, 60 A and 300 W, with active PFC and remote sensing. It uses a built-in cooling fan with ON/OFF control and provides a DC-OK output-status signal. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-300 Datasheet (PDF) The HRP-300 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-300-5 Rated DC output 5 V / 60 A / 300 W Output current range 0 to 60 A Local voltage adjustment 4.3 to 5.8 V Ripple and noise, maximum 90 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 82% at 230 VAC, rated load and 25°C HRP-300 is the series designation; the final 5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 300 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 3.5 A at 115 VAC; 1.8 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 6 to 7 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Built-in cooling fan with ON/OFF control Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +50°C, then declines to 50% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 5°C ambient-temperature derating per 1000 m for this fan-cooled model. This note does not establish an independent maximum operating-altitude rating. The typical fan-ON condition is load 35±15% or internal RTH2 temperature at least 50°C. RTH2 is an internal sensing point, not the ambient-temperature threshold. Preserve the fan airflow path toward the end opposite the connection terminals. Remote Sense CN100 pin 7 / pin 8 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. DC-OK Output Status DC-OK / signal return CN100 pin 3 / pin 5 GND PSU ON indication 3.3 to 5.6 V PSU OFF indication 0 to 1 V Use the dedicated DC-OK and GND connections shown in the connector table. The signal is an output-status indication, not a power output. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 DC-OK; pin 4 NC; pin 5 GND; pin 6 NC; pin 7 +S; pin 8 -S CN100 header reference HRS DF11-08DP-2DS or equivalent Mating-housing reference HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 105 × 41 mm Case / drawing tolerance 980A / ±1 mm Terminal projection / flange envelope 17 mm maximum terminal projection; 125 mm width across the mounting flanges Mounting callouts 4-M4 L=5 on the bottom and 4-M4 L=6 on each indicated side view Selected hole-centre dimensions Bottom: 120 × 75 mm; separately drawn longitudinal pitches: 168.5 and 167.5 mm Power-terminal drawing dimensions The terminal drawing labels 11 mm and 9.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.95 kg / 950 g Catalogue carton data 15 pieces / 15.3 kg / 0.83 CUFT MTBF, minimum prediction 1487.1K hours, Telcordia SR-332; 200.4K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $192.21

  • HRP-300-3.3

    MEAN WELL HRP-300 series: Single-Output AC/DC Power Supply with Active PFC - HRP-300-3.3

    MEAN WELL HRP-300-3.3 is an enclosed single-output AC/DC power supply rated at 3.3 V, 60 A and 198 W, with active PFC and remote sensing. It uses a built-in cooling fan with ON/OFF control and provides a DC-OK output-status signal. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-300 Datasheet (PDF) The HRP-300 section is on PDF pages 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-300-3.3 Rated DC output 3.3 V / 60 A / 198 W Output current range 0 to 60 A Local voltage adjustment 2.8 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.5% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 80% at 230 VAC, rated load and 25°C HRP-300 is the series designation; the final 3.3 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 198 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 3.5 A at 115 VAC; 1.8 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 3.96 to 4.62 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Built-in cooling fan with ON/OFF control Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +50°C, then declines to 50% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 5°C ambient-temperature derating per 1000 m for this fan-cooled model. This note does not establish an independent maximum operating-altitude rating. The typical fan-ON condition is load 35±15% or internal RTH2 temperature at least 50°C. RTH2 is an internal sensing point, not the ambient-temperature threshold. Preserve the fan airflow path toward the end opposite the connection terminals. Remote Sense CN100 pin 7 / pin 8 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. DC-OK Output Status DC-OK / signal return CN100 pin 3 / pin 5 GND PSU ON indication 3.3 to 5.6 V PSU OFF indication 0 to 1 V Use the dedicated DC-OK and GND connections shown in the connector table. The signal is an output-status indication, not a power output. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 DC-OK; pin 4 NC; pin 5 GND; pin 6 NC; pin 7 +S; pin 8 -S CN100 header reference HRS DF11-08DP-2DS or equivalent Mating-housing reference HRS DF11-8DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 105 × 41 mm Case / drawing tolerance 980A / ±1 mm Terminal projection / flange envelope 17 mm maximum terminal projection; 125 mm width across the mounting flanges Mounting callouts 4-M4 L=5 on the bottom and 4-M4 L=6 on each indicated side view Selected hole-centre dimensions Bottom: 120 × 75 mm; separately drawn longitudinal pitches: 168.5 and 167.5 mm Power-terminal drawing dimensions The terminal drawing labels 11 mm and 9.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.95 kg / 950 g Catalogue carton data 15 pieces / 15.3 kg / 0.83 CUFT MTBF, minimum prediction 1487.1K hours, Telcordia SR-332; 200.4K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $196.65

  • HRPG-200-48

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-48

    MEAN WELL HRPG-200-48 is an enclosed single-output AC/DC power supply rated at 48 V, 4.3 A and 206.4 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-48 Rated DC output 48 V / 4.3 A / 206.4 W Output current range 0 to 4.3 A Local voltage adjustment 40.8 to 55.2 V Ripple and noise, maximum 250 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 48 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 206.4 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 57.6 to 67.2 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-36

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-36

    MEAN WELL HRPG-200-36 is an enclosed single-output AC/DC power supply rated at 36 V, 5.7 A and 205.2 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-36 Rated DC output 36 V / 5.7 A / 205.2 W Output current range 0 to 5.7 A Local voltage adjustment 28.8 to 39.6 V Ripple and noise, maximum 250 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 36 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 205.2 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 41.4 to 48.6 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-24

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-24

    MEAN WELL HRPG-200-24 is an enclosed single-output AC/DC power supply rated at 24 V, 8.4 A and 201.6 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-24 Rated DC output 24 V / 8.4 A / 201.6 W Output current range 0 to 8.4 A Local voltage adjustment 21.6 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 24 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 201.6 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 30 to 34.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $172.50

  • HRPG-200-15

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-15

    MEAN WELL HRPG-200-15 is an enclosed single-output AC/DC power supply rated at 15 V, 13.4 A and 201 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-15 Rated DC output 15 V / 13.4 A / 201 W Output current range 0 to 13.4 A Local voltage adjustment 13.5 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 15 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 201 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 18.8 to 21.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-12

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-12

    MEAN WELL HRPG-200-12 is an enclosed single-output AC/DC power supply rated at 12 V, 16.7 A and 200.4 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-12 Rated DC output 12 V / 16.7 A / 200.4 W Output current range 0 to 16.7 A Local voltage adjustment 10.2 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 12 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.4 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 14.4 to 16.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-7.5

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-7.5

    MEAN WELL HRPG-200-7.5 is an enclosed single-output AC/DC power supply rated at 7.5 V, 26.7 A and 200.3 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-7.5 Rated DC output 7.5 V / 26.7 A / 200.3 W Output current range 0 to 26.7 A Local voltage adjustment 6.8 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 86% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 7.5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.3 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 9.4 to 10.9 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-5

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-5

    MEAN WELL HRPG-200-5 is an enclosed single-output AC/DC power supply rated at 5 V, 35 A and 175 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-5 Rated DC output 5 V / 35 A / 175 W Output current range 0 to 35 A Local voltage adjustment 4.3 to 5.8 V Ripple and noise, maximum 90 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 84% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 175 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 6 to 7 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRPG-200-3.3

    MEAN WELL HRPG-200 series: Single-Output AC/DC Power Supply with Active PFC - HRPG-200-3.3

    MEAN WELL HRPG-200-3.3 is an enclosed single-output AC/DC power supply rated at 3.3 V, 40 A and 132 W, with active PFC and remote sensing. It uses free-air convection cooling. This HRPG model also includes remote ON/OFF and an independent 5 V, 0.3 A standby output. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRPG-200 Datasheet (PDF) The HRPG-200 section is on PDF pages 12, 13, 14. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRPG-200-3.3 Rated DC output 3.3 V / 40 A / 132 W Output current range 0 to 40 A Local voltage adjustment 2.8 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.5% Efficiency, typical 80% at 230 VAC, rated load and 25°C HRPG-200 is the series designation; the final 3.3 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 132 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 3.96 to 4.62 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense, ON/OFF and Standby Remote-sense connection CN100 pin 5: +S; pin 6: -S Line-drop compensation Up to 0.5 V Remote-control connection CN100 pin 1: RC+; pin 2: RC- Main output ON RC+ to RC-: 4 to 10 V, or open contact Main output OFF RC+ to RC-: 0 to 0.8 V, or shorted contact Standby output CN100 pin 3: AUX; pin 4: AUXG; 5 V, up to 0.3 A Standby accuracy / ripple 4.75 to 5.25 V (±5%); 50 mVp-p maximum ripple No-load power consumption <0.5 W when remote control holds the main output OFF at 0 to 0.8 V or short circuit Connect +S to the positive load terminal and -S to the negative load terminal, using a twisted pair to minimize noise pickup. Observe the 0.5 V compensation limit; sense leads are signal connections, not the main load-current path. The AUX standby output is not switched by the remote ON/OFF control. AUXG is its return and is isolated from the main +V/-V output. Do not confuse AUXG with other signal returns. Remote contact closed means main power OFF; open means ON. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 RC+; pin 2 RC-; pin 3 AUX; pin 4 AUXG; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1612.1K hours, Telcordia SR-332; 189.1K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $176.94

  • HRP-200-48

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-48

    MEAN WELL HRP-200-48 is an enclosed single-output AC/DC power supply rated at 48 V, 4.3 A and 206.4 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-48 Rated DC output 48 V / 4.3 A / 206.4 W Output current range 0 to 4.3 A Local voltage adjustment 40.8 to 55.2 V Ripple and noise, maximum 250 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 48 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 206.4 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 57.6 to 67.2 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $161.66

  • HRP-200-36

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-36

    MEAN WELL HRP-200-36 is an enclosed single-output AC/DC power supply rated at 36 V, 5.7 A and 205.2 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-36 Rated DC output 36 V / 5.7 A / 205.2 W Output current range 0 to 5.7 A Local voltage adjustment 28.8 to 39.6 V Ripple and noise, maximum 250 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 89% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 36 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 205.2 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 41.4 to 48.6 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $161.66

  • HRP-200-24

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-24

    MEAN WELL HRP-200-24 is an enclosed single-output AC/DC power supply rated at 24 V, 8.4 A and 201.6 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-24 Rated DC output 24 V / 8.4 A / 201.6 W Output current range 0 to 8.4 A Local voltage adjustment 21.6 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.0% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 24 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 201.6 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 30 to 34.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $150.32

  • HRP-200-15

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-15

    MEAN WELL HRP-200-15 is an enclosed single-output AC/DC power supply rated at 15 V, 13.4 A and 201 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-15 Rated DC output 15 V / 13.4 A / 201 W Output current range 0 to 13.4 A Local voltage adjustment 13.5 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 15 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 201 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 18.8 to 21.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $166.09

  • HRP-200-12

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-12

    MEAN WELL HRP-200-12 is an enclosed single-output AC/DC power supply rated at 12 V, 16.7 A and 200.4 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-12 Rated DC output 12 V / 16.7 A / 200.4 W Output current range 0 to 16.7 A Local voltage adjustment 10.2 to 13.8 V Ripple and noise, maximum 120 mVp-p Voltage tolerance ±1.0% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 88% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 12 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.4 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 14.4 to 16.8 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $161.66

  • HRP-200-7.5

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-7.5

    MEAN WELL HRP-200-7.5 is an enclosed single-output AC/DC power supply rated at 7.5 V, 26.7 A and 200.3 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-7.5 Rated DC output 7.5 V / 26.7 A / 200.3 W Output current range 0 to 26.7 A Local voltage adjustment 6.8 to 9 V Ripple and noise, maximum 100 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 86% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 7.5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 200.3 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 9.4 to 10.9 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $166.09

  • HRP-200-5

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-5

    MEAN WELL HRP-200-5 is an enclosed single-output AC/DC power supply rated at 5 V, 35 A and 175 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-5 Rated DC output 5 V / 35 A / 175 W Output current range 0 to 35 A Local voltage adjustment 4.3 to 5.8 V Ripple and noise, maximum 90 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.0% Efficiency, typical 84% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 5 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 175 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 6 to 7 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $161.66

  • HRP-200-3.3

    MEAN WELL HRP-200 series: Single-Output AC/DC Power Supply with Active PFC - HRP-200-3.3

    MEAN WELL HRP-200-3.3 is an enclosed single-output AC/DC power supply rated at 3.3 V, 40 A and 132 W, with active PFC and remote sensing. It uses free-air convection cooling. Observe the input-voltage, ambient-temperature and output limits together. Product Datasheet Download MEAN WELL HRP-200 Datasheet (PDF) The HRP-200 section is on PDF pages 10, 11. Refer to the complete mechanical drawings and notes when planning installation. Model and Rated Output Complete model HRP-200-3.3 Rated DC output 3.3 V / 40 A / 132 W Output current range 0 to 40 A Local voltage adjustment 2.8 to 3.8 V Ripple and noise, maximum 80 mVp-p Voltage tolerance ±2.0% Line regulation ±0.5% Load regulation ±1.5% Efficiency, typical 80% at 230 VAC, rated load and 25°C HRP-200 is the series designation; the final 3.3 suffix identifies the nominal output voltage. The series number is not the exact output-power rating: this model is rated 132 W. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Voltage tolerance includes set-up tolerance, line regulation and load regulation. Ripple/noise is measured at 20 MHz bandwidth with a 12-inch twisted pair terminated by 0.1 µF and 47 µF capacitors in parallel. Input and Timing Input voltage 85 to 264 VAC / 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, at full load AC current, typical 2.1 A at 115 VAC; 1.1 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1.2 mA at 240 VAC Setup / rise time 1000 / 50 ms at 230 VAC; 2500 / 50 ms at 115 VAC, at full load Hold-up time, typical 16 ms at both 230 VAC and 115 VAC, at full load The unit withstands 300 VAC input for 5 seconds; this is a short-duration condition and does not extend the continuous input range. The block diagram includes active inrush-current limiting and a 70 kHz PWM switching frequency. The 60 Hz input-derating graph shows 80% load at 85 VAC, rising to 100% at 100 VAC; full load continues through 264 VAC. Follow the drawn segment between these points and apply temperature derating as well. Protection Protection functions Short circuit, overload, overvoltage and overtemperature Overload 105 to 135% of rated output power; constant-current limiting with automatic recovery after the fault is removed Overvoltage threshold 3.96 to 4.62 V Overvoltage response Output shuts down; re-power to recover Overtemperature response Output shuts down; automatic recovery after the temperature goes down The overload threshold is a protection setting, not permission for continuous overload or a separate peak-power rating. Cooling and Operating Conditions Cooling Free-air convection; fanless Working ambient temperature -40 to +70°C with load derating Working humidity 20 to 90% RH, non-condensing Storage temperature / humidity -40 to +85°C / 10 to 95% RH Temperature coefficient ±0.03%/°C from 0 to 50°C Vibration 10 to 500 Hz, 5G; 10 minutes/cycle, 60 minutes each along X, Y and Z The horizontal-installation thermal curve permits 100% load from -40°C to +40°C, then declines to 40% at +70°C. The highest working temperature is a reduced-load condition. For operation above 2000 m, apply an additional 3.5°C ambient-temperature derating per 1000 m for this fanless model. This note does not establish an independent maximum operating-altitude rating. Remote Sense CN100 pin 5 / pin 6 +S / -S Built-in positive and negative remote-sense connections are identified in the mechanical and block diagrams. Use the matching +S and -S polarity for the load-sensing circuit and keep signal wiring distinct from the main power wiring. Terminals and Connector Selection Power terminals 1 AC/L; 2 AC/N; 3 FG; 4–5 DC -V; 6–7 DC +V CN100 signal assignment pin 1 NC; pin 2 NC; pin 3 NC; pin 4 NC; pin 5 +S; pin 6 -S CN100 header reference HRS DF11-6DP-2DS or equivalent Mating-housing reference HRS DF11-6DS or equivalent Contact reference HRS DF11-**SC or equivalent Retain the printed connector identifiers when selecting compatible parts. The ** in HRS DF11-**SC is a family placeholder, not a complete contact order code; choose the exact contact and wire-size variant from the connector manufacturer before ordering. Do not add an unprinted suffix. The connector table does not establish that mating housings, contacts, cables, brackets or mounting screws are included. No separate MEAN WELL accessory order code is listed in these model pages. NC denotes an unassigned pin; keep it unconnected. Dimensions and Installation Body dimensions, L × W × H 199 × 98 × 38 mm Case / drawing tolerance 902E / ±1 mm Terminal projection 13 mm maximum, as dimensioned Mounting callouts 4-M3 L=5 and 3-M3 L=5 at the indicated groups Selected hole-centre dimensions Bottom: 120 × 80 mm; side longitudinal pitch: 151 mm; end mounting-hole pitch: 190 mm Power-terminal drawing dimensions The terminal drawing labels 9.5 mm and 8.2 mm; follow the drawing for their exact locations. Use the linked mechanical drawing for the complete pattern and connection clearances. L values are the thread-depth annotations for the indicated holes; the callouts are not quantities of supplied screws or separate accessory codes. Allow for mounting-surface thickness when selecting screws. The mechanical drawing identifies the local voltage-adjustment control and LED. Keep line, neutral, protective/frame ground, DC power and low-level signal connections distinct. Safety, EMC and Integration Approved standards listed for this model UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004; AS/NZS62368.1 Withstand voltage Input-output 3 kVAC; input-FG 2 kVAC; output-FG 0.5 kVAC Insulation resistance 100 MΩ at 500 VDC, 25°C and 70% RH, across input-output, input-FG and output-FG EMC emission: BS EN/EN55032 (CISPR32), Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020. EMC immunity: BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; heavy-industry level; EAC TP TC 020. This supply is a component for installation in final equipment. EMC testing used a 360 × 360 × 1 mm metal plate. The completed equipment must be rechecked for compliance; the component standards do not automatically certify the finished assembly. Weight, Reliability and Catalogue Reference Catalogue packing reference per unit 0.77 kg / 770 g Catalogue carton data 18 pieces / 14.9 kg / 0.87 CUFT MTBF, minimum prediction 1830.6K hours, Telcordia SR-332; 209.5K hours, MIL-HDBK-217F at 25°C Manufacturer warranty statement 5 years, as listed for this series Printed datasheet revision 2026-04-03 The per-unit mass is the catalogue PACKING reference, not a measured net or shipped-parcel weight. Carton totals must not be used as the individual product weight. MTBF is a statistical reliability prediction, not a guaranteed service life.

    $166.09

  • HRPG-150-48

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-48

    MEAN WELL HRPG-150-48 is a 158.4 W enclosed AC/DC power supply with a 48 V, 3.3 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-48 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 48: nominal 48 V main output. Model-specific rating 158.4 W at 48 V and 3.3 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 48 V Rated current 3.3 A Current range 0 to 3.3 A Rated output power 158.4 W Output voltage adjustment 40.8 to 55.2 V Ripple and noise, maximum 240 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 57.6 to 67.2 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $142.93

  • HRPG-150-36

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-36

    MEAN WELL HRPG-150-36 is a 154.8 W enclosed AC/DC power supply with a 36 V, 4.3 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-36 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 36: nominal 36 V main output. Model-specific rating 154.8 W at 36 V and 4.3 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 36 V Rated current 4.3 A Current range 0 to 4.3 A Rated output power 154.8 W Output voltage adjustment 28.8 to 39.6 V Ripple and noise, maximum 200 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 88% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 41.4 to 48.6 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $147.36

  • HRPG-150-24

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-24

    MEAN WELL HRPG-150-24 is a 156 W enclosed AC/DC power supply with a 24 V, 6.5 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-24 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 24: nominal 24 V main output. Model-specific rating 156 W at 24 V and 6.5 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 24 V Rated current 6.5 A Current range 0 to 6.5 A Rated output power 156 W Output voltage adjustment 21.6 to 28.8 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.2% Load regulation ±0.5% Efficiency, typical 87% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 30 to 34.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve.

    $142.93

  • HRPG-150-15

    MEAN WELL HRPG-150 series: Enclosed AC/DC Power Supply with Active PFC - HRPG-150-15

    MEAN WELL HRPG-150-15 is a 150 W enclosed AC/DC power supply with a 15 V, 10 A main output, active PFC and free-air convection cooling. It adds remote sensing, remote ON/OFF control and an independent 5 V standby output; apply the cover, low-temperature and input-voltage derating conditions below. Product Datasheet Download MEAN WELL HRPG-150 Datasheet (PDF) The HRPG-150 section is on PDF pages 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Configuration Complete model HRPG-150-15 Series HRPG-150: single-output AC/DC power supply with active PFC. The series power number is not this model's guaranteed output wattage. Output-voltage code 15: nominal 15 V main output. Model-specific rating 150 W at 15 V and 10 A; use the individual rating rather than the series number. HRPG functional scope This HRPG-150 model includes remote sensing, remote ON/OFF and 5 V standby. Do not substitute HRP-150 pin assignments. Main Output Nominal DC voltage 15 V Rated current 10 A Current range 0 to 10 A Rated output power 150 W Output voltage adjustment 13.5 to 18 V Ripple and noise, maximum 150 mVp-p Voltage tolerance ±1.5% Line regulation ±0.3% Load regulation ±0.5% Efficiency, typical 87% Setup / rise time 3000 ms / 50 ms at both 230 VAC and 115 VAC, full load Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load Voltage tolerance includes setup tolerance, line regulation and load regulation. Ripple/noise is measured with 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 uF and 47 uF capacitors in parallel. Input and Power Conversion Input range 85 to 264 VAC, universal full range; 120 to 370 VDC AC frequency 47 to 63 Hz Power factor, typical >0.95 at 230 VAC; >0.99 at 115 VAC, full load Input current, typical 1.7 A at 115 VAC; 0.9 A at 230 VAC Inrush current, typical 35 A at 115 VAC; 70 A at 230 VAC Leakage current <1 mA at 240 VAC Short-duration input withstand 300 VAC for 5 seconds; this is not the continuous input range PFC and inrush limiting Built-in active PFC and active inrush-current limiting (block diagram) PWM switching frequency 70 kHz for this output-voltage branch Protection Short circuit / overload 105% to 135% of rated output power. Constant-current limiting; automatic recovery after the fault is removed. Over-voltage trip range 18.8 to 21.8 V Over-voltage recovery Output shuts down; remove and restore input power to recover. Over-temperature protection Output shuts down and recovers automatically after temperature falls. Power Connections Terminal 1 AC/L Terminal 2 AC/N Terminal 3 FG / protective earth Terminals 4 and 5 DC output -V Terminals 6 and 7 DC output +V Follow the polarity and protective-earth assignments in the model-specific mechanical drawing. Signal connectors are not mains-input terminals. Signal Connector and Mating Parts CN100 pin 1 -S: negative remote sense CN100 pin 2 +S: positive remote sense CN100 pin 3 AUXG: isolated auxiliary-output return CN100 pin 4 AUX: 5 V standby output, referenced to pin 3 CN100 pin 5 RC-: remote-control ground CN100 pin 6 RC+: remote ON/OFF input, referenced to pin 5 CN100 connector HRS DF11-6DP-2DSA or equivalent Mating housing HRS DF11-6DS or equivalent Mating contact family, as printed HRS DF11-**SC or equivalent The DF11-**SC wildcard is not a complete purchasable contact code. Select the exact contact variant for the actual wire and connector system; the catalog does not specify an included mating harness or quantity. Remote Sense, Standby and ON/OFF Remote-sense wiring Connect pin 1 (-S) to the negative load terminal and pin 2 (+S) to the positive load terminal; twist the sense wires as a pair. Maximum sense compensation 0.5 V line drop Standby output 5 V at up to 0.3 A; tolerance ±5%; ripple 50 mVp-p maximum Standby voltage range 4.75 to 5.25 V, referenced to AUXG (pin 3) Standby isolation and availability AUXG is isolated from the main +V and -V terminals. The standby output is not controlled by remote ON/OFF. Main output ON RC+ / RC- at 4 to 10 V, or an open contact between CN100 pins 6 and 5 Main output OFF RC+ / RC- at 0 to 0.8 V, or a shorted contact between CN100 pins 6 and 5 No-load power consumption <0.5 W when RC- and RC+ (pins 5 and 6) are at 0 to 0.8 V or shorted The shorted contact switches the main output OFF; open switches it ON. Do not use the opposite HRP-75/100 remote-control logic. No DC-OK signal or active current-sharing function is specified for this model in these pages. Environment and Derating Cooling Free-air convection; fanless, 1U low-profile construction Working ambient temperature -40 to 70 °C; use the derating conditions below Working humidity 20% to 90% RH, non-condensing Storage temperature / humidity -40 to 85 °C; 10% to 95% RH Temperature coefficient ±0.04%/°C over 0°C to 50°C Vibration test 10 to 500 Hz, 5 G, 10 minutes per cycle, 60 minutes each along X, Y and Z Thermal derating Horizontal mounting with cover: 100% load through 40°C, then derate to 50% at 60°C. Without cover: 100% load through 50°C, then derate to 50% at 70°C. The 70°C endpoint is not the covered-unit limit. Low-input derating At 60 Hz, allow 75% load at 85 VAC, rising to 100% at 100 VAC; 100% is plotted from 100 to 264 VAC, subject also to thermal limits. Above 2000 m altitude Reduce permitted ambient temperature by 3.5°C per 1000 m for these fanless models. No maximum operating altitude is stated in these pages. Low-temperature standby loading In the shaded -40°C to -20°C region, the 5 V standby output must carry a minimum load of 0.03 A. Dimensions and Installation Body dimensions, L x W x H 159 x 97 x 38 mm Drawing case and tolerance Case 901I; dimensions in mm, tolerance ±1 mm Voltage adjustment SVR1 is identified in the mechanical drawing; stay within the model-specific adjustment range. Base-view threaded holes 2-M3, L=4; drawing dimensions 24 mm offset, 78 mm spacing and 65 mm from the top edge Side-view threaded holes 6-M3 (both sides), L=6; drawing dimensions include 22 mm offset and 117 mm spacing Other mounting references 3.5 mm through-hole / slot references; base fixing span 152.5 x 84.5 mm; side span 150 mm Terminal-side projection 10 mm maximum, separately dimensioned from the 159 mm body length The stated M3 L values belong to the indicated mounting locations; do not substitute the depth for another face. The catalog does not state terminal tightening torque, wire gauge, clearance distances or a separately orderable mounting kit. Use the original drawing for the full mounting layout. Safety, EMC and Reliability Safety standards UL62368-1; TUV BS EN/EN62368-1; EAC TP TC 004, as listed for this series. Dielectric withstand Input-output: 3 kVAC; input-FG: 2 kVAC; output-FG: 0.5 kVAC Isolation resistance 100 MΩ between input-output, input-FG and output-FG; measured at 500 VDC, 25°C and 70% RH EMC emission BS EN/EN55032 (CISPR32) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC 020 EMC immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN55035; BS EN/EN61000-6-2, heavy-industry level; EAC TP TC 020 MTBF, minimum 1544.0K hours, Telcordia SR-332 (Bellcore); 213.4K hours, MIL-HDBK-217F at 25°C This power supply is a component for installation in final equipment. EMC tests used a 360 x 360 mm metal plate, 1 mm thick; verify the finished equipment against the applicable EMC requirements. MTBF is a statistical reliability figure, not a service-life or warranty promise. Weight Reference and Manufacturer Notes Per-unit catalog packing reference 0.63 kg (630 g); not a separately measured net weight Full packing entry 0.63 kg; 24 pcs / 16 kg / 0.9 CUFT Manufacturer warranty statement The series datasheet lists 5 years warranty; this does not add a separate seller warranty or delivery commitment. Catalog revision / pages 2026-04-03; PDF pages 7, 8, 9 Unless otherwise stated, parameters are measured at 230 VAC input, rated load and 25°C ambient. Keep the thermal and input-voltage derating limits together; the nominal output rating does not override either curve. The manufacturer strongly recommends that external output capacitance not exceed 5000 uF for HRPG-150-15; this limit is specifically stated for the 3.3 V, 5 V, 7.5 V, 12 V and 15 V versions.