PWM Series, SPWM Series: PWM Output LED Driver (Constant Voltage)

55 products

MEAN WELL PWM & SPWM Series LED Drivers

MEAN WELL PWM & SPWM Series LED Power Supplies

  • Series Overview
  • Technical Specifications
  • Power Range & Models
  • Smart Control Protocols

Series Overview & Core Features

The PWM and SPWM series are dedicated Constant Voltage (CV) LED drivers that output a high-frequency Pulse Width Modulation (PWM) style voltage. This unique architecture is specifically designed to guarantee color temperature accuracy and brightness uniformity across parallel LED strips, even at extremely low dimming levels.

  • PWM Series (Standard & Smart): The foundational lineup featuring high-frequency dimming (up to 4kHz) to eliminate visible flicker and meet strict IEEE-1789 health standards. It is available in standard analog dimming as well as digital protocols.
  • SPWM Series (Next-Gen Smart): The next evolution of PWM drivers focusing heavily on flawless deep dimming (down to 0.1% ~ 1%) and cutting-edge encrypted native protocols (like KNX Data Secure).
  • IP67 & Class II Design: Both series are fully encapsulated in flame-retardant plastic housings (IP67) with no earth pin (Class II), ensuring safe installation in damp, wet, or indoor architectural locations.
  • Active PFC: Built-in active Power Factor Correction guarantees high energy efficiency and global regulatory compliance.

Technical Specifications

Parameter Specification Detail
Input Voltage 90 ~ 305VAC (Universal) / 100 ~ 305VAC (SPWM)
Output Mode Constant Voltage (CV) - PWM Style Output
IP Rating IP67 (Fully potted)
Dimming Range Deep dimming capability (SPWM reaches 0.1% ~ 1%)
Protections Short circuit / Overload / Over voltage / Over temperature
Safety Standards UL8750, ENEC, CE, CB, UKCA, EAC, KNX

Series Power Range & Availability

Select the series based on your required wattage and smart integration needs. Typical output voltages include 12V, 24V, 36V, and 48V.

Product Branch Available Wattages Core Characteristic
Standard PWM 40W, 60W, 90W, 120W, 200W Standard 3-in-1 dimming or DALI-2 control.
PWM-KN (KNX) 60W, 120W, 200W Integrated KNX protocol. Connects directly to the KNX bus.
PWM-IoT (Bluetooth) 120W, 200W Wireless Bluetooth Mesh control via smartphones.
SPWM (Smart PWM) 120W Next-gen deep dimming with advanced secure protocols.
Application Tip: The PWM and SPWM architectures are the absolute best choice for architectural cove lighting, LED tape lighting, and decorative installations where dead spots or color shifting at low dimming levels are unacceptable.

Smart Integration & Dimming Protocols

To ensure compatibility with your building's control system, select the appropriate model suffix. By embedding the control module directly into the driver, these units eliminate the need for external gateways.

Control Protocol / Suffix Features & Best Usage
Blank
(e.g., PWM-120-24)
3-in-1 Dimming (0~10V, PWM signal, or Resistance). Ideal for traditional commercial dimming systems and wall sliders.
DA / DA2
(e.g., PWM-120-24DA2)
DALI / DALI-2. The latest standard in digital lighting control, offering two-way communication for advanced lighting networks in modern office buildings.
KN / KNX Data Secure
(e.g., SPWM-120-24KN)
KNX Protocol. Direct integration into KNX building automation. The SPWM series offers KNX Data Secure, an encrypted version preventing unauthorized access in secure commercial and hotel networks.
BLE / TY1 / SVA
(IoT Bluetooth Mesh)
Wireless Mesh Networking. Programmable via Casambi (BLE), Tuya (TY1), or Silvair (SVA) smartphone apps. Perfect for retrofitting existing spaces without running new control wires.
Selection Note: The IoT models allow you to control LED strips directly from a wireless wall switch or mobile device, making them incredibly versatile for high-end residential upgrades and rapid commercial deployments.
  • PWM-200-48DA2

    MEAN WELL PWM-200 series: DALI-2 PWM output LED driver - PWM-200-48DA2

    MEAN WELL PWM-200-48DA2 MEAN WELL PWM-200-48DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 48 V LED strips, rated 4.17 A and 200.1 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-48DA2 Series and function code PWM-200; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 48 V Rated output current 4.17 A Rated output power 200.1 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 and primary-side PUSH Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 94% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 53–65 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. Use the specified DALI-2 installation wiring. PUSH wiring Primary-side PUSH: connect the push button only between DA+ and AC/L; DA− connects to AC/N as shown in the diagram. Connecting the button to AC/N instead of AC/L causes a short circuit. PUSH timing and limits Factory brightness 100%. Short push 0.1–1 s: on/off. Long push 1.5–10 s: dim up/down, reversing direction on each long push. Push >11 s: reset to 100%; <0.05 s has no effect. Up to 10 drivers per common push button; maximum cable length to last driver 20 m. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: SJOW 17 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification or a PUSH terminal rating. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $141.94

  • PWM-200-36DA2

    MEAN WELL PWM-200 series: DALI-2 PWM output LED driver - PWM-200-36DA2

    MEAN WELL PWM-200-36DA2 MEAN WELL PWM-200-36DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 36 V LED strips, rated 5.55 A and 199.8 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-36DA2 Series and function code PWM-200; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 36 V Rated output current 5.55 A Rated output power 199.8 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 and primary-side PUSH Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 94% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 41–49 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. Use the specified DALI-2 installation wiring. PUSH wiring Primary-side PUSH: connect the push button only between DA+ and AC/L; DA− connects to AC/N as shown in the diagram. Connecting the button to AC/N instead of AC/L causes a short circuit. PUSH timing and limits Factory brightness 100%. Short push 0.1–1 s: on/off. Long push 1.5–10 s: dim up/down, reversing direction on each long push. Push >11 s: reset to 100%; <0.05 s has no effect. Up to 10 drivers per common push button; maximum cable length to last driver 20 m. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: SJOW 17 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification or a PUSH terminal rating. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $141.94

  • PWM-200-24DA2

    MEAN WELL PWM-200 series: DALI-2 PWM output LED driver - PWM-200-24DA2

    MEAN WELL PWM-200-24DA2 MEAN WELL PWM-200-24DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 8.3 A and 199.2 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-24DA2 Series and function code PWM-200; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 8.3 A Rated output power 199.2 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 and primary-side PUSH Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 93% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 27–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. Use the specified DALI-2 installation wiring. PUSH wiring Primary-side PUSH: connect the push button only between DA+ and AC/L; DA− connects to AC/N as shown in the diagram. Connecting the button to AC/N instead of AC/L causes a short circuit. PUSH timing and limits Factory brightness 100%. Short push 0.1–1 s: on/off. Long push 1.5–10 s: dim up/down, reversing direction on each long push. Push >11 s: reset to 100%; <0.05 s has no effect. Up to 10 drivers per common push button; maximum cable length to last driver 20 m. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: SJOW 17 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification or a PUSH terminal rating. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $141.94

  • PWM-200-12DA2

    MEAN WELL PWM-200 series: DALI-2 PWM output LED driver - PWM-200-12DA2

    MEAN WELL PWM-200-12DA2 MEAN WELL PWM-200-12DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 15 A and 180 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-12DA2 Series and function code PWM-200; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 15 A Rated output power 180 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 and primary-side PUSH Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 92% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 13–18 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. Use the specified DALI-2 installation wiring. PUSH wiring Primary-side PUSH: connect the push button only between DA+ and AC/L; DA− connects to AC/N as shown in the diagram. Connecting the button to AC/N instead of AC/L causes a short circuit. PUSH timing and limits Factory brightness 100%. Short push 0.1–1 s: on/off. Long push 1.5–10 s: dim up/down, reversing direction on each long push. Push >11 s: reset to 100%; <0.05 s has no effect. Up to 10 drivers per common push button; maximum cable length to last driver 20 m. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 14 AWG × 2C, 300 ±20 mm. Control: SJOW 17 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification or a PUSH terminal rating. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $141.94

  • PWM-200-48

    MEAN WELL PWM-200 series: 3-in-1 dimmable PWM output LED driver - PWM-200-48

    MEAN WELL PWM-200-48 MEAN WELL PWM-200-48 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 48 V LED strips, rated 4.17 A and 200.1 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-48 Series and function code PWM-200; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 48 V Rated output current 4.17 A Rated output power 200.1 W Output PWM frequency 4 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 1% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 94% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 53–65 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: UL2464 20 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Control-wire insulation The standalone control conductors are smaller than 18 AWG: use an SELV controller or network. Consult MEAN WELL for assistance before a FELV application. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Dimming isolation This Blank version is described as an isolated 3-in-1 dimming design. Its 4 kHz output design is stated to comply with IEEE1789-2015. Do not infer unlimited system isolation or a different wiring method. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $128.64

  • PWM-200-36

    MEAN WELL PWM-200 series: 3-in-1 dimmable PWM output LED driver - PWM-200-36

    MEAN WELL PWM-200-36 MEAN WELL PWM-200-36 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 36 V LED strips, rated 5.55 A and 199.8 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-36 Series and function code PWM-200; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 36 V Rated output current 5.55 A Rated output power 199.8 W Output PWM frequency 4 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 1% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 94% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 41–49 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: UL2464 20 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Control-wire insulation The standalone control conductors are smaller than 18 AWG: use an SELV controller or network. Consult MEAN WELL for assistance before a FELV application. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Dimming isolation This Blank version is described as an isolated 3-in-1 dimming design. Its 4 kHz output design is stated to comply with IEEE1789-2015. Do not infer unlimited system isolation or a different wiring method. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $128.64

  • PWM-200-24

    MEAN WELL PWM-200 series: 3-in-1 dimmable PWM output LED driver - PWM-200-24

    MEAN WELL PWM-200-24 MEAN WELL PWM-200-24 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 8.3 A and 199.2 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-24 Series and function code PWM-200; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 8.3 A Rated output power 199.2 W Output PWM frequency 4 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 1% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 93% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 27–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 ±20 mm. Control: UL2464 20 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Control-wire insulation The standalone control conductors are smaller than 18 AWG: use an SELV controller or network. Consult MEAN WELL for assistance before a FELV application. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Dimming isolation This Blank version is described as an isolated 3-in-1 dimming design. Its 4 kHz output design is stated to comply with IEEE1789-2015. Do not infer unlimited system isolation or a different wiring method. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $128.64

  • PWM-200-12

    MEAN WELL PWM-200 series: 3-in-1 dimmable PWM output LED driver - PWM-200-12

    MEAN WELL PWM-200-12 MEAN WELL PWM-200-12 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 15 A and 180 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-200 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 60–67; specifications on page 61. Model, output and control Parameter Specification Model PWM-200-12 Series and function code PWM-200; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 15 A Rated output power 180 W Output PWM frequency 4 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 1% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 100–305 VAC or 142–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 92% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.94 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 2.2 A / 115 VAC; 1.1 A / 230 VAC; 0.9 A / 277 VAC Inrush current Cold start: 65 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 5 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.75 mA at 277 VAC No-load or standby power <0.5 W with dimming off. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 10 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–135% of rated output; Hiccup or constant-current limiting, with automatic recovery after fault removal. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 13–18 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. At 110 VAC: 100% through +40°C ambient, falling to 40% at +70°C. At 230 VAC: 100% through +45°C, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 100 VAC, rising to 100% at 110 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2235.6 / 178.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Emergency-lighting scope Catalog lists suitability according to BS EN/EN61347-2-13 Appendix J; verify the complete emergency-lighting installation. Dimensions and installation Parameter Specification Dimensions 195 × 68 × 39.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 2 × 1.0 mm², 300 mm. LED output: SJOW 14 AWG × 2C, 300 ±20 mm. Control: UL2464 20 AWG × 2C, 350 ±20 mm. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Tc1 is the 110 VAC case-temperature point; Tc2 is for 230 VAC. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Control-wire insulation The standalone control conductors are smaller than 18 AWG: use an SELV controller or network. Consult MEAN WELL for assistance before a FELV application. Application restrictions Capacitive loads are not recommended. To meet the stated ErP condition for lighting fixtures, use this supply behind a switch; do not connect it permanently to the mains. Dimming isolation This Blank version is described as an isolated 3-in-1 dimming design. Its 4 kHz output design is stated to comply with IEEE1789-2015. Do not infer unlimited system isolation or a different wiring method. Weight 1030 g; catalog packing reference per unit (1.03 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $128.64

  • PWM-120-24DA2

    MEAN WELL PWM-120 series: DALI-2 PWM output LED driver - PWM-120-24DA2

    MEAN WELL PWM-120-24DA2 MEAN WELL PWM-120-24DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 5 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-24DA2 Series and function code PWM-120; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 5 A Rated output power 120 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W standby. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +45°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–45°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope This DA2 version is listed for BS EN/EN61347-2-13 Appendix J emergency installations (EL), with AC input 100–240 VAC. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V brown, −V blue (DA/DA2 mechanical drawing). Control: DA+ purple, DA− pink. Cable specification Input and LED output: SJOW 17 AWG × 2C & H05RN-F 1.0 mm². Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $117.79

  • PWM-120-12DA2

    MEAN WELL PWM-120 series: DALI-2 PWM output LED driver - PWM-120-12DA2

    MEAN WELL PWM-120-12DA2 MEAN WELL PWM-120-12DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 10 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-12DA2 Series and function code PWM-120; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 10 A Rated output power 120 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 88.5% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W standby. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 15–17 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +40°C ambient, falling to 40% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–40°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope This DA2 version is listed for BS EN/EN61347-2-13 Appendix J emergency installations (EL), with AC input 100–240 VAC. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V brown, −V blue (DA/DA2 mechanical drawing). Control: DA+ purple, DA− pink. Cable specification Input and LED output: SJOW 17 AWG × 2C & H05RN-F 1.0 mm². Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $117.79

  • PWM-120-24DA

    MEAN WELL PWM-120 series: DALI PWM output LED driver - PWM-120-24DA

    MEAN WELL PWM-120-24DA MEAN WELL PWM-120-24DA is a DALI constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 5 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-24DA Series and function code PWM-120; DA: DALI control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 5 A Rated output power 120 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface DALI DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W standby. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +45°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–45°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA version. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V brown, −V blue (DA/DA2 mechanical drawing). Control: DA+ purple, DA− pink. Cable specification Input and LED output: SJOW 17 AWG × 2C & H05RN-F 1.0 mm². Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $130.61

  • PWM-120-12DA

    MEAN WELL PWM-120 series: DALI PWM output LED driver - PWM-120-12DA

    MEAN WELL PWM-120-12DA MEAN WELL PWM-120-12DA is a DALI constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 10 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-12DA Series and function code PWM-120; DA: DALI control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 10 A Rated output power 120 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface DALI DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 88.5% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W standby. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 15–17 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +40°C ambient, falling to 40% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–40°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. Safety, insulation and compliance Parameter Specification Safety and design standards CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA version. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V brown, −V blue (DA/DA2 mechanical drawing). Control: DA+ purple, DA− pink. Cable specification Input and LED output: SJOW 17 AWG × 2C & H05RN-F 1.0 mm². Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $130.61

  • PWM-120-48

    MEAN WELL PWM-120 series: 3-in-1 dimmable PWM output LED driver - PWM-120-48

    MEAN WELL PWM-120-48 MEAN WELL PWM-120-48 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 48 V LED strips, rated 2.5 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-48 Series and function code PWM-120; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 48 V Rated output current 2.5 A Rated output power 120 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 54–60 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +45°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–45°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 14 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $105.47

  • PWM-120-36

    MEAN WELL PWM-120 series: 3-in-1 dimmable PWM output LED driver - PWM-120-36

    MEAN WELL PWM-120-36 MEAN WELL PWM-120-36 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 36 V LED strips, rated 3.4 A and 122.4 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-36 Series and function code PWM-120; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 36 V Rated output current 3.4 A Rated output power 122.4 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 41–46 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +45°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–45°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 14 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $105.47

  • PWM-120-24

    MEAN WELL PWM-120 series: 3-in-1 dimmable PWM output LED driver - PWM-120-24

    MEAN WELL PWM-120-24 MEAN WELL PWM-120-24 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 5 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-24 Series and function code PWM-120; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 5 A Rated output power 120 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +45°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–45°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 14 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $105.47

  • PWM-120-12

    MEAN WELL PWM-120 series: 3-in-1 dimmable PWM output LED driver - PWM-120-12

    MEAN WELL PWM-120-12 MEAN WELL PWM-120-12 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 10 A and 120 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-120 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 52–59; specifications on page 53. Model, output and control Parameter Specification Model PWM-120-12 Series and function code PWM-120; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 10 A Rated output power 120 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 88.5% at the catalog test conditions Typical power factor >0.97 / 115 VAC; >0.96 / 230 VAC; >0.93 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 1.3 A / 115 VAC; 0.65 A / 230 VAC; 0.55 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 520 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 4 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 15–17 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +90°C; maximum case temperature +90°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +40°C ambient, falling to 40% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +90°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–40°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 Type HL; CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2243.7 / 228.7 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 191 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 14 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 970 g; catalog packing reference per unit (0.97 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $105.47

  • PWM-90-48DA2

    MEAN WELL PWM-90 series: DALI-2 PWM output LED driver - PWM-90-48DA2

    MEAN WELL PWM-90-48DA2 MEAN WELL PWM-90-48DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 48 V LED strips, rated 1.88 A and 90.24 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-48DA2 Series and function code PWM-90; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 48 V Rated output current 1.88 A Rated output power 90.24 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 54–60 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. DALI polarity The DA/DA2 DALI pair is polarity-insensitive; the wire labels do not imply a polar DC output. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope This DA2 version is listed for BS EN/EN61347-2-13 Appendix J emergency installations (EL), with AC input 100–240 VAC. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 1.0 mm²; LED output: the same cable designation. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $104.49

  • PWM-90-24DA2

    MEAN WELL PWM-90 series: DALI-2 PWM output LED driver - PWM-90-24DA2

    MEAN WELL PWM-90-24DA2 MEAN WELL PWM-90-24DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 3.75 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-24DA2 Series and function code PWM-90; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 3.75 A Rated output power 90 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. DALI polarity The DA/DA2 DALI pair is polarity-insensitive; the wire labels do not imply a polar DC output. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope This DA2 version is listed for BS EN/EN61347-2-13 Appendix J emergency installations (EL), with AC input 100–240 VAC. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 1.0 mm²; LED output: the same cable designation. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $104.49

  • PWM-90-12DA2

    MEAN WELL PWM-90 series: DALI-2 PWM output LED driver - PWM-90-12DA2

    MEAN WELL PWM-90-12DA2 MEAN WELL PWM-90-12DA2 is a DALI-2 constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 7.5 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA2 control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-12DA2 Series and function code PWM-90; DA2: DALI-2 DT6 control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 7.5 A Rated output power 90 W Output PWM frequency 2.5 kHz, fixed typical output waveform frequency. Dimming interface DALI-2 DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 88% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Hiccup mode; automatic recovery after the fault is removed. Overvoltage protection 15–17 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. DALI polarity The DA/DA2 DALI pair is polarity-insensitive; the wire labels do not imply a polar DC output. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. This 12 V model is excluded from the catalog Class 2 claim. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA2 version. Emergency-lighting scope This DA2 version is listed for BS EN/EN61347-2-13 Appendix J emergency installations (EL), with AC input 100–240 VAC. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 1.0 mm²; LED output: the same cable designation. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI-2 interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $104.49

  • PWM-90-24DA

    MEAN WELL PWM-90 series: DALI PWM output LED driver - PWM-90-24DA

    MEAN WELL PWM-90-24DA MEAN WELL PWM-90-24DA is a DALI constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 3.75 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-24DA Series and function code PWM-90; DA: DALI control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 3.75 A Rated output power 90 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface DALI DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. DALI polarity The DA/DA2 DALI pair is polarity-insensitive; the wire labels do not imply a polar DC output. Safety, insulation and compliance Parameter Specification Safety and design standards CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA version. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 1.0 mm²; LED output: the same cable designation. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $115.82

  • PWM-90-12DA

    MEAN WELL PWM-90 series: DALI PWM output LED driver - PWM-90-12DA

    MEAN WELL PWM-90-12DA MEAN WELL PWM-90-12DA is a DALI constant-voltage PWM output LED driver for compatible 12 V LED strips, rated 7.5 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact DA control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-12DA Series and function code PWM-90; DA: DALI control Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 12 V Rated output current 7.5 A Rated output power 90 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface DALI DT6 Dimming range Catalog range 0–100%; DALI first step/minimum output duty approximately 0.2%. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 88% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. DALI power-on timing requires a compatible controller; otherwise setup can exceed 0.5 s. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 15–17 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Control wiring and operation Parameter Specification DALI operation Apply the DALI signal between DA+ and DA−; DT6 brightness control. DALI supports 16 groups and 64 addresses. The catalog identifies the interface as primary-side; maintain the required insulation. DALI polarity The DA/DA2 DALI pair is polarity-insensitive; the wire labels do not imply a polar DC output. Safety, insulation and compliance Parameter Specification Safety and design standards CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. This 12 V model is excluded from the catalog Class 2 claim. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Input/DALI and output/DALI: 1.5 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. DALI standards IEC62386-101, -102, -207 (DT6) and Part 251; apply only the selected mode and the supplied DA version. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DA+ purple, DA− pink. Cable specification Input: SJOW 17 AWG × 2C & H05RN-F 1.0 mm²; LED output: the same cable designation. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm compatibility with this DALI interface. The catalog’s general installation note cites 0.15 mA per PWM driver; this is not a complete DALI bus/controller sizing specification. Follow the dedicated interface wiring and controller requirements. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

    $115.82

  • PWM-90-48

    MEAN WELL PWM-90 series: 3-in-1 dimmable PWM output LED driver - PWM-90-48

    MEAN WELL PWM-90-48 MEAN WELL PWM-90-48 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 48 V LED strips, rated 1.88 A and 90.24 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-48 Series and function code PWM-90; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 48 V Rated output current 1.88 A Rated output power 90.24 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 54–60 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 16 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

  • PWM-90-36

    MEAN WELL PWM-90 series: 3-in-1 dimmable PWM output LED driver - PWM-90-36

    MEAN WELL PWM-90-36 MEAN WELL PWM-90-36 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 36 V LED strips, rated 2.5 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-36 Series and function code PWM-90; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 36 V Rated output current 2.5 A Rated output power 90 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 41–46 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 16 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.

  • PWM-90-24

    MEAN WELL PWM-90 series: 3-in-1 dimmable PWM output LED driver - PWM-90-24

    MEAN WELL PWM-90-24 MEAN WELL PWM-90-24 is a 3-in-1 dimmable constant-voltage PWM output LED driver for compatible 24 V LED strips, rated 3.75 A and 90 W. Its Class II plastic enclosure is fully encapsulated to IP67. Select for the exact Blank control version and apply the input and thermal derating below. Download MEAN WELL PWM-90 Datasheet (PDF)Download MEAN WELL LED Installation Manual (PDF)Datasheet section: PDF pages 44–51; specifications on page 45. Model, output and control Parameter Specification Model PWM-90-24 Series and function code PWM-90; blank suffix: 3-in-1 dimming Output mode Constant voltage with PWM-style output; dimming varies output-current duty cycle. Built-in active power factor correction (PFC). DC output voltage 24 V Rated output current 3.75 A Rated output power 90 W Output PWM frequency 1.47 kHz, fixed typical output waveform frequency. Dimming interface 0–10 VDC, additive 10 V PWM at 100 Hz–3 kHz, or resistance between DIM+ and DIM− Dimming range Catalog range 0–100%. Approximate minimum output duty 0.15% at 0.6 VDC, 6 kΩ (one driver), or 6% duty of the external 10 V PWM signal; lower input can dim the output to 0%. Dimming source and synchronization 100 μA typical source current. Resistance scaling: 100 kΩ / N at full output, where N is the number of synchronized drivers. Do not connect DIM− to the negative LED output. Use a controller with capacity of at least 0.15 mA per PWM driver, as required by the installation instructions. Input and performance Parameter Specification Input voltage 90–305 VAC or 127–431 VDC; apply input-voltage and thermal derating. Before DC wiring, verify the manufacturer’s polarity requirements for this model. Input frequency 47–63 Hz Typical efficiency 90.5% at the catalog test conditions Typical power factor >0.98 / 115 VAC; >0.96 / 230 VAC; >0.92 / 277 VAC at full load; PF changes with load. THD <20% at ≥60% load / 115 or 230 VAC, or ≥75% / 277 VAC; consult the model-specific load curves. Typical AC input current 0.95 A / 115 VAC; 0.5 A / 230 VAC; 0.4 A / 277 VAC Inrush current Cold start: 60 A typical at 230 VAC; 550 μs pulse width measured at 50% peak, per NEMA 410. Circuit-breaker reference 3 / 6 units for type B / type C 16 A breakers at 230 VAC, respectively. Catalog reference only; verify the actual breaker and system conditions. Leakage current <0.25 mA at 277 VAC No-load or standby power <0.5 W no-load consumption. Setup and rise time 500 ms setup, 80 ms rise / 115 or 230 VAC. Cold-start measurement; rapid switching may increase setup time. Hold-up time 16 ms / 115 or 230 VAC typical Protection and operating conditions Parameter Specification Overload protection 108–130% of rated output; Hiccup mode; automatic recovery after the fault is removed. Short-circuit protection Output shuts down; remove the fault, then re-power to recover. Overvoltage protection 28–34 V; Output shuts down; remove the fault, then re-power to recover. Overtemperature protection Output shuts down; remove the fault, then re-power to recover. Working case temperature −40 to +85°C; maximum case temperature +85°C, subject to derating. Cooling and load derating Free-air convection with recommended horizontal mounting. 100% through +50°C ambient, falling to 50% at +70°C. The −40°C to −25°C region is for 230 VAC input only. Keep Tc at or below +85°C; apply both ambient and input limits. Input/load derating At 60 Hz: 80% at 90 VAC, rising to 100% at 100 VAC; 100% through 305 VAC. Humidity and storage Working: 20–95% RH, non-condensing. Storage: −40 to +80°C, 10–95% RH. Temperature coefficient ±0.03%/°C over 0–50°C Altitude derating Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this fanless design. Vibration 10–500 Hz, 5 G, 12 minutes per cycle, 72 minutes along each X/Y/Z axis. Safety, insulation and compliance Parameter Specification Safety and design standards UL8750 (cover identifies Type HL for this Blank/DA2 version); CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 and BS EN/EN62384, independent control gear; IP67; EAC TP TC 004; GB/T19510.1 and GB/T19510.213. BS EN/EN60335-1 is a design reference. Class II without FG; SELV output. Class 2 power unit. Type HL applications: Class I, Division 2 hazardous (classified) locations, subject to the listed installation conditions. BIS IS15885 (Part 2/Sec13) is listed for this model/version. EMC Emission: BS EN/EN55015, BS EN/EN61000-3-2 Class C at ≥60% load, BS EN/EN61000-3-3, GB/T17743, GB17625.1 and EAC TP TC 020. Immunity: BS EN/EN61000-4-2/-3/-4/-5/-6/-8/-11, BS EN/EN61547 light-industry level, line-to-line surge 2 kV, and EAC TP TC 020. Final equipment requires EMC requalification. Insulation Input/output withstand: 3.75 kVAC. Insulation resistance input/output: 100 MΩ at 500 VDC, 25°C / 70% RH. MTBF 2394.5 / 224.2 thousand hours minimum, Telcordia SR-332 / MIL-HDBK-217F (25°C), respectively; statistical estimates, not guaranteed service life. Dimensions and installation Parameter Specification Dimensions 171 × 63 × 37.5 mm (L × W × H); plastic housing. Lead connections Input: AC/L brown, AC/N blue. LED output: +V red, −V black. Control: DIM+ purple, DIM− pink. Do not connect DIM− to negative LED output. Cable specification Input: SJTW 18 AWG × 2C; LED output: SJTW 16 AWG × 2C. Control: UL2464 18 AWG × 2C. Lead runs: 300 ±20 mm; refer to the mechanical drawing for breakout lengths. Mounting Use the model-specific drawing; 4.5 mm mounting holes. Maintain recommended horizontal mounting and keep the marked Tc point below the case-temperature limit. Ingress protection Fully encapsulated IP67, for dry, damp or wet locations subject to the installation instructions. Suitable indoors or outdoors without direct sunlight; do not immerse or operate the product in water. Seal system interconnections and any waterproof connector against water ingress. Installation Disconnect the supply before installation or maintenance and prevent inadvertent reconnection. Keep ventilation clear, do not stack objects on the unit, and leave 10–15 cm clearance when the adjacent device is a heat source. Approved primary/secondary cables must carry at least the unit’s rated current. Nonstandard mounting or high ambient temperature requires derating. Confirm controller compatibility; the catalog calls for 0.15 mA controller capacity per PWM driver. Insulate system interconnections and enclose single-insulated wires; do not dismantle the driver. Damaged external cables must be replaced by the manufacturer, its service agent or an equally qualified person. Dimming isolation Treat the analog dimming circuit as not isolated from the secondary output, as specified in the LED installation manual; provide appropriate system insulation. Weight 770 g; catalog packing reference per unit (0.77 kg × 1000), not a measured net or shipping parcel weight. Service-life reference Typical lifetime >50,000 hours when the marked Tc/TMP point is about +75°C or below. Manufacturer catalog warranty: 5 years, subject to MEAN WELL’s warranty statement; not an additional store promise. Unless stated otherwise, catalog parameters are measured at 230 VAC input, rated current and +25°C ambient. Typical figures and load curves apply only to their stated conditions. Read the linked drawings and installation instructions before system design.


You have seen 24 out of 55 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa